Laskomex CD-3100, CP-3110, CP-3110T, CP-3120T, CP-3110VT Installation, Service And Programming Instruction

...
CD-3100xx
INSTALLATION, SERVICE AND
PROGRAMMING INSTRUCTION
DIGITAL ENTRY PHONE
SYSTEM
Contents
1 Conditions of operation 4
2 Installation of entry phone 5
3 Elements of entry phone 6
4 Numbering modes 10
4.1 Normal mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2 Numbering mode with range shift . . . . . . . . . . . . . . . . . . 11
4.3 Hotel numbering mode . . . . . . . . . . . . . . . . . . . . . . . . 11
4.4 Mode with building numbering . . . . . . . . . . . . . . . . . . . 12
4.5 Range of operated numbers . . . . . . . . . . . . . . . . . . . . . 12
4.6 Additional numbers . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.7 Number directing . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5 Configurations of entry phone operation 13
5.1 Basic system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2 System with entrance hierarchy . . . . . . . . . . . . . . . . . . . 14
6 Installation and activation 16
6.1 Performance of wiring system . . . . . . . . . . . . . . . . . . . . 16
6.2 Wiring system of entry phone in audio version . . . . . . . . . . . 16
6.3 Wiring system of entry phone in video version . . . . . . . . . . . 17
6.4 Installation of external panel . . . . . . . . . . . . . . . . . . . . . 19
6.5 Installation of electronic cassette and power supply adaptor . . . . 20
6.6 Assembly of MRL-1 modules . . . . . . . . . . . . . . . . . . . . . 21
6.7 Assembly of CVP-2 commutator . . . . . . . . . . . . . . . . . . . 21
6.8 Installation of distributor CVR–1 and CVR–2 . . . . . . . . . . . . 22
6.9 Installation of monitor and additional cameras . . . . . . . . . . . 24
6.10 Installation and programming of uniphone . . . . . . . . . . . . . . 24
6.11 Adjustment of the doorphone system CD-3100 . . . . . . . . . . . 24
6.12 Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7 Programming of entry phone 27
7.1 P-0 Entering PIN code of external panel . . . . . . . . . . . . . . 28
7.2 P-1 Operation parameters of entry phone . . . . . . . . . . . . . . 29
7.3 P-2 Functions realized by entry phone . . . . . . . . . . . . . . . . 32
7.4 P-3 Installation procedure . . . . . . . . . . . . . . . . . . . . . . 33
7.5 P-4 Electronic keys . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.6 P-5 Individual settings . . . . . . . . . . . . . . . . . . . . . . . . 38
7.7 P-6 Change of installing specialist‘s code . . . . . . . . . . . . . . 41
7.8 P-7 Electro-catch test . . . . . . . . . . . . . . . . . . . . . . . . 41
7.9 P-8 Release of electro-catch in service mode . . . . . . . . . . . . 41
1
7.10 P-9 Change of coded lock code . . . . . . . . . . . . . . . . . . . 41
8 Entry phone use 42
8.1 Connection with apartment . . . . . . . . . . . . . . . . . . . . . 42
8.2 Connection from the main entrance . . . . . . . . . . . . . . . . . 42
8.3 Use of uniphone . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
8.4 Monitor usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8.5 Using coded lock function . . . . . . . . . . . . . . . . . . . . . . 44
8.6 Using electric keys . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8.7 User‘s menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
9 Restoring the initial settings 47
10 Maintenance of entry phone 48
11 Conformity with previous versions 48
12 Messages about faults 49
13 Technical data 49
13.1 Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . 49
13.2 Description of terminals . . . . . . . . . . . . . . . . . . . . . . . 49
14 Dimensions of elements 52
15 Selection of wires and connection diagrams 57
2
Advantages of the doorphone system
For the Fitter
Doorphone system uses only one type of electronic cassette with defined in­tended purpose of use (operating the main/subordinate entrance).
Outer panels can be fed from lo cal feeders, what makes it possible to eliminate thick and expensive cables to feed panels and to operate electro-catch.
To one electro-cassette, from one to four outer panels can be connected.
Doorphone has been provided with procedures facilitating start-up of the whole system.
For the Contractor
Outer panel has been made from materials resistant to corrosion and acts of vandalism.
Panel has been protected against theft by means of PIN code
Doorphone effectively protects the building from any access of unauthorized persons, decreasing a risk of damage or destruction of internal infrastructure. Simultaneously, it enables easy and comfortable access to the building for its occupants.
Low cost of installation per one occupant.
Electronic touch key. Property administrators as well as technical services can use only one key to enter all objects, which are subjected to their administration.
For the User
Digital doorphones are equipped with combination lock functions. For each apartment, the four-digit code is determined which, when given, realizes un­blocking of entrance.
Doorphone CD-3100 allows for usage of electronic touch key.
Selection of one from 9 predefined signals with the possibility of their individual setting for each apartment.
Videomonitor enables connection of additional camera e.g. in front of the entrance
3
1 CONDITIONS OF OPERATION
NOTE!
Entry phone CD-3100 is available in two versions: audio and video. In both versions the same electronic cassette EC-3100 and power supply adapters are used, in both versions parameters are set in the same way. The two versions differ mainly with the types of used panels, additional elements in video version (panels in video ver­sion, switches, distributors and monitors) and the method of performance of power system. Both versions of entry system are described in the instruction. In case of installation and activation of audio version one should disregard recommendations referring to video version.
In entry phone CD-3100 one type of electronic cassette is used - EC-3100. The use of the device (main or subordinate entrance) is defined by program. In the description abbreviations are used — exchange configured for the service of the main entrance is designated EC-3100/H and exchange for the service of subor­dinate entrance EC-3100/U. Cassettes are default configured as EC-3100/U.
1 Conditions of operation
Prior to the installation and use of an entry phone one should get acquainted with the installation and operation instruction.
Wiring system should be performed according to standard PN-IEC-60364-1 by an authorized person. It should be made in such a way as to avoid the risk of lightning.
Monitor should be mounted in a place that is easily accessible for users at a height of min. 1.5 m, in such a way as to eliminate the danger for the users and accidental jostling. Monitor should be installed at a distance of min.
1.5 m from the sources of strong electromagnetic interferences — transformer feeders, magnets, metal sewage and gas pipes because it can result in picture distortion.
It is forbidden to connect the entry phone elements to installations other than made according to the recommendation of an entry phone producer.
Monitor, uniphone and electronic cassette should not be exposed to high tem­perature or humidity. These elements should not be installed in bathrooms or close to heaters.
Openings in a monitor and uniphone should not be covered because it can result in their improper operation.
No metal objects can be put into the openings in uniphones or monitors because this can cause electric shock or fire.
El. supply from external supply sources should not be connected to uniphone terminals because it can cause its damage or fire.
4
2 INSTALLATION OF ENTRY PHONE
It is forbidden to hold the receiver at an ear and push the lever in the uniphone base at the same time (this does not refer to door op ening pushbutton and internal call). This may cause a loud call signal in a receiver that can result in hearing defect.
It is forbidden to repair the entry phone equipment by unauthorized persons because it may cause a threat to health and life.
El. supply from sources of parameters other than recommended by a producer should not be connected to uniphone terminals. Producer will not bear respon­sibility for losses resulting from the use of improper feeders.
Neither petroleum nor any solvents or strong detergents can be used for the cleaning of entry phone elements because they may cause damage of the equip­ment surface.
Picture distortion appearing during rain or right after raining is transient and connected with collection of water in the area of lens and is not the sign of equipment defect.
Signals from entry phones should not be sent to RTV sets because his may result in the damage of such sets or entry phone.
Outside panels should not be sealed with e.g. silicone b ecause it worsens ventilation and leads to corrosion.
2 Installation of entry phone
The following items include the most important stages of design, performance and activation of an entry phone system. Item numbers in instruction containing the detailed information are given in brackets.
1. Get acquainted with the operation instructions especially with the entry phone conditions of use.
2. Define the final configuration, operation mode and then select the necessary elements (chapter 3, page 6, chapter 5, page 13).
3. Define the place of installation of the system elements.
4. Design the wiring system for the accepted configuration (chapter 5.2, page 16), select the kind and cross sections of wires (chapter 15, page 57).
5. Define logical and physical equipment addresses (chapter 4, page 10).
6. Install the equipment of the entry phone system and connect according to the connection diagram.
7. Activate the system.
8. Set the operation parameters of the entry phone system. If possible, inform occupants about entry phone use and hand out codes of coded locks.
5
3 ELEMENTS OF ENTRY PHONE
9. In case the system of entrance hierarchy is activated, set the range limits for the apartments in cassettes operating as EC-3100/U (for subordinate entrances)
- chapter 7.2, page 31. Leaving default settings in these cassettes may cause wrong operation of the entry phone system.
10. Check the operation of the system using the installation procedure.
11. In case of need tune the acoustic path (chapter 6.11, page 24).
3 Elements of entry phone
Electronic cassette
In entry phone CD-3100 one type of electronic cassette is used — EC–3100 for main or subordinate entrances. Its operation mode is defined by an installing specialist. The cassette operates in default setting in U mode and is used for subordinate entrance. Service of the main entrance (operation in mode H) requires the change of cassette configuration (see programming, page 29).
External panel
For CD-3100 system a few types of external panels were designer. Panels are produced in audio and video version (colour camera and LED lighting). They are made of zinc coated sheet covered with powder paint or of stainless steel; in all panel optical keyboard is used. Panels may be equipped with an electronic touch key reader. Electronic key is an alternative to a combination lock, it is also a very good replacement of a traditional mechanic key because it is lighter and more com­fortable in use. Furthermore, an electronic key may be easily programmed in any number of entry phones equipped with readers. The following external panels are available:
CP–3100/xx standard panel in colour xx CP–3100T/xx panel with key reader CP–3100N/xx panel with a list of o ccupants CP–3100VT/xx panel in video version with key reader and black-white
camera CP–3110T panel in audio version made of stainless steel (horizontal) CP–3120T panel in audio version made of stainless steel (vertical) CP–3110VT panel of stainless steel in video version (horizontal) and
colour video camera CP–3120VT panel of stainless steel in video version (vertical) and colour
video camera
6
3 ELEMENTS OF ENTRY PHONE
Illuminator in panels in version video makes it possible to recognize the face at a distance of approx. 50 cm from the video camera. Lighting diodes are placed behind the display, so they are effective only if the face of a visiting person is directed towards the entry phone keyboard. In CD-3100 system to one electronic cassette EC-3100/U (configured to operate subordinate entrance) it is possible to connect from 1 up to 3 outer panels, to cassette EC-3100/H - from 1 up to 4. One from the panels can be fed from the electronic cassette, whereas the others must be fed from the local feeders; because of it, to the places where such panels will be mounted, voltage from power network should be supplied and location for feeder installation should be foreseen. Connection of more than one panel requires application of MRL-1 module.
Uniphones
Uniphones for digital Laskomex entry phones co-op erate with digital entry phone system CD-3100. They are models: LF–8, LT–8, LX–8, LR–8 or LM–8 in all vari­eties. Uniphone LM–8W/1 has an additional switch to control the gateway drive. The use of uniphones of other producers is not recommended because it may cause the wrong operation of the whole entry phone system. Uniphone LM–8W/3 is equipped with a highly effective receiver which ensures call signal louder by approx. 6 dB than in standard LM-8 uniphone. Uniphone LM–8W/4 has a door-bell function. Additional terminals in the uni­phone enable the connection of bell button. Pressing the button results in switching on the gong. Uniphone requires additional supply.
Loud speaking Uniphone LG-8 and LG-8D
Uniphone LG-8 is intended for digital entry phone systems produced by Laskomex (CD-2502 and CD-3100). Uniphone LG-8 operates in simplex system — during the conversation the user must press TALK pushbutton when he is speaking. Uniphone LG-8D operates in duplex system (conversation is possible in both directions without activating buttons or switches). Uniphone requires external supply from central feeder 15V DC/ 4A (up to 40 uniphones) or own feeder 15V DC/1A . Uniphone functions also as a door-bell. Bell button is connected to two terminals in uniphone and its pressing results in generating gong signal in uniphone. Detailed information on connection, programming and use of uniphone LG-8 is included in the instruction enclosed to it.
Monitor MV-6450
Black-white monitor is intended for usage with the doorphone system CD-3100 in video version. MV-6450 - this is black-white monitor with CRT screen and receiver to lead con­versation. One additional camera situated e.g. in front of the entrance can be
7
3 ELEMENTS OF ENTRY PHONE
connected to the monitor. Monitor will not co-operate with video-doorphones man­ufactured by other producers or analog video-doorphones.
Monitor MV-6451
Monitor fulfills the same functions as MV-6450, but it enables to connect up to 3 additional cameras. In order to switch images received from a successive camera, a push-button situated on the monitor is used.
Monitor MVC–6550 and 6650
Colour monitors for Laskomex digital systems. They are loud speaking monitors without receivers with TFT display operating in duplex system. Detailed information on monitor assembly and use are included in the instruction enclosed to them.
Signal distributor CVR-1 and CVR-2.
Vision signal distributor is intended for the entry phone in video version. It en­ables connecting the monitors to entry phone installation or branching the electrical installation of entry phone. Furthermore, distributor amplifies vision signal. Electric system, which connects electronic cassette with monitors, is made in form of bus-bar with distributors CVR-x on the floors. Wires from monitors should be routed to the distributors. The installation method is important - wire should be routed from one distributor to the next one and in the distributor at the end of bus-bar the line load should be configured properly (see dwg 13, page 23). Signal distributor has one input of signals L+,L-,C+,C- with screw terminals (ARK) and four independent outputs with sockets RJ 45 (CVR-1) or ARK (CVR-2). Distributor CVR-1 does not require power supply adaptor – it is supplied from mon­itors connected to it, although it has clamps enabling supplying it from other source e.g. electronic cassette EC-2502. It is used when the distributor operates as signal adapter. Distributor CVR-2 require external power supply adaptor, which can be also used to supply monitors. In the distributor there is an amplifying and correction system of video signal al­lowing optimal adjustment of distributor parameters to the parameters of electrical system.
