Lava Heat Venetian Owner's Manual

WWW.LAVAHEAT.COM
41,000BTU
PROPANE
Owner’s Manual
1
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent or home.
DANGER
CARBON MONOXIDE HAZARD
WARNING:
Improper installation, adjustment, alteration, services or maintenance can cause injury, death or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
WARNINGS AND CAUTIONS
Certification Height Overall Reflector Diameter Rated Heat Input Fuel GasSupply Manifold Pressure Safety Features GasSupplyPressure
Specifications
CSA
90.5inches
33.5inches 4000 BTU/HR Propane-LP 20-LbLP-Gascylinder
11.0inchesW.C Flamefailuredevice,anti-tilts
witch
Max250 PSI, Min5 PSI
2
WARNINGS AND CAUTIONS
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, NFPA58 Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2
The heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the heater.
Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater.
Prior to use, check for damaged parts such as hoses, regulators, burner.
All leak tests should be done with a soapy solu­tion. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKAGE.
The propane hose with regulator assembly shall be located out of pathways where people may trip over it or in areas where the hose will not be subject to accidental damage.
Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater.
Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a qualified service person.
More frequent cleaning may be required as necessary. It is imperative that control compartment, burners and circulating air passageways of the heater be kept clean.
Keep the appliance area clear and free from combustible materials, gasoline and other flam­mable vapors and liquids.
Do not obstruct the flow of combustion and venti­lation air.
Keep the ventilation opening(s) of the cylinder enclosure free and clear from debris.
This appliance shall be used only in a well­ventilated space and shall not be used in a build­ing, garage or any other enclosed area.
An appliance may be installed with shelter no more inclusive than: With walls on all sides, but with no overhead cover. Within a partial enclosure which includes an overhead cover and no more than two side walls. These side walls may be parallel, as in a breezeway, or at right angles to each other.
NOTE: PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
3
WARNINGS AND CAUTIONS
Within a partial enclosure which includes an overhead cover and three side walls, as long as 30 percent or more of the horizontal periphery of the enclosure is permanently open.
This appliance requires 9 kg (20 lb) LP-gas supply cylinder.
The LP-gas supply cylinder to be used must be: Constructed and marked in accordance with the Specifications for LP-gas cylinders of the U.S. Department of Transportation (DOT), or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Com­mission, CAN/CSA-B339, as applicable; provided with a listed overfilling prevention device; and provided with a cylinder connection device compatible with the connection for the appliance.
The cylinder be disconnected when the appli­ance is not is use.
Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance.
A cylinder must be stored outdoors in a well­ventilated area out of the reach of children. A disconnected cylinder must have dust caps tightly installed and must not be stored in a build­ing, garage or any other enclosed area.
The pressure regulator and hose assembly sup­plied with the appliance must be used, replace­ment pressure regulators and hose assemblies must be those specified by the appliance manu­facturer.
Do not store a spare LP-gas cylinder under or near this appliance;
Never fill the cylinder beyond 80 percent full;
Do not clean the heater with cleaners that are combustible or corrosive.
NOTE:PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
This heater is designed to operate with a standard 20-Ib propane cylinder with Approved Cylinder Connection.
Perform a leak test with a soapy solution:
1. To check gas connections.
2. After connecting a new cylinder.
3. Upon re-assembly after disassembly.
4
TABLE OF CONTENTS
WARNINGS AND CAUTIONS...................................................................................................... 1
CONTENTS...................................................................................................................................4
PACKAGE CONTENT....................................................................................................................5
HARDWARE CONTENTS / PREPARATION................................................................................6
ASSEMBLY INSTRUCTIONS........................................................................................................7
SAFETY CHECK..........................................................................................................................11
OPERATION INSTRUCTIONS....................................................................................................13
LOCATING HEATER FOR USE..................................................................................................16
MAINTENANCE/STORAGE.........................................................................................................17
TROUBLESHOOTING.................................................................................................................19
THREE-YEAR LIMITED WARRANTY .........................................................................................20
5
PACKAGE CONTENTS
Part Description Quantity
A
B C
D
F
E
1pc 1set 1set 1pc
1set
1set
1pc
Part Description Quantity
G
H
1pc
Decorative cap Reflector Burner head assembly Pole
Pole decorative cap Base assembly
Cylinder chain
Regulator
A
B
C
D
E
F
G
H
6
HARDWARE CONTENTS
AA M6 decorative nut 1 pc
BB M6x38 double pointed bolt 1 pc
CC M6 nut 3 pcs
DD ø6 washer 6 pcs
EE M6x70 double
pointed bolt 3 pcs
FF ø5 washer 10 pcs
GG M5x10 Bolt 10 pcs
HH
II M3x6 Bolt 6 pcs
Reflector connecter 3 pcs
Part Description Quantity Picture
PRECAUTIONSPRECAUTIONS
TOOLS NEEDED: (NOT INCLUDED)
Adjustable opening wrench Philips screwdriver Estimated time for assembly: 30 minutes.
PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and diagram above. If any part is missing or damaged, do not attempt to assemble the product. Contact customer service for replacement parts.
Loading...