ENGLISH 7
Ideal for aligning on all surfaces
Automatic 5-spot 635 nm laser with magnetically
damped pendulum system. All 5 lasers are set at right
angles to each other. This makes practically all alignment
tasks possible. Additionally, the housing can be turned to
enable horizontal levelling, while the two perpendicular
lasers allow markings to be easily transferred from the
floor to the ceiling. Precision 2 mm/ 10 m, self-levelling
range 4° - 6°, optical signal when tolerance is exceeded.
With the magnetic base, the device can be used everywhere - on building and photo tripods, on inside walls,
steel structures, etc.
Includes: Magnetic base, Laser enhancement glasses,
tightning belt, allen wrench, carrying case and batteries.
General safety instructions
Caution: Do not look directly
into the beam. Lasers must be
kept out of reach of children.
Never intentionally aim the device at people. This is a
quality laser measuring device and is 100% factory
adjusted within the stated tolerance. For reasons of
product liability, we must also draw your attention to
the following: Regularly check the calibration before
use, after transport and after extended periods of
storage.
Warranty
The warranty period is 2 years from the date of
purchase. The warranty covers all material or
manufacturing defects occurring during this time. The
following is excluded from warranty: Damage due to
improper use (e.g. operation with wrong type of
current/voltage, connection to unsuitable power source,
fall onto hard surface, etc.) or improper storage, normal
wear and tear, and defects which only insignificantly
impair the value or suitability for use. Any tampering by
unauthorised persons will render this warranty void. In
the event that you need to claim warranty, please take
the complete device together with all information and
the invoice to one of our dealers or send it in to
Umarex-Laserliner.
LASER LIGHT
DO NOT LOOK INTO
THE BEAM!
CLASS 2 LASER
EN 60825-1:2001
L
Note:
This product is a precision instrument that must be
handled and treated with care. Avoid shocks and
impact. Always keep and carry in the case! Switch all
lasers off and secure the pendulum. For cleaning, use a
soft cloth and glass cleaner.

8 Side beam calibration
port (Y-axix)
9 Magnets
10 5/8” nut for
connection to
constrution tripod
(mount from bottom).
11 Connecting screw
MultiBeam 5
12 Screw mounting holes
(accepts standard
drywall screws)
13 Slot for tightning belt
1
5
4
2
3
6
7
4
12
13
11
10
1 Laser emitting window
2 Rubber grip housing
3 Battery compartment-
cover
4 1/4” nut for connection
to camera tripod
5 ON / OFF-Switch
Pendulum lock
6 Self-leveling pendulum
(inside)
7 Front beam calibration
port (X-axis)
9
Battery replacement
Make sure the batteries
are correctly poled!
A
B
Switch on
Assemble with connecting screw (11) MultiBeam-Laser 5
and magnetic base. Switch the unit on (5). The laserdots
will be projected.
Applications (examples see P. 2)
A Aligning
B Horizontal levelling
C Plumb line
D Height projection
L
Note:
If the device is positioned too much out of level (more
than 4° or 6°), the laser will blink. Position the device on
a more level surface.
8
Magnetic base

L
Note:
Regularly check the calibration before use, after
transport and after extended periods of storage.
Technical Data
Automatic levelling side-side
range forward-backward
+ 4°
+
6°
Accuracy + 2 mm / 10 m
Operating range
(depending on room illumination)
ca. 100 m
Power supply
3 x 1,5V AA /
ca. 24 h
Laser wavelength 635 nm
Laser
Class 2
<
1 mW
Weight 0,4 kg
Operating temperature
-10°C bis
+50°C
Storage temperature
-20°C bis
+ 70°C
Order number 060.020A
Subject to technical changes without
notice
04/2005
Case dimensions – laserbeams
X-axis
Y-axis
Z-axis
32
20
32
70
45
Measures in mm

A
2
<
2 mm / 10 m = OK
A3
A2
A2
A
1
A1
A2
4.
3.
2.
1.
Preparing the calibration check
It is possible for you to check the calibration of the laser.
To do this, position the device midway between 2 walls,
which must be at least 5 metre apart. Switch the device
on. The best calibration results are achieved if the device
is mounted on a tripod.
1 Mark point A1 on the wall.
2 Turn the device 180° and mark point A2. You now
have a horizontal reference between points
A1 and A2.
L
Note: An absolute calibration is only possible in a
specialist workshop. Calibration by yourself is only
approximate and the accuracy of the calibration will
depend on the care with which you proceed. Please
contact your authorised dealer or else the
UMAREXLASERLINER Service Department.
Performing the calibration check
3 Position the device as near as possible to the wall at
the height of point A1. Adjust the device in the X
axis.
4 Turn the device through 180° and mark point A3.
The difference between points A2 and A3 is the tolerance for the X axis (P. 9).
5 If points A2 and A3 are more than 2 mm / 10 m apart
the device is in need of calibration. Remove cover for
laser calibration and adjust laser to point A2 using
enclosed allen wrench.
6 To check the Y axis, repeat steps from 3 to 5.
Calibrating the X- and Y-axis automatically also
calibrates Z-axis.