LCI LT3100 Operating Manual

LT3100 Operating Sheet – Issue 4
This meter is a coin/token operated electronic timer for the control of leisure based electrical appliances, e.g. lighting, solarium.
Switch on power
On power up the meter will briefly show ‘Pxx.x’ then the credit remaining on the meter.
Insert coin/token. The display will briefly show ‘Coin’. The display will then show the remaining credit. If the credit is greater than one hour it will be displayed in hours & minutes, e.g.; 2 hours will be displayed as ‘02:00'. If the credit is less than one hour it will be displayed in minutes & seconds, e.g.; 40 minutes will be displayed as ‘40:00' and an indicator will flash on the display to show this.
Collector functions
Resettable Money (Token) Counter
When the coin box becomes full, the message ‘COLL’ (collect) is displayed.
Upon removal of the coin box the display will automatically show the resettable money counter. This will show how much money has been inserted into the meter since the last collection.
When the coin box is reinserted, the money counter will automatically zero before displaying the remaining credit.
Note: To prevent the money counter from zeroing, insert the coin box with ‘B’ pressed.
Service Mode
To access service mode remove the coin box, press and release switch ‘B’ until the display changes to ' St.01 '.
The service mode consists of 10 settings.
01 Credit per coin/token (HH.MM.SS) 02 Credit per coin/token (HH.MM.SS) 03 Total money (Read only) 04 Total credit (Read only) 05 Pre-start (MM.SS) 06 Run-on (MM:SS) 07 Pre-end (MM.SS) 08 Maximum Credit (HH.MM.SS) 09 Totalise value (£’s & Pence) 10 Totalise credit value (HH:MM)
Press and release ‘B’ to step to the desired setting number. When the required number is showing on the display press and release ‘A’ to display the current setting. Press and
release ‘A’ to select the digit to be changed then press and release ‘B’ to alter that digit.
01 Credit Per Coin 1
Sets the amount of credit given by a 1 pound coin or token (except L1 token). Set in HH.MM or MM.SS (When the meter is set in single coin or Totalise + Top Up mode).
02 Credit Per Coin 2
Sets the amount of credit given by a 1€, 50c, 10p, 20p coin or L1 token. Set in HH.MM or MM.SS (When the meter is set in single coin or Totalise + Top Up mode)
03 Total Money
Displays the total amount of money/tokens inserted since the last factory reset. This is a read only display and cannot be changed.
04 Total Credit
Displays the total amount of credit given since the last factory reset. This is a read only display and cannot be changed.
05 Pre-start Sets the amount of time given before main session begins (entering zero disables this feature). Set in MM.SS
06 Run-on Sets the amount of time the meter operates after session has finished (entering zero disables this feature). Set in MM.SS
07 Pre-end Sets the time in which a warning is given before the session ends (entering zero disables this feature). Set in MM.SS
08 Maximum Credit Sets the maximum amount of credit to be given at any one session (activated by pressing the start button ‘A’). Set in HH.MM or MM.SS depending on the configuration number (entering zero disables this feature).
09 Totalise Value Sets the amount of money which needs to be inserted before any credit is given, e.g. £1:20.
10 Totalise Credit Value Sets the amount of credit given when the correct amount of money is inserted
To Clear Credit Remaining
Remove coin box. Display will show re-settable money counter.
Press and release switch B, display will show ‘Clr’. Press ‘A’ & ‘B’ together and credit will be cleared.
Note: If already in service mode, the display must be returned to show ‘Clr’ before this feature can be used (Press and release ‘B’ until ‘Clr’ is shown).
Credit Save
When available, the credit save is activated by the customer by pressing switch ‘B’. This will suspend the credit countdown and turn off the output to the load. The word ‘HELd’ will be displayed. To resume the countdown and reconnect the load, press switch ‘A’.
Override or Settings Disable Key Switch (optional)
Option A: When the override key is inserted and turned, the load will switch on and the word ‘FrEE’ will be
displayed. This action will also clear any remaining credit from the meter.
Option B: The internal settings, St.01 to St.10 can only be changed when the key switch is operated. This prevents unauthorised access to the meter settings.
Loading...