Lasermark LMH, LMH-C, LMH-CR, LMH600, LMH-GR Instruction Manual

INSTRUCTION MANUAL
LMH Series Electronic Self-Leveling Rotary Laser
LMH | LMH-C | LMH-GR | LMH600
57-LMH Shown
LMH Series Rotary Lasers • 1
2 • LMH Series Rotary Lasers
Thank you for purchasing the LaserMark® LMH Electronic Self-Leveling Rotary Laser. Please read this manual thoroughly before operation.
CONTENTS
1. LMH Features ..................................................................................4
2. Laser Safety ....................................................................................7
2.1 Electrical safty procedures ...............................................................................8
2.2 Certifi cations.....................................................................................................9
2.3 Environment Protection ..................................................................................9
3. LMH Operation ...............................................................................9
3.1 Leveling .............................................................................................................9
3.2 Re-leveling ......................................................................................................10
3.2.1 Axis Drive Error (Spindle Error) .......................................................................10
3.3 Anti-Drift System (ADS)...................................................................................10
3.4 Grade Mode: Single Axis Grade (LMH-GR and LMH600 Only) .........................11
3.5 Grade Mode: Dual Axis Slope (LMH600 Only)..................................................13
4. LMH Applications .........................................................................14
4.1 Procedures for Ceiling Grid Applications .......................................................14
4.2 Procedures for Laydown Applications ...........................................................15
4.3 Procedures for General Construction Applications ......................................16
5. LMH Battery Replacement .........................................................17
6. LMH Calibration ............................................................................18
6.1 Upright Position Peg Test (X axis) ..................................................................18
6.1.2 Upright Position Calibration - X axis (LMH, LMH-C, LMH-GR) .........................19
6.1.3 Upright Position Peg Test and Calibration - Y axis (LMH, LMH-C, LMH-GR) ...20
6.2.1 Upright Position Calibration (LMH600) ...........................................................21
6.2.2 Laydown Position Calibration (LMH600) .........................................................22
7. Care of LMH Instrument ............................................................ 23
8. LMH Series Specifi cations ..........................................................23
9. Troubleshooting ..........................................................................24
10. Warranty .......................................................................................26
11. Universal Laser Detector ............................................................27
12. Remote Control ...........................................................................30
LMH Series Rotary Lasers • 3
1.1 LMH AND LMH-C FEATURES
Rotating Laser Head
Battery Low LED
Power On LED
Anti-Drift System On LED
Power On/Off
Button
LMH
POWER
MANUAL
Automatic Self-Leveling
Rotary Laser
ANTI-DRIFT
SYSTEM
LOCATION OF
CALIBRATION BUTTONS
LMH
MANUAL
Rotary Laser
ANTI-DRIFT
SYSTEM
POWER
Automatic Self-Leveling
Battery Compartment Access/
5
8" x 11 Tripod Mounting Thread
Anti-Drift System On/Off Button
Manual Mode
SIDE VIEW
4 • LMH Series Rotary Lasers
Built-In Handle
1.2 LMH-GR FEATURES
Rotating Laser Head
Battery Low LED
Power On LED
Power On/Off
Button
Manual Grade Button
(See LMH600)
LMH
-GR
POWER
LEVEL ON/OFF
ANTI-DRIFT SYSTEM
LMH
-GR
LEVEL ON/OFF
Manual
Grade Setting
ANTI-DRIFT SYSTEM
POWER
Battery Compartment Access/
5
⁄8" x 11 Tripod Mounting Thread
Anti-Drift System On LED
Anti-Drift System On/Off Button
Manual Grade Adjustment Buttons
SIDE VIEW
Manual
Grade Setting
LOCATION OF
CALIBRATION BUTTONS
Built-In Handle
LMH Series Rotary Lasers • 5
1. LMH600 FEATURES
y
Self-Leveling
Rotating Laser Head
Power On LED
Out-of-Level Indicator LED
Variable Speed
Rotation Button
Four Speed Selection.
Speed Decreases
Each Time Button is Pressed
Manual Grade/Slope
Setting Buttons
Auto Beam Positioning
Button. Positions the
Laser Dot in Plumb
Down Position
(Vertical Mode), for
Vertical Laydown Set-ups
Button also used in normal
operation to activate ADS
LMH600 Self-Leveling Rotary Laser
Battery Compartment Access/
5
⁄8" x 11 Tripod Mounting Thread
Power On/Off Button
Battery Low LED
Scan Mode Button Scanning to Preset Angles of 10º, 15º, 45º, 90º and 180º to Increase Visibility
Manual Grade Button Turns unit to manual mode to allow manual grade setting
Head Positioning Button for Fast and Easy Alignment in Vertical/ Horizontal Applications, Clock-Wise and Counter­Clock-Wise Rotation. Pressing and Holding Button Moves the Rotating Beam more Quickl
LMH600 Self-Leveling Rotary Laser
LMH600 Shown
6 • LMH Series Rotary Lasers
X
Y
LOCATION OF
CALIBRATION BUTTONS
2. LASER SAFETY
WARNING: Be sure to read and understand all instructions in this
manual before using this product. Failure to follow all instructions may result in hazardous radiation exposure, electric shock, fi re, and/or bodily injury.
