Lascar Electronics EL-USB-TC-LCD Installation And Operation Manual

(603) 746-5524
www.MicroDAQ.com
Distributed by MicroDAQ.com, Ltd.
INSTALLATION AND
OPERATION GUIDE
GUIDE D'OPERATION GUÍA DE OPERACIÓN GUIDA DI FUNZIONAMENTO BEDIENUNGSANLEITUNG
EL-USB-TC-LCD
CCOONNTTEENNTTSS
Distributed by MicroDAQ.com, Ltd. www.MicroDAQ.com (603) 746-5524
Environmental disposal/warnings
Battery installation
Important notes before installing
Software installation
Driver install Windows™ 2000
Driver install Windows™ Windows XP
Driver install Windows™ Windows Vista 32
Using your data logger (quick start)
Status indication (EN)
11
22
33
44
55
66
77
88
99
Button operation (EN)
Indication d’etat (FR)
Fonctionnement du bouton (FR)
Indicación de estado (ES)
Funcionamiento del botón (ES)
Indicazione di stato (IT)
Funzionamento del pulsante (IT)
Statusanzeige (DE)
Steuerung per Knopf (DE)
1111
1133
1155
1177
1199
2211
2233
2255
2277
21
Distributed by MicroDAQ.com, Ltd. www.MicroDAQ.com (603) 746-5524
EENNVVIIRROONNMMEENNTTAALL DDIISSPPOOSSAALL//WWAARRNNIINNGGSS
WWEEEEEE
This product may contain substances that can be hazardous to the environment if not disposed of properly. Electrical and electronic equipment should never be disposed of with general household waste but must be separately collected for their proper treatment and recovery. The crossed-out bin symbol, placed on the product, reminds you of the need to dispose of the product correctly at the end of its life. In this way you will assist in the recovery, recycling and re-use of many of the materials used in this product. At the end of the life of your product please contact your distributor for information on collection arrangements.
Most batteries end up in landfill where their hazardous material can leach into the soil and cause harm.
BBaatttteerryy ddiissppoossaall
It is much more environmentally friendly to recycle batteries in a safe, correct manner. Follow applicable country, state, and local regulations for disposal/recycling of the ½AA battery supplied with your data logger.
The Restriction of Hazardous Substances (RoHS) Directive 2002/95/EC of the European Parliament
RRooHHSS
stipulates that certain hazardous substances must not be present above defined levels in products.
This data logging product is manufactured to be RoHS compliant.
For further information visit: www.lascarelectronics.com/main/environmental-data-logging.php
BBAATTTTEERRYY IINNSSTTAALLLLAATTIIOONN
BBaatttteerryy IInnssttaallllaattiioonn
Before using the data logger you will need to insert the
3.6V 1/2AA battery provided, following the instructions below.
Replacement batteries available from www.lascarelectronics.com, PN: BAT 3V6 1/2AA.
IInnssttaallllaattiioonn ddee llaa bbaatttteerriiee
Avant d'utiliser l'enregistreur de données, vous devez suivre les instructions ci-dessous pour installer la batterie 1/2AA de 3,6 V.
Vous pouvez vous procurer des batteries de rechange auprès de www.lascarelectronics.com, N° de réf. : BAT 3V6 1/2AA.
1
4
CCóómmoo ccoollooccaarr llaa bbaatteerrííaa
Antes de utilizar el registrador de datos, necesitará colocar la batería 1/2AA de 3,6V suministrada, siguiendo estas instrucciones.
Pueden adquirirse baterías de repuesto en www.lascarelectronics.com, Pieza número: BAT 3V6 1/2AA.
2
5
IInnssttaallllaazziioonnee ddeellllaa bbaatttteerriiaa
Prima di utilizzare il data logger, inserire la batteria 1/2 AA da 3,6 V fornita in dotazione seguendo le istruzioni.
