LBL Lighting TRANSDIR-SFE300 Installation Instructions Manual

Installation Instructions for
12 Volt 300 Watt Single Direct Power Feed Electronic Surface Mount Transformers
2-Circuit Monorail
980MR2DSFE30SMT
TRANSDIR-SFE300_-2
1.3
This product requires installation by a qualified electrician. Before installing be sure to read all instructions and DISCONNECT POWERTO THE ELECTRICAL BOX.
GENERAL PRODUCT INFORMATION:
This product is ETL listed and suitable only for indoor dry locations and approved for use at any height above the finished floor.
A typical installation is shown. Specific installation must be in accordance with local electrical codes.
This product may be dimmed only with a low voltage electronic dimmer. Using a dimmer not designed for low voltage electronic applications may work initially, but could eventually cause transformer failure and will void the warranty.
derated as indicated by the dimmer manufacturer.
This product is intended for use with LBL Lighting low voltage lighting systems only.
Read all instructions thoroughly. Read "Important Safety Information" on next column before proceeding with the installation.
The dimmer must be
Important Safety Information
Do not conceal or extend bus bar conductors through a building wall.
Do not install this lighting system in a damp or wet location.
To reduce the risk of fire and burns, do not install this lighting system where the uninsulated open bus bar conductors can be shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to curtains or similarly combustible materials.
Turn the electrical power off before modifying the lighting system in any way.
The fixtures used with the system must be identified to be used with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98 cubic centimeters).
Load the circuit of the surface mount transformer to no more than the maximum rated capacity as specified.
To reset the electronic surface mount transformer, turn the power off then on (main power, breaker panel, or wall switch).
1
Install the Transformer
1A
1
1
Remove the two #8-32 flat head screws to remove the crossbar.
1
1B
CROSSBAR
2
2
#8-32 SCREW
CROSSBAR
#8-32 FLAT HEAD SCREW
1C
4
CROSSBAR BRACKET
SAFETY WIRE
NOTE:All transformer power line wires must be connected to the same phase.
Hook the transformer safety wire onto the backplate bracket.
3
Connect the backplate to a suitable ground in accordance with
4
3
5
5
local electrical codes.
For each set of power line wires,connect the hot and neutral
5
wires to the black and white transformer wires, respectively.
1D
6
7
7
#8-32 SCREW
CAUTION: Turn the power to electrical box off!
Mount the crossbar to the electrical box with the provided
2
two #8-32 screws.
6
Slide the transformer onto the crossbar.
7
Align the transformer holes with the crossbar holes; replace and tighten the two #8-32 flat head screws.
2
Loading...