LAUER LCA 042 User Manual

Page 1
TEXT DISPLAY
LCA 042
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/96600 • FAX 07022/9660103
The attractively designed LCA 042, incor­porates many interesting features. One of the successful LCA series of text dis­plays.
■ avoid malfunctions,
■ indicate how faults can be eliminated,
■ provide operator guidance,
■ give important set-up information,
■ show what the machine is currently doing,
■ support maintenance and servicing,
■ issue instructions for carrying out adjustments,
■ combine variable values with fixed texts
LCA text displays save time and money. Neither designers nor production personnel can do without text displays. Therefore they are part of the standard equipment of every machine.
With the LCA 042 text display you can invoke up to 200 messages. It can be driven by any programmable con-troller or by individual contacts or proximity switches.
All text displays are unobtrusive and have an unmi­stakable appearance. LCA text displays are functional, well-designed units that can be integrated harmoni­ously into your machines.
MANUAL FOR THE LCA 042
042 PRINT 01/11.89
Page 2
TEXT DISPLAY
LCA 042
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/96600 • FAX 07022/9660103
CPU INPUT INPUT OUTPUT OUTPUT
SIMATIC S5-115U
+ 24 V
UNIVERSAL-ADAPTER LCA 024
SPS/PLC
SPS/PLC
▲
▼ ▼
▼ ▼
▼
▼
ENTER
SHIFT
SHIFT
KEYBOARD
EPROM PROGRAMMER
-TEXT DISPLAY LCA 042 WITH ACCESSORIES
▲
▲
▲
EPROM
2764/2764 A
LCA 014
EPROM-PROGRAMMER
EPROM
SCHREIBEN/WRITE
EPROM
LESEN/READ
POWER ON
▲
▲
TESTKONSOLE LCA 015
LETZT ERST RES DIREKT MELD MELD LÖSCH
BIN TAKT VAR MELD TAKT QUIT 256 GEHT LÖSCH
BIN BIN BIN BIN BIN BIN BIN BIN 128 64 32 16 8 4 2 1
SPS
LCA 020
LCA 015
LCA 010
LCA 014
LCA 293
PC
▼▼▼▼▼
▲
▼
EPROM
2764/2764 A
EPROM
2764/2764 A
LCA 048
LCA 030 LCA 031
LCA 030 LCA 031
LCA 038
LCA 024
LCA 010 POCKET KEYBOARD LCA 014 EPROM-PROGRAMMER LCA 048 EPROM 2764 LCA 015 TEST CONSOLE LCA 020 INDUSTRIAL ADAPTER LCA 024 UNIVERSAL ADAPTER LCA 025 ADAPTER EXPANDER LCA 293 P-SOFTWARE FOR LCA 042 LCA 030 FLAT CABLE 200 cm LCA 031 FLAT CABLE 30 cm LCA 038.2 ROUND CABLE 200 cm LCA 038.4 ROUND CABLE 400 cm LCA 038.6 ROUND CABLE 600 cm LCA 038.8 ROUND CABLE 800 cm
Text display LCA 042 can ...
■ display 200 messages with 40 characters each - the message texts can be transfered either into the RAM by means of a keyboard or into the EPROM using the LCA 014 (or a PC)
■ display texts directly - the text of a message is displayed for as long as the coded message number is present on the inputs of the LCA 042
■ store 19 messages and display them cyc- lically - the number of messages invoked is
dis-played in the last two columns of a text line
■ display the first message and store the others - the other messages are requested
and displayed via the clock input
■ display messages on several lines - the first line contains the main information, the other two lines additional information
■ combine external variables and fixed texts in one line - all ASCII and BCD characters
are permissible as variables
■ be driven by any programmable controller using BCD/BIN-code or by universal adapter LCA 024 (using contacts, proximity switches etc.)
