Laurel Electronics Laureate Quadrature Encoder Position User Manual

LAUREL
Features
Accepts low-level differential or single-ended 5V logic level outputs from quadrature encoders
Quadrature count x1, x2 or x4
Combined encoder pulse rate to 250 kHz
Programmable display update rate up to 25/s
Zero channel input 6-digit red or green LED display
Universal AC power Input, 85-264 Vac
Isolated 5, 10 or 24 Vdc excitation output
NEMA 4X, 1/8 DIN case
Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter
Optional relay outputs: dual or quad relays, contact or solid state
Optional isolated analog output: 4-20 mA, 0-20 mA, 0-10V, -10 to +10V
Optional low voltage power: 10-48 Vdc or 12-32 Vac
Description
Position, Length or Angle Measurement
The Laureate™ quadrature meter with the Standard counter main board accepts the A & B quadrature signals from linear encoders and shaft encoders to provide a highly accurate, scaled display of position, length, or angle in engineering units, such as ft, cm or degrees. The A & B quadrature signals are 90° out of phase, and their phase relationship determines whether up counts (+) or down counts (-) are counted. The meter totalizes the counts and then scales the total in software for display and control. A zero index signal, or Z signal, may be added as a third input to the A & B signals.
Scaled Rate Measurement
Use of the Extended counter main board can convert the quadrature meter from scaled position to scaled rate. For example, it can display the speed of a moving slab in ft/sec. Simultaneous display of position and rate will require two meters. The display and control output update rate for position or rate is normally set to a maximum of 25/s, as determined by a user­programmable gate time.
Quadrature Meter Capabilities
One, two or four transitions may be counted at a maximum combined rate of 250 kHz and be mathematically scaled for display in engineering units from -999,999 to +999,999. The quadrature board has input circuitry which may be jumpered
Laureate™ Quadrature Encoder
Position & Rate Meter
for either single-ended input signals or for balanced line driver signals. Anti-jitter circuitry eliminates errors produced by vibration of the encoder.
A zero index pulse, if available, is interpreted by the meter as indicating a zero reference for an integral number of revolutions of a rotary shaft encoder or the home position of a linear encoder. It is used by the meter for initializing and to correct for any cumulative pulse count errors. Special circuitry corrects for width of the zero index pulse.
In the event of a power failure, the latest total may be stored in non-volatile memory and can be used as the starting point for counting when power resumes. Power fail save or zero index capabilities are alternate meter setup choices.
Designed for system use. Optional plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built­in isolated 5, 10, or 24 Vdc excitation supply can power trans­ducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
LAUREL
ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 1
Specifications
Display
Readout Display Range Zero Adjust Span Adjust Indicators
Inputs
Type Transitions Monitored Max Pulse Rate Position Error Differential high threshold Differential low threshold Differential common mode Single-ended high voltage Single-ended low voltage Input Resistance, typ.
Quadrature Position Mode
Zero Adjust Span Adjust
Quadrature Rate Mode
Conversion Technique Conversion Time Gate time Time Before Zero Output Output & Display Update Time Base Accuracy
6 LED digits, 7-segment, 14.2 mm (.56"), red or green LED
-999999 to +999999, XXXXEX notation beyond 999999
-999999 to +999999 0 to 999999 Four LED lamps
Differential or single-ended quadrature x1, x2 or x4 250 kHz at x1, 125 kHz at x2, 62.5 kHz at x4 No error contributed by meter +200 mV
-200 mV ± 7V
2.5V to 10V
-1V to +1V 17 kOhm
-999999 to +999999 0 to 999999
Inverse period Gate time + 30 ms + 0-2 signal periods Selectable 10 ms to 199.99 s Selectable 10 ms to 199.99 s Same as conversion time Calibrated to ±2 ppm
Power
Voltage, standard Voltage, optional Frequency Power Isolation
Excitation Output (standard)
5 Vdc 10 Vdc 24 Vdc Output Isolation
