Lauda Shakers Varioshake VS-15 series, circular, VS 15 O User guide

Operating Instructions
Varioshake Shaking Apparatus VS 8 O, VS 8 B, VS 8 OE, VS 8 BE VS 15 O, VS 15 B, VS 15 T, VS 15 R VS 30 O
2 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
3/34
VS 8 OE, VS 8 BE
An electronically geared AC motor as well as a stable and durable shaking mechanism create two different Shaker types for orbital and reciprocating motions. The units are designed for use in incubation rooms. For permissible environmental conditions, please refer to the technical data of these instructions.
VS 8 O, VS 8 B, VS 15 T, VS 15 R, VS 15 O, VS 15 B, VS 30 O
Electronically geared AC motors as well as stable and durable shaking mechanisms create seven different Shaking Apparatus models (three load classes) for four different motions: orbital, reciprocating, orbital rocking and rocking. Shaking frequency and remaining running time are LC displayed during operation. It is possible to run the units with Digital Control Unit via PC (RS 232 – interface optional available).
LAUDA Varioshake Shaking Apparatus are extremely silent and universally applicable, suitable for both, gentle moving of liquids and vigorous mixing.
Before installation, please check whether contents of package are in good order and complete. Should you note any damag­es or have any reasons for complaint, please contact your supplier or directly us.
LAUDA-GFL Gesellschaft für Labortechnik mbH
Schulze-Delitzsch-Str. 4+5
30938 Burgwedel - Deutschland
Telefon: +49 (0)5139 9958 0
Fax: +49 (0)5139 9958 21
E-Mail:info@lauda-gfl.de
Internet: www.gfl.de
4 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
5/34
Contents
Operating Instructions ................................................................................................................................................................... 1
1 Use of the Distillation Apparatus .......................................................................................................................................... 7
1.1
1.2
2 Warranty ................................................................................................................................................................................ 7
3 Before Initiation ..................................................................................................................................................................... 7
4 Transport, Set-up and Location of the Shaking Apparatus ................................................................................................... 8
5 Operating Voltage ................................................................................................................................................................. 8
6 Initiation – analog control VS 8 OE, VS 8 BE ..................................................................................................................... 8
6.1
6.2
7 Initiation – digital control VS 8 O, VS 8 B, T, R, O, VS 30 O ........................................................................................... 9
7.1
7.2
7.3
8 Functional description ........................................................................................................................................................ 11
9 Servicing, maintenance and clearing possible defects ........................................................................................................ 11
9.1
9.2
10 Disposal of Old Units.......................................................................................................................................................... 12
11 Technical Data .................................................................................................................................................................... 13
11.1
11.2
11.3
11.4
11.5
12 Circuit diagram ................................................................................................................................................................... 18
12.1
12.2
12.3
13 Connection to the mains supply ......................................................................................................................................... 20
13.1
13.2
14 Lists of spare parts .............................................................................................................................................................. 22
14.1
14.2
14.3
14.4
14.5
14.6
15 Accessories .......................................................................................................................................................................... 28
Intended Use ................................................................................................................................................................................... 7
Improper Use .................................................................................................................................................................................. 7
Choosing the operation mode...................................................................................................................................................... 8
Choosing the shaking frequency ................................................................................................................................................. 9
Operation and display elements on the control panel ............................................................................................................. 9
Setting shaking frequency and running time ...........................................................................................................................10
Remote control via PC (optional RS 232 - interface) .........................................................................................................10
Exchanging the fuses ...................................................................................................................................................................11
Breakdown in case of overload and mains failure ....................................................................................................................11
Varioshake Shaking Apparatus VS 8 B, VS 8 BE...................................................................................................................13
Varioshake Shaking Apparatus VS 8 O, VS 8 OE .................................................................................................................14
Varioshake Shaking Apparatus VS 15 O, VS 15 B ...............................................................................................................15
Varioshake Shaking Apparatus VS 15 T, VS 15 R ................................................................................................................16
Varioshake Shaking Apparatus VS 30 O .................................................................................................................................17
Varioshake Shaking Apparatus VS 8 OE, VS 8 BE ...............................................................................................................18
Varioshake Shaking Apparatus VS 15 T, VS 15 R, VS 30 O .............................................................................................19
Varioshake Shaking Apparatus VS 8 O, VS 8 B, VS 15 O, VS 15 B ...............................................................................19
Electrical fuses ..............................................................................................................................................................................20
Examples for connection to the mains supply .........................................................................................................................21
Varioshake Shaking Apparatus VS 8 OE, VS 8 BE ...............................................................................................................22
Varioshake Shaking Apparatus VS 8 O, VS 8 B ....................................................................................................................23
Varioshake Shaking Apparatus VS 15 T...................................................................................................................................24
Varioshake Shaking Apparatus VS 15 R ..................................................................................................................................25
Varioshake Shaking Apparatus VS 15 O, VS 15 B ...............................................................................................................26
Varioshake Shaking Apparatus VS 30 O .................................................................................................................................27
6 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
7/34
1 Use of the Distillation Apparatus
1.1
Intended Use
The information in these operating instructions must by all means be carefully read and observed. Only then a perfect functioning of the Shaking Apparatus can be guaranteed. The units may only be installed and operated by persons who have made themselves familiar with these operating instructions. The frequency of the shaking motion can be set and is electronically regulated. Laboratory vessels that are to be used on the Shaking Apparatus must be fixed safe-to-operate. The maximum usable shaking frequency is also determined by the kind and weight of the load. Provide sufficient working space in the vicinity of the unit to put down accessories in use safely.
