The Light-DEC is a universal Layout-Light-Control for
analogue and digital model railway layouts from the
Digital-Professional-Series!
Various light-functions can be assigned to up to 160 light-
outputs and can be automatically controlled within the
daylight-cycle or can be switched ON or OFF via push buttons
or DCC-Commands.
Light-DEC-Basic-F Part-No.: 810222
>> Basic-Module as finished module <<
K J
red brown
D1
Light-DEC V1.0
IC5
BU1
Littfinski DatenTechnik (LDT)
This product is not a toy! Not suitable for children under 14 years. Improper use will imply danger or injuries due to
sharp edges and tips! Please store this instruction carefully.
12:15:00 T 300
Light-DEC-Service
Rev. 1.0
Littfinski DatenTechnik (LDT)
Light-DEC-Basis
Rev. 1.0
S3
KL1KL2KL3KL4
S2
S4
7
8
+5V
S1
4
5
6
Taster / Button
R1
1
2
3
GND
The universal Layout-Light-
KL5
Light-DEC consist of one Basicand as minimum of one Light(Light-Display or Lighthas to be plugged on
Basic-Module.
Light-Display-Modules contain
outputs, which can cover a load of 0.
Ampere each. Light-Power-Module with
24 outputs can supply a current of
2.5 Ampere each output.
With one Basic-
160 light outputs via max. 7 LightModules controlled. The
effects (Neon-lamps, Flash-lights
Running-lights, Trafficmany others)
individual to the particular outputs.
CE Part-No.:
146 40 16
Layout-Light-Control Light-DEC – Manual
Content: Page
1. Introduction / Safety Instruction 2
2. Connect the Basic-Module to the first Light-Module 3
2.1. Using further Light-Modules 4
2.2. Connect light sources to the Light-Modules 5
3. Connect push-buttons or switches to the Basic-Module 7
4. Connect the Basic-Module with the digital layout 7
5. First starting-up / selecting language 8
5.1. Register external push-buttons or switches 9
5.2. Register used Light-Modules at the Basic-Module 10
5.3. Light source test 11
6. Adjusting start time for day-sequence of the light control 11
6.1. Selecting start options of the light control 12
6.1.1 Start/stop of Light-DEC via external push buttons/switches 13
6.1.2 Start/stop of Light-DEC via DCC-Addresses 13
7. Day-phases: select start timing and time-factors for daybreak,
day, dusk and night 14
8. Setup of switch groups and switch times 15
9. Available light functions 17
10. Light adjustment: individually matching of parameters of
light-functions 17
11.5. Output function: night function for traffic light pedestrian
and traffic light cross road 22
12. Factory setting 22
- 1 -
Layout-Light-Control Light-DEC – Manual
1. Introduction/Safety instruction
You have purchased the Basic-Module for the Layout-Light Control Light-DEC for
your model railway.
The Basic-Module is a high quality product that is supplied within the assortment of
Littfinski DatenTechnik (LDT).
We are wishing you having a good time using this product.
The finished module comes with 24 month warranty.
• ·Please read the following instructions carefully. Warranty will expire due to
damages caused by disregarding the operating instructions. LDT will also not be
liable for any consequential damages caused by improper use or installation.
• Each Light-DEC-Basic-Module will be supplied together with a Technical Manual. It
contains a graphic menu navigation and tables. We have separated those
information at your ease to prevent the requirement of searching on differentpages within this manual.
• At the section “Downloads” on our Web-Site (www.ldt-infocenter.com) you can
find this Basic Manual and the Technical Manual as PDF-File with colored illustrations. You can open, download and print it with the Acrobat Reader.
Many illustrations at this manual are identified with a file name (e.g. page_1611).
You can find those files on our Web-Site at the section “Sample Connections” of
the Layout-Light-Control Light-DEC. You can download the files as PDF-File and
make a colored print at the DIN A4 format.
• Attention: Perform all connection-work only after disconnect the model railway
layout from mains (disconnect all main-plugs of model railway transformers
and switched mode power supplies or switch off the socket strips).
