DPM 500 3½ Digit LCD Module
The DPM 500 uses advancedcomponents and construction techniques to providea uniquely compactunit. The meteris in a 40 pin DIL
integrated circuit format that can be plugged directly into a DIL socket or panel mounted using the snap in bezel. For single rail use, the
DPM 500S-BL featuresabuilt in negativerailgenerator, enablingthe meter tomeasurea signal referencedtoits own powersupply0V.
12.5mm (0.5“) Digit Height
Programmable Decimal Points
°°
Auto-zero
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)
Backlit Single Rail Version (DPM 500S-BL)
+
-
CF
µA
mV
kΩ
MHz
Annunciators
Stock Number
Standard Meter DPM 500
SCALING
Two resistors Ra andRb may befitted in orderto alter the
full scale reading(F.S.R.) ofthe meter - see table.
Meter will needre-calibration.
Backlit Single Rail Version DPM 500S-BL
Specification Min. Typ. Max. Unit
Accuracy (overall error)* 0.05 0.1 % (±1 count)
Linearity ±1 count
Sample rate 3 sample/sec
Required F.S.R. Ra Rb
2V Note 910k 100k
20V Note 1M 10k
200V Note 1M 1k
2kV Note 1M 100R
200 A 0R 1k
µ
2mA 0R 100R
20mA 0R 10R
200mA 0R 1R
NOTE
Ensure link 10is cutif fitting Ra.
SAFETY
Operating temperature range 0 50 °C
Temperature stability 100 ppm/°C
Supply DPM 500 7.5 9 14
voltage DPM 500S-BL 3.5 5 6.5
V
Supply current DPM 500 150
(not inc. backlighting)
DPM 500S-BL 250
Backlight Voltage 5 V
(DPM 500S-BL) Current 30 60 mA
Input leakage current (Vin = 0V) 1 10 pA
* To ensure maximum accuracy, re-calibrate periodically.
CONNECTOR SOURCING GUIDE
METHOD 40 Pin DIL IC Socket
Aµ
To complywiththe Low Voltage Directive (LVD93/68/EEC), input voltages tothe module’s pins mustnot exceed 60Vdc. If voltagesto the
measuring inputs doexceed60Vdc, then fitscaling resistors externally tothe module. Theuser must ensurethat the incorporationofthe
DPM into the user ’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for
Measuring, Control andLaboratory Use).
DIMENSIONS All dimensions in mm (inches)
1.1
8.2
(0.04)
60.0 (2.36)
30.0 (1.18)
(0.32)
45.0 (1.77)
16.0 (0.63)
Display in TEST mode
a. DPM 500 6.7 (0.26)
DPM 500S-BL 12.1 (0.48)
b. 4.80 (0.19)
Panel cut-out = 57 x 27 (2.24 x 1.06)
5.0
(0.19)
8.5 (0.33)
1
-
+
40
1.87
(0.07)
52 (2.05)
7
V
m
°F
°C
V+
Ω
HI
Hz
TEST
REF
LO
REF
REF+
0.5
(0.02)
V+
K
~
M
BG
-5V
REF-
COM
XDP
IN HI
IN LO
2.54
(0.1)
12
µ
A
20
:
-
E3
AB
XB3
POL
21
15.2 (0.60)
V-
DP1
DP2
DP3
24.8 (0.98)
BP
b
XG3
4.0 (0.16)
a
1
13
-
+
40
12
3
2
10
1
Rb Ra
12
7
5
4
7
REAR VIEW
9
11
20
8
15
14
DPM 500S-BL ONLY
ON-BOARD LINKS
OPTIONAL SCALING
21
RESISTORS
PANELFITTING
Fit the bezel to the front of the panel and locate the meter into the bezel from behind. Alternatively the meter and bezel may be assembled before
fitting to the front of the panel but care must be taken not to use excessive force. Finally fit the window into the front of the bezel.
LASCAR ELECTRONICS LTD.
MODULE HOUSE, WHITEPARISH,
TEL: +44 (0)1794 884567 FAX: +44 (0)1794 884616
WILTSHIRE SP5 2SJ UK
E-mail: sales@lascar.co.uk
LASCAR ELECTRONICS INC.
3750 West 26th Street,
TEL: +1 (814) 835 0621 FAX: +1 (814) 838 8141
Erie, PA 16506 USA
E-mail: us-sales@lascarelectronics.com
LASCAR ELECTRONICS (HK) LIMITED
FLAT C, 5/FL., LUCKY FTY. bldg., 63-65 HUNG TO ROAD
KWUN TONG, KOWLOON, HONG KONG
TEL: +852 2797 3219 FAX: +852 2343 6187
E-mail: b4lascar@samsongroup.com.hk
PIN FUNCTIONS
1, 40. V+ Positive powersupply.
