Varioshake Shaking Apparatus
VS 8 O, VS 8 B, VS 8 OE, VS 8 BE
VS 15 O, VS 15 B, VS 15 T, VS 15 R
VS 30 O
2 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
3/34
VS 8 OE, VS 8 BE
An electronically geared AC motor as well as a stable and durable
shaking mechanism create two different Shaker types for orbital and
reciprocating motions. The units are designed for use in incubation
rooms. For permissible environmental conditions, please refer to the
technical data of these instructions.
VS 8 O, VS 8 B, VS 15 T, VS 15 R, VS 15 O, VS 15 B, VS 30 O
Electronically geared AC motors as well as stable and durable shaking
mechanisms create seven different Shaking Apparatus models (three
load classes) for four different motions: orbital, reciprocating, orbital
rocking and rocking. Shaking frequency and remaining running time
are LC displayed during operation. It is possible to run the units with
Digital Control Unit via PC (RS 232 – interface optional available).
LAUDA Varioshake Shaking Apparatus are extremely silent and universally applicable, suitable for both, gentle moving of
liquids and vigorous mixing.
Before installation, please check whether contents of package are in good order and complete. Should you note any damages or have any reasons for complaint, please contact your supplier or directly us.
1Use of the Distillation Apparatus .......................................................................................................................................... 7
4Transport, Set-up and Location of the Shaking Apparatus ................................................................................................... 8
5Operating Voltage ................................................................................................................................................................. 8
6Initiation – analog control VS 8 OE, VS 8 BE ..................................................................................................................... 8
6.1
6.2
7Initiation – digital control VS 8 O, VS 8 B, T, R, O, VS 30 O ........................................................................................... 9
9Servicing, maintenance and clearing possible defects ........................................................................................................ 11
9.1
9.2
10 Disposal of Old Units.......................................................................................................................................................... 12
11 Technical Data .................................................................................................................................................................... 13
13 Connection to the mains supply ......................................................................................................................................... 20
13.1
13.2
14 Lists of spare parts .............................................................................................................................................................. 22
Intended Use ................................................................................................................................................................................... 7
Improper Use .................................................................................................................................................................................. 7
Choosing the operation mode...................................................................................................................................................... 8
Choosing the shaking frequency ................................................................................................................................................. 9
Operation and display elements on the control panel ............................................................................................................. 9
Setting shaking frequency and running time ...........................................................................................................................10
Remote control via PC (optional RS 232 - interface) .........................................................................................................10
Exchanging the fuses ...................................................................................................................................................................11
Breakdown in case of overload and mains failure ....................................................................................................................11
Varioshake Shaking Apparatus VS 8 B, VS 8 BE...................................................................................................................13
Varioshake Shaking Apparatus VS 8 O, VS 8 OE .................................................................................................................14
Varioshake Shaking Apparatus VS 15 O, VS 15 B ...............................................................................................................15
Varioshake Shaking Apparatus VS 15 T, VS 15 R ................................................................................................................16
Varioshake Shaking Apparatus VS 30 O .................................................................................................................................17
Varioshake Shaking Apparatus VS 8 OE, VS 8 BE ...............................................................................................................18
Varioshake Shaking Apparatus VS 15 T, VS 15 R, VS 30 O .............................................................................................19
Varioshake Shaking Apparatus VS 8 O, VS 8 B, VS 15 O, VS 15 B ...............................................................................19
Examples for connection to the mains supply .........................................................................................................................21
Varioshake Shaking Apparatus VS 8 OE, VS 8 BE ...............................................................................................................22
Varioshake Shaking Apparatus VS 8 O, VS 8 B ....................................................................................................................23
Varioshake Shaking Apparatus VS 15 T...................................................................................................................................24
Varioshake Shaking Apparatus VS 15 R ..................................................................................................................................25
Varioshake Shaking Apparatus VS 15 O, VS 15 B ...............................................................................................................26
Varioshake Shaking Apparatus VS 30 O .................................................................................................................................27
6 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
7/34
1Use of the Distillation Apparatus
1.1
Intended Use
The information in these operating instructions must by all means be carefully read and observed. Only then a perfect
functioning of the Shaking Apparatus can be guaranteed. The units may only be installed and operated by persons who
have made themselves familiar with these operating instructions. The frequency of the shaking motion can be set and is
electronically regulated. Laboratory vessels that are to be used on the Shaking Apparatus must be fixed safe-to-operate.