CAUTION: Use of controls or adjustments or performance of
procedures other than those specifi ed in this manual, may result in hazardous radiation exposure.
CAUTION: The use of optical instruments with this product will
increase eye hazard. IMPORTANT: The following labels are on your LMH for your
convenience and safety. They indicate where the laser light is emitted by the level. ALWAYS BE AWARE of their location when using the level.
ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the LMH.
DO NOT remove or deface any warning or caution labels. Removing labels increases the risk of exposure to laser radiation.
DO NOT stare directly at the laser beam or project the laser beam directly into the eyes of others. Serious eye injury could result.
DO NOT place the LMH in a position that may cause anyone to stare into the laser beam intentionally or unintentionally. Serious eye injury could result.
DO NOT use any optical instruments such as, but not limited to, telescopes or transits to view the laser beam. Serious eye injury could result.
ALWAYS remove the batteries when cleaning the laser light aperture or laser lens.
DO NOT operate the LMH around children or allow children to operate the LMH. Serious eye injury could result.
LMH Series Rotary Lasers • 7
ALWAYS turn the LMH "OFF" when not in use. Leaving the LMH "ON" increases the risk of someone inadvertently staring into the laser beam.
DO NOT operate the LMH in combustible areas such as in the presence of fl ammable liquids, gases or dust.
ALWAYS position the pipe laser tool securely. Damage to the LMH and/or serious injury to the user could result if the LMH falls.
ALWAYS use only the accessories that are recommended by the manufacturer of your LMH. Use of accessories that have been designed for use with other rotary lasers could result in serious injury.
DO NOT use this LMH for any purpose other than those outlined in this manual. This could result in serious injury.
DO NOT leave LMH "ON" unattended in any operating mode. ALWAYS repair and servicing must be performed by a qualifi ed repair
facility. Repairs performed by unqualifi ed personnel could result in serious injury.
DO NOT disassemble the LMH. There are no user serviceable parts inside. Disassembling the laser will void all warranties on the product. Do not modify the product in any way. Modifying the LMH may result in hazardous laser radiation exposure.
2.1 ELECTRICAL SAFETY PROCEDURES
WARNING: Batteries can explode or leak, and can cause injury or fi re. To reduce this risk:
ALWAYS follow all instructions and warnings on the battery label and package.
DO NOT short any battery terminals. DO NOT charge alkaline batteries. DO NOT mix old and new batteries. Replace all of them at the same
time with new batteries of the same brand and type.
DO NOT mix battery chemistries. DISPOSE of batteries per local code.
DO NOT dispose of batteries in fi re.
KEEP batteries out of reach of children.
REMOVE batteries if the device will not be used for several months.
8 • LMH Series Rotary Lasers
2.2 CERTIFICATIONS
This laser complies with all applicable portions of title 21 of the Code of Federal Regulations set by the Food and Drug Administrations, Center for Devices, and Radiological Health. Complies with 21CFR
1040.10 and 10040.11 except for deviations pursuant to Laser notice No. 50, dated July 26, 2001.
This LMH has also been tested and complies with the CE certifi cation requirements set forth in the EC regulations 89/336/EEC and EN 61000-6-1 (EN50082-1), EN 61000-6-3 (EN50081-1) and EN 60825-1.
2.3 ENVIRONMENT PROTECTION
Recycle raw materials & batteries instead of disposing of waste. The unit, accessories, packaging & used batteries should be sorted for environmentally friendly recycling in accordance with the your countries latest regulations.
3. LMH SERIES OPERATION
Power On
3.1 Leveling
1: Remove the LaserMark
®
LMH from its case. The unit is shipped with a battery current protection insert, which must be removed before operation. The unit can stand alone on a level, sturdy surface or be secured to a
5
⁄8" -11 surveyor’s tripod.
2: Press the Power button once, and allow time (up to 60 seconds) for the unit to self­level. The Power On LED (Fig. 1) and the laser will blink during this process. Please note, the laser head may begin to rotate before leveling is complete. The
self-leveling speed is approximately 1° per 4 seconds.