• The Light-Display-Modules contain a large capacitor, which has to be
completely discharged before the Light-Display-Module can be connected or
disconnected. Please wait a couple of minutes after switching off the supply
transformer before you connect or disconnect the Light-Display-Module.
Optional:
Von DCC-Digitalzentrale
oder Booster
From DCC command station
or booster
J
max. 2,5 Amax. 2,5 A
16151413121110
987654321
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
KL1KL2KL3KL4KL5KL6KL7
max. 0,5 Ampere
26272829303132
25
KL4KL3KL2KL1
8
9
101112131415161819202122232417
1234567
D1
Light-DEC V1.0
IC5
Light-Power
Rev. 1.2
BU1
white weiss
OUT
BU3
KL8
KL10KL11
KL9
17181920212223
12 ... 24 V DC
24
- +
12...24V DC
Littfinski DatenTechnik (LDT)
KL12
ST1
BU1
white
white weiss
weiss
BU2
IN
OUT
BU3
KL7
max. 1 Ampere
KL5
KL6
braun
10...18V~
39383736353433
40
12...24V=
braun
brown
Vom Modellbahntrafo
From transformer
gelb
yellow
ST1
white
weiss
BU2
IN
gelb
12:15:00 T 300
BU1
Light-DEC-Service
Rev. 1.0
Littfinski DatenTechnik (LDT)
Light-DEC-Basis
Rev. 1.0
Littfinski DatenTechnik (LDT)
S2
S3
S4
KL1KL2KL3 KL4
8
+5V
Taster / Button
page_1611
The Light-DEC Basic-Module (right) in connection to one Light-Display- (middle) and one Light-
Power-Module (left).
K
braun
rot
brown
red
K J
red brown
KL5
S1
R1
1234567
GND
- 2 -
Layout-Light-Control Light-DEC – Manual
2. Connect the Basic-Module with the first Light-Module
Connect the Basic-Module via the 10-poles socket bar BU1 either with a LightDisplay- or a Light -Power-Module. It is essential to attend careful to the position of
the pin bar of the Light-Display- and the Light-Power-Module and that there is no
offset to the socket bar of the Basic–Module. If the printed circuit boards of the
Basic- and Light-Module are inserted into a position that they are flush on top and
bottom both modules are correctly connected.
Optional:
Von DCC-Digitalzentrale
oder Booster
From DCC command station
or booster
J
K
braun
rot
brown
red
K J
red brown
KL5
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
Modellbahnlämpchen
model incandescent
lamp
26272829303132
25
18192021222324
17
Leuchtdiode
light-emitting diode
Vorwiderstand
series resistor
9
10111213141516
8
1234567
BU1
white
weiss
OUT
page_1601
The Light-DEC Basic-Module with the first directly connected Light-Display-Module.
max. 2,5 Amax. 2,5 A
BU1
white weiss
OUT
KL4KL3KL2KL1
KL5
BU3
161514
BU3
KL8
KL7
13
121110
KL9
171819
9
KL10KL11
20
KL6
braun
10...18V~
39383736353433
40
12...24V=
braun
brown
Vom Modellbahntrafo
From transformer
876
212223
24
5
12 ... 24 V DC
BU2
gelb
gelb
yellow
432
Littfinski DatenTechnik (LDT)
KL12
ST1
white
weiss
IN
1
KL1KL2KL3KL4KL5KL6KL7
Light-Power
Rev. 1.2
white weiss
BU2
D1
IC5
BU1
Light-DEC-Service
Rev. 1.0
Littfinski DatenTechnik (LDT)
Light-DEC-Basis
Rev. 1.0
Littfinski DatenTechnik (LDT)
D1
IC5
BU1
ST1
IN
Littfinski DatenTechnik (LDT)
Light-DEC V1.0
12:15:00 T 300
S2
S4
6
7
Taster / Button
S2
S4
7
8
S1
4
5
5
6
Taster / Button
S3
KL1KL2KL3KL4
8
+5V
Light-DEC V1.0
12:15:00 T 300
Light-DEC-Service
Rev. 1.0
Littfinski DatenTechnik (LDT)
Light-DEC-Basis
Rev. 1.0
S3
KL1KL2KL3 KL4
+5V
R1
1
2
3
GND
Optional:
Von DCC-Digitalzentrale
oder Booster
From DCC command station
or booster
J
K
braun
rot
brown
red
K J
red brown
KL5
S1
R1
1
234
GND
page_1608
The Light-DEC Basic-Module with the first directly connected Light-Power-Module.