ACCESSORIES
PROG. CONT. CONNECTION
INTERFACING
PROGRAMMING
ACCESSORIES
Page 3
TEXT DISPLAY
LCA 042
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/96600 • FAX 07022/9660103
1 Connections to the LCA 042
1.0 Connections to the LCA 042
1.1 Connection of the Prog. Cont.
1.1.1 Prog. Cont. connection via industrial adapter LCA
020
1.1.2 Prog. Cont. connection via round cable LCA 038
1.2 Connection of the pocket keyboard LCA 010
1.3 Connection of the EPROM programmer LCA 014
2 Specifications of the LCA 042
2.1 Power supply
2.2 Installation instructions
2.3 Specifications
3 Programming the LCA 042
3.1 Entry of message texts with keyboard LCA 010
3.2 Copying message texts into EPROM
3.3 ASCII character chard
4 Operation of the LCA 042
4.1 Invocation of messages by the Prog. Cont.
4.2 The message number
4.3 The message variants
4.3.1 Direct message
4.3.2 Multi-line message
4.3.3 First message
4.3.4 Cyclic display
4.4 External variables
5 Text display without Prog. Cont.
5.1 Universal Adapter LCA 024/025
Operating instructions, manuals and software are pro­tected by copyright. All rights are reserved. Copying, reproduction, translation or transfer, in whole or in part, is forbidden. The only exception a back-up copy of the software for the customer's own use.
TABLE OF CONTENTS
Page 4
TEXT DISPLAY
LCA 042
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/96600 • FAX 07022/9660103
1 TEXT DISPLAY LCA 044 2 TEXT DISPLAY LCA 045 3 TEXT DISPLAY LCA 143 4 TEXT DISPLAY LCA 145 5 TEXT DISPLAY LCA 245 6 TEXT DISPLAY LCA 265 7 DIAGNOSTIC SYSTEM LCA 285 8 INDUSTRIAL PRINTER LCA 710
FURTHER PRODUCTS FROM
OUR RANGE
Page 5
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
1
Prog. Cont. interface
Pocket keyboard
LCA 010
EPROM programmer
LCA 014
CPU INPUT INPUT OUTPUT OUTPUT
SIMATIC S5-115U
EBERLE PLS 508
EPROM
2764/2764 A
LCA 014
EPROM-PROGRAMMER
EPROM
SCHREIBEN/WRITE
EPROM
LESEN/READ
POWER ON
ENTER
SHIFT
SHIFT
-CONNECTIONS TO THE LCA 042
1.0 CONNECTIONS TO THE LCA 042
There are three plug-type connectors on the rear of the LCA 042:
- Connector for programmable controller
25-pin DIN plug
- Connector for pocket keyboard LCA 010
20-pin plug
- Connector for EPROM programmer LCA 014
10-pin plug
We recommend out text display LCA 042 for use with pro­grammable controllers made by the following manufac­turers:
AEG Kunke April Mitsubishi ABB Texas Instruments B & R Selectron Eberle Schiele Festo Siemens IFM Omron Inter Control Philips Klaschka Klöckner-Moeller
and many others
Page 6
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
15
-CONNECTION OF THE PROGRAMMABLE CONTROLLER
CPU INPUT INPUT OUTPUT OUTPUT
SIMATIC S5-115U
EBERLE PLS 508
1) For increased protection against interference you should wire the connection “0V Signal”.
MESSAGE or TEXTNUMBER FUNCTION POWER 5 17 4 16 3 15 2 14 1 8 20 7 22 10 11 24 25
BCD 001/BIN 001
BCD 002/BIN 002
BCD 004/BIN 004
BCD 008/BIN 008
BCD 010/BIN 016
0V, GND
0V Signal
1)
+24 V=
BCD 020/BIN 032
BCD 040/BIN 064
CLOCK
TEXT/VARIABLE
DIRECT/SEQUENTIAL
BCD 080/BIN 128
BCD 100
1.1 CONNECTION OF THE PROG. CONT.
The parallel interface is the most important connection be-tween the machine (controller) and the text display LCA 042. All significant functions of the LCA 042 are performed via this interface. These functions are:
- invoking the message texts (max. 200)
- invoking the message variants (functions)
- entering external variables
All inputs are high-active (Ri = 2.6kΩ)
BIN 0... 199 BCD 0... 199 = coded message number
CLOCK = 1. invoke additional messages
2.display external variables on text display
3. invoke further messages (at first message)
TEXT/VARIABLE = switch between message text and
external variable
DIRECT/SEQUENTIAL = switch between direct message and first
message (sequential display)
The connection to the programmable controller is made via industrial adapter LCA 020 or round cable LCA 038.