The maximum usable shaking frequency is also determined by the kind and weight of the load. Provide sufficient working
space in the vicinity of the unit to put down accessories in use safely.
Caution:
due to increased risk of injury never reach into the unit as long as it is still in motion.
1.2
Improper Use
LAUDA Varioshake Shaking Apparatus, operated in a laboratory, are no Medical Devices. They fall neither under national
nor international Medical Device Directives and have to be used and applied accordingly. The Shaking Apparatus may not
be used in potentially explosive surroundings and may neither be set up nor operated in laboratory areas with aggressive or
corrosive ambient.
By all means make sure to prevent the shaking procedure creating an explosive atmosphere during operation of the Shaking Apparatus.
2Warranty
For all laboratory apparatus and their accessories from LAUDA-GFL, there is a warranty claim, as well for spare parts,
repairs and modifications, carried out by LAUDA-GFL. In order to identify defective units, we require both model and
serial number on the nameplate, on the back of the Shaking Apparatus and, if applicable, a copy of the invoice.
3Before Initiation
The information in these operating instructions must by all means be carefully read and observed. Only then a perfect
functioning of the Shaking Apparatus can be guaranteed. A free of charge guarantee repair cannot be granted for defects
due to improper installation or handling.
Safety precautions are marked with the following symbols
Read and observe the
operating instructions
Warning of dangerous
electrical voltage
Warning of hand injuries
General warning
Before maintenance and repair
disconnect the unit all-pole from
the electrical mains (pull the plug
from the socket).
4Transport, Set-up and Location of the Shaking Apparatus
Protect yourself and the unit during transport and setup by working carefully and avoid danger of e. g. shifting or tilting the
unit. Place on solid, even and level surfaces inside buildings only. The location must provide sufficient space as well as the
necessary carrying capacity for the unit (unit weight as per Technical Data, of this Operating Instructions, plus weight of
the accessories and load). The unit is suitable for bench mounting indoors and for use in incubation and tempering rooms.
For use in incubation and tempering rooms please observe the environmental conditions stated in the Technical Data.
The Shaking Apparatus is not suitable for use in explosion endangered surroundings, e. g. during anaesthesia with inflammable gas or steam types. In some Shaking Apparatus models, a paperboard strip has been inserted as a transport protection between shaking table and housing. The paperboard strip must be removed before installation.
5Operating Voltage
The Shaking Apparatus must be connected to the mains through a correctly installed shock-proof socket or through an
on-site main switch. The Shaking Apparatus is a protection class I electrical appliance, a connection to the earth conductor
(PE) must be ensured. For information on the required mains fuse please view Technical Data of this manual. The electrical connection must ensure an all-pole separation of the Shaking Apparatus from the mains at any time.
The left knob of the unit (only models VS 8 OE and VS 8 BE) must be off (position O). The voltage on
the nameplate (at the back of the unit) must be identical to the mains voltage. If they are identical, connect the unit to the mains. For further information, please also refer to chapter 13 of these operating
instructions "Connection to the Mains Supply".
6Initiation – analog control VS 8 OE, VS 8 BE
Caution:
due to increased risk of injury never reach into the unit as long as it is still in motion.
Caution:
by all means make sure to prevent the shaking procedure creating an explosive atmosphere during operation of the Shaking Apparatus.
Before initiation turn the left-hand control knob anti-clockwise to limit stop (minimum shaking frequency). Then turn
right-hand control knob clockwise until the green pilot lamp glows.
6.1
0.
Choosing the operation mode
For continuous operation turn the knob to the first scale line; the knob will
catch there. To switch off, turn the knob anti-clockwise to position 0. For
timed runs turn the control knob past the scale line for continuous run to
the scale graduation marks for timed runs, showing time limits in minutes.
The maximum timed period is 60 minutes. After expiry of the timed run, the
Shaking Apparatus will be switched off automatically. Timed runs chosen by
mistake can be reversed by turning the control knob anti-clockwise. To
switch off the Shaking Apparatus, turn the control anti-clockwise to position
8 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
9/34
6.2
Choosing the shaking frequency
Turn the left-hand control knob clockwise to increase
the shaking frequency and anti-clockwise to decrease
the shaking frequency.
The shaking frequency ranges of Shaking Apparatus are
stated in the Technical Data of these operating instructions.