3: After self-leveling, the laser head will rotate at 600 RPM (LMH600 will rotate at the last selected speed. Press the Power button again to turn the unit off. (Note: for LMH-GR and LMH600 models, see section
4.3.2 (page 11)
(if blinking, unit is self-leveling)
LMH
Fig. 1
LMH Series Rotary Lasers • 9
3.2 Re-leveling
If the unit is bumped or moved, the unit will automatically attempt to re-level itself. The Power On LED and the laser will blink during this process until the unit is level once again. The laser head will resume rotation.
LMH
X—AXIS ERROR
Y—AXIS ERROR
On the job site, it may be necessary to prevent re-leveling in order to prevent
SPINDLE ERROR
inaccurate measurements by the opera­tor. The LMH’s Anti-Drift System (Section
3.3) is used for this purpose.
LMH600
3.2.1 Axis Drive Error
If the LMH is set up or tipped beyond its self-leveling range of ±5°, the laser head will initially attempt to level; however, when the self-leveling limit is reached, the LEDs will blink, indicating an axis drive error (Fig. 2). Turn the LMH off, move the unit into a more level position, then turn the unit on again.
3.3 Anti-Drift System (ADS) (LMH, LMH-C, and LMH-GR only) By default the ADS feature is ON. The default setting of the ADS func­tion may be set to ON or OFF. When the unit is OFF, press and hold the MANUAL MODE (for LMH-GR, DOWN ARROW button) and then press the POWER button. Once the unit is on, turn the unit off for 15 Sec and then back on. ADS will not be the default when unit is turned ON. To make the unit return to ADS as default, repeat these instructions. When the LMH Series laser is fi rst turned ON, the ADS feature does not begin recording for 1 minute. This allows the instrument to be set up and adjusted. If after 1 minute, the unit is disturbed and the ADS light is fl ashing it is necessary to check any bench marks that have been made and ensure the proper "HI" (Height of Instrument). After the fl ashing ADS has been reset, by pressing the ADS button one time, you will have an additional minute to set and check your measurements. To turn ADS off press the ADS button once. This will put the unit into normal Auto
Self-Leveling mode.
10 • LMH Series Rotary Lasers
X—AXIS ERROR
Y—AXIS ERROR
SPINDLE ERROR
Fig. 2
3.4 Grade Mode: Single Axis Grade (LMH-GR and LMH600 Only)
The single grade function is ideal for general site grading, checking excavations, landscaping and drainage, and more. Manual grade mode can be activated by
Y-Axis
placing the automatic leveling sensor in the OFF position. Pressing the manual grade button will deactivate the sensor.
For greater accuracy in grade applica­tions, precisely level the laser level before entering into GRADE MODE.
LMH-GR LMH600
The selected grade can be as much as a positive or negative 10%, and set in reference to the Y-axis of the unit.
NOTE: The total percent grade possible is from a perfectly level base position. If the unit is mount-
ed on a tripod head which is not perfectly level, then the grade percentage range capable would be reduced by the slope of the base, as this affects the tilt range of the laser head. For maximum grade range, ensure a level tripod head using a spirit level before mounting your unit.
Operator can use one of two methods to generate single-axis grade (Fig. 4). Method 1: Place
Note: For the LMH-GR and LMH600, if the unit is bumped or moved while in Manual Grade mode, the unit will not re-level itself. unit will not re-level itself.
the unit in the middle of the two points (A and B) to get a higher distance. Method 2: Place the unit at one point (A) and locate the other point (B).
On the LMH600, you may fi rst press Variable Rotation button and set the laser to the desired rotation speed. Press the "MANUAL GRADE" button to activate Manual Grade Option. Press the ARROW buttons (Fig. 5B) to adjust to your desired grade.
B
"Y" Axis
Method 1
Beam from Pivot Point = 2.2"
Method 2
A
Fig. 4
LMH Series Rotary Lasers • 11
The unit will react to "MORE" and "LESS" input (Fig 5A and 5B). Allow the unit ample time to react to the input provided, between grade setups or changes.
Fig. 5A
The Rotating Head tilts on the X-Axis. The LEFT ARROW tilts in the "MORE" direction.
LMH600 Only: In Laydown, the Top Plumb Beam moves from left to right.
The Rotating Head tilts on the X-Axis. The RIGHT ARROW tilts in the "LESS" direction.
LMH600 Only: In Laydown, the Top Plumb Beam moves from left to right.
LMH600 Self-Leveling Rotary Laser
“MORE”
“LESS”
Fig. 5B
LMH-GR and LMH600LMH600 Only
The Rotating Head tilts on the Y-Axis. The UP ARROW tilts in the "MORE" direction.