Video signal change-over switch CVP-2
Change-over switch CVP-2 is intended for usage with doorphone in video version. It is used to switch over video signals received from cameras situated in various outer panels. The change-over switch located at the main entrance enables connection of signals received from maximum four panels. The one used at the slave entrance can switch over video signals received from maximum 3 outer panels and from one from main entrances. The change-over switch includes two signal outputs X and Y, which can be used in order to branch signal within the doorphone installation.
8
3 ELEMENTS OF ENTRY PHONE
In case of necessity to distribute signal between more branches, signal distributor CVR-x should be used. The change-over switch is fed from the electronic cassette (clamps +V and G), and does not require any separate feeder. The command signal to control the change-over switch is supplied to the input CS. The change­over switch performs simultaneously a function of amplifier and signal correction scheme. Switching the correction scheme on and amplification rate for both outputs X and Y are determined by the position of jumpers set on the junction JP3. The commutator includes junctions with jumpers enabling setting of input and output impedance for a given commutator (see page 21).
Module MRL-1
Module MRL-1 is used with doorphones in multi-entrance version. This module is used in order to connect several panels to one electronic cassette. In case of the doorphone system CD-3100 with one entrance, it is possible to connect panel directly to the electronic cassette. Installation of next panels requires application of MRL-1 module.
Power supply
Ac power supply adapter ZS-K-25/01 art.0018 or TSZZM 25/021M should be used for supplying electronic cassette. In CD-3100 system one external panel and one electronic cassette can be together fed from this power supply. The other panels must be fed from the local feeders. To supply external panels it should be used stabilized feeders 13,5V DC/1A.
Electro-catch
In case of entry phone CD-3100 it is recommended to use electro-catches for a voltage of 12V AC/DC and current consumption not exceeding 1A. Action time is subject to programming and may be changed by the fitter. Doorphone CD-3100 does not operate electromagnetic locks.
Door opening pushbutton.
This push-button is used to unblock electro-catch when leaving the object e.g. in the situation, when on the door or wicket from its inside no handle has been mounted but only knob. The push-button can be any coupling push-button e.g. bell-push or robb ery push­button in emergency systems.
Additional call module PW-1
The module enables an additional call signal (acoustic or optical) in the uniphone. It is used in a situation when a uniphone is installed in a room of high noise level or
9
4 NUMBERING MODES
there are partially deaf people in a room. It enables - during calling - the activation of any equipment supplied by voltage 12...24V AC - bell, siren or signaling lamp.
External panel casing
As a standard external panels and lists of occupants are delivered in a frame mounted under plaster, casings enable their mounting on plaster.
DA1 – one segment casing mounted for panels CP-3100xx
DA2H – two segment casing, horizontal, for panels CP-3100xx
DA2V – two segment casing, vertical, for panels CP-3100xx
DA3H – three segment casing, horizontal, for panels CP-3100xx
DA3V – three segment casing, vertical, for panels CP-3100xx
NP3000 – list of occupants for panels CP-3100xx
NP-2511 – horizontal list of occupants for panel CP-3110
NP-2512 – vertical list of occupants for panel CP-3110
NP-2521 – horizontal list of occupants for panel CP-3120
NP-2522 – vertical list of occupants for panel CP-3120
Accumulator
The accumulator can be connected to the electronic cassette. It is used to feed the doorphone installation in the case of voltage collapse in power network. The accumulator is connected to the electronic cassette so in case of voltage collapse only the panel fed from the electronic cassette will operate in a correct way.
4 Numbering modes
Digital entry phone as a standard can operate numbers within a range 1...255, however, very often it is necessary to operate higher numbers or numbers of con­siderably wider range. This is possible owing to different numbering modes.
4.1 Normal mode
In normal mode physical number of uniphone (programmed by jumpers) corre­sponds to logical number (selected from the keyboard of talking cassette). This is a default mode of operation of entry phone exchange.
10
4.2 Numbering mode with range shift 4 NUMBERING MODES
4.2 Numbering mode with range shift
In this numbering mode physical number of a uniphone (programmed by jumpers) differs from its logical number (under which a uniphone rings after having selected the number from the keyboard). This numbering mode is used for apartments of numbers higher than 255.
logical number = physical number + range shift
This numbering mode is switched on in a moment of setting of parameter value ‘range shift‘ to the value higher than ‘0‘.
Example:
In a building an entry phone should be used for apartments Nos. 301...310.
In uniphones physical numbers should be programmed as follows: in apartment 301 number 1, in apartment 302 number 2 etc.
Then cassette programming mode should be entered (see item 7, page 27) and the parameter of range shift should be set to value 300.
After having done this and selecting from a keyboard number 301 the uniphone in which number 1 has been programmed will ring, after having selected number 302 uniphone with number 2 will ring etc.
4.3 Hotel numbering mode
This numbering mode is meant for the buildings in which room number starts with a digit defining number of floor on which the room is located (hotels, resort houses, dormitories etc.). Physical number of a uniphone is calculated according to the formula:
Physical number = P * LL + XX (A)
where P- floor number, LL- amount of rooms on one floor (value of parameter [LPi]) - see dwg. 30), XX- number of room on the floor - number from the range 1 ... [LPi].
This numbering mode will be activated at the moment of setting the value of parameter [LPi] ”amount of rooms on a floor” to value higher than zero.
Example: An entry phone should be mounted in a five-storied building in which the numbering system is as follows: on the ground floor 1 . . .20, on the first floor 101 . . . 102 etc. There are 20 rooms on the ground floor. On next floors, after taking into account full hundred numbers which are also taken into consideration in calculations (100, 200, 300, ...) we get 21 numbers for each floor. First of all the cassette programming mode should be entered and parameter [LPi] (amount of rooms on the floor) should be set to value 21. After quitting the programming mode the exchange operates in hotel numbering mode.
11
4.4 Mode with building numbering 4 NUMBERING MODES
Then it should be defined which logical numbers will correspond to individual phys­ical numbers of uniphones. To do this a formula or a calculator available in one of entry phone programming procedures in the exchange can be used (P-3-5, P-3-6).
numbers of rooms 1... 20 uniphone number 1, 2, ..20 ground floor numbers of rooms 101...120 uniphone number 21, 22,...41 I floor numbers of rooms 201...220 uniphone number 42, 42,...62 II floor
............. ......... ............. ............. ........
numbers of rooms 601...620 uniphone number 125, 126,...146 VI floor
Finally uniphones should be programmed to the numbers settled before. Total number of uniphones used in this numbering mode should not exceed 255.
4.4 Mode with building numbering
This numbering mode can be used only in entry phone system with entrance hierarchy. In order to get connection with an apartment from an external panel at the main entrance one should first of all select building number and then apartment number. This numbering mode allows repeating apartment numbers in different buildings. The following operations should be made in order to activate this mode:
In electronic cassette for subordinate entrance set parameter [n bl] (block num­ber) in procedure P-2 to value higher then zero. (see dwg. 33). To get connection with any apartment in this staircase the apartment number should be preceded by set number (see dwg. 30).
The operation should be repeated for other staircases (buildings). Values [n bl] can be repeated in subordinate systems provided that these systems operate with other logical numbers of uniphones.
In electronic cassette for main entrance set the value of parameter [nrbl] to 1.
4.5 Range of operated numbers
In numbers entry phone the range of operated numbers can be limited. (see dwg.
31). In default setting the operation of all apartment numbers is included. If the range is limited, selection of a number outside the set range will result in displayed message [OFF].
Limiting is set for physical not logical numbers!
Limiting of the range should be set especially in electronic cassettes for subor­dinate entrances (multi-entrance system with entrance hierarchy) because leaving default range setting may hamper using or make impossible the activation of the whole entry phone system. Default set range 1...250.
12
4.6 Additional numbers 5 CONFIGURATIONS OF ENTRY PHONE OPERATION
4.6 Additional numbers
In many cases it is necessary to operate numbers which do not belong to the operated range. In entry phone CD-3100 these numbers can be associated with four physical numbers: 251...254. For each of the mentioned numbers it is possible to set individually any number from the range 1...9998.
4.7 Directing the numbers that are not serviced
In entry phone CD-3100 all numbers which are not operated by entry phone CD-3100 can be directed to one selected number. Owing to this entry phone CD-3100 can be used in a single-family home – entry phone can be configured in such a way that any number selected by the keyboard will result in entry phone ringing at one selected number.
5 Configurations of entry phone operation
5.1 Basic system
MRL-1
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
10
6
6
8
2
EC-3100/U
CP-xxxx
CP-xxxx
CP-xxxx
2
2
2
2 2 2
230V
2
230V
2
230V
4
Figure 1: Basic system, audio version
MRL-1
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
CVP-2
1 2 3 4 5 6 7 8 9
0 C
CVR-1
230V
12
8 8
2
2
2
8
8
4
8
8
EC-3100/U
CP-xxxx
CP-xxxx
230V
5
2
2
230V
4
CVR-2
6
6
2
230V2230V2230V2230V
2
230V
Figure 2: Basic system, video version
In its basic version, the doorphone operates one staircase or one building with one, two or three entrances. At each entrance outer panels are mounted. Conversation with the occupants living in a given staircase or building can be led by means of any outer panel. At the same moment, only one panel can be used and during
13
5.2 System with entrance hierarchy 5 CONFIGURATIONS OF ENTRY PHONE OPERATION
the conversation on displays of the other panels, the message [ZAJ] will appear. Moreover, in video version the occupants will be able additionally to observe the calling person on the monitor.
5.2 System with entrance hierarchy
In case of the system with entrance hierarchy two types of entrances can be distinguished: main (master) entrances and slave (subordinate) entrances. CD-3100 can operate from one up to four main entrances and up to 64 staircases (buildings) with slave entrances. From one up to three slave entrances can lead to each staircase (see Fig. 3). In practice the maximum number of subordinate entrances (served by the electronic cassette EC-3100/U) depends on system connections ­wires length, theirs profile and configuration. L+/L- line resistance between the furthest electronic‘s cassettes shouldn‘t exceed 10W. By means of panels situated at
BUILDING 1 BUILDING 15
FENCING OF THE BUILDING AREA
WG
WGWG
WP
WP WP
WP
WP
WP
WG - main entrance, WP - subordinate (slave) entrance
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3
4 5 6
7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
Figure 3: Multi-entrance system
main entrances, connection can be established with each apartment in any building or staircase. By means of panels situated at slave entrances, connection can be established only with the apartments located in the staircase or the building, to which a given entrance is leading. At the same moment, when one panel is used, on displays of the other panels the message [ZAJ] will appear informing that temporarily they cannot be used. If during conversation led from the slave entrance in one of the buildings (staircases) an attempt to establish connection from the main entrance with any apartment in such a building (staircase) will be carried out, then such earlier conversation will be interrupted and an attempt to establish connection from the main entrance will follow. An electro-catch shall always b e released at this entrance, from which the call has been made. Combination lock and electronic key can be used both at the main entrance and at the slave entrance. Doorphone has been provided with the function of ”quick entrance”, facilitating usage of doorphone systems with the main entrance (see page 42). In the Fig. 5, a scheme illustrating certain sections of doorphone wiring system and the required number of cables are presented.
14
5.2 System with entrance hierarchy 5 CONFIGURATIONS OF ENTRY PHONE OPERATION
MRL-1
1 2 3 4 5 6 7 8 9
0 C
MRL-1
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
EC-3100/H
230V
4
230V
2
230V
2
EC-3100/U
6
6
6
2
6
6
6
2
8
8
2
2
2
2
2
230V
2
2
2
10
230V
2
230V
2
230V
2
230V
4
MAIN ENTRANCE
SUBORDINATE ENTRANCE
Figure 4: System with entrance hierarchy, audio version
MRL-1
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
CVP-2
1 2 3 4 5 6 7 8 9
0 C
MRL-1
1 2 3 4 5 6 7 8 9
0 C
1 2 3 4 5 6 7 8 9
0 C
CVP-2
1 2 3 4 5 6 7 8 9
0 C
CVR-1
230V
2
2
2
2
2
2
2
8
8
8
8
8
8
8
5
6
6
8
8
4
4
4
8
8
230V
2
230V
2
230V
2
230V
2
230V
2
1 2 3 4 5 6 7 8 9
0 C
12
230V
4
EC-3100
EC-3100
CVR-2
6
6
2
230V
2
230V
2
230V2230V
230V
4
2
230V
MAIN ENTRANCE
SUBORDINATE ENTRANCE
Figure 5: System with entrance hierarchy, video version
15
6 INSTALLATION AND ACTIVATION
6 Installation and activation of entry phone
6.1 Performance of wiring system
Entry phone CD-3100 is available in audio and video version. Performance of wiring system depends on the version of entry phone.
General recommendations on performance of wiring system
Electrical system should be made according to standard PN-IEC 60364-1 by a person authorized to make such installations.
Wire cross section depends on the distance between the elements that are connected (see chapter ”Selection of wires”, page 57). In order to ensure proper cross section the selected connections can be doubled or wires of larger diameters can be used.
Operation mode is set in electronic cassette. Depending on the selection they can function as cassettes servicing the main entrance (EC-3100/H) or subor­dinate entrance (EC-3100/U). Default setting of the cassette is configured to operate with the subordinate entrance.