Analog Output (optional)
Output Levels
Current compliance Voltage compliance Scaling Resolution Isolation
Relay Outputs (optional)
Relay Types
Current Ratings
Output common Isolation
85-264 Vac or 90-300 Vdc (DC operation not UL approved) 12-32 Vac or 10-48 Vdc DC or 47-63 Hz 250V rms working, 2.3 kV rms per 1 min test
5 Vdc ± 5%, 100 mA 10 Vdc ± 5%, 120 mA 24 Vdc ± 5%, 50 mA 50 Vdc to meter ground
4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option) 4-20 mA, 0-20 mA, 0-10V (dual-output option) 2 mA at 10V ( > 5 kΩ load) 12V at 20 mA ( < 600Ω load) Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale) 250V rms working, 2.3 kV rms per 1 min test (dual analog outputs share the same ground)
2 Form C contact relays or 4 Form A contact relays (NO) 2 or 4 Form A, AC/DC solid state relays (NO) 8A at 250 Vac or 24 Vdc for contact relays 120 mA at 140 Vac or 180 Vdc for solid state relays Isolated commons for dual relays or each pair of quad relays 250V rms working, 2.3 kV rms per 1 min test
LAUREL
ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 2
Serial Data I/O (optional)
Mechanical
Board Selections
Protocols Data Rates Digital Addresses Isolation
Environmental
Operating Temp. Storage Temp. Relative Humidity Protection
Ethernet, Ethernet-to-RS485 converter, USB, USB-to-RS485 converter, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232. Modbus RTU, Modbus ASCII, Laurel ASCII protocol 300 to 19200 baud 247 (Modbus), 31 (Laurel ASCII), 250V rms working, 2.3 kV rms per 1 min test
0°C to 60°C
-40°C to 85°C 95% at 40°C, non-condensing NEMA-4X (IP-65) when panel mounted
LAUREL
ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 3
Application Examples
Using Quadrature for Cutting to Length
Using Quadrature for X-Y Positioning
Controlling the repetitive cutting of material to length is an excellent application of the Laureate quadrature meter.
The quadrature encoder shares the shaft of a sensing wheel, whose rotation corresponds to lineal displacement of material. The meter compares the displacement reading against setpoint information, and then uses its dual relays to first slow down and then cut the material.
Accurate X-Y position or rate can be obtained from two shaft encoders, which convert linear position to quadrature signals as a shaft turns. In addition to serving as a display, each Laureate can use its optional dual relay setpoint capability for closed loop control. It can also transmit data via RS-232, RS-485, or a 4-20 mA analog signal.
Using Quadrature to Monitor a Drilling Operation
Quadrature can be used to track position and vertical drilling speed of the bit in an oil drilling operation. A shaft encoder is rotated by a cable that moves with the drilling shaft.
In this application, the same encoder signal is applied to a Laureate quadrature meter for position, and to a second quadrature meter for rate. Both meters can be scaled to read out in appropriate engineering units, such as feet and inches per minute, and can be alarmed. A Laureate 6-digit remote display could be added to read out peak rate.
LAUREL
ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 4
Ordering Guide
Create a model a model number in this format: L50000QD, IPC
Main Board L5 Standard Main Board, Green LEDs (for position)
L6 Standard Main Board, Red LEDs (for position) L7 Extended Main Board, Green LEDs (for position or rate) L8 Extended Main Board, Red LEDs (for position or rate)
Power 0 Isolated 85-264 Vac
1 Isolated 12-32 Vac or 10-48 Vdc
Relay Output
(isolated)
Analog Output
(isolated)
Digital Interface
(isolated)
Input Type QD Quadrature Signal Conditioner
Add-on Options BL Blank lens without button pads
0 None 1 Two 8A Contact Relays 2 Two 120 mA Solid State Relays 3 Four 8A Contact Relays 4 Four 120 mA Solid State Relays
0 None 1 Single isolated 4-20 mA, 0-20 mA, 0-10 V, -10 to +10V 2 Dual isolated 4-20 mA, 0-20 mA, 0-10V
0 None 1 RS-232 2 RS485 (dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 converter 7 Ethernet 8 Ethernet-to-RS485 converter
CBL01 RJ11-to-DB9 cable CBL02 USB-to-DB9 adapter CBL05 USB Cable, A to B IPC Clear front panel cover sealed to NEMA 4X / IP65 BOX1 NEMA-4X wall-mount enclosure BOX2 BOX1 plus IPC