- +
12...24V DC
- 3 -
Layout-Light-Control Light-DEC – Manual
The first Light-Module has to be always directly connected onto the Basic-Module
for voltagesupply.
Attend as well to the separate Operation Instruction of the Light-Display- or LightPower-Module.
At the Operation Instruction you can find as well basic instruction for the
connection of the power supply and the connection of model incandescent lamps
or light emitting diodes (LED) within the section ”Connection of Illumination”.
2.1. Using further Light-Modules
Via the Basic-Module is it possible to control with max. 7 Light-Modules up to 160
light-ouputs. A variable combination of Light-Display- and Light-Power-Modules is
possible.
A Light-Display-Module contains 40 and a Light-Power-Module 24 outputs. If there
are only Light-Power-Modules connected can be with 7 of those Modules (7 x 24 = 168 light-outputs) used. The last 8 outputs of the seventh Light-Power-Module
cannot be used for control connection because the maximum quantity of 160 light outputs will be exceeded by 8.
If there are only Light-Display-Modules used with 40 outputs each there can be 4 of
those modules (4 x 40 = 160 light-outputs) used at the Basic-Module.
Combined used can be 5 to 7 Light-Modules used on one Basic-Module. If the
summary will be more than 160 light outputs will be the surplus outputs not
controlled.
The Light-Modules shall be connected directly next to each other as shown at the
illustration on page 2 with one Light-Display- and one Light-Power-Module each.
If the Light-Modules shall be installed at an extended situation to be closer to the
light sources there shall be shielded interference-protected patch-cables
(computer network cable) used for the connection.
1234567
8
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
BU1
white
weiss
OUT
1234567
8
26272829303132
25
KL4
KL3KL2KL1
KL7
BU3
9
101112131415161819202122232417
ST1
white
weiss
KL5
KL6
BU2
braun
10...18V~
39383736353433
40
12...24V=
IN
gelb
xm
Bestellbezeichnung /
Order code: Kabel Patch xm
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
BU1
white
weiss
OUT
26272829303132
25
KL4
KL3KL2KL1
KL7
BU3
9
101112131415161819202122232417
D1
Light-DEC V1.0
IC5
12:15:00 T 300
BU1
ST1
white
weiss
Light-DEC-Service
Rev. 1.0
S3
KL5
KL6
BU2
braun
gelb
10...18V~
39383736353433
40
12...24V=
IN
Littfinski DatenTechnik (LDT)
Light-DEC-Basis
Rev. 1.0
Littfinski DatenTechnik (LDT)
KL1KL2KL3 KL4
+5V
page_1607
The second Light-Display-Module has been connected to the first Module via a Patch-Cable.
S2
S4
8
Optional:
Von DCC-Digitalzentrale
oder Booster
From DCC command station
or booster
braun
brown
S1
Taster / Button
J
K
rot
red
K J
red brown
KL5
R1
1234567
GND
- 4 -
Layout-Light-Control Light-DEC – Manual
It is as well possible to connect the Light-Modules to each other via the “Kabel
Light@Night” at a distance of 0.5m, 1m or 2m.
On this way can be as well older Light-Modules without RJ-45 sockets for a patch-
cable connection connected to each other on a longer distance of up to 2m.