Text display LCA 042 distinguishes between PROGRAM­MING and OPERATION. During programming operation of the LCA 042 is not possible.
Before the LCA 042 is put into operation the following
preparations must be made:
1. initialize
2. store message texts
3. determine positions of variables by means of place holders
Page 7
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
16
-PROG. CONT. CONNECTION VIA INDUSTRIAL ADAPTER
1.1.1 INDUSTRIAL ADAPTER LCA 020
When using control cabinet techniques, connections are normally made by means of screw terminals. To enable the use of this type of installation with the text display LCA 042 we supply the industrial adapter LCA 020.
The electrical connections between the programmable controller and the LCA 020 are made using the well-tried wiring method via terminals and the connections between the LCA 020 and the text display LCA 042 are by means of ready-made flat cables (LCA 030 or LCA 031).
Flat cable LCA 030, LCA 031
INDUSTRIAL ADAPTER LCA020
Programmable Controller
Programmable Controller outputs
Programmable Controller connection
Page 8
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
17
-PROG. CONT. CONNECTION VIA ROUND CABLE
Programmable Controller
Programmable Controller outputs
Round cabel LCA 038.2 ... 038.8
Programmable Controller connection
1.1.2 ROUND CABLE LCA 038
The simplest and most economical way of connecting the text display to the programmable controller is by means of ready-made round cables.
We supply round cable LCA 038 in 4 standard lengths (from 200 to 800 cm) and a suitable plug for the text display.
Further details can be found in the description of the round cable.
Page 9
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
2
-CONNECTION OF THE LCA 010
ENTER
SHIFT
SHIFT
Pocket keyboard
LCA 010
1.2 CONNECTION OF THE LCA 010
The simplest way of entering and correcting message texts is by means of the pocket keyboard LCA 010. The LCA 010 is connected to the LCA 042 via a cable. As long as the two units are connected together, no messages can be invoked.
The pocket keyboard has 27 brown keys for alphanu­meric characters and 8 red function keys. Following is a description of the function keys:
Backwards in program
Forwards in program or invoke program
Cursor forwards; together with SHIFT key, backwards
Program selection
Shift key
Flash/delete
See also Section 3.1 of this manual.
ENTER
SHIFT
Page 10
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
3
EPROM
2764/2764 A
LCA 014
EPROM-PROGRAMMER
EPROM
SCHREIBEN/WRITE
EPROM
LESEN/READ
POWER ON
-CONNECTION OF THE LCA 014
EPROM programmer
LCA 014
1.3 CONNECTION OF THE LCA 014
Using EPROM programmer LCA 014 the message text stored in the RAM can be copied into a suitable EPROM. The LCA 014 does not require an additional voltage supply, it is simply connected to text display LCA 042 with a cable. As long as the two units are connected together, no message can be invoked.
The EPROM is programmed, written to, compared with or read out in dialog with the LCA 042. The Pocket keyboard LCA 010 is therefore required.
See also Section 3.2 of this manual.
Page 11
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
18
DIAGNOSE-SYSTEM LCA 285.0
EXTERNE VARIABLE
2.1 VOLTAGE SUPPLY
To ensure correct operation of the text display LCA 042 observe the following instructions as regards the voltage supply:
Use the LCA 042 only with operating voltages in the range indicated.
Undervoltage transients of down to 9.5V for <= 1ms are permissible.
An operating voltage UB of 35V= is permissible for <= 100ms (repetition frequency approx. 1Hz).
The LCA units may be driven only with “protective low voltage” in accordance with German Electrical Stan­dard VDE 100. The driver transformer must conform to German Electrical Standard VDE 0551. According to this standard one side of the operating voltage may be grounded: we recommend that this be done when working with our units.
If one side of the operating voltage is not grounded, you will require your own driver transformer to operate the LCA 042.
The LCA 042 is grounded via the housing. Use a short ground connection wire with a large cross-sectional area (>= 2.5mm2)
If the operating voltage is also used to drive inductances, protective circuitry must be incorporated for them (recovery diode, etc.).
