Questions, problems, missing / replacement parts? Before returning to your retailer,
call our customer service department at 1.888.779.5282, 10 a.m.- 6:00 p.m., 3ST,
Monday-Friday
RUHPDLOFV#ODYDKHDWFRP.
WARNINGS AND CAUTIONS
DANGER
This appliance can produce carbon monoxide
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such
as a camper, tent or home.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury,
death or property damage. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
CARBON MONOXIDE HAZARD
SPECIFICATION
CertificationCSA
Height 70.87" (1.80 m)
Rated heat input 51,000 BTU/hr
Gas type LPG
Gas Supply 20 lb (9 kg) LP gas cylinder
Manifold pressure 11" W.C.
Diameter of injector 1/13" (1.90 mm)
Safety features Flame failure device, anti-tilt switch
Gas supply pressure Max. 250 PSI, Min. 5 PSI
2
NOTE:PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
WARNINGS AND CAUTIONS
The installation must conform with local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54,
NFPA58 Natural Gas and Propane Installation
Code, CSA B149.1, or Propane Storage and
Handling Code, B149.2
The heater, when installed, must be electrically
grounded in accordance with local codes or, in
the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1.
Prior to use, check for damaged parts such as
hoses, regulators, pilot or burner.
All leak tests should be done with a soapy solution. NEVER USE AN OPEN FLAME TO
CHECK FOR LEAKAGE.
The propane hose with regulator assembly shall
be located out of pathways where people may
trip over it or in areas where the hose will not be
subject to accidental damage.
Children and adults should be alerted to
the hazards of high surface temperatures
and should stay away to avoid burns or
clothing ignition.
Any guard or other protective device
removed for servicing the heater must be
replaced prior to operating the heater.
Installation and repair should be done by
a qualified service person. The heater
should be inspected before use and at
least annuallyby aqualified service
person.
More frequent cleaning may be required
as necessary. It is imperative that control
compartment, burners and circulating air
passageways of the heater be kept clean.
Keeping the appliance area clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
Not obstructing the flow of combustion and ventilation air.
Keeping the ventilation opening(s) of the cylinder enclosure free and clear from debris.
This appliance shall be used only in a wellventilated space and shall not be used in a building, garage or any other enclosed area.
Youngchildrenshouldbecarefully
supervised when they are in the area of
the heater.
Clothing or other flammable materials
should not be hung from the heater, or
placed on or near the heater.
An appliance may be installed with shelter no
more inclusive than:
With walls on all sides, but with no overhead
cover.
Within a partial enclosure which includes an
overhead cover and no more than two side
walls. These side walls may be parallel, as in a
breezeway, or at right angles to each other.
3
WARNINGS AND CAUTIONS
NOTE:PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
Within a partial enclosure which includes an
overhead cover and three side walls, as long as
30 percent or more of the horizontal periphery of
the enclosure is permanently open.
This appliance requires 9kg(20lb) LP-gas supply
cylinder.
The LP-gas supply cylinder to be used must be:
Constructed and marked in accordance with the
Specifications for LP-gas cylinders of the U.S.
Department of Transportation (DOT); or the
Standard for Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods and Commission, CAN/CSA-B339, as applicable;
Provided with a listed overfilling prevention
device; and provided with a cylinder connection
device compatible with the connection for the
appliance.
The pressure regulator and hose assembly supplied with the appliance must be used, replacement pressure regulators and hose assemblies
must be those specified by the appliance manufacturer.
Do not store a spare LP-gas cylinder under or
near this appliance;
Never fill the cylinder beyond 80 percent full;
Do not clean the heater with cleaners that are
combustible or corrosive.
Place the dust cap on the cylinder valve outlet
whenever the cylinder is not in use. Only install
the type of dust cap on the cylinder valve that is
provided with the cylinder valve. Other types of
caps or plugs may result in leakage of propane.
The cylinder be disconnected when the appliance is not in use.
Storage of an appliance indoors is permissible
only if the cylinder is disconnected and removed
from the appliance.
A cylinder must be stored outdoors in a wellventilated area out of the reach of children. A
disconnected cylinder must have dust caps
tightly installed and must not be stored in a building, garage or any other enclosed area.
4
WARNINGS AND CAUTIONS
NOTE: PLEASE READ THE FOLLOWING SAFETY RULES:
Perform a leak test with a soapy solution:
1. To check gas connections.
2. After connecting a new cylinder.
3. Upon re-assembly after disassembly.
This heater is designed to operate with a standard 20 Ib propane cylinder with Approved Cylinder
Connection.
PREPARATION
Before beginning assembly of product, make sure all parts are present. If any part is missing or
damaged, do not attempt to assemble the product. Contact customer service for replacement parts.
5
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.