LMH600 Only: In Laydown, the Top Plumb Beam moves upward.
The Rotating Head tilts on the Y-Axis. The DOWN ARROW tilts in the "LESS" direction.
LMH600 Only: In Laydown, the Top Plumb Beam moves downward.
“MORE”
“LESS”
3.4.1 Manual Mode (LMH and LMH-C).
Manual mode disengages the leveling feature; allowing the instrument to be placed in any position (to grade). To activate the Manual Mode, Turn off the ADS (if it is on) and then press the MANUAL mode button. (Note: The instrument should be level and rotating before entering manual mode to eliminate the possibility of error.) Once the button has been pressed the ADS light will blink three times, pause and three times again. Press the MANUAL mode button again to return to normal operation. (Note: When returning to normal operation the unit must be within it’s leveling range. Re-set the unit to a level position before pressing the MANUAL MODE button to the off position.
12 • LMH Series Rotary Lasers
3.5 Grade Mode: Dual Axis Slope (LMH600 Only)
The dual grade function allows more specialized site preparations such as road grading, airport jobs (grading & paving), irrigation, trenching, landfi lls, slopes and embankments, and pipelaying.
To enter a dual grade setting, press the Manual Mode (Grade) button. Then press the ARROW buttons to adjust grade (Fig. 5B). Allow the unit ample time to react to the button being pressed. Refer to examples in Fig. 6 to predict your results.
Y+
Y
Target
X
Y-
X+Y+
X- Y-
X= +10.00% Y= +10.00%
X+Y+
X+X-
X- Y-
X= –10.00% Y= –10.00%
X+
Y+
X-
X= –10.00% Y= +10.00%
Y-
Fig. 6
LMH Series Rotary Lasers • 13
4. LMH SERIES APPLICATIONS
Use your LaserMark® LMH Series Automatic Self-Leveling Laser for these and many other projects:
LMH
ANTI-DRIFT
POWER
SYSTEM
MANUAL
Automatic Self-Leveling
Rotary Laser
Outdoor General Construction Applications & Site Preparation, Grading & Excavating, Batterboards and Foundations, Masonry Work, Setting Concrete Forms, Machinery Installation, Marking Elevation, Septic Work, Paving Roads, Driveways, Checking Depth of Trenches.
4.0 Benchmarking
During the work day, periodically check your initial set-up to ensure that the laser reference has not moved.
1. Establish, at a suitable distance (furthest possible), a benchmark (reference) on a stable surface (ie. tree, building). Periodically during the work day, check the benchmark to ensure that your setup has not moved.
4.1 Procedures for Ceiling Grid Applications (LMH600 Only)
1: Attach the LMH 600 to the
optional wallmount bracket. Be sure the control buttons are facing outward. Tighten­ing the locking screw will secure the unit to the bracket.
14 • LMH Series Rotary Lasers
2: After installing the fi rst piece of ceiling trim, attach the wallmount to it. Be sure the wallmount is secure to the trim.
3: Press the Power button. If the out-of-level indicator is blinking, press the manual grade button to put the unit into automatic mode. Allow the unit to self-level.
4: Adjust the distance of the unit from the grid, typically 1.5-inch (38mm) below the grid. Loosen the adjustment screw and slide the unit up/down on the wall mount. When the desired height has been reached, tighten the adjustment screw to secure the unit.
5: Install the ceiling grid. Attach the magnetic laser target to the ceiling trim being installed. Adjust the height of the trim until the laser beam strikes the target.
Note: Placing the unit into Scan Mode will make installation easier and more effecient.
To place the unit in Scan Mode, press the Scan Mode button until the rotating laser head stops. Press and hold either clock-wise or counter-clock-wise Head Positioning button until the laser beam moves to the working area. Press the Scan Mode button until the rotating beam is scanning the necessary angle.
4.2 Procedures for Laydown Applications (LMH600 Only)
1: Place the unit in the laydown position on a fl at, level surface.
2: Press the Power button. If the "Out-of-Level" indicator is blinking,
LMH600 Shown
LMH Series Rotary Lasers • 15
press the Manual Grade button to put the unit in automatic mode.
3: Press the Auto Beam Positioning button; the laser beam will plumb down over point (Reference Only).
4: Use the left and right Manual Grade buttons for fi ne adjustment.
4.3 Procedures for General Construction Applications
Note: A level plane of laser light is created by the rotating beam of the LMH Series. The laser light can be used to reference elevations with the use of a laser detector.
1: Place the unit on a fl at, level surface such as a tripod. Setup the unit in an area where it can not be obstructed and it will be set at a convenient height.
