Larius Storm 5 Operating And Maintenance Instruction Manual

OPERATING AND
OPERATING AND
MAINTENANCE INSTRUCTION
MAINTENANCE INSTRUCTION
ENGLISH
ELECTRIC PISTON PUMP
ELECTRIC PISTON PUMP
NTRODUCTION ............................................................p.1
WORKING PRINCIPLE ......................................p.2
A
TECHNICAL DATA ..............................................p.2
B
DESCRIPTION OF THE EQUIPMENT ............... p.3
C
TRANSPORT AND UNPACKING .......................p.4
D
SAFETY RULES .................................................p.4
E
SETTING-UP ...................................................... p.5
F
WORKING ..........................................................p.8
G
CLEANING AT THE END OF THE WORK .........p.9
H
ROUTINE MAINTENANCE ................................ p.9
I
PROBLEMS AND SOLUTIONS ......................... p.10
L
M
CORRECT PROCEDURE OF DECOMPRESSION ......
N
REPLACEMENT OF THE PUMPING
GROUP'S GASKET ............................................ p.12
STORM 5
p.11
O
WARNING PLATE .............................................. p.13
P
CLEANING AND/OR REPLACEMENT OF
THE PRESSURE TRANSMITTER .....................p.14
Q
RECIRCULATING-SAFETY VALVE GROUP
REF. 37440 ......................................................... p.15
R
COMPLETE PUMPING GROUP STORM 5 .......p.16
COMPLETE PRESSURE CONTROL
S
DEVICE .............................................................. p.18
DRIVE ASSEMBLING AND SUCTION
T
PIPE ...................................................................p.20
ELECTRIC MOTOR ............................................p.22
U V
COMPLETE TROLLEY .......................................p.23
Z
ACCESSORIES ..................................................p.23
English
Read this operator’s manual
carefully before using the
equipment.
An improper use of this
machine can cause injuries
to people or things.
It indicates an
accident risk or
serious damage to
equipment if this
warning is
not followed.
WE ADVISE THE USE OF THIS EQUIPMENT ONLY BY PROFESSIONAL OPERATORS.
ONLY USE THIS MACHINE FOR USAGE SPECIFICALLY MENTIONED IN THIS MANUAL.
It indicates a fire or explosion risk if this warning is not
followed.
As well as the product purchased, you will receive a range of support services enabling you to achieve the results desired,
quickly and professionally.
It is obligatory to wear suitable clothing as gloves,
goggles and face shield.
1
It indicates important
recommendations
about disposal
andrecycling
process of products
in accordance with
the environmental
regulations.
A
WORKING PRINCIPLE
STORM 5
English
The STORM 5 unit is defined “electric piston pump”. An electric piston pump is used for high pressure painting without air (from this process derives the term ”airless”). The pump is controlled by an electric motor coupled with a reduction gear. A cam shaft and a connecting rod allow to obtain the reciprocating motion necessary to the working of the “pumping group” piston. The piston movement produces a “vacuum”. The product is sucked, pushed towards the pump outlet and then
B
TECHNICAL DATA
SUPPLY (single-phase)*
SUPPLY WITH RUN GENERATOR
MOTOR POWER
MAX. WORKING PRESSURE
MAX. DELIVERY
MATERIAL OUTLET
WEIGHT
LEVEL OF THE SOUND PRESSURE
LENGTH
WIDTH
TOTAL HEIGHT ON TROLLEY
HEIGHT ON TROLLEY WITHOUT HANDLE
sent to the gun through the flexible hose. A mechanical device on the side of the reduction gear casing, allows to adjust and control the pressure of the material coming out of the pump. When the pump reaches the set value, the motor stops and starts again when the value decreases. A safety valve avoiding overpressure, guarantees the total reliability of the equipment.
STORM 5
220V C.A. 50Hz
minimum 9Kw asynchronous
2 kW (2,7 CV)
200 bar (2900 psi)
4,5 L/min (1,29 L/min)
M16 x 1,5 (M)
38 Kg
70dB(A)
(A) 500 mm
(B) 500 mm
(C) 1030 mm
850 mm
*Available on request with special voltages
PARTS OF THE PUMP IN CONTACT WITH THE MATERIAL Stainless Steel AISI 420B, Teflon; Aluminium
C
B
A
2
STORM 5
DESCRIPTION OF THE EQUIPMENT
C
English
1
2
8
2
7
3
7
4
6
5
POS.
1
2
3
4
5
6
8 10 11
Description Description
ON/OFF switch
Pressure control knob
Reduction box
Pumping group
High pressure flexible pipe of compensation
Suction filter
9
POS.
7
Recirculation tube
8
Drain valve
9
Airless manual gun
10
Trigger safety clamp
11
Product flexible pipe connection
3
TRANSPORT
D
AND UNPACKING
STORM 5
English
The packed parts should be handled as indicated in the symbols and markings on the outside of the packing.