Le batterie di ricambio sono disponibili sul sito web www.lascarelectronics.com, N. art.: BAT 3 V6 1/2 AA.
EEiinnsseettzzeenn ddeerr BBaatttteerriiee
Vor der Benutzung des datenloggers muss eine 3,6V 1/2AA Batterie entsprechend der un tenstehenden anweisungen eingesetzt werden.
Ersatzbatterien können über www.lascarelectronics.com bezogen werden; PN: BAT 3V6 1/2AA.
3
6
3
Distributed by MicroDAQ.com, Ltd. www.MicroDAQ.com (603) 746-5524
IIMMPPOORRTTAANNTT NNOOTTEESS BBEEFFOORREE
IINNSSTTAALLLLIINNGG EELL--WWIINN--UUSSBB SSOOFFTTWWAARREE
Please read these notes carefully before proceeding with installation.
The screen shots on the 'START HERE' page are taken from Windows™Vista. If you are installing using Windows™ XP or 2000 the screens may look slightly different; however, the content will be the same.
To install the software and USB driver you must have administrative privileges on the host computer. Contact your IT department if you need further information.
After completing the software installation you must install the driver to use your EL-USB data logger.
iinnssttaallllaattiioonn..
This logger is not designed to be permanently connected to a USB port.
IItt iiss iimmppoorrttaanntt tthhaatt tthhee CCDD iiss lleefftt iinn tthhee ddrriivvee dduurriinngg tthhiiss ffiinnaall ssttaaggee ooff
Please refer to the relevant section for the Windows platform you are using.
SSTTAARRTT HHEERREE
Windows™2000/XP/VISTA(32-bit)
1. Insert the EL-WIN-USB Configuration Software CD into the CD drive of your computer. If the CD does not automatically load, navigate to the CD and double click “
5. Select “
You have installed the EL-WIN-USB Configuration Software successfully. You now have to install the USB hardware driver. Please refer to the relevant section depending on the Windows platform you are using
EEvveerryyoonnee
SSeettuupp
”, click “
2. Installing software requires
NNeexxtt
6. Click “
administrative privileges. Accept
UUsseerr AAccccoouunntt CCoonnttrrooll
the “ enter password if necessary
NNeexxtt
” to start the Installation.
NNOOTTEE
- A progress bar will be displayed
until the installation is complete
” request,
IImmppoorrttaanntt:: LLeeaavvee tthhee CCDD iinn tthhee ddrriivvee wwhhiillee iinnssttaalllliinngg yyoouurr ddrriivveerrss
NNeexxtt
3. Click “
7. EasyLog USB is being installed
IIMMPPOORRTTAANNTT NNOOTTIICCEE
4. Read the “ II AAggrreeee
select “
CClloossee
8. Click “
”. An icon will now be
placed on your desktop
” and “
NNeexxtt
”,
4
5
Distributed by MicroDAQ.com, Ltd. www.MicroDAQ.com (603) 746-5524
WWIINNDDOOWWSS 22000000
USB Driver Installation
1. Insert the USB data logger into a USB port on the computer. The following screens should automatically appear. Windows™2000 refe rs t o the data logger as “ the end of this installation
UUSSBB AAPPII
2. Click “
” until
NNeexxtt
6
WWIINNDDOOWWSS XXPP
WWIINNDDOOWWSS XXPP
IImmppoorrttaanntt:: LLeeaavvee tthhee CCDD iinn tthhee ddrriivvee wwhhiillee iinnssttaalllliinngg yyoouurr ddrriivveerrss
SSeeaarrcchh ffoorr aa ssuuiittaabbllee ddrriivveerr ffoorr
3. Select “ mmyy ddeevviiccee ((rreeccoommmmeennddeedd))
NNeexxtt
” then click
USB Driver Installation
1. Insert the USB data logger into a USB port on the computer. The following screens should
automatically appear. Windows™XP refers to the data logger as “ EExxpprreessssUUSSBB DDeevviiccee
UUSSBB AAPPII ” throughout this installation
” and “
FF3322xx
IImmppoorrttaanntt:: LLeeaavvee tthhee CCDD iinn tthhee ddrriivvee wwhhiillee iinnssttaalllliinngg yyoouurr ddrriivveerrss
