Installation Instructions for
75 Watt Magnetic Single Direct Power Feed
980MRLSFMLEDSMT
Surface Mount Transformers
Monorail
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
GP I :ENERAL RODUCT NFORMATION
TRANSDIR-SFM75_
Important Safety Information
1.2
This product is ETL listed only when all the products used are
supplied by LBL Lighting, is suitable only for indoor dry locations
and approved for use at any height above the finished floor.
A typical installation is shown. Specific installation must be in
accordance with local electrical codes.
This product may be dimmed only with a low voltage magnetic
dimmer. Using a dimmer not designed for low voltage magnetic
applications may cause undesirable noise and potentially shorten
the life of the transformer.
This product is intended for use with LBL low voltage lighting
systems only.
Read all instructions thoroughly before beginning installation.
To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.
Do not install fixture assemblies closer than 6 inches to curtains or
similarly combustible materials.
Turn the electrical power off before modifying the lighting system in
any way.
The fixtures used with the system must be identified to be used
with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).
Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.
1
Install the Transformer
1A1A
DOME
COVER
SCREW
1 1
1
Remove the screws on the side of the transformer dome
cover and lift the cover off of the backplate.
1A1B
4
3
2
1A1C
BACKPLATE
5
5
#8-32 SCREW
5
Mount the backplate to the electrical box with two #8-32
screws.
1A1D
BACKPLATE
CAUTION: Disconnect power to the electrical box!
2
Connect the green wire to a suitable ground in accordance
with local electrical codes.
3
Connect the black transformer wire to the hot power line
wire with a wire nut.
4
Connect the white transformer wire to the neutral power line
wire with a wire nut.
SCREW
6
Reattach the dome cover to the backplate with the screws.
6
6
2