It is recommended that electronic cassette, feeder, module MRL-1 and commu­tator CVP-2 are situated in the installation box. The feeder should be installed at such a distance, it could be connected by means of the original cable.
To electronic cassette configured as EC-3100/U it is possible to connect from 1 up to 3 outer panels. One from them can be fed from EC-3100/U, whereas two others - from the own, local feeders.
To electronic cassette configured as EC-3100/H it is possible to connect from 1 up to 4 outer panels. One of them can be fed from EC-3100/H, whereas two others - from the own, local feeders.
The length of cable connecting the outer panel with the electronic cassette in case when the panel is fed from the electronic cassette, should not exceed 50 m (on condition that correct sections of cables are secured).
Cables to be conducted in the ground should be provided with anti-wet protec­tion.
It is recommended to route all cables as away as possible from other installa­tions. The cables of entry phone system should be routed at a distance not smaller than 20 cm from power cables.
6.2 Wiring system of entry phone in audio version
In section between external panel and electronic cassette spiral wire of dia. min. 0.5 mm should be used. Minimal number of entry phone wires amounts 16 for entry phone without gateway drive control and additional 2 with gateway control. Wires YTKSY, UTP, LAN T11 can be used.
16
6.3 Wiring system of entry phone in video version 6 INSTALLATION AND ACTIVATION
Connection between electronic cassette and uniphones should be made by means of any double wire e.g. YTDY. In case of gate control min. 4 wire conductor should be used.
In audio version the routing of wiring system from electronic cassette to uni­phones does not make any difference. Each uniphone can be connected by a separate wire, wiring can be router from one uniphone to the next one or uniphones can be connected on a common bus-bar. The distance between a uniphone and an electronic cassette should not exceed 150m.
EC-3100
230 VAC
4
Power supply
2 2 2 2 2 2 2
Figure 6: Method of connecting uniphones to electronic cassette.
6.3 Wiring system of entry phone in video version
Video signal in CD-3100 system is sent by symetric line. This solution assures of small sensibility of line for external interference. It also allows to send video on relatively far distance but demends to comply with some rules with wiring system.
In section between external panel and electronic cassette spiral wire of dia. min.
0.5 mm and impedance 100should be used. Minimal number of entry phone wires amounts 18 for entry phone without gateway drive control and 20 with gateway control.
Section: external panel - electronic cassette should be made of telecommu­nication cable or UTP spiral (e.g. XzTKMXpw, YTKSY, UTP cat.5, LAN T11).
Section: electronic cassette - distributor CVR-1 should be made of UTP spiral cat.5 or telecommunication spiral (e.g. YTKSY).
Section between distributor and monitors should be made using spiral UTP cat.5. In case of CVR-1 plugs RJ45 should be installed on wire ends at the distributors (according to the instruction).
Total length of a segment electronic cassette – distributor + distributor – monitor should not exceed 150m.
Attention should be paid to appropriate matching of cables pairs. In the dia­gram, any pair of cables is marked with lines (thick and thin ones), which are situated close one to each other.
17
6.3 Wiring system of entry phone in video version 6 INSTALLATION AND ACTIVATION
It is recommended to complete wiring with the application of distributors CVR-2. Signals from the exchange are supplied to the distributors, which are then sent to the monitors. It is possible to connect up to four monitors to one distributor.
It is not admissible to make branchings by connection of two sections of cable (in order to distribute signal by branchings, signal distributor CVR-x should be used - see the next point). In parallel connection of receivers, cable should be conducted from one receiver (monitor, distributor, commutator) to the other. The principle should be also observed that signal comes to the receiver on one cable and goes out by the other. Both cables are connected on clamps of the receiver.
In entry phones with many occupants a wiring system should be made in form of a branch. In one branch up to 10 receivers (monitors or distributors) can be connected. The next branch can be made by treating one of the outputs from any distributor as a beginning of a branch.
An attention should be paid to the adjustment of wire wave impedance to the impedance of the connected equipment. In equipment installed at the beginning and at the end of the line a resistor should be installed in parallel to the line of value equal to cable wave impedance. In other equipment connected to the line no load resistors should be installed. Load resistance in external panel, monitors, distributors and switches is set by jumpers.
Mixed systems, in which uniphones and monitors are used at the same time, are allowed.
CVR-2
8
8
CVR-1
8
8
CVR-1
8
EC-3100
2
230V
2
230V
2
230V
2
230V
Figure 7: Method of connecting monitors to electronic cassette
EC-3100
230 VAC
4
branch 1 branch 2 branch 3 branch 4
CVR-x
Figure 8: Method of signal distribution within video installation
18
6.4 Installation of external panel 6 INSTALLATION AND ACTIVATION
6.4 Installation of external panel
NOTE!
In CD-3100 system each external panel connected to the same electronic cassette must have a unique physical number set up by jumpers on junction J1 (see dwg.
9). This number should be set up before installation the external panel. In external panel number 1,2,3 or 4 should be set up. Numbers 5 and 6 are reserved for service only and shouldn‘t be set up in normal mode.
Mounting under the plaster. In the wall cut out an opening of the dimensions that would enable to place the external panel freely in it and the frame should com­pletely cover the opening edges. Then 4 holes 10 should be drilled for strut pins. The tightening force (important when the cut out opening is deeper than cassette depth) should be matched to avoid bending of a frame. Make electrical connections and fix panel with a keyboard by two M4 screws and two rivets (included in the set). If possible the external panel should be mounted inside wind shields; the panel is better protected against weather conditions. Keyboard soiling (snow, mud) may re­sult in its defective operation – in such cases the dirt should b e immediately cleaned.
Mounting on the plaster. Drill openings for mounting the panel casing (mounted on the plaster), place the frame (or frames) in the casing mounted under the plaster and screw both elements by strut pins. Connect the wires and fix the panel with keyboard by screws and rivets. Set correctly contact JP1 in symmetrizator plate (see dwg. 9). Value of selected resistance should correspond to wave impedance of used wire or cable. Standard setting value 100 corresponds to the impedance of UTP spiral and telephone cables (e.g. YTKSY dia. 0,5) During the assembly of panels proper ventilation of sub-assemblies should ensured. That is why sealing (with silicone, foam, etc.) of space between frame and panel is not recommended.
J1
1 2 3 4 5 6
J
Z
P2
P1
J
- +
Input impedance 136
Input impedance 124
Input impedance 100
Symmetrizator plate
Figure 9: External panel - setting up of the physical number and adjusting elements
Installation of a panel with the list of occupants Panel with the list of occu­pants CP-3100N cannot be equipped with video camera so it is not used in entry phones in video version. When installing a cassette with a list of occupants one must remember to place a description prior to placing the rivets. The description should be made on a piece of paper of dimensions 51 x 90 mm. It is best to make a print on A4 sheet of paper
19
6.5 Installation of electronic cassette and power supply adaptor 6 INSTALLATION AND ACTIVATION
and then it should be cut to get the required size. 4 mm margin should be left at each edge of the sheet. Print should be made on a white sheet of paper of basis weight approx. 100 g/m2 using a laser printer. Ink printer should not be used for this purpose because the print may be smeared due to moisture. That is why it is recommended to laminate the sheet with a printed list. Any graphic program may be used for making the print e.g. Corel Draw or Photoshop.
In video version lists of occupants are not available.
Dents on the frame left side should be put in the openings in a casing panel. The frame should be pushed so that screws are inserted in frame openings
Move the frame as shown on the drawing and tighten the screws
Place a sheet of paper with a description between the plates and put them back in a panel remembering that thin plate should be placed at the casing back side
Loosen the mounting screws and move the frame towards the outside edge of a panel
Remove the frame by lifting it slightly and then moving towards the outside edge of a panel
Remove plexi glass plates
Figure 10: Replacement of a sheet with a list of occupants in panel CP-3100N
6.5 Installation of electronic cassette and power supply adaptor
Electronic cassette and power supply adaptor should be mounted inside the build­ing, most preferably in a place which is not accessible for unauthorized persons. It is recommended to place both devices in an installation box, the cassette is mounted by means of 4 screws or on a rail DIN. To the place where the p ower supply adapter is mounted supply from power network should be routed. Electronic cassette casing is fixed to the base by means of two screws. Removal of cassette casing requires disassembly of the whole cassette, because screws mount­ing the casing are placed at the back of the plate. Wire ends from feeding transformer should be wound on the smaller ferrite core included in the set. Each wire should b e wound 2.5 coils as shown on drawing 11. Wire connecting the MRL-1 module with electronic cassette should be wound simi­larly - at the side of electronic cassette the wire end should be wound on the bigger core. If this is impossible due to the thickness of wire, insulation should be removed and only those wires which are used for connection should be wound on the core. Connect the wires according to connection diagram. If on the display appears mes­sage [E-2] this means that there is a wire short circuit in entry phone line. Entry
20
6.6 Assembly of MRL-1 modules 6 INSTALLATION AND ACTIVATION
Core
Figure 11: Installation of ferrite core on cables
phone CD-3100 is resistant to such short circuit, however, it should be repaired as soon as possible. Electronic cassette is preliminarily adjusted and, unless it is necessary, the position of control elements should not be changed. In case of need the entry phone should be adjusted after the activation of all uni­phones. Then an installation procedure should be started P-3 (see p. 33) and an installation and activation should be carried out.
6.6 Assembly of MRL-1 modules
Module MRL-1 is used for connection of more than one panel to one electronic cassette. Module is used for electronic cassettes operating both main and slave entrances. Module should be mounted as close as possible to the electronic cassette. In order to mount MRL-1 module, four screws fixing a cover of casing to its base should be undone. After removal of cover, holes for fixing screws should be done in the base. Then it should be placed on the wall and holes for dowels should be marked. Drill holes in the wall, insert plastic elements of dowels in the holes and fix the base on the wall with screws. Then connect cables in accordance with connection scheme and screw down the cover. Module MRL-1 do es not require feeding or any configuration or adjustment.
6.7 Assembly of CVP-2 commutator
Commutator should be mounted in the installation box or in the wall inside the building, preferably in the installation box together with electronic cassette and MRL-1 module. To this end, four screws fixing a cover of casing to its base should be undone. After removal of cover, holes for fixing screws (W1, W2 - Fig. 12) should be done in the base. Holes in the wall for dowels should be made and the base should be fixed to the wall with screws. Then cables should be connected to clamps ARK in the commutator; plugs in this places of casing cover where cables will be inserted should be removed by means of pliers and then screw down the cover to the base.
Output C4+, C4- in the commutator operating at the slave entrance is reserved for the signal coming from the main entrance.
In order to receive an image, which is free from any deformation, a wiring sys­tem should be conducted in a proper way as well as input and output impedance of the installed equipment (monitors, distributors, commutators) should be adjusted to impedance of the cable used. Load on C1 input should be set on only one from
21
6.8 Installation of distributor CVR–1 and CVR–2 6 INSTALLATION AND ACTIVATION
among commutators - the one which is mounted on the end of the line (this should be done by means of the junction JP1). In case of the remaining commutators - all jumpers should be removed from the above mentioned junction. Load on C2 input should be set on each commutator (the junction JP2). Loads on X and Y outputs should be set on each commutator (the junctions JP6 and JP7). Load values for inputs and outputs should be matched accordingly to the type of connection cable. For the recommended UTP spiral - it is 100. For other cables, when released for the application, loads should be fixed to a value being equal to the impedance of the cable (see Fig.12, page 22).
Input impedance on C1...C4 inputs (JP1, JP2, JP4, JP5)
Output impedance on X output
Output impedance on Y output
CSA
JP1
JP2
JP4
JP5
JP6
JP7
JP3
X Y
C1 C2
V+ G - + - +
-+ -+
W1
W2
LML+L-
C3 C4
- -+
136 124 100
Signal correction (junction JP3)
Gain (junction JP3)
Off +2 dB+4 dB
136 100124
100 136124
On Off
Figure 12: Configuration of CVP-2 commutator
6.8 Installation of distributor CVR–1 and CVR–2
Floor distributors CRV-x should be installed in staircases in which video entry phone is installed. Distributor is fastened to the wall by two screws. Four screws should be driven to mount the casing cover to its base. After taking off the cover, make openings in the base for mounting screws (W1, W2 - dwg. 13), apply it to the wall and mark the places for strut pins. Drill openings in the wall, put plastic elements of strut pins in them and screw the base tot the wall. Then connect wires L+, L- and C+, C - to terminals ARK. Wire should be routed from one distributor to the next one. It is forbidden to connect distributors (or their parts) with electronic cassette by separate wires.
Apply for CVR-1
On the ends of wires from monitors converging at the distributor clamp the plugs RJ 45 paying special attention to correct order of wires in the plug. (see dwg. 14). Plugs should be put into distributor sockets. Distributor does not require individual power supply adaptor – it is supplied from any monitor which is connected with them - terminals VC and GND.
22
6.8 Installation of distributor CVR–1 and CVR–2 6 INSTALLATION AND ACTIVATION
Apply for CVR-2
Distributor require 15V DC stab./4A external power supply adaptor which allowed to load each of 4 outputs by the current of 1A to supply monitors (+15V, GND). It is not recommended to use with MV645x series monitors. It is recommended that wires sections connecting distributor with monitor connected to sockets MON1 and MON2 have comparable length. The same principle refers to wires connected to sockets MON3 and MON4.
To ensure wave adjustment, which is the main condition of getting clear and free of interference picture, at the end of this line load in form of resistor should be connected of value equal to the impedance the wire used in this line. In distrib­utors there are joints with jumpers allowing the connection of resistor of selected value (100, 124 lub 136 ). between terminals C+, C-. This resistance should be switched only in one distributor which was installed at the end of line C+,C-. If distortion is visible on the screen or the picture is not clear or pale amplifying and signal correction should be switched on. For MON1 and MON2 outputs correction and amplification are switched by jumpers in joint J2, while for output MON3 and MON4 – by jumpers in joint J3.
