Installation Instructions for
75 Watt Magnetic Single Power Feed
Surface Mount Transformer
980MRLSFMLEDFSMT
TRANS-SFM75_
1.5
This product requires installation by a qualified
CAUTION - RISK OF FIRE
electrician. Before installing be sure to read all
instructions and TURNTHE POWER TO THE
ELECTRICAL BOX OFF.
GP I :ENERAL RODUCT NFORMATION
This product is ETL listed only when all the products used are
supplied by LBL Lighting, is suitable only for indoor dry locations
and approved for use at any height above the finished floor.
A typical installation is shown. Specific installation must be in
accordance with local electrical codes.
This product may be dimmed only with a low voltage magnetic
dimmer. Using a dimmer not designed for low voltage magnetic
applications may cause undesirable noise and potentially shorten
the life of the transformer.
This product is intended for use with LBL low voltage lighting
systems only.
Read all instructions thoroughly before beginning installation.
Important Safety Information
To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.
Do not install fixture assemblies closer than 6 inches to curtains or
similarly combustible materials.
Turn the electrical power off before modifying the lighting system in
any way.
The fixtures used with the system must be identified to be used
with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).
Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.
1
Install the Mounting Plate
Adjust the Height
1A
SCREW
TRANSFORMER
HOUSING
1
Separate the back plate from the transformer housing by
unscrewing and removing the screws.
1B
MOUNTING PLATE
MOUNTING
PLATE
2A
TRANSFORMER
HOUSING
POWER FEEDWIRES
1
1
STRAIN RELIEF
SET SCREW
ELECTRICAL
BOX
#8-32 SCREW
2
Mount the backplate to the electrical box with the two #8-32
#8-32 SCREW
round head screws.
1
Take note of the wire connections and remove the
transformer wire nuts on the power feed wires.
Loosen the set screws on the strain relief and pull out
2
the power feed wires.
63
Cut the end power feed wires to the desired length.
64
With a sharp knife cut 1" from the end of the wire web
and separate the wires 8" from each other.
Push the power feed wires through the strain reliefs
65
leaving at least 6” of cord in the back of the transformer
housing for wire connections and tighten the set
screws.
66
Strip 1/2" off the wire ends and reconnect the power
feed wires to their original connections.
2