Lava Computer 2SP-550 User Manual 2

Lava 2SP-550
Installation Manual
SERIAL2
1
SERIAL
T
POR
PARALLEL
MADE IN
LAVA COM PUT ERS
LAVA2SP
P.N.MOKO L37.5
Rev.B00
Hardware Set-Up
Serial 2 Settings
Serial 1 Settings
Serial IRQ Settings
Serial Settings
COM 1
(03F8h)*
Default for
Serial1
COM 2
(02F8h)**
Default for
Serial2
Serial IRQ Settings
Parallel Settings
COM 3
(03E8h)
COM 4
(02E8h)
Serial 2
Serial 1
34211 7 51215 10
Parallel Mode Settings
16C552
LPT 1
(0378h)
(default)
LPT 2
(0278h)
Bi-directional
Serial 2
Serial 1
Parallel Port
Parallel Settings
IRQ 5
IRQ 7
(default)
Parallel
Mode Settings
(default)
Output
2SP-550 Configuration
Serial Configuration
1. Determine the number of serial ports installed in your system. Each serial port will have an unique "COM" designation.Configure the ports of the 2SP­550 for two unused COM addresses.
2. Determine which IRQ's (interrupts) are free in your system.Configure each serial port on the 2SP-550 for an unused IRQ. Although some devices allow sharing of IRQ's, this is not recommended.
3a. For Serial 1, install the jumper above the number corresponding to the
desired IRQ, so that it covers the pin in the bottom row and the pin in the middle row.
3b. For Serial 2, install the jumper above the number corresponding to the
desired IRQ, so that it covers the pin in the top row and the pin in the middle row.
Do not install more than one IRQ jumper per serial port.
Parallel Configuration
1. Determine the number of parallel ports installed in your system. Each parallel port will have an unique "LPT" designation. Configure the port of the 2SP­550 for an unused LPT address (e.g.If you have a parallel port installed as LPT 1 using hexidecimal address 0378, configure the 2SP-550 as LPT 2 using address 0278h).
2a. Configure the parallel port for an unique IRQ, if required.Many applications
do not require an IRQ assignment for operation.Consult the documentation accompanying your software and/or operating system.
2b. Typically, a parallel port configured for LPT 1 at address 0378h, will be set for
IRQ 7 and a port configured for LPT 2 at address 0278h, will be set for IRQ 5.
3. The 2SP-550 supports two parallel modes: Output (SPP, 4-bit,"nibble") & Bi­directional (8-bit, "byte," PS/2 compatible).
Note: To disable a port,remove the jumper from both of the IRQ and
the corresponding COM or LPT jumper configuration pins.
Lava
Technical Support
9:00 am to 5:30 pm Monday to Friday (Eastern Time)
Tel: +416 674-5942
Fax:+ 416 674-8262
E-mail: tech@lavalink.com
Internet: www.lavalink.com
Lava Computer MFG Inc.
This device complies with part 15 of the FCC Rules. Operation is subject
to the following conditions: (1)This device may not cause harmful interference,
and (2) this device must accept any interference received,including interference
Lava Computer MFG Inc.908 Niagara Falls Blvd. #629.North Tonawanda NY 14120-2060
that may cause undesired operation.
Loading...