7Initiation – digital control VS 8 O, VS 8 B, T, R, O, VS 30 O
Caution:
due to increased risk of injury never reach into the unit as long as it is still in motion.
Caution:
by all means make sure to prevent the shaking procedure creating an explosive atmosphere during operation of the Shaking Apparatus.
To initiate, press switch 1. Displays 2 and 3 show the memorized set points for running time and shaking frequency
7.1
Operation and display elements on the control panel
j To switch the Shaking Apparatus on and off
k Display shows the preset running time and the remaining running time
during operation of the Shaking Apparatus
Display shows the preset or actual shaking frequency
m Switch: to start or to terminate the shaking motion, and to confirm al-
tered set points of shaking frequency and running time
n Switch: to set lower shaking frequency and running time points
Change-over key: switches to setting shaking frequency and running
time points.
Switch: to set higher shaking frequency and running time points.
7.2
After pressing switch 1 to switch on the Shaking Apparatus, displays 2 and 3 show the last set and memorized set points of
running time and shaking frequency. By pressing switch 6 the setting mode of the unit alternates between setting modes
of shaking frequency and running time. Displays 2 and 3 show the respective set point, put in flashing brackets. The respective set point can now be increased using switch 7 or decreased using switch 5.
Altered set points are confirmed using switch 4. The Shaking Apparatus starts operation. The set points are memorized
after switching off the shaking motion with switch 4 and switching off the unit with switch 1
The running time of the Shaking Apparatus can be preset either between 1 minute and 99:59 hours for timed runs or for
continuous operation. Continuous operation can be set with switch 5 in the operation mode and is displayed by the symbol
- - : - -,. The settable shaking frequency range of the various models can be taken from Technical Data of these operating
instructions. Mistakenly preset set points can be altered during operation with switch 6 and switches 5 and 7, and switch
4, as described above. Set points that are altered during operation will not be memorized when the Shaking Apparatus is
switched off with switch 1.
If the Shaking Apparatus is not used for a longer period, it should be separated from the mains.
Setting shaking frequency and running time
7.3
If the Shaking Apparatus is in remote control mode, take special caution in the operation area of the Shaking Apparatus.
The remote control programme may start the Shaking Apparatus at any time.
An interface module with connection at the back of the Shaking Apparatus generates the transmission format RS 232.
The interface allows reading out current actual and set values. In order to set values, the unit has to be switched to remote
control mode via a PC signal. Function of switches 4 – 7 is then blocked. A PC symbol flashes in display 3.
The connection cable between interface and PC must not be longer than 3 metres. After switching on the remote control
mode, the regulator is inactive, the shaking motion is switched off, and the set value is 0.
If the transmitted set value is within the permissible range, the Shaking Apparatus will start shaking at the chosen frequency. The shaking motion is cut off by setting the value to 0. If the Shaking Apparatus is to be operated manually again, the
remote control mode has to be switched off via a PC signal. The PC symbol in the display disappears.
For operation of the RS 232 interface, an interface protocol is available on request. Please advise model and serial numbers of the Shaking Apparatus.
Remote control via PC (optional RS 232 - interface)
Caution:
Before initiation, please check the Shaking Apparatus assembly to make sure that any hazard is excluded.
The Shaking Apparatus must be operated within field of vision.
10 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
11/34
8Functional description
Analog control:
Über ein mechanisches Uhrenlaufwerk wird der Schüttelapparat in der Betriebsart Dauer- oder zeitbegrenzter Betrieb eingeschaltet.
Digital control:
A microprocessor controller regulates the shaking frequency of the Shaking Apparatus in continuous or
timed operation. The Shaker can be operated manually via the control panel as well as in remote control
mode via PC.
All models are equipped with ac motors, protected against overload. The electronic frequency control
ensures a gentle start-up, irrespective of load.
A stable and durable mechanical construction serves to impart the torque of the motor with the specific
shaking motion to the shaking platform.
The four plastic pins on the shaking platform serve to fix the accessories (chapter 15).
9Servicing, maintenance and clearing possible defects
Please make sure that no fluids come into contact with cable connections or the electrical parts of the inside
unit!
Before cleaning and/or opening the unit (only by an electrician!) always pull the plug from the mains socket.
9.1
9.2
Overheating of the Shaking Apparatus due to overload will cause the unit to be switched off. Caution, the unit will restart
automatically after cooling down. After a mains failure, the Shaking Apparatus with digital control will not restart automatically, but has to be restarted as described in chapter 7.2.