2 -7, 12-14, 17, 38, 39 See
15. - Input forthe polarityannunciator. InternallylinkedtoPOL(pin20). Ifthisisto be externally controlled, cut link 11.
16, 18, 19, 22 XB3, E3, AB, XG3. Outputs for use in auto-rangingapplications.
20. POL Drivefor"-"annunciator. Internallyconnectedbylink11.
21. BP LCD backplane drive waveform.
23. DP3 1.999
24. DP2 19.99 See
25. DP1 199.9
26. V- Negativepower supply. Note thatif theDPM500S-BL isbeingused, the voltage between V+ and V-mustnotexceed6.5V.
27. XDP Connecttorequiredannunciators/DPs(see note).
28. -5V Outputfrom negativerailgeneratorcircuit. Thisoutputisan inversion of V+ (DPM 500S BL ONLY).
29. BG Input for bandgap reference. (1.22V nom).
30. IN LO Negative measuring input. Analogue inputs must be no closer than 1V to either thepositive ornegative supply. The negative
31. IN HI Positivemeasuring input. supply of the DPM 500S-BL is generated internally andmirrorsthepositivesupplyvoltage.
32. COM The ground for theanalogue sectionof theA/Dconverter, heldactively at2.8V(nom)belowV+. COMmustnotbe allowed to sink
33. REF- Negative outputfrom internalreference.
34. REF+ Positiveoutput frominternalreference.
35. REF LO Negative input for reference voltage.
36. REF HI Positiveinput forreferencevoltage.
37. TEST Connecting thispin toV+turnsonthe segments as illustrated. It should not be operated formore thana fewseconds astheDC
40. V+/CLK NormallytiedtoV+viaLink12butcan be used to over ride the internal oscillatorand controlthe sampleratebycuttingLink12and
SPECIAL NOTE: ANNUNCIATORS.
SPECIAL NOTE: ANNUNCIATORS.
excessivecurrent(> 100 A) by connecting it directly to a highervoltage.
µ
voltage applied to the LCD may "burn" thedisplay. Thispin is nominally at 5V below V+ and is the ground forthe digitalsection
of the meter,it canbe usedas anegativesupplytopowerexternallogicup to a maximum of 1mA.
making Link 13.
LED BACKLIT VERSIONS:
Apply 5V DC to thebacklight tabonthe side of the meter. Typical current is30mA. Forhigher voltages, fit a resistorin series.
E.g. For9Vuse150R. Maximum current =60mA.
SPECIAL NOTE: ANNUNCIATORS:
The DPM annunciators (DPs, °C, etc.) can be displayed by connecting them to XDP. However as these
annunciators are normally ‘floating’, under certainconditions they may appear when not wanted. To suppress unwantedannunciators, link themto
the backplane (BP). If the annunciators are being switched, connect them via a 1M resistor to the BP (pin 21). The annunciators will then operate
normally when connected to XDP. Ensure that an annunciator is notconnected directlyto theXDPandBPatthesametime.
VARIOUS OPERATING MODES
ON-BOARD LINKS: In order to quickly and easily change operating modes for
different applications, the meter has several "on-board links". They are designed
to be easily opened(cut) or shorted (soldered).
Do not connect more than one meter to the same power supply if the meters cannot
use the same signal ground. Taking any input beyond the power supply rails will
damage the meter.
V+
1
V+
31
+
±200mV
Links 1, 2,3&4SHORTED.
IN HI
30
IN LO
-
V-
26
V-
Measuring a floating voltage
±200mV
+
-
0V
1V min
Links 1, 3 & 4 SHORTED.
Split supply operation (DPM 500).
30
31
1
V+
IN HI
IN LO
V-
26
source of 200mV full scale.
V+
1
V+
31
IN HI
R
R=
30
0.2
FSR
I
IN LO
V-
26
Links 1, 2, 3, 4 SHORTED.
V-
Measuring current
(supply MUST be isolated).
+
V1
-
+
V2
-
Measuring the ratio of two voltages.
Reading = 1000 V /V
50mV< V <200mV
V <2V .
2
12
31
30
36
35
IN HI
IN LO
REF HI
REF LO
12
V+
V-
1
26
V+
V-
V+
14V max
7V min
V-
Normally
SHORTED
Cut to
OPEN
31
+
±200mV
Links 1,3&4SHORTED.
IN HI
30
-
IN LO
Measuring a single ended input
referenced to supply (DPM 500S-BL).
IIN
31
IN HI
6R2
220K
5K
30
IN LO
32
COM
IOUT
Links 1,3&4SHORTED.
Measuring 4-20mA to read 0-999
(supply must be isolated).
V+
V-
V+
V-
1
26
1
26
Normally
OPEN
Solder to
SHORT
V+
0V
V+
V-
Specifications liable to change without prior warning DPM 500 Issue 5 August/2002 M.C. Applies to DPM 500/7