Optional:
Von DCC-Digitalzentrale
oder Booster
From DCC command station
Bestellbezeichnung /
Order code: Kabel Light@Night xm
1234567
8
26272829303132
25
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
KL4KL3KL2KL1
BU1
white
weiss
KL7
OUT
BU3
1234567
8
9
101112131415161819202122232417
weiss
white
xm
weiss
white
Stiftleiste (Adapter)
pin plug (adapter)
ST1
white
weiss
KL5
KL6
BU2
braun
10...18V~
39383736353433
40
12...24V=
IN
gelb
26272829303132
25
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
KL4KL3KL2KL1
BU1
white
weiss
KL7
OUT
BU3
9
101112131415161819202122232417
D1
Light-DEC V1.0
IC5
12:15:00 T 300
BU1
ST1
white
weiss
Light-DEC-Service
Rev. 1.0
S3
KL5
KL6
BU2
braun
gelb
10...18V~
39383736353433
40
12...24V=
IN
Littfinski DatenTechnik (LDT)
Light-DEC-Basis
Rev. 1.0
Littfinski DatenTechnik (LDT)
KL1KL2KL3 KL4
+5V
page_1606
The second Light-Display-Module has been connected to the first Module via a Kabel
Light@Night.
2.2. Connect light sources to the Light-Modules
Some light-functions require only one light source (model railway incandescent
lamps or light emitting diodes – LED). Maximum is 10 light sources for the lightfunction traffic-light cross-road.
If one light-function requires more than one light-source those have to be connected
to the clamps of the Light-Modules in series and ascending sequence.
For the light-function of Running Light 4 and 5, Fun-Fair and Construction Work 5
and 8 shall be the light-sources in series connected to the clamps at the sequence
of the actual installed situation.
The light-function Control-Center requires 3 light-sources, which have to be
implemented into the control center to simulate the light of a switch panel. The
first clamp shall be connected to the red, the second to the green and the third to
the yellow light-source.
3 light-sources are required for the light-function TV-Set which have to be installed
into the TV-room for simulation of a running TV-Set. The first clamp shall be
connected to the red, the second to the green and the third to the blue light-source.
The light-function Traffic-Light Pedestrian occupies 5 clamps but provides via
those clamps voltage to 10 light -sources. There shall be 2 light-sources connected
to one clamp. Both Pedestrian- and both Traffic-road lights will be electrical
parallelswitched on this way because they will show always the same light phases.
For the correct function is it required that the traffic-light-sources have to be
connected to the correct clamps.
The following illustration shows, which light-source has to be wired to which clamp of the Light-Module.
or booster
J
K
braun
rot
brown
red
K J
red brown
KL5
S2
S1
S4
8
Taster / Button
R1
1234567
GND
- 5 -
Layout-Light-Control Light-DEC – Manual
Leuchtdiode
K
3736353433
light-emitting diode
Vorwiderstand
series resistor
141516
K
K+1
K+3
K+4
K+2
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
K+4
K+3
26272829303132
25
KL4KL3
K+2
K+1
18192021222324
17
K+4
K+2
K+1
K
Ausgang / Output Bezeichnung / Function Farbe / Color
K Straße Rot / road red Rot / red
K+1 Straße Gelb / road yellow Gelb / yellow
K+2 Straße Grün / road green Grün / green
K+3 Fußgänger Rot / pedestrian red Rot / red
K+4 Fußgänger Grün / pedestrian green Grün / green
K+3
BU1
white
weiss
OUT
BU3
KL7
page_1678
Connection of Pedestrian Traffic-Light (Light –function Traffic-Light Pedestrian) with light
emitting diodes to a Light-Display-Module (LDM).
The light-function Traffic-Light Cross-Road creates all required traffic-light
sequences for cross-roads and road-intersections.
Up to 20 light-sources will be supplied via 10 clamps from one Light-Module. Two
light-sources each shall be connected to one clamp.
Which light-source has to be wired to which clamp shows the following illustration.
