Lark Manor™ ATGD6999 Assembly Instructions

Page 1
ASSEMBLING
ASSEMBLING
ASSEMBLING
ASSEMBLING &
For
For
&
INSTALLATION
&
INSTALLATION
& INSTALLATION
INSTALLATION INSTRUCTIONS
Ceiling
Ceiling
Ceiling Mount
Mount
Mount
Mount Light
Light
Light
Light Fixtures
INSTRUCTIONS
INSTRUCTIONS
Fixtures
Fixtures
Fixtures
WARNING!SHUTPOWEROFFATFUSEORCIRCUITBREAKER.
MOUNTING
MOUNTING
MOUNTING
MOUNTING THE
1. Shut off the power at the circuit breaker box. Remove old
fixture and all hardware from Junction Box.
2. Carefully unpack your new fixture and lay out all the parts
on a clear area. Take care not to lose any small parts
necessary for installation.
3. Thread the two Studs about 1/4 ” into the pre-drilled holes in
the Mounting strap spaced the same distance apart as the
holes in the fixture body( A ).
4. Attach the Mounting strap to the Junction Box with the two
Junction Box Screws as shown. The side of the Mounting
strap marked"GND
5.
5.
5.
5. Thread end of pipe nipple ( H ) into the cover (J) and lock it
with the hex nut (K) . Raise the pipe nipple assembly into the
glass(E) and through the hole. Attach cover(G) onto the
glass(E), then lock them with the finial(I).
6.
6.
6.
6. Install the light bulbs in accordance with the fixture’s
specifications. NOTE:
SPECIFIED
SPECIFIED
SPECIFIED
SPECIFIED
7. A ttach the end of arm ( D ) to the cover (J) and screw it with
knob screw ( F ) , then fasten the other end of arm (D) to the
fixture body ( A ) and screw it with ball nut(C).
8. While holding the fixture body assembly towards the
ceiling, connect the electrical wires as Shown in Fig.2,
making sure that all wire nuts are secured.
to wrap the connections with electrical tape. If your outlet
has a ground wire (green or bare copper) , connect the
fixture ground wire to it . Otherwise connect fixture’s
ground wire directly to the Mounting strap with the green
screw provided. After wires are connected, tuck them
carefully inside the Junction Box.
9.
9.
9.
9. P ut fixture body ( A ) onto the junction box, aligning screws
on mounting strap with mounting holes in canopy and lock
it securely with the ball nuts ( B ).
THE
FIXTURE
THE
FIXTURE
THE FIXTURE
FIXTURE (Fig.1)
"
NOTE:
NOTE:
NOTE: DO
WATTAGE.
WATTAGE.
WATTAGE.
WATTAGE.
(Fig.1)
(Fig.1)
(Fig.1)
must face out.
DO
DO
DO NOT
NOT
NOT
NOT EXCEED
EXCEED
EXCEED
EXCEED THE
You
may have
THE
THE
THE
Fig.1
Your
Your
Your
Your
junction
junction
junction
junction box
Fig. 2
FIXTURE WIRES
Black or Smooth
installation
installation
installation
installation is
box
and
box
and
box and
and test
HOUSE WIRES Black
(Hot)
is
now
is
now
is now
now complete.
test
the
test
test the
FIXTURE WIRES White or Ribbed
fixture.
the
fixture.
the fixture.
fixture.
complete.
complete.
complete. Return
HOUSE WIRES White
(Neutral)
Return
Return
Return power
FIXTURE WIRES Bare Copper
(Ground)
Bare Copper(Ground)
HOUSE WIRES Green or
power
power
power to
to
to
to the
the
the
the
MIN 90 SUPPLY CONDUCTORS
U
L
R
Listed
Loading...