Caution: due to increased risk of injury never reach into the unit as long as it is still in motion.
1.2
Improper Use
LAUDA Varioshake Shaking Apparatus, operated in a laboratory, are no Medical Devices. They fall neither under national nor international Medical Device Directives and have to be used and applied accordingly. The Shaking Apparatus may not be used in potentially explosive surroundings and may neither be set up nor operated in laboratory areas with aggressive or corrosive ambient. By all means make sure to prevent the shaking procedure creating an explosive atmosphere during operation of the Shak­ing Apparatus.
2 Warranty
For all laboratory apparatus and their accessories from LAUDA-GFL, there is a warranty claim, as well for spare parts, repairs and modifications, carried out by LAUDA-GFL. In order to identify defective units, we require both model and serial number on the nameplate, on the back of the Shaking Apparatus and, if applicable, a copy of the invoice.
3 Before Initiation
The information in these operating instructions must by all means be carefully read and observed. Only then a perfect functioning of the Shaking Apparatus can be guaranteed. A free of charge guarantee repair cannot be granted for defects due to improper installation or handling.
Safety precautions are marked with the following symbols
Read and observe the
operating instructions
Warning of dangerous electrical voltage
Warning of hand injuries
General warning
Before maintenance and repair disconnect the unit all-pole from the electrical mains (pull the plug from the socket).
4 Transport, Set-up and Location of the Shaking Apparatus
Protect yourself and the unit during transport and setup by working carefully and avoid danger of e. g. shifting or tilting the unit. Place on solid, even and level surfaces inside buildings only. The location must provide sufficient space as well as the necessary carrying capacity for the unit (unit weight as per Technical Data, of this Operating Instructions, plus weight of the accessories and load). The unit is suitable for bench mounting indoors and for use in incubation and tempering rooms. For use in incubation and tempering rooms please observe the environmental conditions stated in the Technical Data. The Shaking Apparatus is not suitable for use in explosion endangered surroundings, e. g. during anaesthesia with inflam­mable gas or steam types. In some Shaking Apparatus models, a paperboard strip has been inserted as a transport protec­tion between shaking table and housing. The paperboard strip must be removed before installation.
5 Operating Voltage
The Shaking Apparatus must be connected to the mains through a correctly installed shock-proof socket or through an on-site main switch. The Shaking Apparatus is a protection class I electrical appliance, a connection to the earth conductor (PE) must be ensured. For information on the required mains fuse please view Technical Data of this manual. The electri­cal connection must ensure an all-pole separation of the Shaking Apparatus from the mains at any time.
The left knob of the unit (only models VS 8 OE and VS 8 BE) must be off (position O). The voltage on the nameplate (at the back of the unit) must be identical to the mains voltage. If they are identical, con­nect the unit to the mains. For further information, please also refer to chapter 13 of these operating instructions "Connection to the Mains Supply".
6 Initiation – analog control VS 8 OE, VS 8 BE
Caution: due to increased risk of injury never reach into the unit as long as it is still in motion.
Caution: by all means make sure to prevent the shaking procedure creating an explosive atmosphere during opera­tion of the Shaking Apparatus.
