LBL Lighting MO Rmt Elec Xfmr 150w User Manual

Installation Instructions for
950RM15012EL
120 Volt to 12 Volt DC Single Feed 150W Remote Electronic Transformers
TRANSFORMERS
CAUTION: RISK OF FIRE
This product requires installation by qualified electrician. Before installing be sure to read all instructions and TURN THE POWER TO THE
ELECTRICAL BOX OFF.
1.0
1.0
1.2
GP I :ENERAL RODUCT NFORMATION
This transformer is ETL listed for use with low voltage lighting systems of brands offered by Encompass Lighting Group.
This product is suitable only for indoor dry locations and approved for use at any height above the finished floor.
A typical installation is shown. Specific installation must be in accordance with the local electrical codes.
This product may be dimmed only with a low voltage electronic dimmer. Using a dimmer not designed for low voltage electronic applications may work initially, but could eventually cause transformer failure and will void the warranty.
The dimmer must be derated as indicated by the dimmer manufacturer.
This product is intended for use with Encompass Lighting Group brands of low voltage lighting systems only.
During installation, make sure all power connections are tight.
Read all instructions thoroughly. Read "Important Safety Information" on next column before proceeding with the installation.
Important Safety Information
Do not conceal or extend bus bar conductors through a building wall.
Do not install this lighting system in a damp or wet location.
To reduce the risk of fire and burns, do not install this lighting system where the uninsulated open bus bar conductors can be shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to curtains or similarly combustible materials.
Turn the electrical power off before modifying the lighting system in any way.
The fixtures used with the system must be identified for use with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98 cubic centimeters).
To Reduce Risk of Fire, it is important to wire the remote transformer for the system as described in this installation instruction.
Load the circuit of the remote transformer to 150MAXIMUM Watt.
1
Install the Remote Transformer
1A1A
TRANSFORMER COVER
PHILLIPS SCREW
1
1 1
1A
1B
1
4
CONDUIT
7
3
6
2
2
NOTE: In order to use small gage wires from the
transformer to the electrical box, it is recommended to install the remote transformer near (if possible) the electrical box. See "Low Voltage Wire Size Table" below.
1
Remove the four Phillips screws to remove the transformer cover.
2
Secure the transformer housing in place (hardware not included).
Install a conduit and power line wires from the panel to
3
the remote transformer.
4
Do not connect the power line wires to the panel at this time.
5
Make sure the transformer housing is grounded in accordance with local electrical codes.
6
Connect the transformer white wire to the neutral power line wire with a wire nut.
7
Connect the transformer black wire to the hot power line wire with a wire nut.
2
Loading...
+ 2 hidden pages