Before installing the equipment, ensure that the area to be used is large enough for such purposes, is properly lit and has a clean, smooth floor surface.
The user is responsible for the operations of unloading and handling and should use the maximum care so as not to damage the individual parts or injure anyone.
To perform the unloading operation, use only qualified
and trained personnel (truck and crane operators, etc.) and also suitable hoisting equipment for the weight of
the installation or its parts. Follow carefully all the safety rules. The personnel must be equipped with the necessary
safety clothing.
The manufacturer will not be responsible for the unloa-
ding operations and transport to the workplace of the
machine.
Check the packing is undamaged on receipt of the
equipment. Unpack the machine and verify if there
has been any damage due to transportation. In case of damage, call immediately LARIUS and the
Shipping Agent. All the notices about possible damage
or anomalies must arrive timely within 8 days at least
from the date of receipt of the plant through Registered
Letter to the Shipping Agent and to LARIUS.
The disposal of packaging materials is a customer’s
competence and must be performed in accordance with
the regulations in force in the country where the plant is
installed and used.It is nevertheless sound practice to
recycle packaging materials in an environment-friendly
manner as much as possible.
SAFETY RULES
E
THE EMPLOYER SHALL TRAIN ITS EMPLOYEES
ABOUT ALL THOSE RISKS STEMMING FROM ACCI­DENTS, ABOUT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUT THE GENERAL RULES FOR ACCIDENT PREVENTION IN COMPLIAN­CE WITH INTERNATIONAL REGULATIONS AND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED.
THE BEHAVIOUR OF THE EMPLOYEES SHALL
STRICTLY COMPLY WITH THE ACCIDENT PREVEN­TION AND ALSO ENVIRONMENTAL REGULATIONS IN FORCE IN THE COUNTRY WHERE THE PLANT IS INSTALLED AND USED.
Read carefully and entirely the following in-
structions before using the product. Please save these instructions in a safe place.
The unauthorised tampering/replacement of one or more parts composing the machine, the use of accessories, tools, expendable materials other than those recommended by
the manufacturer can be a danger of accident. The manufacturer will be relieved from tort and criminal liability.
KEEP YOUR WORK PLACE CLEAN AND TIDY. DISORDER WHERE YOU ARE WORKING CREATES A POTENTIAL RISK OF ACCIDENTS.
ALWAYS KEEP PROPER BALANCE AVOIDING UNUSUAL STANCE.
BEFORE USING THE TOOL, ENSURE THERE ARE NOT DAMAGED PARTS AND THE MACHINE CAN WORK PRO­PERLY.
ALWAYS FOLLOW THE INSTRUCTIONS ABOUT SAFETY AND THE REGULATIONS IN FORCE.
KEEP THOSE WHO ARE NOT RESPONSIBLE FOR THE EQUIPMENT OUT OF THE WORK AREA.
NEVER EXCEED THE MAXIMUM WORKING PRESSURE INDICATED.
NEVER POINT THE SPRAY GUN AT YOURSELVES OR AT OTHER PEOPLE. THE CONTACT WITH THE CASTING CAN CAUSE SERIOUS INJURIES.
IN CASE OF INJURIES CAUSED BY THE GUN CASTING, SEEK IMMEDIATE MEDICAL ADVICE SPECIFYING THE TYPE OF THE PRODUCT INJECTED. NEVER UNDER­VALUE A WOUND CAUSED BY THE INJECTION OF A FLUID.
ALWAYS DISCONNECT THE SUPPLY AND RELEASE THE PRESSURE IN THE CIRCUIT BEFORE PERFOR­MING ANY CHECK OR PART REPLACEMENT OF THE EQUIPMENT.
NEVER MODIFY ANY PART IN THE EQUIPMENT. CHECK REGULARLY THE COMPONENTS OF THE SYSTEM.
REPLACE THE PARTS DAMAGED OR WORN.
TIGHTEN AND CHECK ALL THE FITTINGS FOR CONNEC­TION BETWEEN PUMP, FLEXIBLE HOSE AND SPRAY
4
STORM 5
GUN BEFORE USING THE EQUIPMENT.
ALWAYS USE THE FLEXIBLE HOSE SUPPLIED WITH STANDARD KIT. THE USE OF ANY ACCESSORIES OR TOOLING OTHER THAN THOSE RECOMMENDED IN THIS MANUAL, MAY CAUSE DAMAGE OR INJURE THE OPERATOR.
THE FLUID CONTAINED IN THE FLEXIBLE HOSE CAN BE VERY DANGEROUS. HANDLE THE FLEXIBLE HOSE CAREFULLY. DO NOT PULL THE FLEXIBLE HOSE TO MOVE THE EQUIPMENT. NEVER USE A DAMAGED OR A REPAIRED FLEXIBLE HOSE.
The high speed of travel of the product in the
hose can create static electricity through di­scharges and sparks. It is suggested to earth
the equipment. The pump is earthed through the earth cable of the supply.
