Laserworld CS-500RGBV, CS-250RGY, CS-400RGB User Manual

CS-500RGBV
User Manual
Please read this manual carefully before use!
Contents
Using the laser.......................................................................................................................... 3
Control panel ............................................................................................................................ 3
Operating modes...................................................................................................................... 3
ILDA mode ................................................................................................................................4
DMX mode................................................................................................................................. 4
Maintenance / cleaning ...........................................................................................................4
Technical specifications...........................................................................................................4
ILDA signal................................................................................................................................ 5
Trouble shooting ......................................................................................................................5
Please note................................................................................................................................ 5
EU-declaration of conformity..................................................................................................6
User manual: CS-500RGBV
Rev: 08/2009
page
2
of 6
Checking parts
Please check if all listed parts are included, and are not damaged. Included: 1 x CS-500RGBV laser 1 x Power cable 1 x 9-pin plug (dongle) 2 x key 1 x manual
SAFETY INSTRUCTIONS
If the device has been exposed to great temperature changes, do not switch it on immediately. Condensation water may damage your device. Leave the device switched off until it has reached room temperature. The laser must only be used for shows. Any operation has to be attended and supervised by a skilled and well-trained operator. Never leave this device running unattended and keep it away from children and unauthorized persons. Keep away from heaters and other heat sources. In order to safeguard sufficient ventilation, leave 50 cm of free space around the device. Never direct the laser beam to people or animals. CAUTION LASER DIODE: If you open the device for cleaning, always disconnect from mains!
-HEALTH HAZARD! Never look directly into the light source, as
sensitive persons may suffer an epileptic shock! These lasers are considered a definite eye hazard, particularly at the higher power levels, which WILL cause eye damage. So these laser series models supplied with a key switch to prevent unauthorized use, warning labels and aperture labels affixed to the laser.
Installation safety
Prior to installation and operation of the laser, the paths of the beams and effects should be considered, particularly with respect to how they will reach the audience. If direct audience scanning is desired, then the laser energy in the effects needs to be considered to decide if the effects are safe for direct viewing. Always ensure, that the maximum permissible exposure (MPE) is not exceeded in the area accesible to the public. So install the laser in such a way, that minimum distances and heights ensure the MPE is never exceeded in the public area.
OPERATING THE LASER
The operator has to make sure that laser radiation – also reflected laser radiation – higher than the maximum permissible level is avoided by technical or organisational measures. (Especially with respect to the MPE, see above.) Make sure to use the correct voltage If the device is used in a flying installation, the mounting brackets and an appropriate safety­rope must be fixed. In some countries, the operator must notify the accidence insurance and the authority for industrial safety, before operating a laser. For more information, contact the relevant authorities. Please consider that unauthorized modifications on the device are strictly forbidden due to safety reasons! If this device will be operated in any way differently than described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock, etc.
User manual: CS-500RGBV
Rev: 08/2009
page
3
of 6
Keep surrounding dry and clean. This unit should be keep dry, do not use in the rain or
damp and dusty environment. Projector should be put in a water-proof housing when operated outside. Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog fluid condenses in the housing (if so rearrange hazer and/or laser position).
Operating temperature is 10~35°C. In a new installation, check after some 15-30 minutes
whether the outlet air gets too warm. Regularly check the inside for dust deposits, especially around the fans. Let laser cool off 10minutes after 2 hours of operation,to ensure maximum lifetime for the diode. Distance between laser aperture and projection screen should be not less than 1 meter. Do not turn device on and immediately off again frequently. Do not look into the laser beam directly, especially not with optical instruments.
Do not touch the device with wet hands.
When the laser diode becomes dim or broken, please contact your dealer timely. When returning laser to dealer/manufacturer always use original packaging. Maintenance should be performed every 15-day period. See “cleaning” further down.
Using the laser
Make sure the correct voltage is used. Connect mains. Connect an emergency switch to the 9-pin connector on the backside (pins 1, 2). If you do not wish to connect an emergency switch, connect the 9-pin plug. Depending on the mode selected (see below), laser light should come out of the opening on the front panel – be careful.
Control panel
Operating modes
The following operating modes can be selected from the DIP switch on the backside of the device: DIP switch 1-10 Mode 0,0,0,0,0,0,0,0,0,0 Music activ 1,0,0,0,0,0,0,0,0,0 Automatic mode / beameffects 1,1,0,0,0,0,0,0,0,0 Automatic mode / graphics x,x,x,x,x,x,x,x,x,1 DMX
“Music activ”: patterns are changed/animated to the beat of the music. Sensitivity can be adjusted with the knob on the back of the device.
“Automatic mode”: patterns are changed automatically “DMX“: DMX512 Modus-. Use the first 9 switches to select the address:
X x x x x x x x x 1 2 4 8 16 32 64 128 256 e.g. 1000 0000 01, DMX mode address 1 (1+0+0+0+0+0+0+0+0+0) 0010 0100 01, DMX mode address 36 (0+0+4+0+0+32+0+0+0)
1 Power switch: power on/off 2 Remotelock: connect emergency switch. If
no emergency switch is connected use the 9 pin plug supplied.
3 DIP switch: DMX address/mode selection
(see below) 4 DMX 512 in/out 5 Music mode: sensitivity 6 Microphone 7 Safety switch: laser on/off 8 ILDA connector
User manual: CS-500RGBV
Rev: 08/2009
page
4
of 6
ILDA mode
When an ILDA compatible interface is connected to the laser, the laser is automatically switched to ILDA mode. Output is then controlled from a PC running software. The laser uses pins 4 and 17 of the IDLA signal to detect the presence of an ILDA interface. Further information can be found in the software manual.
