LBL Lighting Pendant compact fluorescent fixtures User Manual

Installation Instructions for
920TDPENDCF
Pendant Compact Fluorescent Fixtures
PENDANTS
GENERAL PRODUCT INFORMATION:
This product is suitable for damp locations.
This product can mount to either a 4" square electrical box with round plaster ring or an octagon electrical box.
295TDSFC_CF
Shorten the Pendant
1A 1B
#4-40 SCREW
1
CORD GRIP
Remove the #4-40 screws on canopy sides.
1
Remove the backplate from the dome cover.
2
3
Remove the cap from the cord grip.
BACKPLATE
3
2
BALLAST
1
DOME COVER
CAP
DOME COVER
MARKED POINT
CAP
CORD GRIP
7
4
6
NOTE: Refer to the instructions provided with the
pendant fixture to install the fixture shade (if needed) before proceeding with these steps.
4
Feed end of the pendant cord through the cap, and cord grip into the canopy.
5
Adjust the fixture height (from bottom of the fixture shade to top of the canopy) by moving the cord up or down.
6
When desired height is achieved, slightly tighten the cap.
7
From inside mark the cord right behind the cord grip for the strain relief location.
1
Install the Pendant
1C
STRAIN RELIEF
MARKED POINT
CORD GRIP
8
Loosen the cap and feed the cord through the strain
11
10
SLOT HEAD SCREW
8
DOME COVER
9
CAP
relief. Place the strain relief right above the marked point and tighten the slot head screw.
9
Slide the dome cover up against the strain relief and tighten the cap to cord grip.
10
For power connection, leave at least 6" of the cord exposed in the back of the dome canopy.
11
Cut off the excess cord with a sharp cutter.
CEILING
2A
#8-32 ROUND HEAD SCREW
#4-40 SCREW
1
Mount the backplate to the electrical box with the two
1
6
4
5
ELECTRICAL BOX
BACKPLATE
3
6
DOME COVER
#8-32 round head screws. Make sure that the backplate is grounded in accordance with local electrical codes.
2
Connect the ballast 120 volt black and white wires to the 120 volt hot and neutral power line wires with wire nuts respectively.
3
Connect the fixture bare uninsulated wire (green in SVT cord) to the backplate and the ballast ground wires with a wire nut.
2
1D
12
4"
12
From the end of the cord, strip the outer insulation 4" using a sharp knife and needlenose pliers.
not to cut inner wires.
13
Strip 1/4" of insulation from the inner insulated wires. (three inner insulated wires for standard SVT cord). The bare inner wire is the ground wire (green insulated wire in SVT cord).
Make sure
4
Connect the yellow and red ballast wires to the two remaining fixture wires (black and white in SVT cord) with wire nuts.
5
Place all wires, wire nut connections, and the ballast into the dome cover.
6
Replace the dome cover onto the backplate. Replace and tighten the two #4-40 screws.
SAVE THESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
847.410.4400
www.encompasslighting.com
© 2008 Encompass Lighting Group. All rights reserved. The "Encompass Lighting Group" graphic is a registered trademark of Encompass Lighting Group. Encompass Lighting Group reserves the right to change specifications for product improvements without notification.
A Generation Brands Company
2
Loading...