JP1
JP2
JP3
MON1
MON2
MON3
MON4
W1
W2
JP1
JP2
JP3
MON
1
MON
2
MON
3
MON
4
G
+
W1
W2
JP2 JP3
Band correction
Without band correction
JP1
Input impedance 136
Input impedance 124
Input impedance 100
Gain 0 dB
Gain +4 dB
Gain +2 dB
CVR-1
CVR-2
Figure 13: Configuration of distributor CVR-x
Plug in accordance with EIA/TIA 568B standard
nr clamp color
1 T + orange-white 2 T - orange 3 Vc green-white 4 L + blue 5 L - blue-white 6 GND green 7 C + brown-white 8 C - brown
uniwersal output uniwersal output power supply: +10VDC
uniphone line ground video signal video signal
function
uniphone line
8
1
Plug
1 8
Figure 14: Joint MON-1 of distributor CVR-1
23
6.9 Installation of monitor and additional cameras 6 INSTALLATION AND ACTIVATION
6.9 Installation of monitor and additional cameras
Installation and connection of monitors and additional cameras should be made on the basis of instruction enclosed to models that were used.
6.10 Installation and programming of uniphone
We assume that for each apartment a uniphone connection wire is routed, this wire is connected to terminals L+, L- of the exchange and the line is not shorted. Prior to installation of a uniphone its cover should be removed. Uniphone base should be fixed to the wall with strut pins 6 mm using openings in the uniphone base. Next uniphone number should be programmed. It is allowed to program at the most two uniphones (or monitors) with the same number. Programming is done by proper configuration of jumpers in joint inside uniphones. In uniphone physical number is programmed. Each number from a range 1...255 can be presented as a sum of numbers 1, 2, 4, 8, 16, 32, 64, 128. If a digit is included in the sum of the programmed number then we put a jumper in a position which corresponds to it, otherwise jumper should be removed (see dwg. 15).
Number ”0” should not be programmed (removal of all jumpers)!
On uniphone plate are marked digits assigned to consecutive positions on the joint. Example: in order to program number 37, jumpers should be put on interfaces in positions 1, 4, 32 (1+ 4 + 32 = 37). Then wires should be connected to uniphone terminals paying attention to their appropriate polarization and the uniphone casing should be closed. Uniphone is ready for operation and it can be checked using procedure P-3.
a)
37 = 1 + 4 + 32
1 2 4 8 16 32 64 128 1 2 4 8 16 32 64 128
b)
Figure 15: View of interface used for programming uniphone and example illustrating program­ming of uniphone to number 37.
Assembly and installation of non-standard uniphones, performing additional func­tions, such as LM-8W/4 or LG-8 should be carried out in accordance with a manual attachable to such equipment.
6.11 Adjustment of the doorphone system CD-3100
Initial adjustment of the doorphone is completed already during the production process. In some cases it could be necessary to make adjustments with the purp ose to adjust parameters to real working conditions taking into consideration noise levels in places, where the outer panel will be installed, or requirements of its users.
The doorphone is provided with the following potentiometers:
potentiometer P1 in the panel used to adjust signal amplification in loudspeaker of the panel.
24
6.11 Adjustment of the doorphone system CD-3100 6 INSTALLATION AND ACTIVATION
J
Z
P2
P1
J
J1
- +
Kaseta elektroniki
DATA:
ul. Nowa 20, 90-031 £ód, tel. (0-42) 672 44 00, fax 672 44 45, e-mail: laskomex@laskomex.com.pl,
http://www.laskomex.com.pl
AC1
AC2GPVP
AC3
AC4
GZA
VZAKZVZGZJ3-B+B
GS
VS
14 V AC
0.8 A
+7V
0.5A 12 V AC
1 A
+13V
0.8A
+12V
L-
L+K6K5K4K3K2K1
PR/CS
BALANSMIKROFON G£ONIKRESET
CP-2500
A/B
b)a)
BALANCE
- +
P3
- +
Figure 16: Adjusting elements of the doorphone
potentiometer P2 in the panel used to adjust signal amplification in microphone built in the panel. Position of this potentiometer along with the position of potentiometer P3 in the electronic cassette decides about volume intensity in receiver of uniphone.
potentiometer P3 in electronic cassette (balance adjustment) used to set up optimal conditions for uniphones line.
potentiometer P1 in the uniphone to adjust amplification of the local micro­phone amplifier.
In the case when to one electronic cassette several panels are connected, balance adjustment is performed only once using to this end one of the panels, whereas for the others adjustment of volume and microphone amplification (P1 and P2) is made when necessary. Such adjustment should be performed individually for each slave electronic cassette. In the case of the system with the main entrance, at first adjustments in all slave cassettes of the system should be made. Next, the main cassette should be connected and adjustments should be performed in the same way, like in case of balance adjustment for uniphones line (considering slave electronic cassettes as uniphones). Sequence of operations during adjustment of line balance is as follows:
Establish connection with any apartment
Set up potentiometers P1 and P2 in positions ensuring optimal audibility in the panel
Making adjustments by means of potentiometer P1 or P2 (in description it has been assumed that adjustment is made by means of P1), obtain small acoustic feedback. The system should be adjusted in such a way that it would remain within the limits of acoustic feedback appearance - this will make possible to adjust precisely balance of potentiometer P3.
Making adjustments by means of balance potentiometer P3 in the electronic cassette in one direction, find point, in which excitation of cassette is noticed; next - find the second such point performing adjustments in the opposite di­rection. If these points are situated far away from each other, adjustment with the application of potentiometer P1 must be carried out once again.
Set up balance potentiometer P3 in the central p osition, between the found points of excitation.
25
6.12 Activation 6 INSTALLATION AND ACTIVATION
Set up the potentiometer P1 in a position, ensuring optimal acoustic conditions.
It is recommended to check all installed uniphones. In case, when in any of them acoustic feedback appears, it should be eliminated by adjusting potentiometer of microphone amplification in the uniphone. In case, when more such uniphones have been found, correction of potentiometers P1 and P2 positions should be introduced.
6.12 Activation
The entry phone was designed in such a way as to enable its activation by one person. After performing entry phone electrical system as well as activating and configuring the electronic cassette assembly and activation of uniphones and mon­itors can be started. At this stage activation of installation procedure is required. In order to start installation procedure the following activities should be done:
start programming mode and select procedure No. 3 - see item 7.4, 33.
set upper and lower range of scanned numbers P-3-1, P-3-2 (option). Owing to this time required for finding of pick up receiver will be shortened
start installation procedure (P-3-0).
exit programming mode (e.g. P-8).
On display message U lub LOC will appear informing about installation proce­dure. Message U informs that installation procedure operates and occupants can use the entry phone. Message LOC informs that there is no possibility of entry
phone use. Install uniphone or monitor in the apartment and connect wires of electric system to it. Line L+, L- is protected against short-circuit, however short-circuits of wires, especially those which supply monitor should be avoided. Then the uniphone receiver in an apartment should be picked up and electro-catch opening pushbutton should be pressed.
NOTE!
During this operation the receiver should not be kept close to an ear because loud sounds may be heard!
Electronic cassette will start to search the signal with picked up receiver, after it has been found a short signal will be heard in the receiver and the connection will be set with the external panel. Next step is programming of calling signal. This operation can be ignored by re­placing the receiver. In entry phone 8 different calling signals are available which may be individually programmed in each apartment. Calling signal is changed by pressing electro-catch button in the uniphone. An installing specialist may change calling volume by pressing a lever under the receiver for a moment (approx. 0.5 s), in the receiver calling signal may be heard. Next pressing will result in next calling signal of different volume. Three short
26
7 PROGRAMMING OF ENTRY PHONE
signals of increasing frequency in a receiver mean that calling signal if increasing frequency has been selected. After having made the selection of calling volume and tone the receiver should be replaced to accept changes. After hang up the uniphone, the system will call back and the installing specialist can check correctness of the acoustic line and electro­catch.
NOTE!
It is recommended to activate entry phones in apartments in order from the highest to the lowest numbers especially if the apartments are occupied. After the installing specialist has left, the occupants themselves can start installation procedure, in such situation the exchange will find and connect the uniphone of lower number.
7 Programming of entry phone
In entry phone control program 9 procedures are available in which parameters effecting the operation of the whole system can be changed. In order to change cassette settings, it should be brought to programming mode. For this purpose, field marked with symbol of key should be touched five times. When four horizontal lines appear on display serial number of electronic cassette should be entered. The code can be read from a label placed on cassette bottom, on the exchange processor or sheet with the codes of the combination lock. If administrator key has been defined earlier, key can be applied to the reader instead of entering the code.
ENTER SUCCESSIVELY 4 DIGITS OF CODE
1 2 3 4
OR
Figure 17: Entering programming mode
If installing specialist‘s code (serial number of electronic cassette) is correct or administrator‘s key was applied to the reader symbol P- . will appear on the display
which will inform that entry phone in the main menu of programming mode. In programming mo de 9 procedures are available in which values of consecutive parameters can be edited. In procedures P1 and P2 switching to next parameters is realized by means of pushbuttons 1, 4, 7 (scroll backward) and 3, 6, 9 (scroll forward).
Edition of parameter value takes place after selecting key with symbol KEY . In edition mode flashing current parameter value appears on the display. This value can be changed by selecting a new value by the keyboard or deleting it by key [C] and entering a new value. The role of function keys in programming mode is presented on the following drawing.
Function key KEY is used for switching to parameter edition mode and accepting entered values. Using key KEY it is possible to return to main menu level (there
27
7.1 P-0 Entering PIN code of external panel 7 PROGRAMMING OF ENTRY PHONE
sCROLL RIGHT
SCROLL LEFT
EDITION /
APPROVAL
CANCEL
Figure 18: Function keys in programming mode
is message P- . on the display). To exit the programming mode, it is necessary to go back to the main menu [P- .] and use key [C]. Procedures available in en­try phone programming mode are described below. Message displayed on external panel during the edition of given parameter is marked with bold type, allowable values of parameters are given in frames, default value of parameter is given in square brackets, while operation modes of electronic cassette, in which edition of a parameter is possible electronic is given in round brackets.
7.1 P-0 Entering PIN code of external panel
PHYSICAL
NUMBER
OF PANEL
SERIAL
NUMBER
OF PANEL
PREVIOUS
PIN CODE
NEW PIN
CODE
0 1 2 3 41 C
Panels of doorphone systems CD-3100 are protected against theft by means of PIN codes. In order to use the panel, the PIN code supplied along with the panel by company Laskomex should be introduced only once. This operation should be also accomplished after each replacement of electronic cassette or after changing of physical number in the outer panel.
Start procedure P-0. On the display, a message CP-x will appear for the moment, where x- physical number of the panel being currently used, and then
CP-
Indicate physical number of the panel, for which PIN code should be entered. On the display, four-digit serial number of the panel will appear.
Find the brochure, attached to the panel and containing the serial number corresponding to the number, read off from the panel. Read off the PIN code.
Press key button C . Four-digit number (actual PIN code) will appear on the display. Delete previous code with key button C , enter PIN code read off from the sheet of paper and confirm it with key button KEY .
28
7.2 P-1 Operation parameters of entry phone 7 PROGRAMMING OF ENTRY PHONE
Repeat this operation for remaining panels. Finish entering PIN codes with a key button KEY .
7.2 P-1 Operation parameters of entry phone
PARAM.
No 1
EDITION-
OLD VALUE
1 3
PARAM.
No 2
1 2
EDITION-
NEW VALUE
CHANGE
ACCEPTATION RETURN
C
EtyP 0,1 [0] (U,H)
Operation mode of electronic cassette
Electronic cassette may service the main entrance (e.g..entrance in fence) or subor­dinate entrance. In default setting electronic cassette operates subordinate entrance e.g. entrance to staircase - operation in U mode (parameter value equal to 0). Set­ting parameter value to 1 makes that electronic cassette operates the main entrance (operation in H mode). The change of operation mode of electronic cassette (e.g. which earlier operated in H mode) results in the loss of some information including recorded in memory numbers of electronic. That‘s why this function should b e used carefully. After the change of cassette type the operation of restoring default settings and erasing the electronic‘s key memory should be made (see page 47).
tOc 10...255 [30] (U,H)
Waiting time for picking up the receiver in seconds.
Parameter defines waiting time for receiver pick up in seconds after finishing of calling.
tro 10...255 [120] (U,H)
Time of conversation.
Conversation time after picking up the receiver is limited. 10 s before the lapse of conversation programmed time sound signals will be heard in the receiver, which will inform about approaching time of breaking.
Calling tone
t1d- signal generation
t1t t1t t1t
tpa - gap time
Figure 19: Structure of calling signal
Calling signal consists of three tones of different frequency (F0, F1 i F2) gener­ated in turn for some time (t1d - see dwg. 19), after that there is a break (tPA)
29
7.2 P-1 Operation parameters of entry phone 7 PROGRAMMING OF ENTRY PHONE
- these make the complete calling cycle. Any proportions may be set between the signal generating time and the following break; furthermore time of an individual tone (t1t) as well as tone frequencies F1 and F2 may be changed as well. Owing to this a uniphone calling sound may be changed in a wide range.
t1t 2...20 [5] (U,H)
Time of individual tone generation PS.
Duration of an individual tone in ms (parameter value x 10 ms).
t1d 10...255 [100] (U,H)
Time of signal generation PD.
Duration of a signal consisting of tones repeated in cycles F1,F2,F3 expressed in ms (parameter value x 10 ms).
tPA 20...255 [150] (U,H)
Pause time PA.
