LBL Lighting Tear-SII Coax PCF User Manual

Page 1
Installation Instructions for
980TEARSIISPCF
Tear-SII Compact Fluorescent
Suspension
GP I :ENERAL RODUCT NFORMATION
This product is suitable for damp locations.
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
PF242_1BMPT
1.0
Install the Fixture
1A
#8-32 SCREW
1 1
11
Mount the crossbar to the electrical box with the two #8-32 screws.
CROSSBAR
1B
2
3
2
Insert the cord through the glass shade hole.
3
Carefully slide the glass shade down until it sits properly on the socket assembly.
CORD
GLASS SHADE
2
SOCKET ASSEMBLY
1
Page 2
1C
H
4
Determine the desired fixture height (From the bottom of glass shade to the top of canopy).
1E
PLASTIC STRAIN RELIEF
7
1/2"
MARKED LINE
7
Feed the cord inside the canopy so that the marked line is
8
exposed behind the canopy.
Hold the plastic strain relief 1/2" above the marked line and
8
tighten the set screw.
1F
1D
9
PLASTIC STRAIN
5
6
RELIEF
MARKED LINE
CORD
9
CAP
Slide the canopy up against the plastic strain relief and tighten the plastic cap on the bottom of the canopy.
5
Feed the cord into the canopy and plastic strain relief.
Adjust the fixture height and mark the cord below the canopy.
6
2
Page 3
1G
OUTER INSULATION
INNER WIRES
11
1I
15
14
4"
6”
10
Leave 6" of the cord behind the canopy for power connections and cut the excess cord.
11
From the end of the cord, strip 4" of the outer insulation.
1H
12
BALLAST
12
13
16
17
14
Connect the green wire to the ground screw and make sure
DOME CANOPY
that the crossbar is grounded in accordance with local electrical codes.
15
Connect the white ballast wire to the neutral power wire with a wire nut.
16
Connect the black ballast wire to the hot power wire with a wire nut.
17
Place the ballast inside of the dome canopy.
1J
FIXTURE WIRES
12
Connect one of the red ballast wires to one of the fixture wires (either one) with a wire nut. Cap the remaining red ballast wire with a wire nut.
Connect the yellow ballast wire to the other fixture wire with
13
a wire nut.
18 18
DOME CANOPY
FLAT HEAD SCREW
18
Line up the dome canopy holes with the crossbar holes.Install and tighten the flush-head screws to secure the dome canopy in place.
3
Page 4
Install the Lamp
2A
GLASS SHADE
CAUTION:To reduce the risk of a burn or electric shock during relamping, disconnect the power to the fixture.
SOCKET
2B
2
Use WattType Quad TubeMAX 13 G24Q-1 Base Compact Fluorescent Lamp.
GLASS SHADE
SOCKET
LAMP
11
Carefully lift up glass shade up to expose the socket.
2
Push the lamp completely into the socket.
3
Carefully lower the glass shade onto the socket.
SAVE THESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2014 LBL Lighting.All rights reserved. The "LBL Lighting" graphic is a registered trademark of LBL Lighting. LBL Lighting reserves the right to change specifications for product improvements without notification.