2. Ensure the CD is in the CD drive. Select IInnssttaallll tthhee ssooffttwwaarree aauuttoommaattiiccaallllyy
“ ((RReeccoommmmeennddeedd))
NNOOTTEE
- A screen appears, showing files
being copied to your computer
” then click “
NNeexxtt
3. When this window appears, click “Continue Anyway”
NNOOTTEE --
This is a feature of Windows™XP. Selecting “Continue Anyway” will not cause any adverse changes/effects
on your computer
You have successfully installed the necessary software and driver for your EL-USB data logger. Please refer to page 8 within this manual for a guide on how to use the data logger
NNeexxtt
5. Click “
4. Select “ click “
CCDD--RROOMM ddrriivveerrss
NNeexxtt
” only, then
6. Windows™2000 now refers to the data logger as the “ then click “
FF3322xx EExxpprreessss UUSSBB DDeevviiccee
FFiinniisshh
4. Installation is now complete, click FFiinniisshh
5. The Window will close and you will see the following message
You have successfully installed the necessary software and driver for your EL-USB data logger. Please refer to page 8 within this manual for a guide on how to use the data logger
7 8
Distributed by MicroDAQ.com, Ltd. www.MicroDAQ.com (603) 746-5524
WWIINNDDOOWWSS VVIISSTTAA((3322--bbiitt))
USB Driver Installation
1. Insert the USB data logger into a USB port on the computer. The following screens should automatically appear
5. The above window will appear after a few seconds. Click “
NNeexxtt
LLooccaattee aanndd iinnssttaallll ddrriivveerr
2. Select “ ssooffttwwaarree ((rreeccoommmmeennddeedd))
NNeexxtt
6. When this window appears, click
nssttaallll tthhiiss ddrriivveerr ssooffttwwaarree aannyywwaayy
IIn
NNOOTTEE
- This is a feature of Windows™ Vista. Selecting “ aannwwaayy changes/effects on your computer
IInnssttaallll tthhiiss ssooffttwwaarree
will not cause any adverse
IImmppoorrttaanntt:: LLeeaavvee tthhee CCDD iinn tthhee ddrriivvee wwhhiillee iinnssttaalllliinngg yyoouurr ddrriivveerrss
” then click
3. Installing the driver requires administrative privileges. Accept
UUsseerr AAccccoouunntt CCoonnttrrooll
the “ enter password if necessary
7. Installation is now complete, Click FFiinniisshh
” request,
4. The following screen should automatically appear
You have successfully installed the necessary software and driver for your EL-USB data logger. Please refer to page 8 within this manual for a guide on how to use the data logger
NNOOTTEE At various times Vista may ask
security questions; allow access when prompted
UUSSIINNGG YYOOUURR DDAATTAA LLOOGGGGEERR ((QQUUIICCKK SSTTAARRTT))
The EL-USB data logger you have purchased is a stand-alone device. All communication with the data logger is via a USB port of a PC which has Lascar's configuration software and driver installed. To begin take the following steps:
1. Ensure the battery is correctly installed
2. Insert the data logger into an available USB port on your PC
3. Double click on the EasyLog USB icon on your Windowsdesktop
This will load the configuration software. Here you can setup the data logger for a new log, stop and download a data logger that has been recording, view previously saved data in graph format, and check the current status of the attached data logger (including the serial number). Follow screen instructions or consult the help file for further information on running the software.
When setup is complete the data logger should be removed from the USB port to begin recording. If you would like advice on how best to use the data logger for a particular application please contact your nearest Lascar representative.
Loading...
+ 11 hidden pages