2: Press the Power button. If the "Out-of-Level" indicator (LMH-GR and LMH600 only) is blinking, press the Manual Grade button to put
the unit in automatic mode.
2a: LMH600 Only – Press the Variable Speed Rotation button to select the desire rotation speed of the laser head.
3 : Take elevation readings using the plane of laser light as a reference.
To take readings, attach the laser detector to the grade rod and place the rod at a point to for an elevation reading. Follow the Detector Operation Procedures in this manual.
LMH
ANTI-DRIFT
POWER
SYSTEM
MANUAL
Automatic Self-Leveling
Rotary Laser
16 • LMH Series Rotary Lasers
5. LMH SERIES BATTERY REPLACEMENT
When the Battery Low LED is lit (Fig. 7), or the LMH operates erratically, replace the batteries.
1: Remove the battery tray by unscrewing the plastic nut around the mounting thread on the bottom of the unit (Fig. 8).
2: Remove the old batteries and replace with four new “D” cell Alkaline batteries.
3: Replace the battery tray. Make sure the battery
Fig. 7
contacts between the battery pack and the unit compartment are aligned.
NOTE: Do not mix old and new batteries. Replace all batteries at the same time with new batteries. Remove batteries before storage of the instrument.
Rechargeable Battery Pack
When using a rechargeable battery pack (included with Cat. #57-LMHD [120V] or #57-LMHE [230V]), the batteries will begin to perform optimally after fi ve full charges and discharges.
You may charge the battery pack within the LMH. Ensure that the power is off, and connect the charging plug to the charging jack on the bottom of the battery pack. Then plug the charger into the appropriate 120/230V AC outlet. Charge time is typically around 8 hours. The LMH can be charged and used at the same time, but only a minimal charge will be applied to the battery pack.
Fig. 8
LMH Series Rotary Lasers • 17
6. LMH SERIES CALIBRATION
Your LaserMark® level is a sealed unit and is calibrated to precise accuracies at the factory. However, a calibration check is recommended before the initial use of your laser, and then periodically from that point forward. Be sure to allow time (up to 30 seconds) for the unit to completely self-level before each check.
Please note the direction of the X and Y axes for the unit (Fig. 9). You will need to refer to this to complete the following steps.
6.1 Upright Position Peg Test (X axis)
®
1: To test the X axis, mount the LaserMark
on a tripod or a level, sturdy surface and place approximately 100 feet (30m) away from a wall. Face the left side of the unit (X- quadrant) to the wall.
Y+
X+X-
Y-
Fig. 9
100'
(30m)
A
2: Press the POWER button and allow the unit to self-level. Using the laser detector, locate and mark
POWER
Automatic Self-Leveling
LMH
ANTI-DRIFT SYSTEM
MANUAL
Rotary Laser
B
the position of the laser line on the wall (“A”, Fig. 10).
®
3: Loosen the LaserMark
from the tripod and rotate the instrument 180°. Ensure that the height of the
Fig. 10
tripod does not change, as this will affect your results. Secure and re-level the unit.
4: Again, locate and mark the position of the laser line on the wall (“B”). No adjustment is necessary if the vertical difference between
1
A and B is less than
/8" (3.5mm)
Repeat the above steps to ensure a correct reading. If the distance
1
is greater than
/8", you will need to calibrate the X axis (next refer to
6.1.2; for LMH600, refer to 6.2.1).
18 • LMH Series Rotary Lasers
6.1.2 Upright Position Calibration - X axis (LMH, LMH-C, LMH-GR)
1: Keep the unit in its current position.
Power Off the unit.
Calibration Mode
X Axis active
2: Power On the unit while holding the ADS button down. You will know if Calibration mode is activated when the Battery Low and ADS LEDs fl ash alternately. Then, the ADS LED will remain lit; this indicates that the unit is calibrating within the X axis (Fig. 11).
LMH
3: Locate the position of the two calibration buttons as shown in (Fig. 12), on the
Fig. 11
LMH-GR the UP and DOWN ARROW buttons change the axis increments. The upper button will produce a positive (+)
4: You must raise or lower the beam to center between points A and B on the wall (Fig. 13). The unit will react to “+” and “–” input within the X+ quadrant, with each single increment moving the beam
1
approximately ±
/16" at 100 feet. If B is below A, increase the increment
(+). If B is above A, decrease the increment (-).
5: The adjustments are automatically saved. You must now repeat the peg test (6.1) to insure you have made the correct calibration. Repeat calibration if necessary. You must allow time for the calibration change to be saved in memory.
