Laserline 921K User Manual

LASERLINE model 921K immobiliser is a sophisticated electronic device for vehicle protection, which ensures very reliable protection with a simple operation procedure.The system consists of a control unit, LED/Receptacle and two code keys.
The 921K immobiliser deactivates the main electric circuits of the vehicle (starter solenoid, petrol pump, injection or ignition coil...) and simply operates by a coded key that must be touched to a receptacle on the vehicle fascia before starting the vehicle.
Activation of the system is automatically carried out approximately 20 seconds after switching the ignition off. Once activated, a dash fascia mounted LED will flash.
From now on, the immobiliser operates on two specific points of the vehicles starting-ignition or fuel supply systems, to prevent an unauthorised attempt to start the vehicle.
To switch the immobiliser off, touch the coded key into the receptacle and remove. You have approximately 20 seconds to start the vehicle. If you fail to start the vehicle within this 20 seconds the system will re-activate automatically and it will be necessary to re-touch the coded key to the receptacle in order to start the vehicle. Note: always switch OFF the immobiliser before switching ON the ignition key as accidental activation of Self-Learning Procedure may occur. If accidental activation of Self-Learning Procedure does occur, wait for LED to flash at a rate of 1 flash per 2 seconds before disarming.
All the wires of the immobiliser are black and are recognisable by a code printed on the end of them. When the installation is completed, all the codes on the ends of the wires are removed so that they are not identifiable and the immobiliser cannot be neutralised.
There are thousands of millions of combinations for the coded keys, so each key is unique and cannot be replicated. When one of the 2 supplied coded keys is lost, it is necessary to execute the SELF-LEARNING PROCEDURE.
SELF-LEARNING PROCEDUREOPERATING INSTRUCTIONS
1) Deactivate the immobiliser by inserting a
CODED KEY into the receptacle.
2) Turn ignition key to ON position.
3) Insert and hold one of the CODED KEYS into the
receptacle.
4) Maintaining the CODED KEY into the recep­tacle, turn OFF the ignition key.
5) Remove the CODED KEY from the receptacle.
6) Check if the LED is steady ON, as indication of
the beginning of SELF-LEARNING PROCEDURE.
7) Within 10 secods of the LED remaining ON, insert into the receptacle a new/spare CODED KEY, followed by the original CODED KEY first used to enter the SELF-LEARNING PROCEDURE. Each KEY learning is signalled by a short pause of the LED
8) When the 10 seconds from the last CODED KEY as elapsed, the immobiliser exits from the SELF­LEARNING PROCEDURE and displays the EMER­GENCY CODE (PIN CODE) via flashing of the LED.
9) Note the PIN CODE in the space provided at the end of these instructions.
Verify that all CODED KEYS operate; otherwise, repeat the above steps.
EMERGENCY CODE (PIN CODE) DISPLAY PROCEDURE
To display the PIN CODE, activate the self-learning procedure and wait 10 seconds for the LED to switch OFF. The immobiliser will use the LED for displaying 5 sequences of flashes that will correspond to 5
numbers. The following table shows an example of a PIN CODE and the corresponding LED flashes:
For the numbers n° of corresponding flashes
)
5
)
6
)
0
)
5
)
4
On the above example, the PIN CODE to note at the end of these instructions would be 5 6 0 5 4.
It is imperative to note on a piece of paper this Emergency Pin Code, if it is different from the original pin code displayed in the rear of these instructions. This pin code must then be stored in a secure location. Note: If you intend to leave these instructions in the vehicle, the pin code in the back of these instructions should be removed for safekeeping. This emergency code is derived from the first CODED KEY memorised when you self-learn a new CODED KEY. If you want to change the pin code from the original code, you may have to follow the self-learning
procedure more than once alternating the first CODED KEY until a new pin code is given.
n° 5 consecutive LED flashes n° 6 consecutive LED flashes n° 10 consecutive LED flashes n° 5 consecutive LED flashes n° 4 consecutive LED flashes
2 sec. Pause
)
2 sec. Pause
)
2 sec. Pause
)
2 sec. Pause
)
2 sec. Pause
)
HOW TO DISARM THE IMMOBILISER
USING THE “EMERGENCY CODE”
If the CODED KEYS do not work correctly or have been lost, to disarm the immobiliser you must insert the “EMERGENCY CODE” (PIN CODE) as follows:
1) With the immobiliser ON, turn ON the ignition key.
2) The LED in the receptacle will now flash at a rate of 10 seconds ON, 2 seconds OFF, 10 seconds ON,
2 seconds OFF etc.
3) At any point when the LED is OFF, switch the ignition OFF. (If you miss the 2 second period whilst the LED is OFF the LED will again come on for 10 seconds).
Note
After the above operations, any lost or stolen CODED KEYS become useless. Code memorisation can only occur when the LED located in the receptacle is constantly on. No more than 10 seconds must elapse between memorising each CODED KEY. When 4 CODED KEY have been memorised, the immobiliser will automatically exit from the self-learning procedure or 10 seconds after the last CODED KEY was memorised. If a new CODED KEY has been memorised, it is necessary to memorise the original CODED KEYS if their continued use is desired. If only one CODED KEY is available no SELF-LEARNING PROCEDURE will take place and the procedure will enter EMERGENCY CODE (PIN CODE) DISPLAY PROCEDURE. To memorise only one CODED KEY follow the “USING THE EMERGENCY CODE (PIN CODE) TO DISARM THE IMMOBILISER” procedure and memorise single CODE KEY.
4) The LED will start to flash and the immobiliser is ready to accept the PIN CODE. If not interrupted, the LED will flash 10 times. Turn ON the ignition key for 1 second after the LED as displayed the flashes corresponding to each digit of your PIN CODE, read PIN CODE at the end of these instructions from left to right. For a better understanding, see the example.
If the inserted PIN CODE is correct, the immobiliser will disarm itself and automatically enter the “SELF­LEARNING PROCEDURE”, signaling this condition by LED ON for 10”. Follow SELF-LEARNING PROCE­DURE from step 6. If the inserted PIN CODE is wrong, the immobiliser will remain ON.
Loading...