LCD Keypad
Y our Digiplex Security System is an advanced technology security system that will provide you with reliable security
protection and powerful features that are easy to use. The elegant and user-friendly LCD keyp ad will allow you easy
access to your security system's functions and information at the touch of a button. The 32-character LCD screen
will display messages and menus to guide you through the system’s operations. Your Installer can even customize
the messages for your home or business.
Since you will communicate your instructions to your system through the keypad, please read this manual carefully
and have your Installer explain basic system operation.
If you have the InTouch Voice Assisted Arm/Disarm Module (APR3-ADM2) connected to your Digiplex security
system, please refer to page 19 for operating instructions.
1.1LEGEND
[
SQUAREBRACKETS] Indicates information that must be entered on the keypad.
1.0 INTRODUCTION
Indicates a warning or an important note.
Indicates useful information or a tip.
2.0 BASIC OPERATION
The following sections will introduce you to the roles of the buttons, lights, and messages on your LCD keypad.
Figure 2.1: Basic Overview
“AC” LIGHT:
ON = AC power
OFF = Power failure
“STATUS” LIGHT:
When Green
ON = All zones are closed.
OFF = One or more zones are open.
FLASH = Exit Delay
When Red
ON = Area(s) armed
OFF = Area(s) disarmed
FLASH = System in Alarm
:
:
ACTION BUTTONS:
Each button’s function is explained in the following sections of the manual.
[CLEAR] = Erases current data entry
or reverts to the preceding step.
2.1AUDITORY FEEDBACK (BEEP TONES)
When you enter information on the keypad, the keypad will guide you with beep tones to communicate the
acceptance or rejection of your entries.
Confirmation Beep: When an operation (i.e. arming/disarming) is successfully entered or when the system
switches to a new status/mode, the keypad emits an intermittent beep tone (“
Rejection Beep: When the system reverts to a previous status, or when an operation is incorrectly entered, the
keypad emits a continuous beep tone (“
BEEEEEEEEEEP”).
The LCD screen will guide you
with detailed messages.
Use the arrow buttons to scroll
through the current menu when
the arrows appear in the LCD
screen.
[
ENTER] = Saves current data and
exits current menu.
BEEP-BEEP-BEEP-BEEP-BEEP”).
4 System Manager’s Manual
2.2CONFIDENTIAL MODE
Your Installer can program keypads to not display the status of your system automatically by changing the LCD
screen to Confidential Mode. In Confidential Mode:
• The zones and status messages will NOT be displayed
• The indicator lights will NOT illuminate
• Depending on how your keypad was programmed by your installer , you must either press a button or enter your User
Access Code to illuminate the indicator lights and activate Normal Mode.
2.3PARTITIONED SYSTEM
A separated system is called a Partitioned System, which can be useful in situations where shared security systems
are more practical. Your installer can design your system to recognize up to four separate protected areas. For
example, a company that has both an office area and a warehouse area can arm and disarm each area separately
and control the access to each area.
If you have access to more than one area, and you need to select a specific area(s) when prompted by your LCD
keypad, follow either one of the following three methods to make your selection:
• Press the keypad button corresponding to the area you wish to select (i.e. 1, 2,...4).
• Press the
• Use the
[0]
button for all areas.
[S]
and
[T]
buttons, and press
2.4AREA STATUS DISPLAY
The Area Status Display allows you to view the status of the selected areas in a Partitioned System (Refer to
section 2.3 on page 5).
To view the Area Status Display:
1. Enter your [
ACCESSCODE], then press the [1] button.
2. Press the button corresponding to the area (i.e. 1, 2,...4), or use the [S] and [T] buttons and press [
when the area you want to view appears on the screen.
3. Press [
CLEAR] to exit.
[
ENTER
]
when the area you want to select appears on the screen.
ENTER]
In Area Status Display mode, the following information will scroll on the LCD screen:
• “ready”: if all zones in the selected area are closed.
• “not ready”: if zones in the selected area are open.
• open zones within that area (i.e. “Front Door Open”).
• “Trouble(s)”: (section 7.0 on page 14) if a trouble has occurred.
• “Alarms in Memory”: (section 4.3 on page 8) if an alarm has occurred.
• “Armed” ; “Force Armed” ; “Instant Armed” ; “Stay Armed”: displays the arming status of the selected area.
When your system is armed, it can respond to any breach in the protected zones by causing an alarm and sending
a report to your Central Monitoring Station.
3.1EXIT DELAY TIMER
When you arm your system, it will trigger the Exit Delay Timer to provide you with enough time to exit the protected
area before the system is armed.
3.2REGULAR ARMING
This method is used for the everyday arming of your system. All zones within the protected area must be closed to
Regular arm the system.
1. Enter your [
2. Press the [
ACCESSCODE].
