Installation Instructions for
Modular Medium and Large (T8 Fluorescent)
Outdoor
GP I :ENERAL RODUCT NFORMATION
This product can mount to either a 4" square electrical box with round plaster ring or an octagon electrical box.
This product is suitable for wet locations.
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
980MODUMLT8
PW5_17L_HEW,
PW5_25L_HEW
1.0
Install the Fixture Base
1A 1B
1
1
1
1
1
1
3 3
3 3
3 3
1
Remove all the cap screws around the perimeter of the cover.
2
Pull the cover off of the housing.
3
Remove the six Phillips-head screws on the reflector.
4
Lift the reflector out of the housing.
1
1C
NIPPLE
1E
#8-32 SCREW
CROSSBAR ASSEMBLY
5
Feed the power line wires through the crossbar nipple.
Feed the power line wires through the crossbar nipple.
6
Mount the crossbar assembly to the electrical box holes with
Mount the crossbar assembly to the electrical box holes with the two #8-32 screws provided.
the two #8-32 screws provided.
7
Connect the crossbar to a suitable ground according to local
Connect the crossbar to a suitable ground according to local electrical codes.
electrical codes.
5
6
6
ELECTRICAL BOX HOLE
1D
9
11
11
ANCHOR
10
Install the anchors for the lag bolts at the points marked on
10
the wall.
11
Apply caulk around the anchor points and the electrical box.
1F
8
9
8
Place the housing on the crossbar nipple.
9
Mark the location of the end holes in the housing onto the wall and remove the housing.
13
12
13
RUBBER WASHER
LAG BOLT
12
Mount the housing to the crossbar nipple with the nut and
METAL WASHER
lock washer provided.
13
Anchor the housing to the wall with lag bolts through the metal and rubber washers provided.
Do not overtighten the lag bolts.
2