Operating voltages greater than those indicated (+33V) can destroy the unit. In this case our guaran­tee does not apply.
SPS
LCA
~ 380 VAC
3/N/PE 380 VAC
= 24 VDC
+ 24VDC
0V DC
L 1 L 2 L 3 N PE
Operating voltage UB: 24V= (<=5% residual ripple) acc. to DIN 19240 U
Bmax
:33V=
U
Bmin
:19V=
Current consumption : ≤ 350 mA (+24V=)
Page 12
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
19
SOURCE OF INTERFERING RADIATION
SOURCE OF INTERFERING RADIATION
SOURCE OF INTERFERING RADIATION
approx. 250 mm
approx. 250 mm
approx. 250 mm
2.2 INSTALLATION INSTRUCTIONS
In order to reduce the effects of interfering signals radiated by electric and magnetic fields, the minimum distance from high-voltage or high-frequency carrying cables and consumers should be >= 250mm. The input wires to the LCA 042 should not be routed together with high-voltage or high-frequency carrying cables.
Page 13
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
20
max. thickness of material 5 mm
247 +0.5 mm
67 +0.5 mm
FRONT PANEL CUTOUT
254 mm
58 mm
74 mm
72 mm
LCA viewed from front
LCA viewed from above
LCA viewed from side
LCA viewed from rear
rubber seal
LCA 010 connection Prog. Cont. connection LCA 014 connection
message texts
EPROM
2.3 SPECIFICATIONS
A high degree of immunity1 to interference and of electrical protection (IP 65) ensure correct functioning, even in rough industrial environments.
TECHNICAL DATA
Operating Voltage 19 ... 33 V
Power consumption 8 W Signal voltage 19 ... 33 V= Signal current (UB = 24V) 9 mA
Display flourescent Characters per line 40 Character depiction 5 x 7 matrix Character height 7 mm Character set ASCII
Message invocation BCD / BINÄR
1 AKTIV / Ø AKTIV Messages max 200 Messages text memory RAM/EPROM External variables max. 40 characters
Operating temperature 0 ... 50 °C Storage temperature -25 ... 70 °C
Connections plug-type Electrical protection IP 65
Weight approx. 1000 g Dimensions see dim. drawing
Installation is simple, all that is needed is a cutout in the front panel. The rugged housing consists of two parts which are separated for installation.
1) In order to ensure the maximum degree of immunity to interference, the keyboard LCA 010 and the EPROM programmer should not remain connected during operation of the text display.
Page 14
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
4
-ENTRY OF MESSAGE TEXTS WITH KEYBOARD LCA 010
ENTER
SHIFT
SHIFT
SYSTEME LAUER LCA 042 VERSION 00
‘
‘
Pocket keyboard
LCA 010
WHICH PROGRAM?
01: DELETE TEXT (ALL)
Invoke
program
Invoke
program
Invoke
program
Invoke
program
Invoke
program
Invoke
program
Invoke
program
02: FREE SETS?
03: ENTER AND EDIT TEXT
04: CHECK TEXT
06: INITIALIZE
07: TEST TEXT INVOCATION
09: EPROM PROGRAMMER
Using the pocket keyboard LCA 010 you can invoke the various programs of the text display LCA 042 in an easily
understandable dialog pro­cess. Before entering mes­sage texts you should first
delete all texts (program 1) and then initialize the LCA 042 (program 6). This pro­cedure is not necessary if you only want to correct or expand message texts.
The individual programs are described in detail in the programming instruc­tions, which are supplied with every text display.
3.1 ENTRY OF MESSAGE TEXTS WITH KEY­BOARD LCA 010
Page 15
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
5
EPROM
2764/2764 A
LCA 014
EPROM-PROGRAMMER
EPROM
SCHREIBEN/WRITE
EPROM
LESEN/READ
POWER ON
ENTER
SHIFT
SHIFT
-COPYING MESSAGE TEXTS INTO EPROM
3.2 COPYING MESSAGE TEXTS INTO EPROM
The texts entered using pocket keyboard LCA 010 are stored in a battery-backed-up RAM. They can be deleted, edited or expanded as often as you wish.
The contents of the RAM can be rapidly copied into an
EPROM using EPROM programmer LCA 014:
1. Program initialization and message texts using the
pocket keyboard.
