rotate the "Mist regulating Switch" from “Min" to "Max", and check whether mist
is normal. Power off the product immediately once there are some abnormalities.
Page 9
@2012.11-V1.1Aviator X2 Page 9 of 15
n Trial Operation
After installation, fill the water tank with water to the depth of 20 cm. Then you can try to
operate it.
Manual Adding Water:
Insert a hose to the tank through the hole (as shown). DON’T go away while adding water.
You can view the water level through the window (as shown). Stop adding water when it
reaches the highest level.
Window—view
water level
Automatic Adding Water:Please remove the choke plug and then connect the weaved hose
(at the bottom of the tank) to water supply; turn on the faucet and begin adding water; there is
a water level sensor inside the tank. When the tank is full, it will stop inflowing. When water
reaches the lowest level, it would restart inflowing automatically.
When the weaved pipe is apart from the water supply, please screw on the choke plug so as to
avoid water leakage
Hole for manual
water adding
choke plug
Page 10
@2012.11-V1.1Aviator X2 Page 10 of 15
Electric Control Box:
Swaying Switch
Misting Switch
Blowing Switch
Way of trial operation:
1. Power on, switch to the Speed 1. The product would begin blowing. Observe whether the
fan blows normally, by switching the speed 1 / 2 / 3.
2. Press the button “MIST”, the centrifugal disc would begin rotating and producing mist.
View whether there is any difference of the mist quantity while rotating the “Mist
regulating switch” from “Min” to “Max”.
Page 11
@2012.11-V1.1Aviator X2 Page 11 of 15
electric shock or fire hazard
■ Attentions:
Please carefully read the following items:
Caution:The product MUST be connected to the power with leakage protection device.
¨ Make sure firmly plugged
Otherwise, it may cause
¨ Please do not use the same
socket with other equipment, or
use extended cable.
Otherwise, it may cause electric
shock or fire hazard.
¨ Be sure not to take off the plug
while operating.
Otherwise, it may cause electric
shock or fire hazard.
¨ Be sure not to operate the
product with a wet hand.
Otherwise, it may cause electric
shock or fire hazard.
¨ Be sure not to damage or use
unspecified power line.
Otherwise, it may cause electric
shock or fire hazard.
¨ Don’t take off the plug by
pulling the power cord.
Otherwise, it may cause electric
shock or fire hazard.
¨ Power off while adding water or
cleaning the product.
¨ The voltage used can be
fluctuated within the rated
voltage range. Too low or too
high voltage may damage the
motor.
Power off the product immediately
once there are some abnormalities.
Page 12
@2012.11-V1.1Aviator X2 Page 12 of 15
fever or fire accidents.
■ Attentions
Caution:The product MUST be connected to the power with leakage protection device.
◆ Earthing: Make sure the
earthing wire is connected to
specified earthing system of the
construction.
If not, please require professional
to install one. Be sure not to
connect the earthing wire to gas
pipe, water pipe or discharge pipe.
◆ Be sure not to repair the
product by yourself.
Incorrect repair may cause an
electric shock or fire.
Please◆ not to let the product
blow directly to stove.
Otherwise, it may cause
poisoning.
◆ Power off the product if you
don’t use for a long time.
Otherwise, accumulative
dirt and likely to cause
◆ Be sure not to put finger or
stick into the net of the fan head
Otherwise, it may cause
personal injury or damage
to the cooler.
Please do not connect the ◆
product to potable water mains.
Water Pressure Range: 0.1-0.45
M Pa
◆ Please keep the product more
than 1 m away from chemical
spray or gas container.
Otherwise, it may cause
explode or fire hazard.
◆ The elderly, weak and
children shall not be blower
directly by the fan. Otherwise,
they may get harm.
◆
Make sure the water tank is
cleaned before using.
For long time no using the ◆
product, please drain off the
tank, so as to avoid the growth of
bacteria
Page 13
@2012.11-V1.1Aviator X2 Page 13 of 15
■ Common Malfunction Analysis and Maintenance
Common Malfunction Analysis
Warning: Wrong operation and maintenance will cause electric shock or a fire.
Please contact the agent or dealer to repair the product by professionals. It can save your time and
expense to check the following before calling service.
Malfunction DescriptionAnalysis
It does not work
It can mist but fail to blow air
It can blow air but fail to spray mist
Guard net is dripping
※ Power failure?
※ The plug is loose from the socket?
※ Circuit protection device is tripping?
※ Leakage protector is off?
※ Check if the voltage is too high or too low?
(measured by professionals)
※Proper use of the timer? (refer to product with
remote control)
※ Twirl the impeller to check if the blade is stuck?
※ Check if each switch works?
※Is male & female plug of fan motor connected
properly?
※ Mist regulating switch is on or off?
※ MIST switch is on or off?
※ The tank is with water and reaches the lowest
water level?
※ Water level sensor is installed correctly or is
turned on?
※ Power cord of the pump and atomization motor
are connected correctly?
※ Misconnect the blue outlet pipe and orange return
pipe?
※ Please use the right amount of detergent to
smear the guard net.