The gun is earthed through the high pressure flexible hose. All the conductors near the work area must be earthed.
NEVER SPRAY OVER FLAMMABLE PRODUCTS OR
SOLVENTS IN CLOSED PLACES.
Electrical safety precautions
Check the switch is on the "OFF" position before connecting the cable to the mains.
Never carry a plugged-in equipment.
Disconnect the equipment before storing it and before performing any maintenance operation or replacing of ac­cessories.
Do not carry the equipment neither unplug it by pulling the electric cable.
Protect the cable from heat, oil and sharp edges.
When the tool is used outdoors, use only an extension cable suited for outdoor use and so marked.
Never attempt to tamper with the calibre of instruments.
Take care when the pumping rod is moving.
Stop the machine whenever someone is within its vicinity.
Repairs of the electrical equipment should only be carried out by skilled personnel, otherwise considerabledanger to the user may result.
English
NEVER USE THE TOOLING IN PRESENCE OF POTEN­TIALLY EXPLOSIVE GAS.
Always check the product is compatible with
the materials composing the equipment (pump, spray gun, flexible hose and accessories) with which it can come into contact. Never use paints
or solvents containing halogen hydrocarbons (as the methylene chloride). If these products come into contact with aluminium parts can provoke dangerous chemical reactions with risk of corrosion and explosion.
IF THE PRODUCT TO BE USED IS TOXIC, AVOID INHALA­TION AND CONTACT BY USING PROTECTION GLOVES, GOGGLES AND PROPER FACE SHIELDS.
SETTING-UP
F
CONNECTION OF THE FLEXIBLE HOSE TO THE GUN
Connect the high pressure flexible hose push-button, to the pump
(F1)
and to the gun (the use of two wrenches is suggested). NEVER use sealants on fittings’ threads.
(F2)
ensuring to tighten the fittings
F1
TAKE PROPER SAFETY MEASURES FOR THE PRO­TECTION OF HEARING IN CASE OF WORK NEAR THE PLANT.
F2
5
STORM 5
English
It is ADVISED to mount a high pressure manometer at the pump outlet (see on page “Accessories”) to read the product pressure.
It is recommended to use the hose provided with the standard kit (ref.18036).
NEVER use a damaged or a repaired flexible hose.
CHECK ON POWER SUPPLY
Check the plant is earthed.
Check the mains voltage corresponds to the equipment’s
rating.
CONNECTION OF THE TOOLING TO THE POWER SUPPLY
Check the switch (F3) is on the "OFF"(0) position before connecting the cable to the mains.
F3
The supply cable is provided without plug. Use a plug which guarantees the plant earthing. Only a technician or a skilled person should perform the
connection of the plug to the electric cable.
Should anyone use an extension cable between the tooling and the socket, it must have the same characteristics as the cable supplied (minimum
diameter of the wire 2.5 mm2) with a maximum
length of 50 mt. Higher lengths and lower diameters can provoke excessive voltage falls and also an anomalous working of the equipment.
ON (I)
OFF (0)
Place the pressure control knob (F4) on the “MIN” position (turn counterclockwise).
F4
6
STORM 5
WASHING OF THE NEW EQUIPMENT
The equipment has already been adjusted at our factory with light mineral oil left inside the pumping group as protection.
Therefore, wash with diluent before sucking the product.
Lift the suction pipe and dip it into the solvent tank.
Ensure the gun (F5) is without nozzle.
F5
Press the switch (F6) of the equipment ON (I).
F7
English
Point the gun at a container keeping the trigger pressed (so as to drain the oil inside) till a clean solvent comes out. Now,
release the trigger.
Remove the suction pipe and take away the solvent tank.
Point the gun at the solvent tank and press the trigger so as to recover the residual solvent.
• As the pump idles, press the OFF (0) switch to stop the tooling.
F6
ON (I)
OFF (0)
Absolutely avoid to spray solvents indoors. In addition, it is recommended to keep away from the pump in order to avoid the contact between the solvent fumes and the electric motor.
Now the machine is ready. Should you use water paints, besides the solvent wash, a wash with soapy and then clean water is suggested.
Insert the gun trigger lock and assemble the nozzle.
PREPARATION OF THE PAINT
Make sure the product is suitable to be used with a spray gun.
Mix and filter the product before using it. For filtration, use
CLOSE-MESH (ref. 214) and LARGE-MESH (ref.215) LA­RIUS METEX braids.
Make sure the product to be used is compatible with the materials employed for manufacturing the equi­pment (stainless steel and aluminium). Because of that, please contact the supplier of the product
.
Turn clockwise the pressure control knob (F7) so as the machine works at idle speed.
Never use products containing halogen hydrocarbons (as methy- lene chloride). If these products come into contact with aluminium parts of the equipment, can provoke dangerous chemical reactions with risk of explosion.
7
Loading...