Before initiation turn the left-hand control knob anti-clockwise to limit stop (minimum shaking frequency). Then turn right-hand control knob clockwise until the green pilot lamp glows.
6.1
0.
Choosing the operation mode
For continuous operation turn the knob to the first scale line; the knob will catch there. To switch off, turn the knob anti-clockwise to position 0. For timed runs turn the control knob past the scale line for continuous run to the scale graduation marks for timed runs, showing time limits in minutes. The maximum timed period is 60 minutes. After expiry of the timed run, the Shaking Apparatus will be switched off automatically. Timed runs chosen by mistake can be reversed by turning the control knob anti-clockwise. To switch off the Shaking Apparatus, turn the control anti-clockwise to position
8 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
9/34
6.2
Choosing the shaking frequency
Turn the left-hand control knob clockwise to increase the shaking frequency and anti-clockwise to decrease the shaking frequency.
The shaking frequency ranges of Shaking Apparatus are stated in the Technical Data of these operating instruc­tions.
7 Initiation – digital control VS 8 O, VS 8 B, T, R, O, VS 30 O
Caution: due to increased risk of injury never reach into the unit as long as it is still in motion.
Caution: by all means make sure to prevent the shaking procedure creating an explosive atmosphere during opera­tion of the Shaking Apparatus.
To initiate, press switch 1. Displays 2 and 3 show the memorized set points for running time and shaking frequency
7.1
Operation and display elements on the control panel
j To switch the Shaking Apparatus on and off
k Display shows the preset running time and the remaining running time
during operation of the Shaking Apparatus
Display shows the preset or actual shaking frequency
m Switch: to start or to terminate the shaking motion, and to confirm al-
tered set points of shaking frequency and running time
n Switch: to set lower shaking frequency and running time points
Change-over key: switches to setting shaking frequency and running
time points.
Switch: to set higher shaking frequency and running time points.
7.2
After pressing switch 1 to switch on the Shaking Apparatus, displays 2 and 3 show the last set and memorized set points of running time and shaking frequency. By pressing switch 6 the setting mode of the unit alternates between setting modes of shaking frequency and running time. Displays 2 and 3 show the respective set point, put in flashing brackets. The re­spective set point can now be increased using switch 7 or decreased using switch 5. Altered set points are confirmed using switch 4. The Shaking Apparatus starts operation. The set points are memorized after switching off the shaking motion with switch 4 and switching off the unit with switch 1 The running time of the Shaking Apparatus can be preset either between 1 minute and 99:59 hours for timed runs or for continuous operation. Continuous operation can be set with switch 5 in the operation mode and is displayed by the symbol
- - : - -,. The settable shaking frequency range of the various models can be taken from Technical Data of these operating instructions. Mistakenly preset set points can be altered during operation with switch 6 and switches 5 and 7, and switch 4, as described above. Set points that are altered during operation will not be memorized when the Shaking Apparatus is switched off with switch 1. If the Shaking Apparatus is not used for a longer period, it should be separated from the mains.
Setting shaking frequency and running time
7.3
If the Shaking Apparatus is in remote control mode, take special caution in the operation area of the Shaking Apparatus. The remote control programme may start the Shaking Apparatus at any time. An interface module with connection at the back of the Shaking Apparatus generates the transmission format RS 232. The interface allows reading out current actual and set values. In order to set values, the unit has to be switched to remote control mode via a PC signal. Function of switches 4 – 7 is then blocked. A PC symbol flashes in display 3. The connection cable between interface and PC must not be longer than 3 metres. After switching on the remote control mode, the regulator is inactive, the shaking motion is switched off, and the set value is 0. If the transmitted set value is within the permissible range, the Shaking Apparatus will start shaking at the chosen frequen­cy. The shaking motion is cut off by setting the value to 0. If the Shaking Apparatus is to be operated manually again, the remote control mode has to be switched off via a PC signal. The PC symbol in the display disappears. For operation of the RS 232 interface, an interface protocol is available on request. Please advise model and serial num­bers of the Shaking Apparatus.
Remote control via PC (optional RS 232 - interface)
Caution: Before initiation, please check the Shaking Apparatus assembly to make sure that any hazard is excluded. The Shaking Apparatus must be operated within field of vision.
10 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
11/34
8 Functional description
Analog control: Über ein mechanisches Uhrenlaufwerk wird der Schüttelapparat in der Betriebsart Dauer- oder zeitbe­grenzter Betrieb eingeschaltet.