Please contact the agent or dealer if the following happens:
Page 14
@2012.11-V1.1Aviator X2 Page 14 of 15
~There is abnormal noise when the
device is running
~There is smoke or unpleasant smell
~There is water leakage
~Leakage protector is tripping
~ Power cord is abnormally hot and
become abnormally soft.
Stop it and disconnect the
power plug
Maintenance – Water Tank Cleaning
Warning:
¨ To ensure the cleanness of the mist, the product should be cleaned before each use.
¨ Before cleaning the product, stop it and unplug the power, otherwise there
would be risk of electric shock.
¨ Do not use high-pressure water jets to clean this product.
¨ If the power line is damaged, ask service agent or professionals to replace it.
¨ Volatile liquid such as thinner or gasoline will damage the appearance, please use
a soft cloth with neutral detergent to clean this product.
Protection for Control panel
After adjusting the switches, please close the cover of the control box and tighten
the screws as shown, so as to prevent erosion of rainwater or PVC panel aging
caused by sun exposure.
Water Tank Cleaning
² Simple cleaning ( Suitable for the cleaning of each use)
Rotate the two nuts on the control panel; push the panel inwards; clean the inner tank
with long-handled brush; then open the drain valve to drain off the waste water; wash
the tank with clean water; then close the drain valve again; Ensure the water level
sensor is firmly fixed; close the control box.
Page 15
@2012.11-V1.1Aviator X2 Page 15 of 15
²Thoroughly Cleaning ( Suitable for cleaning after 60 hours’ operation)
1. Take the main body apart with the water tank.
1.1 Loosen the 4 butterfly screws on the plate inside the tank
(Refer to the Installation Instruction—Step 3 / Picture 4)
1.2 Take the main body apart with the water tank; take out the submersible pump
and water level sensor (Refer to Installation Instruction—Step 2 / Picture 2)
2. Clean the water tank
Wash the Water Tank inwall with towels or soft brush; open the drain valve
to drain off the waste water; then wash it again with fresh water and the right
amount of cleanser; close the drain valve.
3、Refix the submersible pump and water level sensor; Connect the main body with
the water tank. (Refer to the Installation Instruction—Step 2 / Picture 3)
Note: Please make sure the floater should face the bottom. Otherwise the Level
Sensor will not work.
Drain Valve
Inspection and Maintenance in Daily Use
1、Make sure the machine is connect to the Electricity Leakage protector, and the
earthing wire is connected to specified earthing system of the construction.
2、Before running the product, please check if there any damage or jamming with the
Guard Nets, or if the Impeller rotates smoothly.
3、Pay attention to waterproof and damp-proof.
4、When the Misting Air Cooler is not in the need of using for a long time,
5、4.1 Power should be cut.
6、4.2 The Guard Net, Impeller and body should be clean regularly.
7、4.3 Use specialized protective cover to prevent the damage of rain and dust.
Page 16
FIVE-YEAR LIMITED WARRANTY
The appliance has been manufactured under the highest standards of quality and workmanship. We
warrant to the original consumer purchaser that all aspects of this product will be free of defects in
material and workmanship for five (5) year from the date of purchase. A replacement for any defective
part will be supplied free of charge for installation by the consumer. Defects or damage caused by the
use of other than genuine parts are not covered by this warranty. This warranty shall be effective from
the date of purchase as shown in the purchaser’s receipt.
This warranty is valid for the original consumer purchaser only and excludes industrial, commercial or
business use of the product, product damage due to shipment or failure which results from alteration,
product abuse, or product misuse, whether performed by a contractor, service company, or consumer.
We will not be responsible for labor charges and/or damage incurred in installation, repair or replacement, nor for incidental or consequential damage.
When You Receive Your Product:
If Your Product is..
• Damaged
• Requires Technical Support
• Requires Parts
• Or If You Have A Sales Question Or You Would Like To Offer Product Feedback
Please contact the manufacturer:
LAVA AIRE ITALIA
888.779.5282 or
CS@LAVAAIRE.COM
DO NOT RETURN PRODUCT TO RETAILER!
LAVA AIRE ITALIA
Toll free No.: 1.888.779.LAVA 1.888.779.5282
Addr.: 5999 Malburg Way, Vernon, CA, 90058
16
Page 17
Dear Valued Lava Aire Italia Customer,
Thank you for purchasing a Lava Aire Italia product!
Congratulations and welcome to the Lava Aire Italia family.
Our mission is to design and construct beautifully engineered,
high quality products for all to use and enjoy for years to come.
Lava Aire was originally founded by lead designer and chief engineer, Mr. JR Zioni in Modena, Italy in 1997. Today Lava Aire Italia
has expanded to the USA and oers well over 100 innovative
heating, cooling and home appliance products worldwide. We
encourage you to visit our website; www.LavaAire.com to get a
detailed view of our most up to date list of cutting-edge products.
We appreciate your business.
Sincerely,
J. Zioni.
MANUFACTURED BY:
LAVA AIRE ITALIA
T. 888.779.LAVA T. 888.779.5282
VERNON, CA 90058
WWW.LAVAAIRE.COM