Installation Instructions for
Modular Small (Compact Fluorescent)
Outdoor
GP I :ENERAL RODUCT NFORMATION
This product can mount to either a 4" square electrical box with round plaster ring or an octagon electrical box.
This product is suitable for wet locations.
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
980MODUSCF
PW119_, PW115_
PW120_,
1.0
Install the Fixture Base
1A 1B
1
1
1
1
3
3
3
3
1 3
Remove all the cap screws around the perimeter of the cover.
2
Pull the cover off of the housing.
1
Remove the four Phillips-head screws on the reflector.
4
Lift the reflector out of the housing.
Page 2
1C
NIPPLE
1D
#8-32 SCREW
CROSSBAR ASSEMBLY
5
Feed the power line wires through the crossbar nipple.
6
Mount the crossbar assembly to the electrical box holes with
5
6
6
ELECTRICAL BOX HOLE
the two #8-32 screws provided.
7
Connect the crossbar to a suitable ground according to local electrical codes.
8
Apply caulk around the electrical box.
1E
8
9
9
Mount the housing to the crossbar nipple with the nut and lock washer provided.
2
Page 3
Install the Lamps
1F
10
11
10
Connect the hot power line wire to the black fixture wire with a wire nut.
11
Connect the neutral power line wire to the white fixture wire with a wire nut.
2A
Use Volt, Type BT15
MAX 60120 Watt
Medium Base Lamp.
1
Screw the lamps into the sockets.
12
Reinstall the reflector into the housing and tighten all six screws to hold it in place.
2
Reinstall the front cover on to the housing and fully tighten all six cap screws. Tighten all the cap screws evenly to prevent the cover from flexing, which could cause the glass to break.
3
Page 4
Install the Decorative Cover
3A 3B
2
2
2
INDUSTRIAL
AND TUBULAR
1 2
Slide the decorative cover onto the fixture base. For and decorative covers (left), place theIndustrial Tubular
acrylic shade inside the frame and slide the cover on from the front.
For decorative covers (right),line up the tracks onNewYork the fixture with the guides inside the cover, and slide the cover on from the top.
NEW YORK
2
For and decorative covers, line up theIndustrial Tubular holes in the decorative cover and acrylic shade with the holes in the fixture base.Attach screws through these holes to secure the cover.
For decorative covers (shown),line up the holes inNewYork the decorative cover with the holes in the fixture base.Attach screws through these holes to secure the cover.
SAVETHESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300