ARM] button.
3. If you have access to more than one area, select the area(s) you wish to Regular arm (refer to section 2.3 on
page 5).
3.0 ARMING
LCD Keypad 5
3.3STAY ARMING
Stay arming will partially arm your system to permit you to remain in your home or office by arming the outer zones
(perimeter) of the protected area (i.e. doors and windows).
1. Enter your [
ACCESSCODE].
2. Press the [STAY] button.
3. If you have access to more than one area, select the area(s) you wish to St ay arm (refer to section 2.3 on p age 5).
3.4INSTANT ARMING
This feature is the same as Stay arming except that there is no Entry Delay. Therefore, any armed zone that is
breached will immediately generate an alarm.
1. Enter your [
ACCESSCODE].
2. Press the [5] button.
3. If you have access to more than one area, select the area(s) you wish to Instant arm (refer to section 2.3 on
page 5)
3.5FORCE ARMING
Force arming allows you to quickly arm your system when zones are open. However, once the open zone is closed,
your system will then arm that zone as well.
1. Enter your [
2. Press the [
ACCESSCODE].
FORCE] button.
3. If you have access to more than one area, select the area(s) you wish to Force arm (refer to section 2.3 on
page 5).
3.6BYPASS PROGRAMMING
You can bypass certain zones when you arm the protected area(s). When a zone is bypassed, it will be ignored th e
next time your system is armed. Once your area is disarmed, the system will unbypass the zone.
1. Enter your [
2. Press the [
ACCESSCODE].
BYP] button.
3. Enter the zone number (i.e. 01, 02,...48), or use the [S] and [T] buttons and press [
want to bypass appears on the screen. If “bypassed” does not appear on the screen and the keypad emits a
Rejection Beep, you may not have access to bypass that zone.
4. Repeat step 3 until all zones you want to bypass have been selected.
5. Press the [
ENTER] button to save and exit.
In order to bypass a zone, the following conditions must be met:
- The zone must have the Bypass option programmed by the installer.
- Your User Access Code must be programmed to enable the Bypass option.
- Your User Access Code must have access to the zone’s Area Assignment.
- The zone’s area must be disarmed before the zone can be bypassed.
Fire Zones cannot be bypassed.
3.6.1BYPASS RECALL
Bypass Recall reinstates the zones that were bypassed the last time your system was armed.
1. Enter your [
2. Press the [
3. Press the
4. Press the [
ACCESSCODE].
BYP] button.
[MEM]button. Zones bypassed the last time your system was armed are bypassed.
ENTER] button to save and exit.
BYP] once the zone you
6 System Manager’s Manual
3.7ONE-TOUCH BUTTONS
If enabled by your Installer, you can access the following features without using your User Access Code by pressing
and holding the desired One-Touch button.
BUTTONFEATUREBUTTONFEATURE
[
ARM]Regular arm[DISARM]Disarm a Stay/Instant armed area
[
STAY]Stay arm[5]Instant arm
[
FORCE]Force arm[6]Change display settings
BYP]Bypass Programming[7]View Event Record display
[
3.8KEYSWITCH ARMING
A key can be used to arm and disarm your system using two forms of keyswitches. With a Maintained Keyswitch,
place the key in the “ON” position to arm your system, and place the key in the “OFF” position to disarm your
system. With a Momentary Keyswitch, place the key in the “ON” position briefly then place it back in the “OFF”
position to arm the system. Repeat this process to disarm with a Momentary Keyswitch.
3.9AUTO-ARMING
If enabled by your Installer, you can set the time that an area will arm itself automatically.
3.9.1TIMED AUTO-ARMING
Your installer can set Timed Auto-Arming to function in either Force or Stay arming mode. A sixty-second
Exit Delay sequence will begin prior to your system automatically arming itself at the programmed time.
1. Enter your [
ACCESSCODE].
2. Press the [0] button.
3. Press the [
MEM] button.
4. If you have access to more than one area, press the area’s
and press the [
5. Enter the time you want the area to be armed according to the 24-hour clock (i.e. 9 a.m. is 09:00 and
9 p.m. is 21:00).
6. Press the [
ENTER] button to save and exit.
number, oruse the [S] and [T] buttons
ACC] buttonwhen the area you want to program appears on the screen.
3.9.2NO MOVEMENT AUTO-ARMING
Your system can be programmed to send a report to your Central Monitoring Station and/or arm the
system if there is no activity in the area during a specified period of time. Your installer can set No
Movement Auto-Arming to function in either Regular or Stay arming mode.
4.0 DISARMING
When your system is disarmed, it deactivates any alarms in progress, and it deactivates the zones so the alarm will
not be triggered if zones are breached.