Break after signal generation in ms (parameter value x 10ms).
F1 50...255 [125] (U,H)
Signal frequency F1 in Hz (parameter value x 10 Hz).
F2 50...255 [175] (U,H)
Signal frequency F2 in Hz (parameter value x 10 Hz).
Electro-catch trY 1...31 [5] (U,H)
Time of electro-catch operation.
Kind of numbering
nbl 0...9998 [0] (U)
Block number.
Value above 0 is set in electronic cassette servicing subordinate entrance switches on mode with building numbering. This mode will operate properly if in electronic cas­sette, which services the main entrance, mo de with building numbering is switched. Details in item ”Numbering”, see page 10.
Pnu 0...9998 [0] (U)
Range shift.
Parameter used in numbering mode with range shift. Details in item ”Numbering”, see page 10.
LPi 0...100 [0] (U)
Amount of rooms on the floor.
Parameter used in hotel numbering mode in which room number is preceded by a digit which defines the floor on which the room is located. Details in item ”Num­bering”, see page 10.
30
7.2 P-1 Operation parameters of entry phone 7 PROGRAMMING OF ENTRY PHONE
LLo 1...250 [1] (U)
Range of serviced numbers – low value.
Parameter is used to set number range which is serviced by an entry phone. After selecting a number outside this range a message will appear on the display OFF .
Limiting the range is recommended especially in case of an entry phone in a multi­entrance version. Be careful that LLo < LHi . otherwise selecting of any number will result in displaying a message OFF
LHi 1...250 [250] (U)
Range of serviced numbers – high value.
Parameter is used to set number range which is serviced by an entry phone. After selecting a number outside this range a message will appear on the display OFF . Be careful that LLo < LHi .
LdP 0...9998 [0] (U)
Directing of not serviced numbers
All numbers which are not serviced by entry phone CD-3100, will be directed to uniphone number given as LdP value (see item 4 page 10).
Ld1 0...9998 [0] (U)
Additional number not included in the serviced range.
Additional number not included in the serviced range. Number introduced as a value of this parameter will be assigned as a logical number of uniphone of physical number 251.
Ld2 0...9998 [0] (U)
Additional number not included in the serviced range.
Additional number not included in the serviced range. Number introduced as a value of this parameter will be assigned as a logical number of uniphone of physical number 252.
Ld3 0...9998 [0] (U)
Additional number not included in the serviced range.
Additional number not included in the serviced range. Number introduced as a value of this parameter will be assigned as a logical number of uniphone of physical number 253.
Ld4 0...9998 [0] (U)
Additional number not included in the serviced range.
Additional number not included in the serviced range. Number introduced as a value of this parameter will be assigned as a logical number of uniphone of physical number 254.
31
7.3 P-2 Functions realized by entry phone 7 PROGRAMMING OF ENTRY PHONE
7.3 P-2 Functions realized by entry phone
Parameters P2 can have values [-0-] or [-1-]. In square brackets default value of parameter is given. Value [-1-] means switched on function, value [-0-] - switched off function.
2 3 1 2 C
PARAM.
No 1
EDITION-
OLD VALUE
PARAM.
No 2
EDITION-
NEW VALUE
CHANGE
ACCEPTATION RETURN
EnAu 1 (U,H)
Sound signal of sign selected from the keyboard
Selection of any sign from the keyboard may be signaled with short acoustic signals
tonY 1 (U,H)
Multitone signalling of sign selected from the keyboard
Selection of a key may be signalled with the same sound (one tone signalling) or for every key sound of different pitch may be attributed (multitone signalling). The use of this function requires fulfilling the following condition EnAu=1 and tonY=1.
CoEn 1 (U,H)
Switching on coded lock service
Setting 0 value makes that function of coded lock will be switched off for all users regardless of setting for the individual apartments.
CoEd 1 (U)
Permission to edition of coded lock codes by occupants.
By default the occupants have the possibility to change the co des of a combination lock in user‘s menu. Setting this parameter to value ”0” blocks this possibility to all occupants regardless of individual settings.
CoPo 1 (U)
Permission to confirm the use of lock code.
Each unblocking of door by means of a coded lock makes that three short acoustic signals are generated in a uniphone mounted in an apartment whose code was used to open the door. Parameter set to ”0” enables to switch off this signalization in all uniphones. The signaling can be switched off for the selected numbers (see procedure 7.6, page 38).
CoEr 1 (U)
Confirming the use of a wrong code of coded lock.
Entering the wrong code to a combination lock makes that two long acoustic signals will be generated in a uniphone mounted in an apartment to which there was an attempt to use a code to open the door. This is a signal for occupants that some­body tries to break the co de of a combination lock. This option allows switching off this signalization in all uniphones.
32
7.4 P-3 Installation procedure 7 PROGRAMMING OF ENTRY PHONE
ibEn 1 (U,H)
Switching on/off of electronic keys
Setting parameter value to ”1” permits using electronic keys iButton (Dallas).
ibAd 1 (U,H)
Registration of electronic keys by users
Setting parameter value to ”1” permits the users to register new electronic keys from user‘s menu.
5Ybr 1 (U)
Signaling number of the gate, from which a call has been received
When a call from slave entrance is being received, the doorphone may signal acous­tically entrance number, from which such a call is coming from. The number is signaled with a short acoustic signal after each calling cycle.
Ent 1 (U)
Fast entrance
In order to enter an apartment in a building with the main entrance two entrances protected by entry phone system should be passed. An occupant must activate electro-switch twice - the first time at the main entrance and the second time at the subordinate entrance (see page. 43).
nrbl 1 (H)
Mode with building numbering
Switches on the mode with the building numbering. The function will operate properly if parameter nbl in U exchanges is above zero.
7.4 P-3 Installation procedure
3
SWITCH ON THE INSTALLATION PROCEDURE
0 C
The procedure facilitates the activation of an entry phone system. Starting pro­cedure P3 enables the installing specialist to check the correctness of functioning of uniphones mounted in apartments without any help of other persons. Activation of CD-3100 was described in chapter 6.12, on page 26.
P-3-0 ON/OFF - switching on/switching off of installation procedure P-3-1 LLO - low range of searched numbers P-3-2 LHi - high range of searched numbers
P-3-3 Searching for the picked up (incorrectly placed) receiver. When this pro-
cedure is started, searching for picked up (incorrectly placed) receivers begins. On the display numbers of successively checked apartments are being indicated. When uniphone with the picked up (incorrectly placed) receiver is found in one of such
33
7.5 P-4 Electronic keys 7 PROGRAMMING OF ENTRY PHONE
apartments, then the display of the external panel will show the number of such uniphone for a couple of seconds. In order to start searching for next uniphones, a key with a KEY symbol should be pushed or one must wait a couple of seconds. After that searching will be started automatically.
P-3-4 LOC/OFF Blocking the possibility of using an entry phone. In this mode it is not possible to get connection with any apartment, however, entering any number from a keyboard of an entry phone will result in unblocking the entrance. This function can be used during the activation of an entry phone and enables the occupants to enter the staircase with a door equipped with self closing device.
P-3-5 L-F Calculator converting uniphone logical number to its physical num- ber. Calculator functions on condition that range shift parameter has been set or the exchange has been set to hotel numbering mode. In order to calculate the phys­ical number of a uniphone, its logical number should be entered from a keyboard and then it should be confirmed by a key with a symbol of key.
P-3-6 F-L Calculator converting the physical number to logical number. The principle of operation is similar to procedure P-3-5. In order to calculate the logical number of a uniphone, its physical number should be entered from a keyboard and then it should be confirmed by a key with a symbol of key.
P-3-7 SYSt Restoring the default parameters of the exchange operation (defined by procedures P-1 and P-2).
P-3-8 CodL Restoring the default parameters of the values of the coded lock. Restoring the codes of a combination lock results in restoring the default code of an installing specialist.
P-3-9 OPoL Restoring the default values of individual settings in electronic cas- sette.
7.5 P-4 Electronic keys
Entry phone CD-3100 can be equipped with electronic key reader. There are three kinds of keys in entry phone. Service keys enable change of entry phone con­figuration, special keys are used by postmen, administration etc. and keys for the occupants. Keys should be registered at both the main and subordinate entrance. At the main entrance keys attributed to apartment cannot be registered. Entry phone users can register their own electronic keys (see page. 45). This pos­sibility can be switched off globally in procedure P-2 by setting parameter [ibAd] to value ”0” or individually in procedure P-5. Electronic keys can be used after their earlier registration in entry phone memory. Registration includes the activation of procedure (P-4-1 or P-4-2) and applying the key to the reader.
34
7.5 P-4 Electronic keys 7 PROGRAMMING OF ENTRY PHONE
P-4-0 C 0 (U,H) Resetting electronic key memory.
Procedure is used for resetting all keys stored in entry phone system memory.
4
0
1 2 3 4
Installing
specialist`s
code
Administrator code should be given to protect against accidental resetting. After having given the code or having used the service key during resetting time on display
message CLR and tst will appear. Procedure results in resetting of all user‘s code and service key codes which lasts approx. 5 sec.
P-4-1 Add (U,H) Addition of key without attributing to apartment.
After applying the key to the reader its serial number will be read and stored in
4
C
1
CELL
NUMBER
IN MEMORY
entry phone memory. On the display the following messages will be shown Add ,
NEU and xx ,where xx is a number which defines number of memory cell in which
key number was saved. If the key has already been saved in entry phone memory a message OLD will appear on the display. An installing specialists cannot change
the item in which key number is saved. The key is registered in the next free mem­ory item. An installing specialist can make a list in which key position in memory as well as the name of a person to which the key will be given. It is important in the case when the key has to be deleted from the memory, however this method is not comfortable.
P-4-2 L- - - (U) Addition of key with attributing to apartment
Procedure enables adding of key and attributing it to selected apartment number,
4
2 1 0
END OF OPERATION
APARTMENT
NUMBER
POSITION
IN MEMORY
which facilitates keys management. The use of the key is signalled in uniphone receiver as in the case of combination lock. Programming is realized as follows:
After activation P-4-2 on the display a flashing message will appear L- - - .
Give apartment number and confirm it with key KEY . Digit on the display will flash slowly.
35
7.5 P-4 Electronic keys 7 PROGRAMMING OF ENTRY PHONE
Apply key to the reader. On the display a message Add will appear for a moment and a number of memory item in which key number is saved.
When on the display a flashing apartment number reappears next key for this apartment can be registered.
Key KEY . should be used for registration of keys for next apartments. When message L- - - appears on the display the operation should be repeated.
P-4-3 AddP (U) Programming of key on the selected item in memory.
Key can be programmed in the selected item in key memory. Function is used
4
3
APARTMENT
NUMBER
1 5
for registering next special keys, because memory cells in which the keys are saved are protected against recording in other way. To reset special key or service key procedure P-4-6 should be used. Key organization in memory is as follows:
Operation mode EC-3100/U EC-3100/H
Regular keys 0-999 0-1999 Special keys 1000-1019 2000-2039 Administrator‘s keys 1020-1023 2040-2047
Registration of keys is as follows:
Start procedure P-4-3. On the display message AddP will appear and after a while P—
Give item number and confirm by KEY . Message will stop flashing.
Apply the key to reader. On the display message Add . will appear.
Repeat the operations for the following keys or finish it with KEY key
P-4-4 dEL (U) Key resetting.
Deleting the key from memory will take place after applying it to the reader. On
4
4
APARTMENT
NUMBER
the display a message CAS will appear and a digit which defines the memory item
36
7.5 P-4 Electronic keys 7 PROGRAMMING OF ENTRY PHONE
in which the deleted key was recorded.
P-4-5 LdEl (U) Resetting the key attributed to the apartment.
4
5 6 3 C
CELL
NUMBER
IN MEMORY
APARTMENT
NUMBER
Key resetting procedures:
start program P-4-5. On the display message LdEl will appear.
Give the apartment number and confirm it with key KEY . Entry phone will search the first memory item in which key number attributed to the selected apartment is recorded
If the key has been located, on the display the following messages will appear successively P and xx where xx is a number which defines number of memory
cell in which key number was saved.
To reset the key select key C . On the display message CAS will appear for a moment. Entry phone will start searching next keys.
Use key KEY . to pass to the next item. If in the next few seconds none key is used, the entry phone will search automatically the next key attributed to the selected apartment number.
As soon as the whole base is searched message End will be displayed. End
P-4-6 PdEl (U) Resetting key recorded in the defined item.
Procedure is used for key resetting after having given the memory item in which
4
6
CELL
NUMBER
IN MEMORY
6 3
the key was recorded. After starting the procedure on the display a message P— will appear. After memory item is given and after confirming with key KEY the
key number will be deleted, which will be confirmed by message CAS . If given item is free on the display message FrEE will be shown.
P-4-7 Id (U) Key identification.
Procedure is used for key identification. After applying the key to the reader on the display an information will appear in which item it will be recorded P - x and to which apartment it is attributed: L - x , (if it is not attributed L - 0 ). If identified
37
7.6 P-5 Individual settings 7 PROGRAMMING OF ENTRY PHONE
4
7
CELL
NUMBER
IN MEMORY
APARTMENT
NUMBER
key is defined as serviced message SER will appear on the display.
P-4-9 SEr (U) Programming of service key (administrator).
Service key functions similarly to administrator‘s code it enables to enter pro-
4
9
gramming procedures and service key functions independently of administrator‘s code. This operation results in replacing the old key with a new one. In order to register next service keys one should use procedure P-4-3. Service keys are regis­tered in memory cells in the range 1020 ...1023 w EC-3100/U and 2040...2047 in EC-3100/H. Keys may be overtyped with other keys or delete from the definite memory cell with procedure P-4-6.