Digital control: A microprocessor controller regulates the shaking frequency of the Shaking Apparatus in continuous or timed operation. The Shaker can be operated manually via the control panel as well as in remote control mode via PC.
All models are equipped with ac motors, protected against overload. The electronic frequency control ensures a gentle start-up, irrespective of load. A stable and durable mechanical construction serves to impart the torque of the motor with the specific shaking motion to the shaking platform.
The four plastic pins on the shaking platform serve to fix the accessories (chapter 15).
9 Servicing, maintenance and clearing possible defects
Please make sure that no fluids come into contact with cable connections or the electrical parts of the inside unit! Before cleaning and/or opening the unit (only by an electrician!) always pull the plug from the mains socket.
9.1
9.2
Overheating of the Shaking Apparatus due to overload will cause the unit to be switched off. Caution, the unit will restart automatically after cooling down. After a mains failure, the Shaking Apparatus with digital control will not restart automati­cally, but has to be restarted as described in chapter 7.2. If the Shaking Apparatus fails due to any kind of breakdown, the unit must by all means be separated from the mains be­fore it is touched. LAUDA- GFL Shaking Apparatus are produced with first class materials and are made to withstand even rough service conditions. Nevertheless, the units should only be subjected to rough conditions within sensible limits. The off-white pow­der-coated surfaces of the housing and the shaking platform may be cleaned with mild detergents, if necessary.
Exchanging the fuses
The two fuses of the Shaking Apparatus are situated in a drawer at the back of the unit. In order to check or to exchange these fuses, press the fixing clips on both sides of the drawer and pull. The fuses may only be exchanged against fuses of the same type. Information on the fuse type can be found on the nameplate next to the unit plug and in the spare parts list of these operating instructions.
Breakdown in case of overload and mains failure
Please do not hesitate to contact your local dealer or us for technical support. In case of complaints please contact your local dealer or us
LAUDA-GFL Gesellschaft für Labortechnik mbH Schulze-Delitzsch-Straße 4+5 D-30938 Burgwedel
Servicings, repairs or modifications must be carried out according to the commonly recognised Technical Rules and Regu­lations by competent electricians only.
Only original spare parts must be used. Always demand a detailed confirmation of the carried out tasks by the person in charge (company, date, signature).
10 Disposal of Old Units
LAUDA-GFL will take responsibility, within the scope of the legal directives, for an environmentally sound handling and dis-posal of all used LAUDA-GFL units as of the production year 1995 that are returned to us free of charge and will have it materially recycled. Before the unit is returned, a legally binding declaration must be provided from the sender confirming that the unit is free from harmful and/or hazardous contaminations as well as from hazardous substances caused by the previous use of the unit. LAUDA-GFL laboratory apparatus are exclusively designed for industrial use and may not be disposed of through public was-te disposal authorities. EAR Registration Number WEEE-ID.NO.DE 67770231
12 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
13/34
11 Technical Data
tion) and the required shaking frequency.
11.1
Exterior dimensions (W x D x H) 350 mm x 355 mm x 160 mm 350 mm x 375 mm x 160 mm Shaking platform (W x D) 330 mm x 330 mm 330 mm x 330 mm
Max. load depending on the kind of load (even load distribu-
Control digital analog
Shaking motion Shaking amplitude Shaking frequency Timer
Electrical connection 115 V or 230 V, +/-10 %, 50 / 60 Hz 115 V or 230 V, +/-10 %, 50 / 60 Hz Mains fuse
Internal fuse Power 65 W 65 W Protection type / class I / IP20 I / IP20
Varioshake Shaking Apparatus VS 8 B, VS 8 BE
VS 8 B VS 8 BE
up to max. 8 kg up to max. 8 kg
reciprocating 20 mm 20 - 300 min 1 min to 99:59 hrs or continuous operation
10 A F1 / F2 500 mA T
-1
reciprocating 20 mm 20 - 300 min up to 60 min or continuous operation
10 A F1 / F2 500 mA T
-1
Surrounding conditions Use only inside buildings.
also in incubation and tempering rooms
(not in explosion endangered surroundings) Temperature + 10 °C to + 50 °C + 10 °C to + 60 °C Humidity max. 70 % rel. humidity up to 31 °C,
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
Weight 13.0 kg 13.0 kg
Use only inside buildings. also in incubation and tempering rooms (not in explosion endangered surroundings)
max. 70 % rel. humidity up to 31 °C, decreasing to 50 % rel. humidity at 60 °C, non-condensing.