DMX mode
Channel Value Function
0~49 Musik active 50~99 Automatic mode / beam effects 100~149 Automatic mode / graphics
1 Mode
150~255 DMX mode 0~5 No beam 6~15, 16~25, 26~35 red, green, yellow (more colours with RGB/V
models)
36~105 Automatic change red/green/yellow
Slow to fast 106~175 Colour change (original pattern colours) 176~245 Pattern randomly coloured
2 Colour
(multicolor models)
246~255 Original pattern colours
3 Pattern 0~255 249 patterns
0~127 Static movement 128~191 Automatic movement up to down (slow to fast)
4 Vertical movement
192~255 Automatic movement down to up (slow to fast) 0~127 Static movement 128~191 Automatic movement right to left (slow to fast)
5 Horizontal movement
192~255 Automatic movement left to right (slow to fast) 0~127 Static rotation 6 Vertical rotation 128~255 Automatic rotation (slow to fast) 0 ~127 Static rotation 7 Horizontal rotation 128~255 Automatic rotation (slow to fast) 0~127 Static rotation 128~191 Automatic rotation clockwise (slow to fast)
8 Rotation
192~255 Automatic rotation ccw (slow to fast) 0~85 Automatic (small to big) 86~170 Automatic (big to small)
9 Zoom
171~255 Autom. (small to big to small etc.)
10 Size 0~255 Size 11 Pointdraw 0~255 Only points are drawn (slow to fast)
0~127 Piecewise drawing of the pattern 12 Drawing 128~255 Piecewise drawing/erasing of the pattern
Maintenance / cleaning
Always disconnect from mains before cleaning/opening the laser. Regularly clean the interior from dust, especially ensure operation of the fans. To open the device remove two screws on the top side of one side panel (front/back), bend the side panel slightly outwards, and slide the top cover out. Use a sponge with alcohol, rather than wet cloth or other chemical liquid, to clean the mirrors. Be careful, even light scratches reduce the output power of the laser. Mirrors need cleaning, when a “halo” is noticeable around the beam, or an unusual high amount of diffuse light can be seen inside the device.
Technical specifications
Lasersources: aircooled DPSS Laser
Power (of the diodes): typical 500mW, minimum 350mW, 50mW 532nm green,
150mW 650nm
red, 150mW 410 (+/-5)nm blue
Laserclass: 3b
Modes: ILDA, DMX 512, auto, music active
ILDA: 25pin ILDA standard Sub-D shaped 25pin connector
Galvos: 20k scanspeed
DMX 512: 12 channels
Patterns: 249
Scanangle: ca. 40°
Beam: ca. 3mm/1mrad
User manual: CS-500RGBV
Rev: 08/2009
page
5
of 6
Accessories: power cable, key switch, interlock plug, manual
Input voltage: AC 100~240V 50/60Hz
Power consumption: 50W
Size: 300 x 240 x 150mm (W x D x H)
Weight: 3.8kg
Operating temperature: 10°-35°C
ILDA signal
Pin out of the standard ILDA signal:
1 Scanner X+ -10V..+10V 14 X- +10V..-10V 2 Scanner Y+ -10V..+10V 15 Y- +10V..-10V 3 Intensity/Blanking+ 0V..+2.5V 16 Intensity/Blanking- 0..-2.5V 4 Interlock A 17 Interlock B 5 Red+ 0..2.5V 18 Red- 0..-2.5V 6 Green+ 0..2.5V 19 Green- 0..2.5V 7 Blue+ 0..2.5V 20 Blue- 0..-2.5V 8 – 12 Not used 23-24 Not used 13 Shutter +5V, max. 20 mA 25 GND Signal ground
Trouble shooting
No beam: emergency switch/dongle not connected. Low output: clean mirrors/window Musicmode not working: wrong DIP switch setting Sensitivity too low No DMX control: wrong DIP switch setting ILDA connected Laser does not switch to ILDA mode:
The interface does not connect pins 4 and 17 (Interlock) of the IDLA signal. See interface
manual
The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17.
Use an adapter that connects pins 4 and 17.
Please note
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual.
Laserworld cannot be made liable for damages caused by incorrect installations and unskilled operation!
User manual: CS-500RGBV
Rev: 08/2009
page
6
of 6
EU-declaration of conformity
We hereby confirm that the following device
Laserworld CS-500RGBV
complies with the essential safety requirements, laid down in the regulations of the committee to assimilate the provisions of law of all participating EU states on the electromagnetic compatibility (89/336/EWG) and with the requirements relating to the Low Voltage Directive (LVD 2006/95/EG) was based on the following standards:
DIN EN 61000-3-2:2000 + A2: 2005 DIN EN 61000-3-3:1995 + A1: 2001
Furthermore, the device is verified in correspondence to the laser class regulations DIN EN 60825-1, if properly set up according to the upper mentioned laser safety regulation. After installing the device, an inspection and official approval is indispensable for the overall setup. The inspection must follow the european guidelines EN 60825-1 and corresponding regulations for the prevention of accidents BGV-B2.
This declaration is executed on behalf of the Laserworld CS-500RGBV manufacture
Laserworld (Switzerland) AG
Oberstrasse 1 8274 Tägerwilen SWITZERLAND
Authorized person: Supervisory board Ms Rhea Gössel
place of business: 8274 Tägerwilen / SWITZERLAND company number: CH-440.3.020.548-6 Commercial Registry Kanton Thurgau
www.laserworld.com info@laserworld.com
representative according to EMVG: Cleantech Europe GmbH Managing Director: Thomas Schulze Fürkhofstr. 5 81927 München / DE