Laurel Electronics IPC Specifications

LAUREL
Protects 1/8 DIN instruments to NEMA-4 / IP67 from the front
Features
Meets NEMA 12 (IP52) when hinged door is snapped in place
Meets NEMA 4X (IP67) when door is clamped by a locking key
Fits all 1/8 DIN Laureates and most other 1/8 DIN instruments
Utilizes existing 1/8 DIN cutout -- no extra panel holes required
Made of high-impact polycarbonate -- no metal parts to corrode
Hinged door for easy access to instrument
Low cost
Description
Model IPC Splashproof Cover is a rugged, impact resistant,
clear lens that fits over a 1/8 DIN instrument to make it dust and water proof from the front of the panel. Sealing meets NEMA 12 (IP52) standards for water splash and dust protection when the hinged door is simply snapped in place. Sealing meets NEMA 4 (IP67) standards for hose-directed water when the hinged door is further clamped down with a provided plastic locking key.
Model IPC Splashproof Cover
of clear silicone grease, or other approved sealant, to the mating groove to prevent any ingress of liquid and enable the cover to withstand steam cleaning.
Model IPC splashproof cover
Model IPC fits all Laurel 1/8 DIN instruments as well as 1/8 DIN instruments by other manufacturers, provided that instrument dimensions in front of the panel do not exceed 48 x 96 x 15 mm (1.89" x 3.78" x 0.59"). Model IPC can be purchased as an add­on option for new instruments, or be fitted to existing installations.
The IPC assembly utilizes a clear base and clear door with a cam hinge. The hinge is captive when the base and meter are installed, and allows the door to be opened for easy access to the meter for programming or setpoint adjustment. The base can be sealed against the instrument panel by an O-ring or a self­adhesive neoprene gasket, both provided.
A capillary seal is formed between the door and the base by a tapered recess in the door and a tapered ridge in the base. Capillary action causes a small amount of water to be drawn in between the two surfaces, thereby producing a water-tight film around the sealing area. For applications where fluid residues are unacceptable, such as food processing, apply a light coating
Box2 wall-mount enclosure with IPC splash-proof cover.
Suitable for 1/8 DIN instruments up to 160 mm deep.
The door is latched against the base by a locking tab when the door is snapped shut. Positive clamping of the door and protection against opening of the locking tab by hose-directed water are provided by a locking key, which remains in place to provide a much higher clamping force than the tab alone.
A removable key lock is required to
open the IPC splash-proof cover.
Model IPC is easy to install. It utilizes the existing 1/8 DIN panel cutout (45 x 92 mm). No new panel holes are required.
LAUREL
ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 1
Specifications
Mechanical
Instrument panel cutout External dimensions, base External dimensions, door Protrusion in front of panel Sealing, door to cover base Sealing, base to instrument panel Provision for assembly integrity
Materials
Base, door & locking key Provision for corrosion resistance Gaskets
Sealing Performance
Hinged door snapped in place Hinged door locked by locking key
Ordering Guide
IPC Add-On Splashproof Front Cover for 1/8 DIN Meters. Sealed to IP67 / NEMA-4.
1/8 DIN, 45 x 92 mm (1.77" x 3.62")
115.3 x 55.4 x 6.1 mm (4.54" x 2.18" x 0.25")
103.4 x 54.4 x 18.0 mm (4.07" x 2.14" x 0.71")
23.8 mm (0.94") Capillary seal O-ring gasket or adhesive gasket (both provided) Door is captive when IPC assembly is panel mounted
Transparent polycarbonate No metal parts O-ring gasket or self-adhesive neoprene gasket.
NEMA 12 (IP52) protection, dust and splashed water. NEMA 4 (IP67) protection against hose-directed water.
LAUREL
ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 2