Lark Manor™ ATGD7008 Installation Instructions

Page 1
I
H CHAIN
G
F
E
D
A B
C
Junction Box(Ceiling)
A
B C
D
E
F G
White or
HOUSE
Black
WIRES
(Hot)
Smooth
FIXTURE WIRES
Black or
Ribbed
WIRES
FIXTURE
Bare Copper(Ground)
FIXTURE WIRES
Copper
(Ground)
HOUSE
(Neutral)
WIRES White
Bare
Green or
WIRES
HOUSE
Listed
U
L
R
INSTALLA TIONINSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
ASSEMBLING THE FIXTURE ( Fig. 2) .
1. Return the arms to suitable position, see figure.2.
2. Raise the pipe nipple with the hex nut(C) to the top coupling of the
fixture body(D) and securely tighten .
D
3. Attach the crown (B) over end pipe nipple of the fixture body ( D attach the loop(A) to the crown(B) by turning it clockwise until tight.
4 . Attach the knob screw(F) to the fixture body(D),through the hole in the
arm of side, then lock it with the knob screw.
5 . Attach the tube ( E ) on to the lamp holder .Raise the finial(G) to the fixture
body and securely tighten.
6 . Install the light bulbs in accordance with the fixture specifications
NOTE: DO NOT EXCEED THE SPECIFIED
WATTAGE
D
D ) , then
!
HANGING THE FIXTURE ( Fig. 1)
1. Shut off the power at the circuit breaker and remove old fixture from
ceiling, including the old single bar .
2. Carefully unpack new fixture and lay all the parts on a clear surface.
3. Thread nipple (C) into loop (F) until snug.
4. Thread other end of nipple (C) with loop attached into single bar (D)
until snug.
5. Place lock washer (B) over end of nipple protruding t hrough single bar
and thread hex nut (A) onto nipple until tight.
6. Take this single bar assembly and mount to ceiling junction box with
junction box screws (E). Tighten screws securely with screwdriver .
7. Us ing proper chain pliers to open one end link of the chain provided
and connect to the fixture loop (I). Close the link .
8. By measuring, determine correct number of links needed for proper
hanging height. Using proper chain pliers disconnect and discard remaining chain.
9. Lace the fixture wires through the chain.
10. Slip loop collar (H) over the chain, then do the same with the canopy
(G).
11. Open the other end link of the chain and hang the f ixture on the loop
at the ceiling. Close the link.
12. Feed the fixture wires through the loop (F) and nipple (C) and pull
until taut.
13. Slide canopy (G) up flush to ceiling, secure using loop (H).
CONNECTING THE WIRES ( Fig. 3)
1. Take the black wire from the ceiling junction box and the smooth wire
leg from the fixture and twist bare ends together. T wist wire connector onto end of wire until snug.
2. Repeat same process with white junction box wire and ribbed wire leg
of fixture wire. NOTE: Twist wires together in the same direction you twist the wire connector onto wires.
3. If your junction box has a grounding wire (green or bare copper),
attach this wire and the bare copper wire from the fixture together as step 1.If junction box has no ground wire, attach the bare copper fixture wire to the green ground screw on the single bar .
4. Tuck these wire connections nea t ly into the ceiling outlet box and then
raise the canopy (G) all the way to the ceiling. Raise the loop (H) and thread onto ceiling loop protruding through canopy
Fig. 1
Fig. 2
Your
Your
Your
Your installation
box
box
box
box and
Fig. 3
installation
installation
installation is
and
test
and
test
and test
test the
is
is
is now
the
fixture.
the
fixture.
the fixture.
fixture.
now
complete.
now
complete.
now complete.
complete. Return
Return
Return
Return power
power
power
power to
to
to
to the
the
junction
the
junction
the junction
junction
Loading...