11.2
tion) and the required shaking frequency.
Exterior dimensions (W x D x H) 350 mm x 355 mm x 160 mm 350 mm x 375 mm x 160 mm Shaking platform (W x D) 330 mm x 330 mm 330 mm x 330 mm
Varioshake Shaking Apparatus VS 8 O, VS 8 OE
VS 8 O VS 8 OE
Max. load depending on the kind of load (even load distribu-
Control digital analog
Shaking motion Shaking amplitude Shaking frequency Timer
Electrical connection 115 V or 230 V, +/-10 %, 50 / 60 Hz 115 V or 230 V, +/-10 %, 50 / 60 Hz Mains fuse
Internal fuse Power 65 W 65 W Protection type / class I / IP20 I / IP20
Surrounding conditions Use only inside buildings.
Temperature + 10 °C to + 50 °C + 10 °C to + 60 °C Humidity max. 70 % rel. humidity up to 31 °C,
up to max. 8 kg up to max. 8 kg
orbital 10 mm 20-300 min 1 min to 99:59 hrs or continuous operation
10 A F1 / F2 500 mA T
also in incubation and tempering rooms (not in explosion endangered surroundings)
decreasing to 50 % rel. humidity at 50 °C, non-condensing.
-1
orbital 10 mm 20-500 min up to 60 min or continuous operation
10 A F1 / F2 500 mA T
Use only inside buildings. also in incubation and tempering rooms (not in explosion endangered surroundings)
max. 70 % rel. humidity up to 31 °C, decreasing to 50 % rel. humidity at 50 °C, non-condensing.
-1
Weight 13.0 kg 13.0 kg
14 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
15/34
11.3
tion) and the required shaking frequency.
Exterior dimensions (W x D x H) 480 mm x 487 mm x 160 mm 480 mm x 487 mm x 160 mm Shaking platform (W x D) 450 mm x 450 mm 450 mm x 450 mm
Varioshake Shaking Apparatus VS 15 O, VS 15 B
VS 15 O VS 15 B
Max. load depending on the kind of load (even load distribu-
Control digital digital
Shaking motion Shaking amplitude Shaking frequency Timer
Electrical connection 115 V or 230 V, +/-10 %, 50 / 60 Hz 115 V or 230 V, +/-10 %, 50 / 60 Hz Mains fuse
Internal fuse Power 65 W 65 W Protection type / class I / IP20 I / IP20
Surrounding conditions Use only inside buildings.
Temperature + 10 °C to + 50 °C + 10 °C to + 50 °C Humidity max. 70 % rel. humidity up to 31 °C,
up to max. 15 kg up to max. 15 kg
orbital
30 mm
20-300 min
1 min to 99:59 hrs or continuous operation
10 A
F1 / F2 500 mA T
also in incubation and tempering rooms
(not in explosion endangered surroundings)
decreasing to 50 % rel. humidity at 50 °C,
non-condensing.
-1
reciprocating 30 mm 20-300 min 1 min to 99:59 hrs or continuous operation
10 A F1 / F2 500 mA T
Use only inside buildings. also in incubation and tempering rooms (not in explosion endangered surroundings)
max. 70 % rel. humidity up to 31 °C, decreasing to 50 % rel. humidity at 50 °C, non-condensing.
-1
Weight 23.5 kg 23.5 kg
11.4
tion) and the required shaking frequency.
Exterior dimensions (W x D x H) 480 mm x 487 mm x 160 mm 480 mm x 487 mm x 160 mm Shaking platform (W x D) 450 mm x 450 mm 450 mm x 450 mm
Varioshake Shaking Apparatus VS 15 T, VS 15 R
VS 15 T VS 15 R
Max. load depending on the kind of load (even load distribu-
Control digital digital
Shaking motion Shaking amplitude Shaking frequency Timer
Electrical connection 115 V or 230 V, +/-10 %, 50 / 60 Hz 115 V or 230 V, +/-10 %, 50 / 60 Hz Mains fuse
Internal fuse Power 90 W 90 W Protection type / class I / IP20 I / IP20
Surrounding conditions Use only inside buildings.
