LBL Lighting MO Mini Direct-Feed Surf Elec Xfmr 300w User Manual

Installation Instructions for
980MRLMSET
Mini Surface Electronic Transformer
GP I :ENERAL RODUCT NFORMATION
This product is ETL listed and suitable only for indoor dry locations and approved for use at any height above the finished floor.
A typical installation is shown. Specific installation must be in accordance with local electrical codes.
This product may be dimmed only with a low voltage electronic dimmer. Using a dimmer not designed for low voltage electronic applications may work initially, but could eventually cause transformer failure and will void the warranty.
dimmer manufacturer.
This product is intended for use with LBL Lighting low voltage lighting systems only.
The dimmer must be derated as indicated by the
TRANSDIRMNE300_
CAUTION - RISK OF FIRE
This product requires installation by a qualified electrician. Before installing be sure to read all instructions and TURNTHE POWER TO THE ELECTRICAL BOX OFF.
1.0
Read all instructions thoroughly. Read "Important Safety Information" on page 3 before proceeding with the installation.
Important Safety Information
To reduce the risk of fire and burns, do not install this lighting system where the uninsulated open bus bar conductors can be shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to curtains or similarly combustible materials.
SAVETHESE INSTRUCTIONS!
Turn the electrical power off before modifying the lighting system in any way.
The fixtures used with the system must be identified for used with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98 cubic centimeter).
Load the circuit of the remote transformers to no more than the maximum rated capacity as specified.
To reset the electronic surface transformer, turn the power off then on (main power, breaker panel, or wall switch).
1
1
Install the Transformer
1A
CANOPY
1
Separate the mounting plate from the transformer by
MOUNTING PLATE
removing the two screws.
1B
#8-32 SCREW#8-32 SCREW
2
Attach the mounting plate to the electrical box using the two #8-32 screws provided.
1C
3
5
4
1D
7
Reattach the transformer to the mounting plate by
SCREWSCREW
securing it with the two screws.
Connect the Transformer to the MonoRail
2A
1/16 ALLEN WRENCH
2
4
#6-32 SET SCREW
3
RAIL BUSHING
SECTION OF MONORAIL
1
Unscrew the rail bushing from the bushing base.
3/16 ALLEN WRENCH
1
5
BUSHING BASE
3/8-24 SET SCREW
3
Connect the mounting plate ground wire to a suitable ground in accordance with local electrical codes.
4
Connect the white transformer wire to the neutral power line wire with a wire nut.
5
Connect the black transformer wire to the hot power line wire with a wire nut.
6
Place all wires and wire nut connections inside the electrical box.
2
Loosen the #6-32 set screw on the bushing base with the 1/16 Allen wrench.
3
Place the MonoRail into the rail bushing. Screw the bushing base to the rail bushing tight.
4
Tighten the #6-32 set screw on the bushing base with the 1/16 Allen wrench.
5
Tighten the 3/8-24 set screw on the bottom of the rail bushing with the 3/16 Allen wrench.