7.6 P-5 Individual settings
In system CD-3100 there is a possibility of individual settings of some parameters of entry phone connected with uniphone calling and functions of combination lock. Values of parameters 1-3 may be changed by occupants by user‘s menu (see page.
45), parameters 4-6 are available for the installing specialist only. Parameter values
5 1 2
Figure 20: Starting the program of individual settings for the selected apartment (in example No. 12)
are changed by means of keys 1 - 6. Each pressing of the selected button results in setting of next value of the parameter. Keys 7 and 9 are used for switching of the parameter edition mode – the previous and next apartment number.
4
7
9
Previous
apartment
Next
apartment
Calling tone
1
2
Calling volume
Number of bells
3
Options of combination lock
Calling options
6
5
Entrance service
Figure 21: Keys used for changing individual settings
38
7.6 P-5 Individual settings 7 PROGRAMMING OF ENTRY PHONE
Parameter No. 1. Calling tone, key 1
Parameter can take values from the range 0...7. Parameter value is defined by one of 8 pre-defined calling tones.
Parameter No. 2. Calling volume, key 2
Entry phone enables setting three volume levels and calling of increasinng volume (requires setting at least three bells)
G — loud bell
N — increasing bell
C — silent bell
U — moderate bell
Parameter nr. 3. Number of bells, key 3
Entry phone allows defining the number of bells which will be generated after calling. From 1 to 8 bells can be set.
Parameter No. 4. Calling options, key 4
If needed entry phone reaction after calling can be changed:
A — Active uniphone. Uniphone may be called, conversation can be conducted
and electro-catch may be controlled.
– — Uniphone switched off. Selection of this option makes that it is impossible
to make a connection with the apartment for which such setting was selected. An attempt to make a connection will be followed by a message OFF .
d — Uniphone functions as a bell. Uniphone may be called, however, conver-
sation cannot be conducted and electro-catch cannot be controlled.
Parameter No. 5. Entrance service, key 5
In the entry phone it is possible to define how the pushbutton operates the electro-catch at the individual entrances.
A — Pushbutton activates electro-catch at the main entrance and at the
subordinate entrance.
– — No electro-catch control from the uniphone (monitor).
U — Pushbutton activates electro-catch at the subordinate entrance only.
H — Pushbutton activates electro-catch at the main entrance only.
39
7.6 P-5 Individual settings 7 PROGRAMMING OF ENTRY PHONE
Parameter No. 6. Options of combination lock, key 6
This parameter defines the operation of combination lock.
E — Combination lock activated, occupant may change the code and register
electronic keys.
– — Combination lock switched off.
A — Combination lock activated, occupant can neither change the code or
register electronic keys.
Copying of settings Entry phone CD-3100 enables copying the selected set of settings to group of numbers which is defined by a number range from the lowest number (LLO) to the highest (LHI). The logical range of numbers should be given (taking into account number shifting or hotel numbering).
Copying of settings is realized as follows:
start procedure P5 and give ”0” as a number of apartment (see dwg. 22)
using keys 1-6 set, according to the above instruction, the desired combination of individual settings.
selected settings should be confirmed with a KEY symbol. On the display message [CPY] will appear for a moment and then horizontal bars (see dwg.
23).
give the code of an installing specialist. This a security against an accidental copying of settings.
give the lowest number from the number range to which the settings will be copied (LLO).
give the highest number of his range (LHI) and confirm with a key KEY
on the screen fast changing digits will appear informing about copying of set­tings.
5 0
Figure 22: Copying of settings - starting the procedure
Installing
specialist`s
code
1 2 3 4
1
Range
down
Range
up
Figure 23: Copying of settings - selection of number ranges
40
7.7 P-6 Change of installing specialist‘s code 7 PROGRAMMING OF ENTRY PHONE
7.7 P-6 Change of installing specialist‘s code
The code of an installing specialists enables entering the entry phone program­ming code. In case of installing specialists or property administrators it is convenient to use one common code for all entry phones which should be maintained. After having restored default settings of entry phone or codes of combination lock the manufacturer‘s value of the code is restored. To change the old code of an installing specialist, the old code should be given and a new one should be entered.
6
OLD
CODE
1 2 3 4
NEW
CODE
1 2 3 4
7.8 P-7 Electro-catch test
7
This procedure is used during installation and control of electro-catch or electro­magnetic lock. Every activation of procedure P-7 causes switching on the electro­catch for the set time and then return to the program main menu.
7.9 P-8 Release of electro-catch in service mode
8
This procedure enables the installing specialist to enter the staircase e.g. to service the installation. Owing to this he does not have to ask for opening the door by the occupants. Activation of this procedure makes that the door is unblocked and then the entry phone returns to normal operation mode. This procedure may also be used for quick quitting the programming mode.
7.10 P-9 Change of coded lock code
To change the code of coded lock the following activities are done:
Activate procedure P-9. When on the display of external panel a message ­appears number of apartment for which lock code will be changed should given.
When on the display symbol - - - - appears four digits of a new code should be entered.
After having entered the last digit on the display a symbol - will appear. The operation can be repeated for the next number or finished by using a key KEY
41
8 ENTRY PHONE USE
1 2 394
NEW CODE
8 Entry phone use
8.1 Connection with apartment
To make the connection with the apartment, its number should be entered from the keyboard. After the lapse of 3 s a uniphone in this apartment will ring and on
the panel display message CALL will appear. Then on the display message [OuO] will appear which will inform that entry phone waits for picking up the receiver. If the receiver in the apartment is picked up, this symbol changes to ouo and a conversation can be conducted. If the receiver in the apartment is not picked up then after several seconds the entry phone will return to normal operation mode. Time of conversation is limited and in standard setting it amounts 2 minutes, however, the installing specialist can change it. 10 seconds before the conversation is ended on the display digits will appear while in the uniphone receiver and panel loudspeaker short acoustic signals will be generated informing how many seconds are left till the conversation is ended. The conversation can be finished by hanging up the receiver. In any moment of the conversation the occupant may open the electro­catch by pushing the door opening button in uniphone or monitor. Electro-catch is activated in standard setting for 5 sec. Release of the entrance lock is signaled with acoustic signal from loudspeaker in external panel. In selected apartments an installing specialist may switch off the possibility of activating the electro-catch or limit it to the activation of electro-catch at the main or subordinate entrance. In entry phones with more than one entrance users may see a message ZAJ . This message means that a conversation is conducted at the other entrance and entry phone is busy at the moment. In such situation one must wait until the first
conversation is finished (message ZAJ will disappear and it will be possible to use keyboard). In entry phone with the main entrance a situation may take place when from the main entrance an attempt will be made to connect the number from which a conversation is being conducted with the subordinate entrance. In such situation this conversation will be shortened. Entry phone within 10 sec will automatically finish the conversation, at the same time on the display digits will appear which would inform how many seconds are left till the conversation is ended and in the uniphone receiver short acoustic signals will be generated.
8.2 Connection from the main entrance
Using the entry phone at the main entrance is the same as at the subordinate entrance. If building numbering mode is activated, the number selected from the keyboard consists of two elements: building number and apartment number in this building (or staircase).
42
8.3 Use of uniphone 8 ENTRY PHONE USE
Number selection in this mode is as follows:
Select the block number e.g. 8. On the display message b 8 appears
Confirm with key KEY . On the display message L will appear
Enter apartment number
Wait until entry phone rings and on the display message CALL appears.
Flashing message ZAJ visible on the display means that a conversation is conducted between the selected or other number in the same staircase from the subordinate entrance. This conversation will be broken after 10 sec; no action should be made, it is enough to wait until entry phone rings at the selected apartment which will
be signaled with message CALL Entry phone CD-3100 realizes functions ”fast en­trance” which is used only in entry phone with the main and subordinate entrances. In entry phone without this function one must ring the occupant twice in order to get to his apartment (the first time at the main entrance and the second time at the entrance to the staircase). Function ”fast entrance” eliminates the second step. The function is activated by an occupant in his apartment:
During the conversation with the person at the main entrance, the entrance should be unblocked by pressing the electro-catch pushbutton in uniphone or monitor. Then uniphone forks should be pressed for a while – activation of a function will be confirmed by three increasing sounds in the uniphone receiver.
The function can be switched off by pressing uniphone forks for the second time. Switching off the function will be confirmed by three decreasing sounds in the uniphone receiver.
Visiting person comes to the staircase and attempts to make a connection with the apartment by selecting its number from the keyboard. Entry phone instead of making the second connection with the apartment, releases door catch.
Function remains activated for 4 min and 15 sec from the moment of its acti­vation.
Each electronic cassette servicing staircase can activate option for two apart­ments at the same time.
For one apartment a function cannot be activated twice at the same time.
8.3 Use of uniphone
When holding a receiver close to an ear one should not press forks in the uniphone base for a longer time because a loud signal may be generated in the receiver, which can result in hearing defect. During the conversation the user can in any moment press the button activating the electro-catch. Activation of electro-catch does not break the conversation. Uniphone can be equipped with a key to control gate drive.
43
8.4 Monitor usage 8 ENTRY PHONE USE
This key can operate in two ways:
key operates only during the conversation
key operates in any moment
8.4 Monitor usage
After a call from the doorphone at the gate, a calling signal will be indicated in the monitor and, at the same time, the image from the camera situated at the entrance will appear on the screen. Using the monitor, conversation can be led with a simultaneous observation of a calling person on the screen and electro - catch at the entrance can be controlled. Digital doorphone CD-3100 co-operates with various models of monitors. Detailed instruction of connection, programming and operation differs depending on the model and is being attached individually to each monitor.
8.5 Using coded lock function
To each apartment one four digit number is attributed which is preliminarily defined in the entry phone production process. This code can be changed by an installing specialist or occupant (unless this option is blocked). Door opening with lock code is as follows:
Enter from the keyboard the number of apartment and confirm by a key KEY
Enter four digit code.
After having given the correct code the electro-catch will be released. In the uni­phone in an apartment whose code was used to open the door three short acoustic signals will be generated to inform the occupants that somebody has used their code. Each failed attempt to enter the code is signaled with two long signals in a uniphone receiver. Occupant can change the coded lock code that was given to him. Changing method is described below.
8.6 Using electric keys
To unblock the entrance with iButton (DALLAS) key it should be put to the reader in a video entry phone. Entry phone will read the key serial number and will compare it with the numbers in the memory. If the read number corresponds to one of the programmed numbers, the entry phone opens the electro-catch signaling the opening of door with four short sound signals. Occupant can add register next electronic keys (see next item of this instruction). The user can register keys only at the entrance leading to his apartment. Keys for the main entrance can be registered by an installing specialist only.
44
8.7 User‘s menu 8 ENTRY PHONE USE
8.7 User‘s menu
This menu is available in systems named 2502 or 3100. In order to check which system is present, the button [9] should be chosen four times on the panel key­board, after a moment on the panel display the system name and software version will appear.
Occupant can change from the entry phone keyboard (this refers to subordinate entrance) some operation parameters such as:
calling tone,
volume,
number of rings,
code of coded lock,
register new electronic keys.
To make changes an occupant must activate user’s menu. Some person in the apartment must help.
User‘s menu activation:
a) Make connection with the apartment (only from the subordinate entrance
panel).
b) Press button with a sign of a key and while pressing it ask a person in the
apartment to press the catch button five times. Activation of a function is signaled with three short signals in uniphone receiver and external panel and also with message [OPC] displayed temporarily on the external panel‘s
display. c) Finish the conversation. d) Enter the apartment number, press button with a sign of a key and enter
the code of coded lock. On the display user’s menu will be shown, where
parameter‘s edition is available. (see dwg. 24).
1
Number of bellsCalling tone
3
2
Calling volume
Figure 24: User‘s menu
45
8.7 User‘s menu 8 ENTRY PHONE USE
1 The first sign on the display defines calling tone (0...7). Calling signal can
be changed by pressing the key marked with number [1].
2 The second sign on the display defines volume of calling signal (G - loud,
N - increasing, C - soft, U - moderate). Selection of increasing signal is sensible at the number of rings higher than 1. Volume is controlled with key [2].
3 The third sign on the display defines the number of rings (1-8) - decides
how long the uniphone rings. Number of signals is controlled with key [3].
Change of coded lock code
To change the code of coded lock, user’s menu should be activated and key [0] should be selected. For a moment messages [NEU] and [CODE] and then four horizontal bars will appear and then new code of coded lock should be entered. New code should be entered twice. Option of changing the code by the user
can be blocked by an installing specialist!
Registering of a new electronic key
In user’s menu after selecting 8, message [ADD] will appear on the display. Elec­tronic key should be put to the reader. Message [NEU] means that key was recorded in memory and attributed to the apartment. If a key, which was recorded earlier is put to a reader, on the display message [OLD] will appear.
Exit from user‘s menu
To exit from edition of user’s menu (not to exit from the whole procedure) in order to check and to correct settings, press the key with a symbol of key [KEY]. There is a possibility to make a call. To finally exit from the whole procedure press the key [C]. In this case the second enter to the menu requires repeating the whole procedure from the beginning. After about 4 minutes of inactivity, access to the user‘s menu will be turn off au­tomatically.
In this procedure the necessity of cooperation with other person has b een intro­duced in order to prevent unauthorized changes of entry phone parameters.
46
9 RESTORING THE INITIAL SETTINGS
9 Restoring the initial settings
NOTE!
Restoring the default settings results in the loss of information recorded in memory EEPROM of electronic cassette (changed codes of coded lock, numbers of electronic keys, individual settings etc.). Prior to this operation one should get acquainted with the content of this chapter.