2. Plug an empty EPROM 2764 (e.g. LCA 048) into the
LCA 014 socket.
3. Using the LCA010 invoke program 8 in text display
LCA 014.
4. Plug programmed EPROM into socket of LCA 042.
As long as there is an EPROM in the LCA 042, its contents are valid and the LCA 010 is not accessed. If the EPROM is removed, the contents of the RAM become valid. With program 8 (READ EPROM) the contents of an EPROM can also be copied into the RAM.
EPROM programmer
LCA 014
Pocket keyboard
LCA 010
08: EPROM PROGRAMMER
WRITE TO EPROM (Y/N)
COMPARE EPROM (Y/N)
READ EPROM (Y/N)
Y
Invoke program
Y
Invoke program
Y
Invoke program
Page 16
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
21
20 30 40 50 60 70
SPACE 0 @ P ° p
! 1 A Q aq " 2 B R br
# 3 C S cs $ 4 D T dt
% 5 E U eu & 6 F V fv
« 7 G W gw
( 8 H X hx ) 9 I Y iy * : J Z jz + ; K €kŠ , < L …l š
- = M †mŸ . > N ▲ n§ / ? O ▼ o ■
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9
▲
­+ .
SPACE
0 1 2 3 4 5 6 7 8 9 A B C D E F
00
CR
ASCII BCD
3.3 ASCII CHARACTER CHART
The chart opposite shows the set of characters for mes­sage texts and variables that can be depicted on text display LCA 042. The complete character set is available only via the EPROM. When using pocket keyboard LCA 010, only the characters shown in outline in the chart are
available.
The variables can be ASCII-coded or BCD-coded. The
BCD chart for variables is thus shown separately.
Other country-specific character sets (German, Italian,
Spanish, Scandinavian) are available on request.
Page 17
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
6
-INVOCATION OF MESSAGES BY THE PROG. CONT.
MESSAGE- or TEXT NUMBER FUNCTION POWER 18 5 17 4 16 3 15 2 14 1 8 20 7 22 10 11 24 25
OPERATING
VOLTAGE
MESSAGE
ØØØ
MESSAGE
ØØ1
TIME
1 2 3 4
>= 75 msec
+ 24V 0 V
ON OFF
ON OFF
TIME 1: Operating voltage is switched on. The LCA 042 is ready to operate after approx. 0.7s. TIME 2: The message text of message ØØØ is displayed. TIME 3: The message number of message ØØ1 is placed on the inputs of the LCA 042. TIME 4: The message number must remain on the inputs for a minimum period of >= 75ms,
after this the message can change.
4.1 INVOCATION OF MESSAGES BY THE BY PROG. CONT.
In order to invoke a message or a message text, the coded message number must simply be placed on the message inputs. Every time the message number is changed, a new message is displayed or stored, depending on the messa­ge variants.
The only condition for correct invocation of a message is that the message number must be present on the message inputs for a minimum period.
Page 18
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
7
BIN BIN BIN BIN BIN BIN BIN BIN Mess. 1286432168421 number
000 00000 000 000 00001 001 000 00010 002 000 00011 003 000 00100 004 000 00101 005 000 00110 006 000 00111 007 to 110 00110 198 110 00111 199
BCD BCD BCD BCD BCD BCD BCD BCD BCD Mess. 100804020108421 number
000 000000000 000 000001001 000 000010002 000 000011003 000 000100004 000 000101005 000 000110006 000 000111007 to 110 011000198 110 011001199
-THE MESSAGE NUMBER
MESSAGE 000
MESSAGE 001
MESSAGE 002
MESSAGE 003
MESSAGE 199
MESSAGE 000
MESSAGE 001
MESSAGE 002
MESSAGE 003
MESSAGE 199
4.2 THE MESSAGE NUMBER
The message number determines which message text is invoked. The message number is coded to allow the maximum quantity of messages to be invoked with the minimum of message inputs.
Text display LCA 042 offers the of two coding options:
- BIN-coded message numbers, up to 199 pages
- BCD-coded message numbers, up to 199 pages
200 messages are available with the LCA 042. They have the message numbers 000 ... 199. You can join up to 3 message text lines into one message text. The first line contains the main information, the other two lines the additional information.