Temperature + 10 °C to + 50 °C + 10 °C to + 50 °C Humidity max. 70 % rel. humidity up to 31 °C,
up to max. 15 kg up to max. 15 kg
three-dimensional orbital rocking 3 degrees to horizontal 2-50 min 1 min to 99:59 hrs or continuous operation
10 A F1 / F2 500 mA T
also in incubation and tempering rooms (not in explosion endangered surroundings)
decreasing to 50 % rel. humidity at 50 °C, non-condensing.
-1
rocking 3 degrees to horizontal 2-50 min 1 min to 99:59 hrs or continuous operation
10 A F1 / F2 500 mA T
Use only inside buildings. also in incubation and tempering rooms (not in explosion endangered surroundings)
max. 70 % rel. humidity up to 31 °C, decreasing to 50 % rel. humidity at 50 °C, non-condensing.
-1
Weight 23.5 kg 23.5 kg
16 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
17/34
11.5
tion) and the required shaking frequency.
Timer
1 min to 99:59 hrs or continuous operation
Internal fuse
F1/F2 500 mA T
(not in explosion endangered surroundings)
non-condensing
.
Exterior dimensions (W x D x H) 705 mm x 607 mm x 160 mm Shaking platform (W x D) 676 mm x 540 mm
Varioshake Shaking Apparatus VS 30 O
VS 30 O
Max. load depending on the kind of load (even load distribu-
Control digital
Shaking motion Shaking amplitude Shaking frequency
Electrical connection 115 V or 230 V, +/-10 %, 50 / 60 Hz Mains fuse
Power 90 W Protection type / class I / IP20
Surrounding conditions Use only inside buildings.
Temperature + 10 °C to + 50 °C Humidity max. 70 % rel. humidity up to 31 °C,
up to max. 30 kg
orbital
32 mm
20-250 min
(with platform frame 20-200 min-1)
10 A
also in incubation and tempering rooms
decreasing to 50 % rel. humidity at 50 °C,
-1
Weight 44.0 kg
12 Circuit diagram
12.1
Varioshake Shaking Apparatus VS 8 OE, VS 8 BE
A1 Frequency control A2 Forked light barrier C1 Condenser F1 Fuse 500 mA inert F2 Fuse 500 mA inert F3 Fuse 400 mA H1 Operation pilot lamp M1 Drive motor R1 Potentiometer S1 Timer
Timed operation up to 60 minutes and continuous operation
18 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
19/34
12.2
Varioshake Shaking Apparatus VS 15 T, VS 15 R, VS 30 O
12.3
A1 Microprocessor-controlled frequency control A2 Forked light barrier B1 Interference filter C1 Condenser F1 Fuse 500 mA inert F2 Fuse 500 mA inert M1 Drive motor
Varioshake Shaking Apparatus VS 8 O, VS 8 B, VS 15 O, VS 15 B
13 Connection to the mains supply
ge/gr
yellow
/green
bl–blueNsw–black
Model
Power
Power consumption at mains voltage
*
Mains fuse
(F4, F5)
VS 8 B
E
Model
Power
Power consumption at mains voltage
*
Mains fuse
(F4, F5)
VS 15 B
(max. 16 A)
Model
Power
Power consumption at mains voltage
*
Mains
fuse
(F4, F5)
VS 30 O
LAUDA-GFL Varioshake Shaking Apparatus are supplied with a pre-assembled, cast-on shock-proof plug (CEE 7/7). Make sure to connect to a protective conductor terminal.
Colour coding of the mains cable Mains supply
PE (Protective earth)
L1
13.1
VS 8 O VS 8 B VS 8 OE
VS 15 O
VS 15 T VS 15 R
* see nameplate
Electrical fuses
0.065 kW 0.3 A at 230 V 10 A (max. 16 A)
0.065 kW 0.3 A at 230 V 10 A
0.090 kW 0.4 A at 230 V 10 A (max. 16 A)
20 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
21/34
13.2
Components B1 Shock-proof socket (on-site) B2 Shock-proof plug (mounted on the unit) F4 Mains fuse (on-site) F5 Mains fuse (on-site)
Examples for connection to the mains supply
Varioshake Shaking Apparatus in 230 V with mains supply 230 V / N / PE / 50 / 60 Hz, connected through 3-pole shock-proof plug system.
Varioshake Shaking Apparatus in 230 V with mains supply 400 V / 3 ~ / N / PE / 50 / 60 Hz connected through 3-pole shock-proof plug system.