In system CD-3100 restoring of default operation parameters for electronic cas­sette can be done in two ways: globally (refers to parameters set by procedures P-1, P-2, P-5, P-6 and P-10) or selectively (default values defined by individual procedures are restored).
Global restoration of default parameters. Reset of electronic cassette.
In order to restore default parameters of electronic cassette operation pushbutton INIT (SW2) should be pressed and then a pushbutton RESET (SW1, see dwg. 25) should be pressed for a while and released. After approx. 2 seconds pushbutton INIT (SW2) can be released, at that time on the display of the external panel quickly changing digits will appear. When the countdown visible on the display stops, all default settings will be restored in the cassette: default codes of coded locks, code of installing specialist, exchange operation parameters defined in procedures P-1, P-2, P-3 and P-5.
NOTE!
It pushbutton INIT after having initiated remains pushed in for longer than 10s, electronic cassette will start resetting all recorded iButton keys.
Operation mode of electronic cassette will not be changed i.e. if before restoring default settings the cassette was configured as EC-3100/H, after finishing of this operation the cassette will still operate in this mode. Pushbutton RESET is used for momentary stopping the operation of a processor. Its pressing makes that the processor stops working, while the release causes the op­eration resumption; the processor starts the operation from the program beginning. The pushbutton is used in the case of exchange hang-up (it does not react to key selection and random signs appear on the display) and restoring default settings. Pressing pushbutton INIT is information for the processor that the default settings should be restored – video entry phone checks if this pushbutton was pressed just after switching on the supply or pressing and releasing of RESET pushbutton. That is why the sequence of operations is important during restoring the default values. Selective restoring of default settings of the entry phone system. Enables restoring the default values of the selected parameters without change of other parameters. This function is available for the installing specialist after entering the cassette pro­gramming mode and does not require the direct access to entry phone electronic cassette.
P-3-7 Restoration of operation parameters and configuration of electronic cas­sette. Restores default values of parameters in procedures P-1 and P-2.
P-3-8 Restores default values of co ded lock codes and preset code the installing specialist. If the code of the installing specialist was changed earlier it should
47
11 CONFORMITY WITH PREVIOUS VERSIONS
be remembered to change it again because quitting the programming mode will require entering the previous code. If the installing specialist has forgotten the previous code he can read it from a label on the cassette processor.
P-3-9 Restoring the default values of individual settings for apartments.
SW1
a)
P3
ZT4
X
NCNC
SW2
b)
AC1
AC2GPVP
AC3
AC4
GZA
VZAKZVZGZJ3-B+B
GS
VS
14 V AC
0.8 A
+7V
0.5A 12 V AC
1 A
+13V
0.8A
+12V
L-
L+K6K5K4K3K2K1
PR/CS
BALANSMIKROFON G£ONIKRESET
CP-2500
INIT
RESET
X
NC
NC
P3
Figure 25: Position of pushbuttons INIT and RESET
10 Maintenance of entry phone
In case the keyboard of entry phone gets dirty it should be wiped with a damp cloth. Surfaces through which lighting diodes are visible should be cleaned with special care. No visible dirt should b e left on it. This surface should not be cleaned with sharp objects which can scratch the plate.
External panels should be cleaned with means which do not contain solvents.
Uniphones should be cleaned with a damp cloth or using the means for cleaning plastics. It is forbidden to use solvents.
In case the monitor gets dirty it should be cleaned with a soft and damp cloth. It is recommended to do it with power cut off.
No abrasive materials which might scratch the casing surface can be used. No benzene, solvents or strong detergents can be used because they might cause damage or discolouring of the surface.
11 Conformity with previous versions
The doorphone CD-3100 is compatible with the doorphone CD-2502, e.g. for three main entrances CD-3100 can be used, whereas for slave entrances - CD-2502. Elements of the doorphone CD-3100 cannot be used instead of elements of other Digital doorphones produced by company Laskomex. The doorphone CD-3100 will also not operate properly with elements of doorphone systems CD-2000/CD-2500/ CD-3000.
48
13 TECHNICAL DATA
12 Messages about faults
The doorphone CD-3100 can signal the following faults:
EC: Means that two or more infrared beams are damaged or covered
E2: Means short-circuit of uniphone line. Installation should be checked, short­circuit should be eliminated or damaged uniphones should be replaced. By measuring current input on uniphone line, the nature of fault can be determined.
E0: This message means that system memory EEPROM is damaged in the electronic cassette.
EEr: Means an error in recording or in reading memory with system settings or codes of combination lock
13 Technical data
13.1 Degree of protection
Electronic cassette EC-3100: IP20 External panel CP-xxx: IP44 Uniphone (each model for CD-3100): IP30 Monitor (each model for CD-3100): IP30 CVR-1, CVP-1, CVR-2, MRL-1: IP30
13.2 Description of terminals
Electronic cassette
AC1 cassette supply 14,5V AC AC2 cassette supply 14,5V AC GP mass of non-stabilized voltage VP non-stabilized voltage output AC3 electro-catch supply 12V AC (for connecting transformer) AC4 electro-catch supply 12V AC (for connecting transformer) GZA mass of electro-catch supply 12V DC/0.8A VZA electro-catch supply 12V DC/0.8A GS’ mass of stabilized voltage VS’ stabilized voltage +12 V
49
13.2 Description of terminals 13 TECHNICAL DATA
CS cameras selection control VS stabilized voltage +12 V T digital transmission GS mass of stabilized voltage SP loudspeaker GA analogue mass MC microphone L+ uniphone line L- uniphone line LM master line (for connecting the main exchange) NC free terminal (e.g. for connecting two wire sections) B+ connection of accumulator (+) B- connection of accumulator (–)
External panel
XZ electro-catch (output) GZ electro-catch supply input (mass) VZ electro-catch supply input (+12V DC) PR door opening pushbutton T digital transmission VS el. supply of the cassette digital part GD digital mass (display system) MC microphone MG mass of microphone SP loudspeaker SG mass of loudspeaker C+ video signal output (symetric) C- video signal output (symetric)
Uniphones
L+ uniphone line L- uniphone line mass BR control of entrance gate drive
CVR-1
T+, T- universal outputs L+, L- digital-analogue line C+, C- video output VC supply (+) GND mass
50
13.2 Description of terminals 13 TECHNICAL DATA
CVR-2
L+, L- digital-analogue line C+, C- video output +15V supply (+) GND mass
CVP-2
CSA selection of video input V+ supply of switch (+) V- supply of switch (–) LM LM line L- line L+ L+ line L­X+,X- vision signal output Y+,Y- vision signal output C1+,C1- video input C2+,C2- video input C3+,C3- video input (not included into CVP-1) C4+,C4- video input (not included into CVP-1)
Electronic cassette power supply ZS-K-25/01 or TSZZM 25/021M ­wires description
U
SEC1
U
SEC2
U
SEC3
U
PRI
brown
blue
brown
white
red
U
PRI
= ~230V
U
SEC1
= 12,5V / 0,8A
U
SEC1
+ U
SEC2
= 14,5V / 0,8A
U
SEC3
= 12V / 1A
brown
brown
51
14 DIMENSIONS OF ELEMENTS
14 Dimensions of elements
4 screws fixing casing of the exchange to its base
Figure 26: Dimensions of electronic cassette EC-3100
3482
132
Figure 27: Dimensions of distributor CVR-1, CVR-2, switch CVP-2 and MRL-1 module
52
14 DIMENSIONS OF ELEMENTS
Figure 28: Dimensions of panels CP-3100xx with a frame for mounting under plaster
53
14 DIMENSIONS OF ELEMENTS
Figure 29: Dimensions of casings mounted on plaster in horizontal arrangement, for panels CP-3100xx
54
14 DIMENSIONS OF ELEMENTS
Figure 30: Dimensions of casings mounted on plaster in vertical arrangement, for panels CP-3100xx
55
14 DIMENSIONS OF ELEMENTS
81
210
64
186
34
156
64
68
180
CP-3110
NP2511
NP2512
2,5
Figure 31: Dimensions of panels CP-3110 and panels NP2512, NP2511
160
244
81
266
88
NP2521
NP2522
64
136
34
2,5
64
CP-3120
Figure 32: Dimensions of panels CP-3120 and panels NP2522, NP2521
56
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
15 Selection of wires and connection diagrams
Building 1
to next Slave
in the building
CVR-2
15V DC/4A
MVC-6x50
13,5V DC
MVC-6x50
to next
CVR
CVR-1
MV-645x
15V DC
Panel 1
Panel 2
Panel 3
MON1
MON2
MON3
MON4
MON4
MON3
MON2
MON1
Electronic cassette
power supply
CVP-2
MRL-1
EC-3100/U
Distance
Clamps <15m
+15V, GND 1mm
2
Distance U-E
Clamps <50m <150m
L+,L-, 0,5mm 2x0,5mm
C+,C- 0,5mm
Distance CVR-M
Clamps <30m
L+,L-,C+,C- 0,5mm
Distance CVR-M
Clamps <15m <30m
L+,L-,C+,C- 0,5mm
+15V,GND 0,5mm 2x0,5mm
Distance CVR-M
Clamps <30m
L+,L-,C+,C- 0,5mm
VC,GV/GC 0,5mm
6
6
4
4
DISTRIBUTION CABINET
U
M
M
any
YTKSY,UTP
YTKSY,UTP
YTKSY,UTP
YTKSY,UTP,LAN T11,XzTKMXpw
12
8
8
8
2
3x(Cx+,Cx-)
6
6 (CS,V+(VS),
G(GS),L+,L-,LM)
2
connections the same
like in EC-3100/H
E
the furthest
monitor
-
Figure 33: Selection of wires for entry phone CD-3100 in video version - part 1
57
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
Electro-catch
CP-31xx
13,5V DC/1A
CP-31xx
Electro-catch
Panel 1
Panel 2
Panel 3
Panel 4
CVR-2
Building 4
Building 3
Building 2
Door-open
button
Accumulator
12V/6Ah
Electronic cassette
power supply
Distance
Clamps <15m
GZ,XZ 1mm
2
Distance
Clamps <15m
GZ,VZ 1mm
2
Clamps Distance
CP MRL-1 <100m <200m
SG,SP GAx,SPx
MG,MC GAx,MCx 0,5mm 2x0,5mm
GD,T GSx,Tx 0,5mm
C+,C- Cx+,Cx- 0,5mm
Distance
Clamps <15m
AC1,AC2, 1mm
2
AC3,AC4
Distance H-U
Clamps <15m <50m <150m <250m
L+,L-, 0,5mm 2x0,5mm 3x0,5mm
C4+,C4- 0,5mm
MRL-1
CVP-2
EC-3100/H
4
4
8 (MC,GA,SP,T,GS,VS,
KZ(VZA),GZ(GZA))
5 (CS,V+(VS),
G(GS),L+,L-)
6
8
8
12
2
2
DISTRIBUTION CABINET
H
every connection inside
the distribution cabinet make by
0,5mm YTKSY or UTP wires
unless it is otherwise marked
any
any
any
2
2 (GD,PR)
Clamps Distance
CP MRL-1 <15m <50m
SG,SP GAx,SPx
MG,MC GAx,MCx 0,5mm
GD,T GSx,Tx
C+,C- Cx+,Cx- 0,5mm
GD,VS GSx,VSx 0,5mm 2x0,5mm
VZ,GZ KZx-GZx
8
8
4x(Cx+,Cx-)
2 (B+,B-) - 2x0,5mm
OPTION
(L+,L-,
C+,C-,
+15V(V+),
GND(G))
YTKSY,UTP,LAN T11,XzTKMXpw
YTKSY,UTP,LAN T11,XzTKMXpw
YTKSY,UTP,LAN T11,XzTKMXpw
Figure 34: Selection of wires for entry phone CD-3100 in video version - part 2
58
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
Electro-catch
CP-31xx
13,5V DC/1A
CP-31xx
Electro-catch
Panel 1
Panel 2
Panel 3
Panel 4
Building 1
Building 4
Building 3
Building 2
to next Slave
in building
Panel 1
Panel 2
Panel 3
Door-open
button
Accumulator
12V/6Ah
15V DC/1A
Doorbell button
15V DC/4A
OPTION
Electronic cassette
power supply
Electronic cassette
power supply
Distance Clamps <15m
GZ,XZ 1mm
2
Distance Clamps <15m
GZ,VZ 1mm
2
Clamps Distance CP MRL-1 <100m <200m
SG,SP GAx,SPx MG,MC GAx,MCx 0,5mm 2x0,5mm GD,T GSx,Tx 0,5mm
Distance Clamps <15m
AC1,AC2, 1mm
2
AC3,AC4
Distance H-U Clamps <50m <150m <250m EC/H EC/U
L+,L- LM,L- 0,5mm 2x0,5mm 3x0,5mm
MRL-1
EC-3100/H
MRL-1
EC-3100/U
Distance U-E Clamps <50m <150m
L+,L-, 0,5mm 2x0,5mm
2
4
8 (MC,GA,SP,T,GS,VS,
KZ(VZA),GZ(GZA))
6
10
2
2
DISTRIBUTION CABINET
H
DISTRIBUTION CABINET
U
any
any
any
2
2 (GD,PR)
Clamps Distance CP MRL-1 <15m <50m
SG,SP GAx,SPx MG,MC GAx,MCx 0,5mm GD,T GSx,Tx GD,VS GSx,VSx 0,5mm 2x0,5mm VZ,GZ KZx-GZx
6
6
2
OPTION
10
6
6
8
2
E
the furthest
uniphone
-
(B+,B-)
2x0,5mm
2
2
2
2
uniphone
LG-8d
LG-8d
Distance Clamps <15m
GS,VS 1mm
2
any
2 (B1,B2)
2
Distance feeder-LG-8d Clamps <50m <100m
VS,GS 0,5mm 2x0,5mm
2
every connection inside
the distribution cabinet make by
0,5mm YTKSY or UTP wires unless it is otherwise marked
connections the same
like in EC-3100/H
YTKSY,UTP,LAN T11,XzTKMXpw
YTKSY,UTP,LAN T11,XzTKMXpw
YTKSY,UTP,LAN T11,XzTKMXpw
YTKSY,UTP,LAN T11,XzTKMXpw
YTKSY,UTP,LAN T11,XzTKMXpw
Figure 35: Selection of wires for entry phone CD-3100 in audio version
59
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
EC-3100/U
230 V AC
14,5 V AC
0,8 A
12 V AC
1 A
MRL-1 module
White
Brown
GP
VP
L+L-MCGASPTGS
VS
LM
AC4
AC3
AC2
AC1
Brown
Brown
VZA
GZA
GAMCSPGST
VSKZGZ
PANEL 1
MCMGSGSPTGDVSVZGZXZPR
T1
GS1
MC1
SP1
GA1
PANEL 2
MCMGSGSPTGDVSVZGZXZPR
T2
GS2
MC2
SP2
GA2
-
+
Button
NP-xxxx
CP-31xx
Electro-catch
Button
L+
L-
L+
L-
L+
L-
LED
!
