Suitable for the digital operation of all digital
The polar reversal at the reverse-loop will be performed without short-circuit via two sensor rails.
With reason to an external power supply possibility is a simple control of the reverse-loop with track occupancy module (e.g. RM-GB-8(-N) and RS-8) possible. The sensor rails will be controlled as well.
This product is not a toy! Not suitable for children under 14 years of age! The kit contains small parts, which should be kept away from children under 3! Improper use will imply danger or injuring due to sharp edges and tips! Please store this instruction carefully.
CE Part-No.: 24 80 36
Multi-Digital
formats
Introduction/Safety instruction:
You have purchased the reverse-loop module KSM-SG for your model railway layout. The KSM-SG module is a high quality product that is supplied
within the Digital-Professional-Series of Littfinski DatenTechnik (LDT).
We are wishing you having a good time using this product.
Please read the following instructions carefully. Warranty will expire due to damages caused by disregarding the operating instructions. LDT will also be not liable for any consequential damages caused by improper use or installation.
The KSM-SG comes as finished module and as finished module in a case with 24 month warranty.
Connecting the reverse-loop module to your digital model railway layout:
Attention: Before starting the installation switch off the drive voltage by pushing the stop button or disconnect the main supply.
The reverse-loop module receives the power supply via the clamp KL5. The voltage of 16...18V~ of a model railway transformer (ac output) is acceptable.
Operation mode:
The reversal polarity of the reverse-loop will be performed without short circuit due to 2 sensor-tracks which are located at the entrance and at the exit of the reverse-loop.
Both rails of the sensor tracks (A1/B1 and A2/B2) and the reverse loop (AK/BK) will be completely isolated and connected to the respective marked clamps at the reverse­loop module KSM-SG.
The sample connection 1 at the rear side of this instruction shows the complete wiring. The optimal length of the sensor rails will be 5 to 20 cm. The reverse-loop rail gets the supply via the clamps AK and BK. The reverse-loop rail has to have at minimum the length of the longest train of the layout.
The reverse-loop KSM-SG can switch up to 8 Ampere digital current.
The input A and B of the reverse-loop module KSM -SG will receive the digital current from the command station or from a booster from the ring-conductor “driving”. It is important that the reverse-loop will be complete inside one booster area and not between two rail sections which get the supply from two different boosters.
Because the KSM-SG itself requires no digital current and receives the energy from a model railway transformer is a simple wiring for the control of the reverse-loop in combination with track occupancy sensors possible.
The sample connections 2 at the rear side of this instruction shows the reverse-loop control via the feedback module RM ­GB-8(-N) with integrated track occupancy report.
The reverse-loop module KSM-SG inputs A and B receive digital current from one of the 8 outputs of the RM-GB-8(-N). On this process will be every current consumer within the reverse-loop recognized and produces an occupancy report. The sensor tracks will be controlled as well.
Further information related to the control of reverse-loops can be found at the Internet on our Web-Site (www.ldt­infocenter.com) within the section “Downloads”. Please download the file “Reversing loop monitoring” onto your PC.
At the section “Sample Connections” on our Web-Site are additionally samples for the reversal polarity with the reverse-
loop module KSM-SG for further track layouts available.
Accessories:
For safe installation of the reverse-loop modules below your model layout we offer an installation set under the order code
MON-SET and for the assembled kits a sturdy exact matching case (order code: LDT-01).
Sample Connection 1: Automatic polarity of a standard reverse-loop with the reverse-loop module KSM-SG.
Littfinski DatenTechnik (LDT)
Reverse loop module Kehrschleifenmodul
Digital-Profi werden!
Kehrschleifenmodul
KSM-SG
Kurzschlussfreie Umpolung über Sensorgleise.
Vom Modellbahntrafo From transformer
Short free reversion through sensor tracks.
~ ~
16...18V
KSM-SG
KL5
Rev. 1.1
Multi-Digital
L
ittfinski DatenTechnik (
D-25492 Heist
www.ldt-infocenter.com
A1 B1
A2 B2
B1
AKA2
B2
AK BKINA B
Loop
Sensor 1 Sensor 2
A1
BK
LDT
)
KL1KL2KL3KL4
A
B
B1
Ç
Ç
Ç
BK
Ç
A2
B2
AK
Ç
A1
Ç
Ç
Ç
Von Digitalzentrale oder Booster Ringleitung "Fahren" From command station or booster Ring conductor "driving"
Sample Connection 2: Reverse-loop polarity via the reverse-loop module KSM-SG plus track occupancy report at the reverse- loop with the RM-GB-8-N. Sensor tracks will be monitored as well.
Littfinski DatenTechnik (LDT)
Reverse loop module Kehrschleifenmodul
Digital-Profi werden!
Kehrschleifenmodul
KSM-SG
Kurzschlussfreie Umpolung über Sensorgleise.
Vom Modellbahntrafo From transformer
Direkteinspeisung ohne Rückmeldung. Direct supply without feedback.
Vom Modellbahntrafo From transformer
braun brown
gelb yellow
braun brown
braun brown
rot red
rot red
Short free reversion through sensor tracks.
KL5
~ ~
16...18V
Ç Ç Ç
Überwachtes "Normalgleis"
monitored
"standard track"
Intellibox
L
ittfinski DatenTechnik (
Multi-Digital
KSM-SG
Rev. 1.1
A1 B1
Sensor 1 Sensor 2
A1
12345678
IN1IN2
Digital-Profi werden!
Rückmeldemodul / Feedback module
RM-GB-8-N
8-fach Rückmeldemodul mit integrierten Gleisbelegtmeldern für den s88-Rückmeldebus. 8-fold feedback module with occupancy detectors for the s88-feedback bus.
s88-N
BU1 BU2
s88-N
OUT
OUT IN
Bestell­bezeichnung/ Order code: Kabel s88 xm
LDT
D-25492 Heist
www.ldt-infocenter.com
A2 B2
AK BKINA B
Loop
A
AKA2
BK
B2
B1
L
ittfinski DatenTechnik (
www.ldt-infocenter.com
ST2ST1
IN
weiss white
)
KL1KL2KL3KL4
B
s88-N
LDT
D-25492 Heist
8-fach Rückmeldemodul mit Gleisbesetztmeldern 8-fold feedback module with occupancy detectors
RM-GB-8-N
Rev. 1.1
B1
BK
Ç
AK
Ç
)
Ç
A1
Ç
A2
Ç
Ç
Ç
B2
Made in Europe by
Littfinski DatenTechnik (LDT)
Kleiner Ring 9
D-25492 Heist/Germany
Phone: 0049 4122 / 977 381
Fax: 0049 4122 / 977 382
Internet: http://www.ldt-infocenter.com
Subject to technical changes and errors. 03/2015 by LDT
Loading...