Page 19
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
8
1) Due to standardization of the input signals the designations have been altered. The old designations are given in brackets. You may still find these designations on some LCA units.
-THE MESSAGE VARIANTS
Optionally the function inputs can be:
- hard-wired (open input corresponds to “log 0”)
- driven by keys and switches
- driven by programmable controller outputs
MESSAGE- or TEXTNUMBER FUNCTION POWER 18 5 17 4 16 3 15 2 14 1 8 20 7 22 10 11 24 25
CLOCK
TEXT/VARIABLE
DIRECT/SEQUENTIAL
4.3 THE MESSAGE VARIANTS
You determine the message variant or operating mode of text display LCA 042 using the 3 function inputs
- DIRECT/SEQUENTIAL
- TEXT/VARIABLE (TEXT/DATA)
1)
- CLOCK (DATA-CLOCK)
1)
DIRECT MESSAGE
A message is invoked and displayed for as long as the coded message number is present on the LCA 042.
MULTI-LINE MESSAGE
If one line per message is not enough, then to each main message two additional messages, two additional lines, can be invoked with CLOCK.
FIRST MESSAGE
The LCA 042 displays the first message first, all other messages (max. 19) are registered in the order of their appearance in the message memory. The last two columns of the messa-ge line give information on the number of messages registe-red. These messages are invoked one after the other with CLOCK.
CYCLIC MESSAGE
All messages (max. 19) are registered in the message me­mory and displayed in rotation. The last two columns of the message line give information on the number of messages registered. The CLOCK must be at log 1 (+24V).
EXTERNAL VARIABLES
The LCA 042 can combine fixed texts with external varia­bles. The number of variables and their position on the message line can be determined using place holders.
Page 20
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
9
-THE DIRECT MESSAGE
DIRECT/SEQUENTIAL ( 7 ) = 0
1)
TEXT/VARIABLE ( 20 ) = 0 CLOCK ( 8 ) = 0
Programmable Controller
Prog. Cont. outputs
MESSAGE- or TEXTNUMBER FUNCTION POWER 18 5 17 4 16 3 15 2 14 1 8 20 7 10 25
BCD 001/BIN 001
BCD 002/BIN 002
BCD 004/BIN 004
BCD 008/BIN 008
BCD 010/BIN 016
0V, GND
+24 V=
BCD 020/BIN 032
BCD 040/BIN 064
BCD 080/BIN 128
BCD 100
BCD 200
1) log 0 = OV, open input log 1 = +24 V
= CLOCK
4.3.1 DIRECT MESSAGE
The simplest operating mode is the “direct message”. A message is displayed for as long as the coded message number is present on the LCA 042. The display changes analogously to the changing of the message number.
Message number 000 indicates that no message has
been invoked.
Page 21
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
10
CLOCK (DATA-CLOCK) can be triggered by a key or by the programmable controller.
MESSAGE
0 1 2 3 63 64 65
Main line 000 003 006 009 189 192 195 1st add. line 001 004 007 010 to 190 193 196
2nd add. line 002 005 008 011 191 194 197
-THE MULTI-LINE MESSAGE
Programmable Controller
Prog. Cont. outputs
MESSAGE- or TEXTNUMBER FUNCTION POWER 18 5 17 4 16 3 15 2 14 1 8 20 7 10 25
BCD 001/BIN 001
BCD 002/BIN 002
BCD 004/BIN 004
BCD 008/BIN 008
BCD 010/BIN 016
0V, GND
+24 V=
BCD 020/BIN 032
BCD 040/BIN 064
CLOCK
BCD 080/BIN 128
BCD 100/BIN 256
BCD 200
1st CLOCK = additional line 1 2nd CLOCK = additional line 2 3rd CLOCK = main line
1) log 0 = OV, open input log 1 = +24 V
= CLOCK
2) Example
4.3.2 MULTI-LINE MESSAGE
Multi-line messages consist of a main message and two addi-tional messages. For certain messages a multi-line display is advantageous, for example:
- to display message texts in three different languages
- to give information on the fault in the main message and information on fault elimination in the additional messa-ge
- to indicate an operation in the main message and adjust-ment values in the additional message.
