Lava Heat LHI110, LHI109 User Manual

Model(PEHU
Owner’s Manual
Read these instructions before lighting this appliance.
If you smell gas:
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department.
Outdoor Flame Heater
DANGER
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
WARNING
For Outdoor Use Only.
Installer: Leave this manual to the
owner for future use.
Consumer: Please keep this manual
for future reference.
This appliance must be installed in accordance to municipal and local regulations.
Gas-Fired Outdoor Infrared Patio Heaters
Questions, problems, missing / replacement parts? Before returning to your retailer,
call our customer service department at 1.888.779.5282, 10 a.m.- 6:00 p.m., 3ST,
Monday-Friday
RUHPDLOFV#ODYDKHDWFRP.
WARNINGS AND CAUTIONS
DANGER
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent or home.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury, death or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
CARBON MONOXIDE HAZARD
SPECIFICATION
Certification CSA
Height 70.87" (1.80 m)
Rated heat input 51,000 BTU/hr
Gas type LPG
Gas Supply 20 lb (9 kg) LP gas cylinder
Manifold pressure 11" W.C.
Diameter of injector 1/13" (1.90 mm)
Safety features Flame failure device, anti-tilt switch
Gas supply pressure Max. 250 PSI, Min. 5 PSI
2
NOTE:PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
WARNINGS AND CAUTIONS
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, NFPA58 Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2
The heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
Prior to use, check for damaged parts such as hoses, regulators, pilot or burner.
All leak tests should be done with a soapy solu­tion. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKAGE.
The propane hose with regulator assembly shall be located out of pathways where people may trip over it or in areas where the hose will not be subject to accidental damage.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater.
Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a qualified service person.
More frequent cleaning may be required as necessary. It is imperative that control compartment, burners and circulating air passageways of the heater be kept clean.
Keeping the appliance area clear and free from combustible materials, gasoline and other flam­mable vapors and liquids.
Not obstructing the flow of combustion and venti­lation air.
Keeping the ventilation opening(s) of the cylin­der enclosure free and clear from debris.
This appliance shall be used only in a well­ventilated space and shall not be used in a build­ing, garage or any other enclosed area.
Young children should be carefully supervised when they are in the area of the heater.
Clothing or other flammable materials should not be hung from the heater, or placed on or near the heater.
An appliance may be installed with shelter no more inclusive than: With walls on all sides, but with no overhead cover. Within a partial enclosure which includes an overhead cover and no more than two side walls. These side walls may be parallel, as in a breezeway, or at right angles to each other.
3
WARNINGS AND CAUTIONS
NOTE:PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
Within a partial enclosure which includes an overhead cover and three side walls, as long as 30 percent or more of the horizontal periphery of the enclosure is permanently open.
This appliance requires 9kg(20lb) LP-gas supply cylinder.
The LP-gas supply cylinder to be used must be: Constructed and marked in accordance with the Specifications for LP-gas cylinders of the U.S. Department of Transportation (DOT); or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Com­mission, CAN/CSA-B339, as applicable;
Provided with a listed overfilling prevention device; and provided with a cylinder connection device compatible with the connection for the appliance.
The pressure regulator and hose assembly sup­plied with the appliance must be used, replace­ment pressure regulators and hose assemblies must be those specified by the appliance manu­facturer.
Do not store a spare LP-gas cylinder under or near this appliance;
Never fill the cylinder beyond 80 percent full;
Do not clean the heater with cleaners that are combustible or corrosive.
Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
The cylinder be disconnected when the appli­ance is not in use.
Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance.
A cylinder must be stored outdoors in a well­ventilated area out of the reach of children. A disconnected cylinder must have dust caps tightly installed and must not be stored in a build­ing, garage or any other enclosed area.
4
WARNINGS AND CAUTIONS
NOTE: PLEASE READ THE FOLLOWING SAFETY RULES:
Perform a leak test with a soapy solution:
1. To check gas connections.
2. After connecting a new cylinder.
3. Upon re-assembly after disassembly. This heater is designed to operate with a standard 20 Ib propane cylinder with Approved Cylinder
Connection.
PREPARATION
Before beginning assembly of product, make sure all parts are present. If any part is missing or damaged, do not attempt to assemble the product. Contact customer service for replacement parts.