4.1ENTRY DELAY TIMER
Your installer will program designated entry points (i.e. the front door) with an Entry Delay Timer. This delay gives
you time to enter the armed premises and enter your code to disarm your system before the alarm is triggered.
4.2DISARMING AN ARMED SYSTEM
You can only disarm an area to which your User Access Code is assigned. User Access Codes with the “Arm Only”
(section 5.4 on page 11) option enabled cannot disarm an armed system.
Tp Disarm the system:
1. Enter your [
2. Press the [
(refer to section 2.3 on page 5).
ACCESSCODE].
DISARM] button. If you have access to more than one area, select the area(s) you wish to disarm
LCD Keypad 7
To Disarm a system in alarm:
1. Enter your [
ACCESSCODE].
2. In the case of a false alarm, call your Central Monitoring Station quickly to advise them of the false alarm.
In the case of a burglar alarm, leave the premises and call the Police from a safe place.
4.3ALARM MEMORY DISPLAY
Your system will record all the alarms that occurred during the last armed period. The zones in alarm will remain in
the Alarm Memory until the next time that area is armed.
When an alarm has occurred, the LCD screen will display “Alarms in Memory [
1. Press the [
2. Press the [
MEM] button. Each zone that was breached while armed will appear below “Alarm in:”.
CLEAR] button to exit the Alarm Memory Display.
5.0 ACCESS CODES
Access Codes allow access to the system. Your system supports up to 96 User Access Codes. Codes are given a
User Number between 02 and 96 (User Number 01 is the System Master Code). Your Installer will program User
Access Codes to be four, six, or variables of one to six digits in length. Each digit can be any value between zero
and nine. If your Installer programmed your system to accept a variable code length, you have to press the [
button after entering your User Access Code.
5.1SYSTEM MASTER CODE (Default 123456)
The System Master Code will give you access to all the features available on your system, as well as the ability to
add, modify, or delete any User Access Codes. We suggest that you change this code to prevent others from
accessing and changing options without authorization. Your Installer can set The System Master Code to be either
4 or 6 digits in length.
To change the System Master Code:
1. Enter the current [
2. Press the [0] button.
3. Press the [
ACC] button.
4. Enter the number [01].
5. Enter a [
6. Press the [
NEWCODE].
ENTER] button to save and exit.
SYSTEMMASTERCODE] (default: 123456).
MEM] to View”.
ENTER]
The System Master Code has access to all Access Control Doors and all Access Control
features at all times. Only the card’s serial number and the choice of arming method can be
changed. If the other options are manually changed, the System Master Code will immediately
revert to its original programming.
5.2DELETING USER ACCESS CODES
To delete User Access Codes, follow steps 1 to 5 in Figure 5.1 on page 9, but press the [CLEAR] button in step 5.
Once the information is erased, press the [
ENTER] button to save and exit.
5.3PROGRAMMING USER ACCESS COD ES
The System Master and Users with the Master feature can program User Access Codes with User Options and
Area Assignments. Figure 5.1 on page 9 describes the steps you would follow to program User Access Codes.
If the keypad emits a Rejection Beep at any point during the programming procedure, you may have chosen an
existing User Code or you do not have access to certain User Options (section 5.4) and Area Assignments (step 7
in Figure 5.1 on page 9). User’s with the Master feature can only assign User Options and Area Assignments that
they are assigned to. For example, if a User with the Master feature is assigned User Option 1 and Area 2, they can
only assign Options 1 and Area 2 to a User Access Code.
8 System Manager’s Manual
Figure 5.1: Programming User Access Codes
Enter your [ACCESSCODE] (System Master Code or User Access Code with Master
feature).
Press [0] to enter the Programming Menu.
From Programming Menu, press [
Enter the 2-digit User Number you want to program; press the [T] button to scroll the
list of codes then press [
Enter a User Code within the brackets.
screen.
NOTE: The User Code is a Personal Identification Number (P.I.N.).
Program the User Options by pressing the number on your keypad corresponding to the
User Option you wish to enable. The option is considered ON when the number
appears within the brackets
detailed description of the User Options refer to section 5.4 on page 11
ACC] once the desired code appears on the screen.
ACC].
Press the [S] button to reach the User Options
. Proceed to step 7 by pressing the [S] button. For a
.
Options [1] and [2] : Master Feature
[1] OFF = Master Feature disabled.
[1] ON, [2] OFF = User can only modify
User Access Codes.
[1] ON, [2] ON = User has full Master
rights. User can create, modify, and
program User options, User Access
Options and Area Assignments.
Option [3]: Duress
Option [4]: Bypass
Option [5]: Arm Only
Option [6]: Stay and Instant Arm
Option [7]: Force Arm
Option [8]: OFF - Access keypad’s
partitions only
Option [8]: ON - Access any partition
assigned to user
LCD Keypad 9