If the Shaking Apparatus fails due to any kind of breakdown, the unit must by all means be separated from the mains before it is touched.
LAUDA- GFL Shaking Apparatus are produced with first class materials and are made to withstand even rough service
conditions. Nevertheless, the units should only be subjected to rough conditions within sensible limits. The off-white powder-coated surfaces of the housing and the shaking platform may be cleaned with mild detergents, if necessary.
Exchanging the fuses
The two fuses of the Shaking Apparatus are situated in a drawer at the back of the unit. In
order to check or to exchange these fuses, press the fixing clips on both sides of the drawer
and pull.
The fuses may only be exchanged against fuses of the same type. Information on the fuse
type can be found on the nameplate next to the unit plug and in the spare parts list of these
operating instructions.
Breakdown in case of overload and mains failure
Please do not hesitate to contact your local dealer or us for technical support. In case of complaints please contact your
local dealer or us
LAUDA-GFL Gesellschaft für Labortechnik mbH
Schulze-Delitzsch-Straße 4+5
D-30938 Burgwedel
Servicings, repairs or modifications must be carried out according to the commonly recognised Technical Rules and Regulations by competent electricians only.
Only original spare parts must be used. Always demand a detailed confirmation of the carried out tasks by the person in
charge (company, date, signature).
10Disposal of Old Units
LAUDA-GFL will take responsibility, within the scope of the legal directives, for an environmentally sound handling and
dis-posal of all used LAUDA-GFL units as of the production year 1995 that are returned to us free of charge and will
have it materially recycled. Before the unit is returned, a legally binding declaration must be provided from the sender
confirming that the unit is free from harmful and/or hazardous contaminations as well as from hazardous substances
caused by the previous use of the unit.
LAUDA-GFL laboratory apparatus are exclusively designed for industrial use and may not be disposed of through public
was-te disposal authorities.
EAR Registration Number WEEE-ID.NO.DE 67770231
12 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
13/34
11Technical Data
tion) and the required shaking frequency.
11.1
Exterior dimensions (W x D x H)350 mm x 355 mm x 160 mm350 mm x 375 mm x 160 mm
Shaking platform (W x D)330 mm x 330 mm330 mm x 330 mm
Max. load
depending on the kind of load (even load distribu-
Controldigitalanalog
Shaking motion
Shaking amplitude
Shaking frequency
Timer
Electrical connection115 V or 230 V, +/-10 %, 50 / 60 Hz115 V or 230 V, +/-10 %, 50 / 60 Hz
Mains fuse
Internal fuse
Power65 W65 W
Protection type / classI / IP20I / IP20
Varioshake Shaking Apparatus VS 8 B, VS 8 BE
VS 8 BVS 8 BE
up to max. 8 kgup to max. 8 kg
reciprocating
20 mm
20 - 300 min
1 min to 99:59 hrs or continuous operation
10 A
F1 / F2 500 mA T
-1
reciprocating
20 mm
20 - 300 min
up to 60 min or continuous operation
10 A
F1 / F2 500 mA T
-1
Surrounding conditionsUse only inside buildings.
also in incubation and tempering rooms
(not in explosion endangered surroundings)
Temperature+ 10 °C to + 50 °C+ 10 °C to + 60 °C
Humiditymax. 70 % rel. humidity up to 31 °C,
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
Weight13.0 kg13.0 kg
Use only inside buildings.
also in incubation and tempering rooms
(not in explosion endangered surroundings)
max. 70 % rel. humidity up to 31 °C,
decreasing to 50 % rel. humidity at 60 °C,
non-condensing.
11.2
tion) and the required shaking frequency.
Exterior dimensions (W x D x H)350 mm x 355 mm x 160 mm350 mm x 375 mm x 160 mm
Shaking platform (W x D)330 mm x 330 mm330 mm x 330 mm
Varioshake Shaking Apparatus VS 8 O, VS 8 OE
VS 8 OVS 8 OE
Max. load
depending on the kind of load (even load distribu-
Controldigitalanalog
Shaking motion
Shaking amplitude
Shaking frequency
Timer
Electrical connection115 V or 230 V, +/-10 %, 50 / 60 Hz115 V or 230 V, +/-10 %, 50 / 60 Hz
Mains fuse
Internal fuse
Power65 W65 W
Protection type / classI / IP20I / IP20
Surrounding conditionsUse only inside buildings.