B
LMH
POWER
MANUAL
Automatic Self-Leveling
Rotary Laser
ANTI-DRIFT
SYSTEM
Calibrated
A
Fig. 13
X+ facing the wall
LMH and LMH-C
Fig. 12
LMH Series Rotary Lasers • 19
6.1.3 Upright Position Peg Test and Calibration - Y axis (LMH, LMH-C, LMH-GR)
If you wish to test the Y axis at the same time as the X axis, simply keep the unit on from when you tested the X axis and rotate the unit 90° so that the front of the unit is facing the wall. Press the ADS
button to turn the ADS LED off; you are now calibrating within the Y axis (Fig. 14); follow 6.1, steps 2 through 4.
If you are testing the Y axis at a later time than the X axis, mount the
®
LaserMark
on a tripod and place approximately 100 feet (30m) away from a wall, with the handle (Y– quadrant) of the unit facing the wall; follow 6.1, steps 2 through 4.
A
Calibration Mode
Y Axis active
Calibrated
B
Fig. 15
LMH
ANTI-DRIFT
POWER
LMH
MANUAL
Automatic Self-Leveling
Rotary Laser
SYSTEM
Y+ facing the wall
Fig. 14
Calibrate as in 6.1.2, adjusting “+” and “–” input as necessary within the Y+ quadrant (Fig. 15).
If you are unable to calibrate the unit, or if the difference between points A and B is too great to calibrate within the range of the unit, please contact CST/Berger or an
authorized service center for assistance.
20 • LMH Series Rotary Lasers
6.2.1 Upright Position Calibration (LMH600)
1: Keep the unit in its current position. Power
Y+
OFF the unit.
2: Power ON the unit while holding the Clock-Wise button down. You will know if Calibration mode is activated when the Battery Low and Out-of-Level LEDs fl ash alternately. Then, the Power LED will remain lit.
3: The ARROW buttons will produce the increment change as shown in fi gure 17.
Y-
Fig. 16
4: follow 6.1.2, steps 4 through 5. Rotate unit 90 degree to calibrate the other axis.
5: Press the POWER button. This will exit Calibration Mode.
X+X-
Fig. 17
LMH Series Rotary Lasers • 21
6.2.2 Laydown Position Calibration (LMH600)
1: Place the unit in the laydown position on a fl at, level surface 100
feet (30 meter) from a wall (Fig. 18).
2: Press and hold the Clockwise Button, and then press the Power Button. Release both button at the same time.
The Out-of-Level LED and Battery Low indicators blink together, Then the Power indicator illuminates.
Note: For the most accurate check, allow the unit to operate for at least 30 seconds before continuing.
3: Place a plumb line at the wall (Fig. 18).
4: Have the rotating beam scan the wall and physically adjust the unit
so the beam is in-line with the plumb line.
5: If the beam is not in-line with the plumb line, use the UP ARROW and DOWN ARROW buttons to adjust the beam, until it intersects the plumb line.
6: Press the POWER button. This will exit Calibration Mode.
Plumb Line
Fig. 18
Rotating Beam (Dashed Line) is shown NOT in-line with plumb line
Plumb Beam
22 • LMH Series Rotary Lasers
7. CARE OF LMH INSTRUMENT
Always clean the instrument after use. Use a soft, dry cloth to remove any dirt or moisture from the instrument. Do not use benzene, paint thinner, or other solvents to clean the instrument. Remove batteries before storage of the instrument.
8. LMH SERIES SPECIFICATIONS
Description LMH LMH-C LMH-GR LMH600
Leveling Accuracy
'001@"61⁄1±
m)03@mm6.1(±
'001@"23⁄3±
)m03@mm4.2(±
'001@"61⁄1±
)m03@mm6.1(±
'001@"23⁄3±
)m03@mm6.1(±
Recommended Working Range
Laser Diode Visible Red Beam
Self-Leveling Range
Self-Leveling Speed
Dimensions
Weight
Power
Battery Life
Rotation Speed
Operating Temperature
Environment
002otpU
650 nm 650 nm 635 nm 635 nm
º5± º3± º5± º5±
).xorppa(.ces4repº1
d"8⁄3-6Xw"4⁄1-6Xh"8
)mm261Xmm951Xmm302(
±5.5
60±hrs intermittent use LMH, LMH-C; 55hrs intermittent use
LMH-GR, LMH600 (variable with temperature)
30± hrs intermittent use with fully charged battery pack
600 RPM 600 RPM 600 RPM
22ºF to 120ºF (-6ºC to 49ºC)
IPX4 Water Resistant
seirettabhtiw)gk5.2(.sbl
rotcetedresalhtiwretemaid)m016('0
MPR
kcapyrettabelbaegrahcerroseirettabenilaklAllecD)4(ruoF
elbairaV
006,003,051,0
LMH Series Rotary Lasers • 23
9. TROUBLESHOOTING
The following information lists basic tests that can be performed to check the LMH in the event of poor performance.