The main message is always invoked using message num­ber (003)2). The two message numbers (004 + 005)2) which follow this main message are reserved for the two addi­tional mes-sages. The additional messages are invoked simply with CLOCK.
In this message variant each message occupies three lines. The LCA 042 can thus display a maximum of 65 x 3 messages. In principle the main line can be positioned using any messa-ge number pattern. It is however advan­tageous to use the allocation: 000, 003, 006 ...
If a new message is invoked while the LCA 042 is displaying an additional message, the display of the addi­tional message is immediately stopped and the new main message dis-played.
DIRECT/SEQUENTIAL ( 7 ) = 0
1)
TEXT/VARIABLE ( 20 ) = 0 CLOCK ( 8 ) =
Page 22
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
11
-THE FIRST MESSAGE
MESSAGE- or TEXTNUMBER FUNCTION POWER 18 5 17 4 16 3 15 2 14 1 7 20 8 10 25
BCD 001/BIN 001
DIRECT/SEQUENTIAL
BCD 002/BIN 002
BCD 004/BIN 004
BCD 008/BIN 008
BCD 010/BIN 016
0V, GND
BCD 020/BIN 032
BCD 040/BIN 064
BCD 080/BIN 128
BCD 100/BIN 256
BCD 200
+24 V=
CLOCK
PAGE FORWARDS
Programmable Controller
Prog. Cont. outputs
0 DIRECT MESSAGE 1 FIRST MESSAGE
1) log 0 = OV, open input
log 1 = +24 V
= CLOCK
4.3.3 FIRST MESSAGE
With this message variant the LCA 042 can register a maximum of 19 messages in the message memory.
All messages are stored one after the other and the first message is continuously displayed. The other messages can be invoked and displayed as often as desired with function input CLOCK.
When function input DIRECT/SEQUENTIAL becomes “lo­gical 1”, the registration of the messages begins. With a “logic 0” on the input the registration ends and the internal messa-ge memory is erased. The LCA 042 then displays the text of message number 000.
The message memory always registers the last 19 messages. Message 000 is not stored. CLOCK must not last longer than 2s, otherwise cyclic display will take place.
DIRECT/SEQUENTIAL ( 7 ) = 1
1)
TEXT/VARIABLE ( 20 ) = 0 CLOCK ( 8 ) =
The function input DIRECT/ SEQUENTIAL can be driven by the programmable controller or hard-wired. CLOCK (DATA­CLOCK) can be triggered by a key or by the programmable controller.
Page 23
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
12
4.3.4 CYCLIC DISPLAY
With this message variant the LCA 042 can register a maximum of 19 messages.
All messages are stored one after the other and are displayed cyclically.
When function input DIRECT/SEQUENTIAL becomes “lo­gical 1”, the registration of the messages begins. With a “logic 0” on the input the registration ends and the internal message memory is erased. The LCA 042 then displays only the text of message number 000 (information text).
The message memory always registers the last 19 messages. Each message is displayed for approx. 2.5s.
The function input DIRECT/ SEQUENTIAL and CLOCK (DATA-CLOCK) can be driven by the programmable con­troller or hard-wired.
