LBL Lighting MO Rmt Mag Xfmr 300w User Manual

Installation Instructions for
120 Volt to 12 Volt Single Feed 300W Remote Magnetic Transformers
TRANSFORMERS
250AT300T
950RM30012
1.4
This product requires installation by qualified electrician. Before installing be sure to read all instructions and TURN THE POWER TO THE
ELECTRICAL BOX OFF.
CAUTION: RISK OF FIRE
GENERAL PRODUCT INFORMATION:
This transformer is ETL listed for use with low voltage lighting systems of brands offered by Encompass Lighting Group.
A typical installation is shown. Specific installation must be in accordance with the local electrical codes.
This product may be dimmed only with a low voltage magnetic dimmer. Using a dimmer not designed for low voltage magnetic applications may work initially, but could eventually cause transformer failure and will void the warranty.
dimmer must be derated as indicated by the dimmer manufacturer.
This product is intended for use with Encompass Lighting Group brands of low voltage lighting systems only.
During installation, make sure all power connections are tight.
Read all instructions thoroughly. Read "Important Safety Information" on next column before proceeding with the installation.
The
Important Safety Information
Do not conceal or extend bus bar conductors through a building wall.
Do not install this lighting system in a damp or wet location.
To reduce the risk of fire and burns, do not install this lighting system where the uninsulated open bus bar conductors can be shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to curtains or similarly combustible materials.
Turn the electrical power off before modifying the lighting system in any way.
The fixtures used with the system must be identified for use with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98 cubic centimeters).
To Reduce Risk of Fire
transformer for the system as described in this installation instruction.
Load the circuit of the remote transformer to 300 Watt.
, it is important to wire the remote
MAXIMUM
1
Install the Remote Transformer
1A
1
COM X1 X2 X3 X4
TRANSFORMER BRACKET
PHILLIPS SCREW
1B
NEUTRAL POWER LINE WIRE
COM X1 X2 X3 X4
5
6
HOT POWER LINE WIRE
7
2
TRANSFORMER
TRANSFORMER COVER
1
BRACKET
NOTE: In order to use small gage wires from the
transformer to the electrical box, it is recommended to install the remote transformer near (if possible) the electrical box. See "Low Voltage Wire Size Table" below.
1
Mount the transformer to a solid surface using the keyhole slot on the mounting bracket (hardware not included).
Remove the transformer cover by loosening the two
2
Phillips screws on the side of the transformer.
2
4
Install a conduit and power line wires from the panel to
3
3
CONDUIT
remote transformer.
4
Do not
connect the power line wires to the panel at this
time.
5
Connect the 120V black transformer wire to the hot power line wire with a wire nut.
6
Connect the 120V white transformer wire to the neutral power line wire with a wire nut.
Connect the ground wire to the green wire or stud
7
labeled “ground” in the console.
LOW VOLTAGE WIRE SIZE TABLE
TRANSFORMER WATTAGE
300 WATT #6 GA #4 GA #1 GA #1/0 GA #3/0 GA#10 GA
WIRE SIZE FOR5FT
WIRE SIZE FOR 6-15 FT
WIRE SIZE FOR 16-20 FT
2
WIRE SIZE FOR 21-40 FT
WIRE SIZE FOR 40-60 FT
WIRE SIZE FOR 61-90 FT