Lark Manor™ FDLL1593 Installation & Assembly

Page 1
INSTALLATION AND SAFETY INSTRUCTIONS
FOR YOUR SAFETY
GENERAL
FIXTURE ASSEMBLY
PENDANT INSTALLATION
SEMIFLUSH INSTALLATION
INSTALLATION
GROUNDING INSTRUCTIONS
GROUP A: Connect to Black House Wire
GROUP B: Connect to White House Wire
BLACK
WHITE
*PARALLEL WIRE (round & smooth)
*PARALLEL WIRE (square & ridged)
WHITE OR GREY WITH TRACER
WHITE OR GREY WITHOUT TRACER
BROWN GOLD OR BLACK WITHOUT TRACER
BROWN, GOLD OR BLACK WITH TRACER
FINAL ASSEMBLY
CLEANING
WARNING: BE SURE THE ELECTRICITY TO THE WIRES
YOU ARE WORKING ON IS SHUT OFF; EITHER THE FUSE IS REMOVED OR THE CIRCUIT BREAKER IS SHUT OFF.
You don’t need special tools to install this fixture. Be sure to follow the steps in the order given. Under no circumstances should a fixture be hung on house electrical wires, nor should a swag type fixture be installed on a ceiling, which contains a radiant type heating system. Read instructions carefully. If you are unclear as to how to proceed, consult a qualified electrician. NOTE: Proper wiring is essential for the safe operation of this fixture.
Carefully remove the fixture from the carton and check that all parts are included as shown in figure. Be careful not to misplace any of the screws or parts, which are needed to install this fixture. NOTE: This fixture can be mounted in two ways: SEMI FLUSH
OR PENDANT.
CAUTION: Please buy one hardware bag for pendant installation (not provide) and assembly according to ASSEMBLY INSTRUCTION SHEET OF PART BAG
IMPORTANT: Do not attach fixture directly to outlet box. STEP 1: Thread the coupling (J) onto the nipple (K). STEP 2: Secure the part (П) of the arms (G) to the coupling (J)
with the screws (I), adjust the coupling (H) (is movable) to a suitable height, then secure the part (І) of the arms (G) to the coupling (H) with the screws (F).
IMPORTANT: Do not attach fixture directly to outlet box. STEP 1: Thread the mounting screws (A) into the match holes
in the mounting bar (B).
STEP 2: Secure mounting bar (B) to the outlet box with outlet
box screws (C).
STEP 1: Insert the green grounding screw into the hole with
two raised dimples on the mounting bar. Wrap the ground wire from the fixture (if supplied) around the green grounding screw, then connect it to ground wire from the outlet box (if not fixed on the outlet box) using a wire connector (not supplied). If ground wire from the fixture is not supplied, wrap the ground wire (if not fixed on the outlet box) from the outlet box around the green grounding screw and tighten it.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER SUPPLY WIRES. STEP 2: Take note of the color of the wire(s) on your fixture.
Identify which group your fixture wire(s) falls into and connect the wires according to the directions below:
evenly against the black wire from the outlet box. Do NOT twist wires together before using wire connectors.
STEP 4: Fit a wire connector over the wires and screw the
connector clockwise until you feel firmness.
STEP 5: Try gently to pull the connector off the wires. If you
can pull the connector off, carefully re-do step 3 and 4, as above, and check again for a firm connection.
STEP 6: Connect the fixture wire from group B to the white wire
from the outlet box in the same manner. Make sure no bare wires can be seen outside wire connectors.
STEP 1: After wires are connected, tuck them carefully inside
outlet box, Raise the canopy (D) allowing for the mounting screws (A) to protrude through the holes on canopy (D), and secure with the ball nuts (E).
STEP 2: Install lamps. (Please do not exceed the maximum
capacity recommended on the socket.)
STEP 3: Thread the nut (N) onto the nipple (O) and thread the
nipple (O) into the coupling (M).
STEP 4: Slide the glass (P) and the washer (Q) onto the nipple
(O), then secure the glass (P) with the nut (R).
STEP 5: Slide the cap (S) onto the nipple (O) and secure with
the finial (T).
To clean, wipe fixture with a soft cloth. Clean glass with a mild soap. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.
*NOTE: When parallel wire (SPT-I & SPT-2) is used, the tracer wire is square shaped or ridged and the less tracer wire is round in shape or smooth (seen best when viewed from wire end.)
STEP 3: Take your fixture wire(s) from group A and place
Loading...