Temperature+ 10 °C to + 50 °C+ 10 °C to + 60 °C
Humiditymax. 70 % rel. humidity up to 31 °C,
up to max. 8 kgup to max. 8 kg
orbital
10 mm
20-300 min
1 min to 99:59 hrs or continuous operation
10 A
F1 / F2 500 mA T
also in incubation and tempering rooms
(not in explosion endangered surroundings)
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
-1
orbital
10 mm
20-500 min
up to 60 min or continuous operation
10 A
F1 / F2 500 mA T
Use only inside buildings.
also in incubation and tempering rooms
(not in explosion endangered surroundings)
max. 70 % rel. humidity up to 31 °C,
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
-1
Weight13.0 kg13.0 kg
14 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
15/34
11.3
tion) and the required shaking frequency.
Exterior dimensions (W x D x H)480 mm x 487 mm x 160 mm480 mm x 487 mm x 160 mm
Shaking platform (W x D)450 mm x 450 mm450 mm x 450 mm
Varioshake Shaking Apparatus VS 15 O, VS 15 B
VS 15 OVS 15 B
Max. load
depending on the kind of load (even load distribu-
Controldigitaldigital
Shaking motion
Shaking amplitude
Shaking frequency
Timer
Electrical connection115 V or 230 V, +/-10 %, 50 / 60 Hz115 V or 230 V, +/-10 %, 50 / 60 Hz
Mains fuse
Internal fuse
Power65 W65 W
Protection type / classI / IP20I / IP20
Surrounding conditionsUse only inside buildings.
Temperature+ 10 °C to + 50 °C+ 10 °C to + 50 °C
Humiditymax. 70 % rel. humidity up to 31 °C,
up to max. 15 kgup to max. 15 kg
orbital
30 mm
20-300 min
1 min to 99:59 hrs or continuous operation
10 A
F1 / F2 500 mA T
also in incubation and tempering rooms
(not in explosion endangered surroundings)
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
-1
reciprocating
30 mm
20-300 min
1 min to 99:59 hrs or continuous operation
10 A
F1 / F2 500 mA T
Use only inside buildings.
also in incubation and tempering rooms
(not in explosion endangered surroundings)
max. 70 % rel. humidity up to 31 °C,
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
-1
Weight23.5 kg23.5 kg
11.4
tion) and the required shaking frequency.
Exterior dimensions (W x D x H)480 mm x 487 mm x 160 mm480 mm x 487 mm x 160 mm
Shaking platform (W x D)450 mm x 450 mm450 mm x 450 mm
Varioshake Shaking Apparatus VS 15 T, VS 15 R
VS 15 TVS 15 R
Max. load
depending on the kind of load (even load distribu-
Controldigitaldigital
Shaking motion
Shaking amplitude
Shaking frequency
Timer
Electrical connection115 V or 230 V, +/-10 %, 50 / 60 Hz115 V or 230 V, +/-10 %, 50 / 60 Hz
Mains fuse
Internal fuse
Power90 W90 W
Protection type / classI / IP20I / IP20
Surrounding conditionsUse only inside buildings.
Temperature+ 10 °C to + 50 °C+ 10 °C to + 50 °C
Humiditymax. 70 % rel. humidity up to 31 °C,
up to max. 15 kgup to max. 15 kg
three-dimensional orbital rocking
3 degrees to horizontal
2-50 min
1 min to 99:59 hrs or continuous operation
10 A
F1 / F2 500 mA T
also in incubation and tempering rooms
(not in explosion endangered surroundings)
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
-1
rocking
3 degrees to horizontal
2-50 min
1 min to 99:59 hrs or continuous operation
10 A
F1 / F2 500 mA T
Use only inside buildings.
also in incubation and tempering rooms
(not in explosion endangered surroundings)
max. 70 % rel. humidity up to 31 °C,
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
-1
Weight23.5 kg23.5 kg
16 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
17/34
11.5
tion) and the required shaking frequency.
Timer
1 min to 99:59 hrs or continuous operation
Internal fuse
F1/F2 500 mA T
(not in explosion endangered surroundings)
non-condensing
.
