DPM 1AS-BL
3½ Digit Backlit LCD Voltmeter Module
PRODUCT DESCRIPTION
The DPM 1AS-BL features a 200mV d.c. measurement range with auto-zero andauto-polarity. Decimal points are user
selectable.
to its own power supply GND. The design
of the panel meter's housing allows the module to be low cost means it will
The DPM 1AS-BL features a negative rail generator whichenables the meter to measure a signal referenced
LED backlighting ensures excellent readability under low light conditions.
easily snapped into a panel. The module's
suit high and low volume applications. The DPM 1AS-BL is intended to replace the DPM 1, DPM 1S, DPM 1-BL and
DPM 1S-BL in many applications, usually requiring only minor circuit modifications.
FEATURES
mm (0.22") Digit Height
• 5.5
• 200mV d.c. Full Scale Reading
• 3.0 to 7.5V or 6.0 to 15.0V Operation
•
Auto-zero and Auto-polarity
•
Programmable Decimal Points
•
LED Backlighting
TYPICAL APPLICATIONS
• Precision Instrumentation Systems
• Power Supply Monitoring
• Hand held instruments
• Panel-Mount Indication
• Low Power Voltage Measurement
ORDERING INFORMATION
Stock Number
Standard Meter DPM 1AS-BL
ELECTRICAL SPECIFICATIONS
Specification Min. Typ. Max. Unit
Accuracy (overall error) * 0.1 % (±1 count)
Linearity ±1 count
Sample rate 2.5 samples/sec
Operating temperature range 0 50 °C
Temperature stability 250 ppm/°C
Meter supply voltage V+ to GND configuration 3.0 5.0 7.5 V d.c.
Meter supply current V+ to GND configuration 350 A
Backlight supply voltage 4.75 5.0 *** V d.c.
Backlight supply current @ 5V d.c. 15 30**** mA
Input leakage current (Vin = 0V) 1 10 pA
* To ensure maximum accuracy, re-calibrate periodically.
** Operation of the meter beyond the maximum supply voltage rating may cause permanent damage to the meter.
*** An external series resistor is required above 5V, see Applications.
**** This specification linearly derates to 20mA @ 50°C.
Unless otherwise noted, specifications apply at T =25°C, V =5Vd.c. (f =48kHz) and are tested with the module configured for single ended
input mode.
V+ to V- configuration 6.0 9.0 15.0** V d.c.
µ
V+ to V- configuration
A supply clock
175 A
µ
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed
60Vdc. The user must ensure thatthe incorporationof thepanel meter into the user’s equipment conforms to the
relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and
Laboratory Use).
LASCAR ELECTRONICS LTD.
MODULE HOUSE
WHITEPARISH
WILTSHIRE SP5 2SJ
UK
TEL: +44 (1794) 884567
FAX: +44 (1794) 884616
E-mail: sales@lascar.co.uk
LASCAR ELECTRONICS INC.
PO BOX 50727
PALO ALTO
CA 94303-0727
USA
TEL: +1 (650) 838 9027
FAX: +1 (650) 833 5432
E-mail: lascarus@pacbell.net
www.lascarelectronics.com
LASCAR ELECTRONICS (HK) LIMITED
FLAT C, 5/FL., LUCKY FTY. BLDG.
63-65 HUNG TO ROAD
KWUN TONG KOWLOON
HONG KONG
TEL: +852 2797 3219
FAX: +852 2343 6187
E-mail: b4lascar@samsongroup.com.hk
Page2of4Page 2 of 4
Page1of4
DPM 1AS-BL
DIMENSIONS
All dimensions in mm (inches)
3½ Digit Backlit LCD Voltmeter Module
Panel cut-out: 28.4 x 11.4
(1.12 x 0.45)
PANEL FITTING
Panel
Module
14.0 (0.55)
11.0 (0.43)
0.50 (0.02)
pin width
Panel thickness: 1.0 - 2.5
(0.04 - 0.10)
30.0 (1.18)
28.0 (1.10)
2.00 (0.08)
pin pitch
c
ab d
1.26 (0.05)
5.00 (0.20)
a. 2.00 (0.08)
b. 6.00 (0.24)
c. 1.60 (0.06)
d. 6.00 (0.24)
1
FUNCTIONAL BLOCK DIAGRAM
BL-
8
1
www.lascarelectronics.com
INHI
INLO
V+
Vref
CAL
+
_
A/D
V-
DP3 2 1 XDPGND
2
DP1
LCOM
DP2
(rear view)
XDP
DP3
Page2of4
Page2of4Page 2 of 4
PIN CONFIGURATION
GND
CAL
V-
INHI
BL-
INLO
LXDP
110
V+