Varioshake Shaking Apparatus in 230 V with mains supply 230 V / 3 ~ / PE / 50 / 60 Hz connected through 3-pole shock-proof plug system.
14 Lists of spare parts
14.1
Pos. No. Part-No. Article
1 0015533 Pivot shaft 2 0014579 Knob
3 0030103 Potentiometer 4 0013309 Timer 5 0012634 Green pilot lamp 6 0026281 Flat spring (Set complete) 7 0026283 Ball bearing 8 0015522 Ball bearing seat 9 A000097 Forked light barrier 10 0030096 Mains connection cable 11 0012045 Drawer 12 0012915 Fine fuse 0,5 A inert 14 A000112 Driving belt for model VS 8 OE
15 A000073 Motor (please order together with belt pulley)
16 0013788 Frequency control 17 0014320 Stand
Varioshake Shaking Apparatus VS 8 OE, VS 8 BE
0014580 Indicating dial
0017330 Driving belt for model VS 8 BE
0015575 Belt pulley for model VS 8 OE 0015565 Belt pulley for model VS 8 BE
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
22 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
23/34
14.2
Pos. No. Part-No. Article
1 0015533 Pivot shaft 2-5 A000101 Microprocessor control 6 0026281 Flat spring (Set complete) 7 0026283 Ball bearing 8 0015522 Seat for ball bearing 9 A000097 Forked light barrier 10 0030010 Mains connection cable 11 0012045 Drawer 12 0012915 Fine fuse 0,5 A T 13 0012044 Unit plug 14 0026615 Driving belt for VS 8 O
15 A000073 Motor
17 0014320 Stand
Varioshake Shaking Apparatus VS 8 O, VS 8 B
0017330 Driving belt for VS 8 B
0015565 Belt pulley for VS 8 O 0013737 Belt pulley for VS 8 B
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
14.3
Pos. No. Part-No. Article
1 0015533 Pivot shaft 2 A000101 Microprocessor control 3 0015417 Ball brass 4 0015416 Ball pivot 5 0015536 Drive shaft 6 0026283 Ball bearing 7 0015522 Seat for ball bearing 8 0012798 Condenser 9 0013778 RS232 interface 10 0030116 Mains suppression filter 11 0030010 Mains connection cable 12 0012045 Drawer
13 0012044 Unit plug 15 0012141 Geared motor 16 0026606/10 Studded disc d=10mm 17 0012847 Forked light barrier 18 0026604 Toothed belt 19 0013311 Stand 20 0014310 Rubber / metal buffer
Varioshake Shaking Apparatus VS 15 T
0012915 Fine fuse 0,5 A T
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
24 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
25/34
14.4
Pos. No. Part-No. Article
1 0015533 Pivot shaft 2 A000101 Microprocessor control 3 0026269 Slide bearing 4 0015416 Ball pivot 5 0015417 Ball brass 6 0015141 Connecting rod 7 0014310 Rubber / metal buffer 8 0012798 Condenser 9 0013778 RS232 interface, optional 10 0030116 Mains suppression filter 11 0030010 Mains connection cable 12 0012045 Drawer
13 0012044 Unit plug 15 0012141 Geared motor 16 0012847 Forked light barrier 17 0015485 Ball bearing seat 18 0026264 Ball bearing 19 0015484 Eccentric 20 0014311 Stand
Varioshake Shaking Apparatus VS 15 R
0012915 Fine fuse 0,5 A T
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
14.5
Pos. No. Part-No. Article
1 0015533 Pivot shaft 2 A000101 Microprocessor control 3 0026285 Flat spring (Set complete) 4 0026283 Ball bearing 5 0015522 Seat for ball bearing 6 A000097 Forked light barrier 7 0013778 RS232 interface, optional 8 0030116 Mains suppression filter 9 0030010 Mains connection cable 10 0012045 Drawer
11 0012044 Unit plug 13 A000112 Driving belt 14 A000073 Motor
15 0014320 Stand
Varioshake Shaking Apparatus VS 15 O, VS 15 B
0012915 Fine fuse 0,5 A T
0015531 Beltpulley for motor
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
26 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
27/34
14.6
Pos. No. Part-No. Article
1 0015464 Adjusting ring 2 0015463 Support rod 3 A000101 Microprocessor control 4 0025408 Securing ring 5 0026257 Ball bearing
5.1 0015211 Upper ball bearing seat (incl. ball bearing Pos. No.5, pre-assembled)
5.2 0015210 Lower ball bearing seat (incl. ball bearing Pos. No.5, pre-assembled)) 6 0025407 Securing ring 7 0014310 Rubber metal buffer 8 0013778 RS232 interface, optional 9 0030116 Mains suppression filter 10 0030010 Mains connection cable 11 0012045 Drawer
12 0012044 Unit plug 14 0026297 Flat spring (Set complete with holders) 15 A000070 Geared motor (Studded disc, pre-assembled, pos. 17, to be ordered with the motor).) 16 0012847 Forked light barrier 17 0026607 Studded disc 18 0026605 Belt 19 0030119 Condenser 20 0014311 Stand
Varioshake Shaking Apparatus VS 30 O
0012915 Fine fuse 0,5 A T
Please always state model and serial no of the water still when placing an order for spare parts (information on name plate).
