Operating and maintenance manual
150515
ELECTRONICS WATER SOFTENERS
Balugani S.r.l. - Divisione Trattamento Acqua
via Iacobella ,11 – Villanova di Denore – Ferrara (FE)-Italy
tel.+39 0532 427485 – fax. +39 0532 427487
www.baluganisrl.it
Operating temperature: min. 5°C – max 50°C
Operating pressure min 1,8 bar - max 5 bar
Power supply: 230v/50Hz (230V\12Vcc by electrical transformer supplied)
Average Capacity
(with input water hardness = 40°F)
Automatic BAV softener family have electronic head that provides a system of regeneration of the
resins in volume, which is preferable to the chronometric system because the software in the
microprocessor of our electronic volumetric controller enables the start-up of the resin regeneration
only when necessary, or only when a certain volume of water has passed through the resin..
The technology of these electronic controllers is internationally patented and certified according to the
requirements of "CE", "RoHS" and NSF.
In a low water comsumption state, the water softener will regenerate the resin every 3 days (this is
programmable data).
Operating Conditions
BAV WATER SOFTENERS MUST BE USED FOR ALREADY DRINKING WATER TREATMENT ONLY;
SHOULD NOT BE USED FOR OTHER USES, TAMPERED OR MODIFIED.
ANY OTHER USE MUST BE CONSIDERED IMPROPER AND POTENTIALLY DANGEROUS.
THE PRODUCER CAN NOT BE HELD RESPONSIBLE FOR ANY DAMAGE DUE TO MISUSE AND
UNREASONABLE USE.
THE WATER SOFTENER MUST NOT BE USED TO TREAT DIFFERENT LIQUIDS THAN WATER.
USE PURE SALT TABS ONLY INTO THE BRINE TANK.
ALWAYS CHECK THAT THE ELECTRICAL CONNECTION IS COMPATIBLE WITH ELECTRICAL DATA
DEVICE TO BE CONNECTED.
IS FORBIDDEN WASH THE WATER SOFETENER BY JETS OF WATER.
IS FORBIDDEN REMOVE THE WATER SOFTENER CONTROL VALVE PROTECTIONS.
FOR ANY DEVICE REPAIRS, REFER TO AUTHORIZED SERVICE CENTER.
Connections and installation
Brine line
connector
DRAIN
The installation must be carried out as required by the regulations in force in the country
where the installation is performed by qualified and authorized personnel.
Incorrect installation can cause damage to the environment , people, animals and objects
for which the manufacturer declines all responsibility.
Please note that an optimal positioning of the softener will be useful when you make the
necessary routine maintenance , repairs in the field and the loading of salt in the container
of the brine.
The drain hose should be connected permanently to the appropriate hose ( see Image
above ) , verifying that the tube is of flexible type , of appropriate section and that there are
no bends along its length .
The drain hose must not be immersed in wells with standing water because it could cause
a backflow of water into the water sostener.
The excessive environmental heat or freezing can severely damage the water softener is
recommended that you place it in places with temperatures not lower than 2 ° C and no
higher than 50 degrees Celsius.
For optimal functionality of the water softener, minimum inlet water pressure must be 1,8
bar and maximum inlet water pressure must be 5 bar.
The softener BAV has been designed for the treatment of cold water and temperature limits
are : minimum 5 ° C and maximum 45 ° C.