K+7
K+6
K+5
K+3
K+4
Hauptstraße
K+9
K+8
K+4
K+2
K+6
K+8
K+3
K+1
K+7
K+5
26272829303132
K+9
25
18192021222324
K
K+1
K+2
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
K
17
Leuchtdiode
light-emitting diode
Vorwiderstand
series resistor
141516
Nebenstraße
minor road
KL4KL3
K+4
K+3
K+2
K+1
K
K+8
K+9
K+5
K+6
main road
Ausgang / Output Bezeichnung / Function Farbe / Color
K Nebenstraße Rot / minor road red Rot / red
K+1 Nebenstraße Gelb / minor road yellow Gelb / yellow
K+2 Nebenstraße Grün / minor road green Grün / green
K+3 Fußgänger Nebenstr. Rot / pedestrian minor road red Rot / red
K+4 Fußgänger Nebenstr. Grün / pedestrian minor road green Grün / green
K+5 Hauptstraße Rot / main road red Rot / red
K+6 Hauptstraße Gelb / main road yellow Gelb / yellow
K+7 Hauptstraße Grün / main road green Grün / green
K+8 Fußgänger Hauptstr. Rot / pedestrian main road red Rot / red
K+9 Fußgänger Hauptstr. Grün / pedestrian main road green Grün / green
page_1679
K+7
BU1
white
weiss
BU3
KL7
3736353433
OUT
Connection of a traffic-light system of a cross-road (Light-function traffic-light cross-road) with
light emitting diodes to a Light-Display-Module.
- 6 -
Layout-Light-Control Light-DEC – Manual
From DCC command station
3. Connect push-buttons or switches to the Basic-Module
The Basic-Module contains a 10-poles clamp bar for the connection of up to 8 PushButtons or Switches. Via those external push-buttons or switches is it possible to
start or stop manually the Light-Control Light-Dec or single light-functions.
Optional:
Von DCC-Digitalzentrale
oder Booster
or booster
J
braun
brown
K
rot
red
K J
red brown
KL5
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
Modellbahnlämpchen
model incandescent
lamp
26272829303132
25
18192021222324
17
Leuchtdiode
light-emitting diode
Vorwiderstand
series resistor
9
10111213141516
8
1234567
KL4KL3KL2KL1
D1
Light-DEC V1.0
IC5
BU1
white
weiss
ST1
IN
Littfinski DatenTechnik (LDT)
BU1
white
weiss
KL5
OUT
BU3
KL7
KL6
BU2
braun
gelb
10...18V~
39383736353433
40
12...24V=
braun
brown
Vom Modellbahntrafo
From transformer
gelb
yellow
page_1612
Up to 8 push-buttons or switches can be connected to the 10 poles clamp bar of the Basic-
Module.
One pole of the push buttons or switches has to be always connected to the earth
terminal, which is marked with “GND”. The second pole shall be connected to one of the clamp 1 to 8. The clamp “+5V” will not be required by use of push-buttons or
switches.
If a light-function is assigned to a push-button will the function be started with the
first keystroke and stopped with the second keystroke. If a switch will be used will
be the functionactiveas long as the switch will be in “ON” position.
If there are push buttons or switches connected can be individually transmitted to the basic module for each of the 8 inputs (as described at section 5.1).
The factory setting for all 8 inputs is adjusted to push buttons.
12:15:00 T 300
Light-DEC-Service
Rev. 1.0
Littfinski DatenTechnik (LDT)
Light-DEC-Basis
Rev. 1.0
S2
S3
KL1KL2KL3KL4
7
8
+5V
S1
S4
4
5
6
Taster / Button
Taster oder Schalter
Push button or switch
R1
1
2
3
GND
4. Connect the Basic-Module with the digital layout
If you want to start and stop the Light-Control Light-DEC or single output-
functions digital via DCC-addresses the Basic Module requires digital
informations.
Those receive it via the connection clamp KL5 as shown at the sampleconnections on page 1 to 5. Supply the basic module with digital voltage directly
from the digital central unit with integrated booster or from an external booster or
from the digital ring-conductor “Switching” because then will be interference-protected data available.
- 7 -
Layout-Light-Control Light-DEC – Manual
>
English
<
Do not supply the digital voltage for the Basic-Module directly from the rails.