15 Accessories
Shaking Tray with holes to fix clamps for Erlenmeyer flasks and sepa­rating funnels, and to fix test tube rack A000059
Part-No. A000044 made of stainless steel for models VS 8 Part-No. A000045 made of stainless steel for models VS 15 Part-No. A000047 made of anodized aluminium for model VS 30 O
Clamps for Erlenmeyer flasks, made of stainless steel. Supplied com­plete with fixing material to be screwed onto shaking tray A000023. * =Höchstmengen an Klammern pro Tablar.
Part-No. A000025 for 25 ml Erlenmeyer flasks Part-No. A000026 for 50 ml Erlenmeyer flasks Part-No. A000027 for 100 ml Erlenmeyer flasks Part-No. A000028 for 200 ml Erlenmeyer flasks Part-No. A000029 for 250-300 ml Erlenmeyer flasks Part-No. A000030 for 500 ml Erlenmeyer flasks Part-No. A000031 for 1000 ml Erlenmeyer flasks Part-No. A000053 for 2000 ml Erlenmeyer flasks
Clamps for separating funnels, made of stainless steel. Supplied com­plete with fixing material, to be screwed onto a shaking tray.
Part-No. A000054 for 50ml separating funnels Part-No. A000055 for 100ml separating funnels Part-No. A000056 for 250ml separating funnels Part-No. A000057 for 250ml separating funnels (conical form) Part-No. A000058 for 500ml separating funnels
Non-slip Rubber Mat for slow moving e. g. of culture media in petri dishes.
Part-No. A000042 for VS 8 Part-No. A000043 for VS 15
28 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
29/34
Universal mount for safe fixing of various shaking objects between rubber-coated bars.
Part-No. A000048 with 4 rubber-coated bars for VS 8 Part-No. A000049 with 6 rubber-coated bars for VS 15
Universalaufsatz zur sicheren Befestigung unterschiedlicher Schüt­telobjekte zwischen gummierten Querstangen
Part-No. A000050 with 6 rubber-coated bars for VS 30
Adhesive mat, black. Strong adhesive special mat for easy attachment of different vessels onto the shaking platform or tray. Max. shaking speed: up to 250 min-1 (depending on shape and weight of the vessel as well as on the shaking amplitude). Dimensions: 200 x 200 mm, the mat can be cut or trimmed with scissors. Temperature: 15 bis 50 °C
Part-No. A000041
Holder for fixing test plates on shaking trays one set, including screwing material
Part-No. A000061
Test Tube Rack, seat for test tubes can be tilted by 90 ° for easy loading, with springs for firm hold and silent shaking of the tubes. Supplied complete with fixing material to be screwed onto a shaking tray.
Part-No. A000059 for 24 tubes 75-160 mm length / Æ 12-17 mm Part-No. A000060 for 16 tubes 75-160 mm length / Æ 25-29 mm
Platform Frames to increase the capacity of the Shaking Apparatus made of stainless steel with 4 levels
Part-No. A000051 for VS 15 T and VS 15 R
30 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
31/34
32 / 34 Varioshake Shaking Apparatus 09/2020
09/2020
Shaking Apparatus
33/34
LAUDA-GFL Gesellschaft für Labortechnik mbH Schulze-Delitzsch-Straße 4+5 30938 Burgwedel Deutschland Tel.: +49 (0) 5139 9958-0 Fax +49 (0) 5139 9958-21 E-Mail: info@lauda-gfl.de Internet: www.GFL.de