Installation Instructions for
980FSJRNEIP
Renée I
Fusion Jack™
GP I :ENERAL RODUCT NFORMATION
This product is ETL listed and suitable only for indoor dry locations
and approved for use at any height above the finished floor.
CAUTION - RISK OF FIRE
This product requires installation by a qualified
electrician. Before installing be sure to read all
instructions and TURNTHE POWER TO THE
ELECTRICAL BOX OFF.
Adjust the Fixture Height
HS283_
1.2
1A
FIXTURE COAXIAL
CABLE
GLASS SHADE
1B
ALLEN WRENCH
SET SCREW
CONNECTOR
3
Back out (do not remove) the set screw on tip of the
connector with the provided Allen wrench.
1C
ALLEN WRENCH
SET SCREW
4
3
SOCKET ASSEMBLY
1
Feed the fixture coaxial cable through the glass shade.
Slide the glass shade down the cord and rest it onto the
socket assembly.
2
Cut the coaxial cable to the desired length.
4
Back out (do not remove) the set screw on the conical
connector with the provided Allen wrench.
1

1D
5
5
Gently twist the end of the coaxial cable between thumb and
forefinger.
1E
SURFACE
PLATE
6
Tap the conical connector on a hard surface with the set screw
facing down, so the plate inside drops into place.
1H
ALLEN WRENCH
9
Look into the sight hole on the top of the connector to make
INNER WIRE
SIGHT HOLE
10
sure that the inner wire is contacting the end of the connector.
10
Hold the coaxial cable in place and tighten the set screw on tip
of the connector with the provided Allen wrench. Make sure
this set screw connection is tight.
1I
11
9
1F
7
CONICAL CONNECTOR
7
Feed and push the coaxial cable into the conical connector.The
coaxial cable will come to a stop point after being inserted
3/4" into the conical connector.
1G
8
WRINKLE ON OUTER
WRAPPED WIRE
8
Keep pushing the coaxial cable into the connector while
rotating the connector to ease feeding the inner wire into the
tip of the connector.The outer wrapped wire will start
wrinkling while being inserted another 1/2" into the connector.
OUTER WRAPPED
WIRE STOPS HERE
INNER WIRE
STOPS HERE
11
Firmly tighten the set screw on the conical connector.
1J
12
12
Pull the coaxial cable toward the fixture to smooth the
wrinkles.
2

Install the Lamp
2A
NOTE:To reduce the risk of a burn or electric shock
during relamping, disconnect the power to the fixture.
1
Lift the glass shade up to expose the socket.
2B
GLASS SHADE
SOCKET
2C
3
Lower the glass shade onto the socket assembly.
GLASS SHADE
GLASS SHADE
SOCKET
LAMP
NOTE:Use only your fingers and soft cloth to replace
the lamp.
Use Watt,Type XelogenMAX 50
(Xenon) Bi-Pin Lamp.
2
Push the lamp pins completely into the socket holes.
WARNING: RISK OF FIRE
Never replace a Xenon (Xelogen) lamp with a regular
Halogen lamp.A regular Halogen lamp requires a protective
glass shield.
3

SAVETHESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2013 LBL Lighting.All rights reserved. The "LBL Lighting" graphic is a
registered trademark of LBL Lighting. LBL Lighting reserves the right to
change specifications for product improvements without notification.
A Generation Brands Company