DCC-Digital systems are using different cable colors or designations for both
digital cables. Mostly used markings are printed next to clamp 5 but do not
necessarily to be used because the Basic-Module will automatically evaluate the
correct DCC-digital signal.
5. First starting-up / selecting language
As soon as the first Light-Module which has been
directly plugged onto the Basic-Module receives
power supply the operation status will be
indicated at the display with a short delay:
If the Display does not correct indicate during first starting -up you should turn with
help of a small screwdriver carefully the potentiometer P1. This Potentiometer is
located at the right side below the display has to be turned halfway left or right until
the information on the display can be optimal read.
For the first 40 light-outputs are output-functions set ex-factory, which will be
started at random within the first 15 seconds after switching-on the unit. If you have
installed some light sources onto the first 40 light outputs those will now lighten
and flash on different intervals.
The starting of the light-functionsat randomafter switching-on provides an
optimal optical impression because multiple installed light functions shall not be
running synchronized.
Within the Technical Manual you can find at the section “Output-Functions /
Factory setting” a table which indicates the assignment of output functions to the
related clamps set ex-factory.
VX.X at the Display of the Operation Display indicates the firmware version of the
Basic-Module. More information about the lower line of the display can be found at
the following pages of this manual.
Below the Display you can find 4 push-buttons indicated with arrows for the
directions LEFT, RIGHT, ABOVE and BELOW. Within the further description those
keys will be indicated as LEFT, RIGHT, ABOVE and BELOW.
The Technical Manual includes a graphical Menu Navigation to illustrate the steps
through the menusparallel to the following descriptions.
Depress now the key RIGHT longer as three
seconds. The display changes into the Main
Menu and all light sources will be switched off:
Ex-factory has been the language “Deutsch” reselected. If you don’t want to
change the language just skip the following lines and carry on reading with chapter
5.1.
If you want to select the language “Deutsch” just
activate the key RIGHT. The display will indicate
the actual selected language:
Light-DEC VX.X
22:30:00 A 300
---Main Menu---Language
Language
- 8 -
Layout-Light-Control Light-DEC – Manual
>
Deutsch
<
With the keys ABOVE or BELOW you can switchover between >Deutsch< and >English<.
Leave the language selection with the key LEFT
for using now the selected language.
If you would have selected>Deutsch< the display
would show now:
5.1. Register external push-buttons or switches
Depress within the main menu several times
shortly the key BELOW until the display shows:
To register the used external push buttons or
switches depress again the key RIGHT. The
Display shows the actual setting for the input 1:
With the keys ABOVE or BELOW you can select
one of the 8 inputs. The actual setting (switch or
push button) will be indicated matched to the
input (e.g. input 7):
Ex factory are all 8 inputs set for push buttons.
General: values between a bigger- and smaller sign (> <) can be edited with the
keys ABOVE or BELOW step-wise with single keystrokes.
Is the value range for the selection of a very large value (e.g. for a time selection)
will be the editing value indicated with curly braces (} {). If the keys ABOVE or BELOW will be activated for a longer duration as 2 seconds the adjustable values
at the display will keep running until the key will be released.
If you want to change the setting of an input you have at first to select via ABOVE or
BELOW the number of the input (e.g. position 3).
Activate now the key RIGHT for editing the
setting. The previous setting of push button will
now be shown between a bigger- and smaller sign.
Now you can select with the keys ABOVE or
BELOW either >push button< or >switch<.
Leave now the selection with the key LEFT for the
use of the indicated setting. If you have selected for the input 3 a switch the display will show now:
Language
---Hauptmenü----
Sprache
---Main Menu----
Buttons/Switches
Button / Switch
>1< = Button
Button / Switch
>7< = Switch
Button / Switch
3 = > Button <
Button / Switch
3 = > Switch <
Button / Switch
>3< = Switch
- 9 -
Layout-Light-Control Light-DEC – Manual
Now select as well the set-up for the other-inputs
or return with the key LEFT into the Main Menu:
Activate again the key LEFT to store the selected
adjustments at the Basic-Module. After a short
delay the display of the Basic-Module will indicate
the operation status:
5.2. Register used Light-Modules at the Basic-Module
Depress at the Main Menu the key BELOW
several times shortly until the display shows:
To register the employed Light-Module depress
the key RIGHT.