Exterior dimensions (W x D x H)705 mm x 607 mm x 160 mm
Shaking platform (W x D)676 mm x 540 mm
Varioshake Shaking Apparatus VS 30 O
VS 30 O
Max. load
depending on the kind of load (even load distribu-
Controldigital
Shaking motion
Shaking amplitude
Shaking frequency
Electrical connection115 V or 230 V, +/-10 %, 50 / 60 Hz
Mains fuse
Power90 W
Protection type / classI / IP20
Surrounding conditionsUse only inside buildings.
Temperature+ 10 °C to + 50 °C
Humiditymax. 70 % rel. humidity up to 31 °C,
up to max. 30 kg
orbital
32 mm
20-250 min
(with platform frame 20-200 min-1)
10 A
also in incubation and tempering rooms
decreasing to 50 % rel. humidity at 50 °C,
-1
Weight44.0 kg
12Circuit diagram
12.1
Varioshake Shaking Apparatus VS 8 OE, VS 8 BE
A1Frequency control
A2Forked light barrier
C1Condenser
F1Fuse 500 mA inert
F2Fuse 500 mA inert
F3Fuse 400 mA
H1Operation pilot lamp
M1Drive motor
R1Potentiometer
S1Timer
Timed operation up to 60 minutes and continuous operation
18 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
19/34
12.2
Varioshake Shaking Apparatus VS 15 T, VS 15 R, VS 30 O
12.3
A1Microprocessor-controlled frequency control
A2Forked light barrier
B1Interference filter
C1Condenser
F1Fuse 500 mA inert
F2Fuse 500 mA inert
M1Drive motor
Varioshake Shaking Apparatus VS 8 O, VS 8 B, VS 15 O, VS 15 B
13Connection to the mains supply
ge/gr
–
yellow
/green
bl–blueNsw–black
Model
Power
Power consumption at mains voltage
*
Mains fuse
(F4, F5)
VS 8 B
E
Model
Power
Power consumption at mains voltage
*
Mains fuse
(F4, F5)
VS 15 B
(max. 16 A)
Model
Power
Power consumption at mains voltage
*
Mains
fuse
(F4, F5)
VS 30 O
LAUDA-GFL Varioshake Shaking Apparatus are supplied with a pre-assembled, cast-on shock-proof plug (CEE 7/7).
Make sure to connect to a protective conductor terminal.
Colour coding of the mains cableMains supply
PE (Protective earth)
L1
13.1
VS 8 O
VS 8 B
VS 8 OE
VS 15 O
VS 15 T
VS 15 R
* see nameplate
Electrical fuses
0.065 kW 0.3 A at 230 V10 A
(max. 16 A)
0.065 kW 0.3 A at 230 V10 A
0.090 kW 0.4 A at 230 V10 A
(max. 16 A)
20 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
21/34
13.2
Components
B1 Shock-proof socket (on-site)
B2 Shock-proof plug (mounted on the unit)
F4 Mains fuse (on-site)
F5 Mains fuse (on-site)
Examples for connection to the mains supply
Varioshake Shaking Apparatus in 230 V
with mains supply 230 V / N / PE / 50 / 60 Hz,
connected through 3-pole shock-proof plug system.
Varioshake Shaking Apparatus in 230 V
with mains supply 400 V / 3 ~ / N / PE / 50 / 60 Hz
connected through 3-pole shock-proof plug system.
Varioshake Shaking Apparatus in 230 V
with mains supply 230 V / 3 ~ / PE / 50 / 60 Hz
connected through 3-pole shock-proof plug system.
14Lists of spare parts
14.1
Pos. No. Part-No.Article
10015533Pivot shaft
20014579Knob
30030103Potentiometer
40013309Timer
50012634Green pilot lamp
60026281Flat spring (Set complete)
70026283Ball bearing
80015522Ball bearing seat
9A000097Forked light barrier
100030096Mains connection cable
110012045Drawer
120012915Fine fuse 0,5 A inert
14A000112Driving belt for model VS 8 OE
15A000073Motor (please order together with belt pulley)
160013788Frequency control
170014320Stand
Varioshake Shaking Apparatus VS 8 OE, VS 8 BE
0014580Indicating dial
0017330Driving belt for model VS 8 BE
0015575Belt pulley for model VS 8 OE
0015565Belt pulley for model VS 8 BE
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
22 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
23/34
14.2
Pos. No. Part-No.Article
10015533Pivot shaft
2-5A000101Microprocessor control
60026281Flat spring (Set complete)
70026283Ball bearing
80015522Seat for ball bearing
9A000097Forked light barrier
100030010Mains connection cable
110012045Drawer
120012915Fine fuse 0,5 A T
130012044Unit plug
140026615Driving belt for VS 8 O
15A000073Motor
170014320Stand
Varioshake Shaking Apparatus VS 8 O, VS 8 B
0017330Driving belt for VS 8 B
0015565Belt pulley for VS 8 O
0013737Belt pulley for VS 8 B
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
120012044Unit plug
140026297Flat spring (Set complete with holders)
15A000070Geared motor (Studded disc, pre-assembled, pos. 17, to be ordered with the motor).)
