Installation Instructions for
980VISIR30O
Visir 30
Outdoor
GENERAL PRODUCT INFORMATION:
This product is suitable for wet locations.
This product can mount either to a 4” square electrical box with a round plaster ring or an octagon electrical box.
This product can be dimmed with a standard incandescent dimmer.
CAUTION - RISK OF FIRE
This product requires installation by a qualified electrician. Before installing be sure to read all instructions and TURNTHE POWER TO THE ELECTRICAL BOX OFF.
8538, 8539, 8540
1.0
Assemble the Crossbar
1A
2
NIPPLE
1
CROSSBAR
1
1
Screw the nipple into the crossbar.
2
2
Secure the nipple in place with one of the provided nuts.
NUT
Install the Fixture
2A
1 1
CAUTION: The glass diffuser is loose inside the
shade, remove the shade with caution.
1
Remove the two screws from the front of the fixture.
NOTE: Some adjustment to the nipple’s placement
on the crossbar may have to be made depending on the mounting situation.
2
Gently lift the shade assembly off of the fixture base.
1
Page 2
2B
NUT
FIXTURE BASE
3
Feed the fixture power lines first through the provided nut,
WASHER
then through the provided lock washer.
2C
2D
#8-32 SCREW
6 6
7
3
26
Secure the crossbar assembly to the electrical box using two #8-32 screws provided.
27
Pull the fixture power lines out of the electrical box.
4
4
FIXTURE BASE
CROSSBAR ASSEMBLY
4
Feed the fixture power lines through the hole in the fixture
5
base.
5
Then feed the fixtures power lines through the nipple on the crossbar assembly .
2E
4
10
8
3
8
Ground the crossbar in accordance with local electrical codes.
9
Connect the white fixture wire to the neutral power line wire with a wire nut.
9
10
Connect the black fixture wire to the hot power line wire with a wire nut.
2
Page 3
Install the Lamp and Shade
2F
11
Ensure that the fixture base is level and secure it tightly to the nipple with the lock washer and nut.
Gently push the excess power lines into the nipple.
12
2G
4
3A
LAMP
4
CAUTION: To reduce the risk of a burn or electric shock during lamping and re-lamping, disconnect the power to the fixture.
Use Type A19 Medium Base Lamp.
1
Screw the lamps into the sockets.
120 voltMAX 60 Watt
SOCKET
113
For wet locations, caulk around the base where the wall meets the fixture with waterproof construction sealant.
3B
3 3
2
Gently place the shade and diffuser onto the fixture base.
3
Replace the two screws and tightly secure the shade assembly.
NOTE: Ensure that the glass diffuser seats in the
fixture base correctly.
3
Page 4
SAVE THESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2012 LBL Lighting.All rights reserved. The "LBL Lighting" graphic is a registered trademark of LBL Lighting. LBL Lighting reserves the right to change specifications for product improvements without notification.
A Generation Brands Company