Check Your Batteries: One of the most common causes of perfor­mance failures is due to defective or incorrectly installed batteries. Check to see if any batteries are installed backwards and correct if necessary.
• Never selectively replace batteries; always replace all of the batteries at the same time with new batteries. It is recommended, if possible, that the batteries be checked with a voltmeter or battery tester to confi rm proper voltage.
• Leaky batteries may have damaged the battery contacts in the battery box.
• Check to see that the battery tray is screwed tightly onto the base of the unit. Also, the fi t between the battery prongs and the batteries may need adjustment, as this fi t may vary over different brands of battery (especially Energizer™ brand, as they are larger in diameter, preventing a proper connection).
• Alkaline batteries are recommended for the best performance and storage life. Rechargeable batteries such as Nickel-Cadmium will provide performance, but are not as desirable due to their lower terminal voltage. Low cost standard Carbon-Zinc batteries may be used in emergencies, but they should be replaced with alkaline batteries when available.
Rechargeable Battery Pack: For maximum battery life, the battery pack must contain a full charge. The batteries will begin to perform optimally after fi ve full charges and discharges.
Unit does not rotate or self-level, or produces Axis Drive Er­ror: Reset the internal processor by turning power off and on again.
You may also try removing the battery tray for 15 seconds to let the capacitor discharge, then replace the tray and try again.
If the unit rotates but does not self-level, be sure that the Anti-Drift System is turned off.
24 • LMH Series Rotary Lasers
LMH Series Errors:
When an error occurs on the LMH Series, turn the unit OFF. Wait 15 seconds, then turn unit ON. If these procedures do not correct error, contact CST/berger.
LMH
X—AXIS ERROR
Y—AXIS ERROR
SPINDLE ERROR
LMH600
X—AXIS ERROR
Y—AXIS ERROR
SPINDLE ERROR
LMH Series Rotary Lasers • 25
10. WARRANTY
This LaserMark® LMH Automatic Self-Leveling Rotary Laser is warranted to the original purchaser to be free from defects in workmanship and material. CST/berger will repair or replace any defective part which may malfunction under normal and proper use within a period of TWO YEARS from the date of purchase without charge of parts and labor, once delivered and shipped prepaid to CST together with proof of date and place of purchase. This warranty is not subject to misuse, abuse, assignment, or transfer. The exclusive remedy under any and all warrants and guarantees, expressed or implied, is limited to repair and/or replacement as provided herein, and CST shall not be liable for damages from loss or delay of equipment uses, consequential, or incidental damage.
Before returning the unit to CST/berger, call (815) 432-9200 for a return authorization number from our Customer Service Department.
Please fi ll out and return the attached warranty registration card.
26 • LMH Series Rotary Lasers
Electronic Laser Detector
1. INTRODUCTION
The LaserMark® Electronic Laser Detector aids in locating and targeting a visible or invisible beam emitted by a rotary laser; perfect for use in outdoor conditions, where sunlight and distance may make locating the beam more diffi cult.
2. FEATURES
LD400 SHOWN
LD400 Includes heavy-duty rod clamp.
Beam Capture
LCD Readout Window
Window
Power ON/OFF
Beam Resolution
50 mm (
2.0 in
)
Volume ON/OFF
Speaker
LCD Readout Window
Battery Door
3. POWER
A 9-volt battery will provide up to 3 months of typical usage. When the unit is turned on and the low battery symbol remains lit, the battery should be replaced.
LMH Series Rotary Lasers • 27
4. OPERATION
1: Mount the unit onto a sighting rod if you are using one. Turn on the unit by pressing the ON/OFF pad. The LCD symbols will momentarily fl ash (Fig. 1) and the “coarse” beam indicator symbol will remain lit and the audio signal will be on.
2: Expose the beam capture window of the laser detector towards the direction of the rotating laser.
High Beam
Low Beam
Speaker Volume
LCD Display
Beam Resolution
Level Beam Indicator
Battery Strength
3: Slowly move the laser detector in an
Fig. 1
upward and downward direction until the LCD beam indicator arrows appear and/or a pulsing audio signal is heard. Use the Beam Resolution feature to choose between the coarse/low setting, used for approximating level or for initial locating of the center level point, the medium setting, used for greater accuracy, and the fi ne/high setting, used for the most accurate pinpointing of level.
4: Move the detector upward when the low beam indicator light is lit (with volume on, a short pulsing audio tone is heard). Move the detector downward when the high beam indicator arrow is lit (with volume on, a long pulsing audio tone is heard). When the beam is level, the level beam indicator line will be lit and a solid audio tone will be heard.