The display indicates which Light-Module has been registered on position 1 and is
therefore directly connected to the Basis-Module. LDM is the shortcut for the LightDisplay-Module with 40 light-outputs.
With the keys ABOVE or BELOW can be the
module position changed. On this way will be
indicated which modules are registered onto
other positions (e.g. position 4):
Ex-factory is four Light-Display-Modules (LDM) registered.
If you want to register one Light-Power-Module with 24 outputs on a position select
at first the module-position with the keys ABOVE or BELOW (e.g. position 2).
For editing the Light-Moduleactivate the key
RIGHT. The previous registered Light-DisplayModule (LDM) will be now indicated inside a
greater- and smaller sign.
With the keys ABOVE or BELOW you can select
between >LDM< and >LPM<. LPM is the shortcut
for Light-Power-Module.
Leave the selection with the key LEFT for using
the indicated Light-Module. If you have selected a
Light-Power-Module >LPM< the Display shows
now:
For other module positions select either further Light-Modules or proceed with the key LEFT back
into the Main Menu:
Activate now again the key LEFT for storing the
selected Light-Module at the Basic-Module. After
a short delay the display of the Basic-Module
shows the operation mode:
---Main Menu----
Buttons/Switches
Light-DEC VX.X
22:30:00 A 300
---Main Menu---Light-Modules
Module position
No.: >1< = LDM
Module position
No.: >4< = LDM
Module position
No.: 2 = >LDM<
Module position
No.: 2 = >LPM<
Module position
No.: >2< = LPM
---Main Menu----
Light-Modules
Light-DEC VX.X
22:30:00 A 300
- 10 -
Layout-Light-Control Light-DEC – Manual
Module: 2 = LDM
Module: 2 = LDM
Light
-
Modul: >
2
<
5.3. Light source test
With the light source test can be the light sources of all single Light-Module
outputs tested.
Depress at first the key RIGHT longer than three seconds. The display changes
into the Main Menu and all light sources will be switched off.
Depress now within Main Menu several times
shortly the key BELOW until the display shows:
Open the light source test with the key RIGHT:
With the keys ABOVE or BELOW can be the
Light-Module selected for the light source test of
the relative outputs (e.g.Light-Module 2):
With the key RIGHT will be the light source test
for the selectedLight-Module started. At the
upper line will be the number of the selected
Light-Module and the module type indicated.
LDM indicates a Light-Display-Module. If a light source has been connected to
output 1 this light source will glow constantly. All other light sources also those
connected to further Light-Modules will remain switched off.
With the keys ABOVE or BELOW can be the
output with the connected light source selected.
After testingall light sources of a Light-Module
you have to activate the key LEFT for eventually
selecting one further Light-Module for the light source test.
If you want to leave the light source test you have
to activate again the key LEFT. The display shows now the Main Menu.
From here you can proceed with the key LEFT to
the operation mode which will be indicated after a
short delay at the display of the Basic-Module:
6. Adjusting start time for day-sequence of the light control
At the bottom left of the operation display will be the actual daytime of the light
control indicated. The starting time has been set ex-factory for the running day to
22:30 hours (10:30pm). Via the menu-step start options can be the starting time
changed for the running day of the Light control Light DEC.
At first depress the key RIGHTlonger than three seconds. The display changes
into the Main Menu and all light sources will be switched off.
---Main Menu----
Lightsource test
Lightsource test
Light-Module: >1<
Lightsource test
Light-Module: >2<
Output :> 1<
Output:>22<
Lightsource test
---Main Menu----
Lightsource test
Light-DEC VX.X
22:30:00 A 300
- 11 -
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.