Larson Electronics WAL-SL-51-PAR38-LED-12.4-277V, WAL-SL-51-PAR38-LED-12.4 User Manual

Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: sales@LarsonElectronics.com
510' Temporary Tunnel String Light - 51 LED PAR38 Work Lamps - 277V - 12/4 SJTW Cable - Daisy Chain
Part #: WAL-SL-51-PAR38-LED-12.4
Page: 1
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: sales@LarsonElectronics.com
Made in the USA
This temporary tunnel string light consists of 51 industrial grade PAR38 LED lamps with 10' of 12/4 SJTW cable between each unit, stretching a total of 510' in length. This temporary LED string light is connected to a 277V power source via an integrated 5' line-in cable. Each globe light is equipped with a high output LED PAR38 bulb which delivers more light output than 300 watt rough service bulbs and 150 watt PAR38 halogen lamps. The 25 watt LED bulb draws less than 10% the electrical power of a standard 300 watt bulb and less than 20% of standard 150 watt PAR38 lamps, making it suitable for tunnel and temporary lighting applications where long spans are required. Each LED light screws into a molded E26 lamp socket. Fifty-one high output PAR38 style LED lamps producing 2,500 lumens per lamp provide a total of 127,500 lumens of bright white illumination. Each lamp housing is constructed from light weight aluminum, and fitted with an impact and shatter resistant polycarbonate diffuser. These LED light bulbs provide additional safety measures and time savings, given the low heat production and that it does not require replacing for 50,000 hours. Since the LED bulb uses solid state technology, the vibration (dropping, etc.) that degrades conventional incandescent bulbs is not an issue with these LED bulbs.
Click Photo to Enlarge Click Photo to Enlarge
Click Photo to Enlarge Click Photo to Enlarge
Unlike the glass tube design of traditional fluorescent lamps, these LED lamps have no filaments or fragile housings to break during operation. Instead of using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current is applied, emitting light. With LED lights, there is no warm up time or cool down time before re-striking and they provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than fluorescent
Page: 2
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: sales@LarsonElectronics.com
lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional fluorescent lighting. Safety within the workplace is another benefit of LED work lights and temporary lighting. All light sources produce heat. With traditional work lamps, such as incandescent and halogen light sources, the lamp reaches high surface temperatures. These surface temperatures introduce a burn risk to anyone that allows prolonged skin contact with the light source, as well as a fire hazard if a flammable material is accidentally set too close to the light source for an extended period of time. While LED fixtures still produce heat, they are designed with heat sinks to properly disperse the heat. Each LED bulb is engineered to disperse and expel this heat quickly and efficiently, keeping the lamp cooler than traditional light sources. This LED work light operates at a lower surface temperature than a comparable model with a traditional light source, and thus does not present a significant burn risk if an operator or bystander accidentally brushes up against an exposed lamp, and reduce the fire hazard should the fixture accidentally come in contact with a flammable material for a short period of time. This significantly increases the safety within the work environment. Each light has a hook eyelet that allows operators to hang these tasks lights overhead. Utilizing energy efficient LED lamps, operators are able to provide more light coverage from the same amp draw, or lower the amp draw using the same amount of LED lamps as incandescent, compact fluorescent, or halogen lamps. Each LED trouble light has an effective range that approximately covers a 10-12' radius with 20-30 foot candles of light when mounted at 10-15' above the work environment. Unlike fragile incandescent and compact fluorescent lamps that are made from glass, these LED bulbs are extremely durable and can live up to the abuse of harsh working conditions. With a lamp life of 50,000 hours, operators are not constantly having to replace burnt out or broken lamps, reducing down time and lowering the amount of spare lamps required at the job site. Multiple stringer sections can be daisy chained together via 5' whips terminated in twist lock connectors, with a maximum of four stringers daisy chained together. Alternating hots between each daisy chained unit allows these string lights to be connected together, spanning up to 2,040' in length. Previously, it would have been unrealistic to have a complete assembly reaching 510' in length from a single point of power.
Stringer Energy Consumption Comparison (Single Stringer)