STEELCRAFT PRODUCTS
P.O. Box 90365 - Pasadena, CA 91109
PHN 626-798-7401 FAX 626-798-1482
MODEL
FLP-30
FOUL POLE
30'
3
2
5
ITEM QTY. PART NO DESCRIPTION
1 1 F04F P03X 5-9/16" OD Sch 40 POST
32F02FP000SCREEN
4 18 P 01FP000 BOLT/WASH/NUT
52F02FP001CLIPS
INSTAL LATION INSTRUCTIO NS
1. DI G FOOTING AT PROPER LOCATION
30" DIA. X 78" DEEP
2. PLACE BASE POST (1) I NTO FOOTING
AND SUPPORT IN A PLUMB CO NDITION
WITH THE OUTSIDE E DGE OF PIPE TANGENT
TO THE OUTSIDE OF THE FOUL LINE.
TOP OF POST TO BE 9'-0" ABOVE FIN. GRADE
(NOT TOP OF SLEEVE)
3. INSTAL L THE PANELS IN THE TOP POST (2)
USING THE CLIPS (5) AND BOLTS (4) . TIGHTEN
4. AFTER CONCRETE HAS SET 16 hrs. PLACE
THE TOP POST (2) IN BASE PO ST USING A
LIFTING DEVICE (CRANE) ROTATE THE POST
SO THAT TH E PANELS ARE TO THE INS IDE
OF THE FIELD
5. REPEAT FOR OTHER FOUL LINE
1
8'
GROUND LINE
ANTI-ROTATIONAL
PLATES
6'-0"
INSTALL IN 30" DIA. X 78" DEEP
CONCRETE FOOTING
NOTE: SPECIFICATIONS ARE SUBJECT TO CHANGE
DO NOT SCALE DRAWING
DATE: 1/17/06
AVAILABLE
SURFACE MOUNTED
15" X 15" X 1"
STEEL PLATE
FLP-30SM
SURFACE MOUNT DETAIL
DRAWN BY: AFS