-THE CYCLIC DISPLAY
1) log 0 = OV, open input
log 1 = +24 V
= CLOCK
MESSAGE- or TEXTNUMBER FUNCTION POWER 18 5 17 4 16 3 15 2 14 1 7 20 8 10 25
BCD 001/BIN 001
DIRECT/SEQUENTIAL
BCD 002/BIN 002
BCD 004/BIN 004
BCD 008/BIN 008
BCD 010/BIN 016
0V, GND
BCD 020/BIN 032
BCD 040/BIN 064
BCD 080/BIN 128
BCD 100/BIN 256
BCD 200
+24 V=
CLOCK
CYCLIC DISPLAY
Programmable Controller
Prog. Cont. outputs
0 DIRECT MESSAGE 1 FIRST MESSAGE
1
DIRECT/SEQUENTIAL ( 7 ) = 1
1)
TEXT/VARIABLE ( 20 ) = 0 CLOCK ( 8 ) = 1
Page 24
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
13
-EXTERNAL VARIABLES
VAR 001 ... VAR 008 = BCD variables VAR 001 ... VAR 064 = ASCII variables
BCD 001/BIN 001 VAR 001
BCD 002/BIN 002 VAR 002
BCD 004/BIN 004 VAR 004
BCD 008/BIN 008 VAR 008
BCD 010/BIN 016 VAR 016
BCD 020/BIN 032 VAR 032
BCD 040/BIN 064 VAR 064
TEXT /VARIABLE
BCD 080/BIN 128
BCD 100/BIN 256
BCD 200
0V, GND
0V Signal
+24 V=
CLOCK
0 INVOKE MESSAGES 1 READ IN VARIABLE
VARIABLE IS TAKEN OVER
Programmable Controller
Prog. Cont. outputs
MESSAGE- or TEXTNUMBER FUNCTION POWER 18 5 17 4 16 3 15 2 14 1 7 20 8 22 10 25
OPERATING
VOLTAGE
MESSAGE
Ø54
TEXT
VARIABLE
1st
VARIABLE
2nd
VARIABLE
CLOCK
TIME 1 2 3 4 5 6 7
+ 24V 0 V
log 1 log 0
ON OFF
ON OFF
ON OFF
log 1 log 0
TIME 1: The message 054 (for example) is invoked and displayed
without variables (Time 1-2 >= 74ms)
TIME 2: The function input TEXT/VARIABLE is switched to variable
(Time 2-3 >= 21ms)
TIME 3: The 1st variable is created, CLOCKed into the LCA042 in BCD/
ASCII-code via the message inputs and displayed. The variables are written into the predetermined variable positions from left to right (Time 3-4 >= 15ms)
TIME 4: After the CLOCK there is an “idle time” (Time 4-5 >= 15ms) TIME 5: The 2nd variable is created, CLOCKed into the LCA 042 in BCD/
ASCII-code via the message inputs and displayed. The variables are written into the predetermined variable positions from left to right (Time 5-6 >= 15ms)
TIME 6: After the CLOCK there is an “idle time” (Time 6-7 >= 15ms) TIME 7: The text is displayed with variables until time point 7
4.4 EXTERNAL VARIABLES
External variables are pressures, temperatures, counter values etc. They can be read into any message text line. The variables in an invoked message can be updated as often as desired:
By means of place holders * (asterisks) you can determine the number and position of the variables in a text line:
A maximum of 40 external variables can be written into each text line.
FOIL-TEMP = 85.4 °C (NOM-TEMP = 94.0 °C)
DIRECT/SEQUENTIAL ( 7 ) = 0 TEXT/VARIABLE ( 20 ) = 1
CLOCK ( 8 ) =
FOIL-TEMP = 96.0 °C (NOM-TEMP = 94.0 °C)
FOIL-TEMP = ** * °C (NOM-TEMP = 94.0 °C)
Page 25
© 1989 by SYSTEME LAUER GMBH • D 72669 Unterensingen • Kelterstr. 59 • TEL 07022/ 96600 • FAX 07022/9660103
TEXT DISPLAY LCA 042
14
1) Contacts, proximity switches, programmable controller outputs, etc.
-TEXT DISPLAY WITHOUT PROGRAMMABLE CONTROLLER
Flat cabel LCA 030, LCA 031
UNIVERSAL ADAPTER LCA 024
1)
Programmable Controller connection
+24 V=
5.1 UNIVERSAL ADAPTER LCA 024/025
When text display LCA 042 can not be driven by a pro­grammable controller, for example when used with con­ventional relay controllers, we recommend the use of the universal adapter LCA 024.
Up to 64 limit switches, proximity switches, relays and electronic outputs can be connected to the LCA 024. The text display and the universal adapter are organized in such a way that a “logical 1” on terminal 1 of the LCA 024 invokes message 01 in the text display. The same applies for inputs 3...64. The terminal number corresponds to
the message number. If logical 1 is present on several inputs simultaneously, their messages can be
displayed cyclically or invoked one after the other by means of a key.
If 64 message inputs are not enough, an extension up to 127 inputs is possible using universal adapter expander LCA 025.
For more detailed information see the description of the universal adapter.