If the detector is not struck by a laser beam after 5-8 minutes, the detector will automatically shut itself off to preserve battery life. Turn the unit back on using the power button.
28 • LMH Series Rotary Lasers
5. SPECIAL FEATURES
This detector has a unique memory feature, which preserves the last position of the laser beam if the detector is moved out of the plane of laser light, as well as built in electronic fi ltering for bright sunlight and electromagnetic interference. Three distinct audio tones (high, on-grade, and low) assist targeting from a distance.
Features speaker Off, Loud (105 dBA) and Louder (125+ dBA), fi ne, medium, and coarse beam resolution settings, and front and back LCD displays. Seven distinct channels of information (Fig. 2) indicate the position of the detector in the plane of laser light. As you move the detector closer to the center, the arrows fi ll in to indicate the laser position.
Fig. 2
6. CARE OF YOUR UNIVERSAL LASER DETECTOR
This unit is gasket sealed for water and dust protection. Use a soft, dry cloth to remove any dirt or moisture from the instrument before storage. Do not use benzene, paint thinner, or other solvents to clean the instrument. Remove battery before long-term storage of the instrument.
7. SPECIFICATIONS
Dimensions: 6.6" h x 3" w x 1" d (169mm x 76mm x 25mm) Weight: 10 oz. (275g) Range: up to 2000' (610m) Beam Detection Sensitivity: Fine, ± .75mm; Medium, ± 1.5mm;
Coarse, ± 3mm
slightly due to make, manufacturer, beam size, or working conditions)
Readout: LCD, LD400-front and rear windows; LD100N-single window
Power: One 9-volt battery; provides 3 months of typical usage
(sensitivity based on standard conditions with most lasers; may vary
LMH Series Rotary Lasers • 29
8. WARRANTY
This LaserMark® Electronic Laser Detector is warranted to the original purchaser to be free from defects in workmanship and material. CST/ Berger will repair or replace any defective part which may malfunction under normal and proper use within a period of ONE YEAR from the date of purchase without charge of parts and labor, once delivered and shipped prepaid to CST/Berger together with proof of date and place of purchase. This warranty is not subject to misuse, abuse, assignment, or transfer. The exclusive remedy under any and all warrants and guarantees, expressed or implied, is limited to repair and/or replacement as provided herein, and CST/Berger shall not be liable for damages from loss or delay of equipment uses, consequential, or incidental damage.
Before returning the unit to CST/Berger, please call (815) 432-9200 for a return authorization number from our Customer Service Department.
Please fi ll out and return the attached warranty registration card.
RC700 Remote control
Used With LMH600 only This section covers the use of the remote control (Cat. #57-RC700). The remote controls all the functions except power, ADS, and calibration features, with a range of up to 100 feet (30m). Requires 2 ‘AA’ Alkaline batteries.
Note: When using the remote in Line Position Mode, the LEFT and RIGHT buttons can be used to position the reference line regardless of the unit being in Rotation, Spot, or Sweep Mode.
(1) Variable Rotation – places instrument in Rotation Mode and adjusts to preset rotational speeds.
(2) Left Arrow and (3) Right Arrow– Line positioning in laydown position and Grade Adjustment X-Axis – Only in manual mode. of the laser.
30 • LMH Series Rotary Lasers
(4) Up Arrow and (5) Down Arrow–Grade Adjustment Y-Axis – Only in manual mode.
(6) CCW and (7) CW – positions the laser in Spot and Sweep modes.
(8) Scan/Sweep Mode – places instrument in Scan/Sweep Mode and
adjusts to preset angles.
(9) Manual – Places the instrument in manual grade if ADS is not selected. In laydown position, allows manual adjustment
(10) Sleep – places the instrument into a “Sleep” mode by shutting down all functions except front panel LEDs. Pressing any other remote button will put the instrument back into it’s last mode of operation. The instrument will shut off after 2 hours if no other remote button is pressed.
10
4
1
9
SWEEPROTATE
8
2
5
LEFT
RIGHT
6
CCW CW
Remote Control
Rotary Laser Levels
Function Buttons
Sweep/Scanning– Preset Angles
Variable Speed Rotation
Clock-wise Head Positioning
Counter-clock-wise Head Positioning
Line Positioning (Vertical)– Left, Right
n/a
Remote is designed for use with rotary laser models–
all control buttons may not be used for some lasers.
Refer to chart above (n/a– no function).
3
7
RC700
LMH Series Rotary Lasers • 31
05/07 Z94-LMHSERIES
32 • LMH Series Rotary Lasers
Loading...