Uniphone
Uniphone
VS1
KZ1
GZ1
230 V AC
13,5 V DC/1A
CP-31xx
NP-xxxx
B+
B-
+
-
Accumulator
Electro-catch
Electronic cassette
power supply
ATTENTION!
- Only panel Nr 1 can be fed from the electronic cassette. The other panels should be fed from local feeders.
- Panels Nr 3 and 4 should be connected in the same way, as panel Nr 2.
- Electronic cassette, MRL-1 module, feeder ZS-K-25/01 art. 0018 and commutator CVP-2 should be mounted as close each other as possible.
- In order to improve legibility, connection of list of occupants, accumulator and push-button of door opening has not been included into this diagram. Elements should be connected in a way, as presented in the previous diagrams.
- In the panel 1, set up a jumper on the junction J1 in position 1 Only panel marked with this number will be fed from electronic cassette! In the other panels numbers 2, 3 and 4 should be set up.
!
In this way, a pair of
spiral cables is indicated in the
scheme.
Figure 36: Doorphone system in audio version. Connection of accumulator, list of occupants and push-button of door opening.
60
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
EC-3100/H
230 V AC
14,5 V AC
0,8 A
12 V AC
1 A
MRL-1
White
Brown
GP
VP
L+L-MCGASPTGS
VS
AC4
AC3
AC2
AC1
Brown
Brown
GAMCSPGST
VSKZGZ
PANEL 1
T1
MC1
SP1
GA1
GS1
T2
MC2
SP2
GA2
GS2
T3
MC3
SP3
GA3
GS3
T4
MC4
SP4
GA4
GS4
PANEL 2 PANEL 3 PANEL 4
EC-3100 /U
230 V AC
14,5 V AC
0,8 A
12 V AC
1 A
MRL-1
White
Brown
L+L-MCGASPTGS
VS
AC4
AC3
AC2
AC1
Brown
Brown
GAMCSPGST
VSKZGZ
PANEL 1
T1
MC1
SP1
GA1
GS1
T2
MC2
SP2
GA2
GS2
T3
MC3
SP3
GA3
GS3
PANEL 2 PANEL 3
LM
L+
L-
L+
L-
MAIN ENTRANCES
SUBORDINATE ENTRANCES
Uniphone
Uniphone
CP-31xx
CP-31xx
CP-31xx
CP-31xx CP-31xx
CP-31xx
CP-31xx
VZA
GZA
VZA
GZA
KZ1
VS1
GZ1
KZ1
VS1
GZ1
Electronic cassette
power supply
Electronic cassette
power supply
230V
230V
230V
230V
230V
Figure 37: Doorphone system CD-3100 in audio version with the main entrance
61
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
EC-3100/U
L+L-MCGASPTGS
VS
VZA
GZA
GAMCSPGST
VSKZGZ
PANEL 1
MCMGSGSPTGDVZGZXZ
T1
GS1
MC1
SP1
GA1
CP-31xx
CS
VS
C4-
C3+
C3-
C3+
C2-
C1+
C1-
CS
C4+
V
G
L+
L-
GS
VS
MRL-1 module
CVP-2
input of video signal
from the panel
MON 4
To the next distributors
or change-over switches
CVR-x
C+
L+
C-
L-
X+
X-
VS1
KZ1
GZ1
C+
C-
PANEL 2
MCMGSGSPT
GD
VZGZXZ
T2
GS2
MC2
SP2
GA2
CP-31xx
VS
-
+
Y+
Y-
to another
CVR-x
230 V AC
14,5 V AC
0,8 A
12 V AC
1 A
White
Brown
AC4
AC3
AC2
AC1
Brown
Brown
Electro-catch
Electro-catch
MON 3
MON 2
MON 1
Electronic cassette
power supply
230V
C+
C-
Figure 38: Doorphone system CD-3100 in video version
monitor feeder*
PLUG RJ 45
UTP
NOTE!
-
in every monitor connected to distributor CVR-1 jumper Z1 should be in position UTP+TERM!
-
in distributor at the end of C+ C- line set JP1 to the one of three possible value. This value should be selected experimentally to get the best picture on monitor screens.
1
8
8
1
Distributor CVR-1
brown
8
brown - white
7
green
6
blue - white
5
blue
4
green - white
3
orange (NC)
2
orange - white (NC)
1
L+
VC
GV/GC
C+
L-
C-
MV-64xx
MVC-6x5x
* for MV-64xx - 15V DC/0.8A for MVC-6x5x - 13.5V DC/1A
Figure 39: System CD-3100 video. Connection of monitor - description of plug and socket RJ-45 used for connecting the monitor in use with CVR-1 distributor.
62
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
Electronic
cassette EC3100
230V AC/50Hz
Power supply
15V DC/4A
CVR-2
IN
MVC-6x50
MON4
MON1
......
NC1
L+
L-
NC2
VC
B1
C+
C-
GB
GND
+15V
AUD
CC
GC
GS
VS
1C-
L+
L-
1C+
L+
L-
GND
+15V
C-
L+
L-
C+
AC
AC
-
+
C-
C+
Figure 40: System CD-3100 video. Connection of monitors using CVR-2 distributor - central power supply of monitors
Electronic
cassette EC3100
230V AC/50Hz
Powe supply
13,5V DC/1A
CVR-2
IN
MVC-6x50
MON4
MON1
......
NC1
L+
L-
NC2
230V AC/50Hz
VC
Local power supply 13,5V DC/1A
B1
C+
C-
GB
GND
+15V
AUD
CC
GC
GS
VS
1C-
L+
L-
1C+
L+
L-
GND
+15V
C-
L+
L-
C+
AC
AC
-
+
C-
C+
AC
AC
-
+
Figure 41: System CD-3100 video. Connection of monitors using CVR-2 distributor - local power supply of monitors
63
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
CSV+G
A
L-
L+
L+L-CS
VS
GSMCGASPT-
GS
VZA
GZA
MCGASPTGSKZGZ
PANEL 1
Electro-catch
EC-3100/H
CVP-2
MRL-1 module
VS
VS
CP-31xx
C2+
C2-
MCMGSGSPTGDVSVZGZC+C-
MC1
GA1
SP1
T1
XZ
V
S1
KZ1
GS1
MCMGSGSPT
GD
C+
C-
GZVZVS
XZ
+
-
C2+
C2-
C3+
C3-
C4+
C4-
MC2
GA2
SP2T2GS2
230 V AC
14,5 V AC
0,8 A
12 V AC
1 A
White
Brown
AC4
AC3
AC2
AC1
Brown
Brown
Electronic
cassette
power
supply
PANEL 2
Electro-catch
CP-31xx
X+
X-
Y+
Y-
C+
C-
L-
L+
T+
T-*
C1+
C1-
G
Z1
230V
C1+
C1-
ATTENTION!
- Only panel Nr 1 can be fed from the electronic cassette. The other panels should be fed from local feeders.
- Panels Nr 3 and 4 should be connected in the same way, as panel Nr 2.
- Electronic cassette, MRL-1 module, electronic cassette power supply and commutator CVP-2 should be mounted as close each other as possible.
- In order to improve legibility, connection of list of occupants, accumulator and push-button of door opening has not been included into this diagram. Elements should be connected in a way, as presented in the previous diagrams.
Figure 42: Doorphone system CD-3100 in video version with the main entrance
64
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
CSV+G
A A A A
L-
L+
L+L-CS
VS
GSMCGASPT-
GS
VZA
GZA
MCGASPTGSKZGZ
PANEL 1
Electro-catch
EC-3100/H
CVP-2
MRL-1 module
+
G
T+
T-
C+
C-
L-
L+
VS
VS
CP-31xx
CVR-1
C2+
C2-
MCMGSGSPTGDVSVZGZC+C-
MC1
GA1
SP1
T1
XZ
V
S1
KZ1
GS1
MCMGSGSPT
GD
C+
C-
GZVZVS
XZ
+
-
C2+
C2-
C3+
C3-
C4+
C4-
230 V AC
14,5 V AC
0,8 A
12 V AC
1 A
White
Brown
AC4
AC3
AC2
AC1
Brown
Brown
* ATTENTION!
Clamps C+, C- should be connected with clamps marked as X+,X-
8 brown
4 blue
5 blue-white
2 orange-white
1 orange
7 brown-white
PANEL 2
MC2
GA2
SP2T2GS2
8 brown
4 blue
5 blue-white
2 orange-white
1 orange
7 brown-white
8 brown
4 blue
5 blue-white
2 orange-white
1 orange
7 brown-white
8 brown
4 blue
5 blue-white
2 orange-white
1 orange
7 brown-white
230V
Electro-catch
CP-31xx
Electronic cassette
power supply
X+
X-
Y+
Y-
C+
C-
L+
L-
T+
T-*
C+
C-
L+
L-
T+
T-*
X+
X-
L+
L-
T+
T-*
C+
C-
L+
L-
T+
T-*
C1+
C1-
G
Z1
C1+
C1-
Figure 43: Doorphone system CD-3100 in video version - main entrance with distributor used as signal branch-joint.
65
15 SELECTION OF WIRES AND CONNECTION DIAGRAMS
* Video signal from the main entrance may be received from three different sources:
- Outputs X+,X- of commutator CVP-2
- Outputs Y+,Y- of commutator CVP-2
- Outputs MON1...MON4 from signal distributor CVR-x
- Video signal from the main entrance should be supplied to inputs C4+, C4- of commutator CVP-2
central power supply
of monitors
local power supply
of monitors
C4+
C4-LML-L+X+
X-
L+LML-CSVS
GS
CSV+G
MCGASPT-GS
VZA
GZA
VS
MCGASPTGSKZGZ
VS
PANEL 2
C2+
C2-
MC2
GA2
SP2T2GS2
C1+
C1-
PANEL 3
C3+
C3-
Electro-catch
CP-31xx
L-
C+
L+
C-
Monitor 4
EC-3100 /U
CVP-2
MRL-1
PANEL 1
MCMGSGSPTGDVSC+C-VZGZ
MC1
GA1
SP1T1GS1
VS1
C1+
C1-
KZ1
GZ1
CP-31xx
Electro-catch
XZ
to the next
distributors
L+
L-
T+
T-
C+*
C-*
Connection with the main entrance
13,5 V DC/1A
CVR-1
CP-31xx
230 VAC
White
Brown
AC4
AC3
AC2
AC1
Brown
Brown
14,5 V AC
0,8 A
12 V AC
1 A
C3+
C3-
MC3
GA3
SP3T3GS3
To the next
slave entrances
L-
L+
C-
C+
GV
VC
ST
C2
VZ-
VZ+
blue
4
blue - white
5
brown - white
7
brown
8
green - white
3
green
6
any monitor
power supply
of monitor
Monitor 3
Monitor 2
C+
C-L-L+
CVR-2
+
-
+15V
GND
15V DC/4A
IN
+15V
1C+
1C-
L-
L+
VS
GS
C+
C-
L-
L+
MON1
MVC-6x50
GND
C+
C-L-L+
CVR-2
+
-
230V
+15V
GND
15V DC/1A
IN
+15V
1C+
1C-
L-
L+
VS
GS
C+
C-
L-
L+
MON1
MVC-6x50
GND
+
-
15V DC/1A
230V
230V
Electronic cassette
power supply
A
C2+
C2-
MCMGSGSPT
GD
C+
C-
GZVZVS
XZ
+
-
230V
+
-
Figure 44: Doorphone system CD-3100 in video version - slave entrance.
66
ul. D¹browskiego 249, 93-231 £ód, tel. (0-42) 671 88 00, fax 671 88 88 e-mail: laskomex@laskomex.com.pl, http://www.laskomex.com.pl
This product was marked with a symbol of crossed dustbin according to European Directive 2002/96/WE on used electric and electronic equipment. Used equipment cannot be placed with other wastes from households. Product user is obliged to give it to the firm which collects used electronic or electric equipment such as local collection points, shops, places appointed by the producer or commune waste collection units.
INSTRUCTION ON ENVIRONMENT PROTECTION
List of collecting units of used Laskomex equipment is available on www.laskomex.com.pl website or telephone No. 42 671 88 68.
Product packing should be removed according to environment protection regulations.
Remember! Selective collection and recycling of used electronic and electric equipment considerably contributes to the protection of human health and life as well as protection of natural environment. Return of packaging materials for the material recycling saves raw materials and reduces generating of wastes.
v1.3 (2010.01.11)