160012847Forked light barrier
170026607Studded disc
180026605Belt
190030119Condenser
200014311Stand
Varioshake Shaking Apparatus VS 30 O
0012915Fine fuse 0,5 A T
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
15Accessories
Shaking Tray with holes to fix clamps for Erlenmeyer flasks and separating funnels, and to fix test tube rack A000059
Part-No. A000044 made of stainless steel for models VS 8
Part-No. A000045 made of stainless steel for models VS 15
Part-No. A000047 made of anodized aluminium for model VS 30 O
Clamps for Erlenmeyer flasks, made of stainless steel. Supplied complete with fixing material to be screwed onto shaking tray A000023.
* =Höchstmengen an Klammern pro Tablar.
Part-No. A000025 for 25 ml Erlenmeyer flasks
Part-No. A000026 for 50 ml Erlenmeyer flasks
Part-No. A000027 for 100 ml Erlenmeyer flasks
Part-No. A000028 for 200 ml Erlenmeyer flasks
Part-No. A000029 for 250-300 ml Erlenmeyer flasks
Part-No. A000030 for 500 ml Erlenmeyer flasks
Part-No. A000031 for 1000 ml Erlenmeyer flasks
Part-No. A000053 for 2000 ml Erlenmeyer flasks
Clamps for separating funnels, made of stainless steel. Supplied complete with fixing material, to be screwed onto a shaking tray.
Part-No. A000054 for 50ml separating funnels
Part-No. A000055 for 100ml separating funnels
Part-No. A000056 for 250ml separating funnels
Part-No. A000057 for 250ml separating funnels (conical form)
Part-No. A000058 for 500ml separating funnels
Non-slip Rubber Mat for slow moving e. g. of culture media in petri
dishes.
Part-No. A000042 for VS 8
Part-No. A000043 for VS 15
28 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
29/34
Universal mount for safe fixing of various shaking objects between
rubber-coated bars.
Part-No. A000048 with 4 rubber-coated bars for VS 8
Part-No. A000049 with 6 rubber-coated bars for VS 15
Universalaufsatz zur sicheren Befestigung unterschiedlicher Schüttelobjekte zwischen gummierten Querstangen
Part-No. A000050 with 6 rubber-coated bars for VS 30
Adhesive mat, black. Strong adhesive special mat for easy attachment
of different vessels onto the shaking platform or tray. Max. shaking
speed: up to 250 min-1 (depending on shape and weight of the vessel
as well as on the shaking amplitude). Dimensions: 200 x 200 mm,
the mat can be cut or trimmed with scissors.
Temperature: 15 bis 50 °C
Part-No. A000041
Holder for fixing test plates on shaking trays
one set, including screwing material
Part-No. A000061
Test Tube Rack, seat for test tubes can be tilted by 90 ° for easy
loading, with springs for firm hold and silent shaking of the tubes.
Supplied complete with fixing material to be screwed onto a shaking
tray.
Part-No. A000059 for 24 tubes 75-160 mm length / Æ 12-17 mm
Part-No. A000060 for 16 tubes 75-160 mm length / Æ 25-29 mm
Platform Frames to increase the capacity of the Shaking Apparatus
made of stainless steel with 4 levels
Part-No. A000051 for VS 15 T and VS 15 R
30 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
31/34
32 / 34Varioshake Shaking Apparatus09/2020
09/2020
Varioshake
Shaking Apparatus
33/34
LAUDA-GFL Gesellschaft für Labortechnik mbH
Schulze-Delitzsch-Straße 4+5◦ 30938 Burgwedel◦ Deutschland
Tel.: +49 (0) 5139 9958-0◦ Fax +49 (0) 5139 9958-21
E-Mail: info@lauda-gfl.de◦ Internet: www.GFL.de
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.