Larius 2 Operating And Maintenance Instructions Manual

P A I N T S P R A Y I N G E Q U I P M E N T
Painting
II 2 G c IIB T4
OPERATING AND
MAINTENANCE INSTRUCTIONS
ENGLISH
OPERATING AND
MAINTENANCE INSTRUCTIONS
Ed.
04 - 12
1
LARIUS 2 - painting
English
PNEUMATIC DOUBLE DIAPHRAGM PUMP
WE ADVISE THE USE OF THIS EQUIPMENT ONLY BY PROFESSIONAL OPERATORS.
ONLY USE THIS MACHINE FOR USAGE SPECIFICALLY MENTIONED IN THIS MANUAL.
Thank you for choosing a LARIUS S.R.L. product. As well as the product purchased,
you will receive a range of support services enabling you to achieve the results desired,
quickly and professionally.
Read this operator’s manual
carefully before using the
equipment. An improper use
of this machine can cause
injuries to people or things.
It indicates an
accident risk or
serious damage
to equipment if
this warning is not
followed.
It indicates a fire or explosion risk if this warning is not
followed.
It is obligatory to wear suitable clothing as gloves,
goggles and face shield.
It indicates important
recommendations
about disposal
andrecycling
process of products
in accordance with
the environmental
regulations.
PNEUMATIC DOUBLE DIAPHRAGM PUMP
AIR CONTROL GROUP WITH
TROLLEY ...........................................................p.20
AIR CONT. GROUP WITHOUT TROLLEY
Inox
...........
p.21
Aluminium version
......................................
p.22
FILTER WITH CIRCULATION STAINLESS steel model
..........p.23
Aluminium version...............................................p.24
SUCTION LINE FILTER .................................... p.25
SUCTION TANK MODEL ....................................p.26
WALL-MOUNTED MODEL .................................p.27
DESCRIPTION ................................................... p.28
TECHNICAL FEATURES ................................... p.28
MARKING ........................................................... p.28
SAFETY INSTRUCTIONS FOR INSTALLATION
IN HAZARDOUS AREAS ...................................p.29
EXAMPLE OF INSTALLATION ........................... p.29
DECLARATION OF CONFORMITY ...................p.34
INTRODUCTION ................................................ p.1
WORKING PRINCIPLE ...................................... p.2
TECHNICAL DATA .............................................. p.2
DESCRIPTION OF THE EQUIPMENT ............... p.3
TRANSPORT AND UNPACKING ....................... p.5
SAFETY RULES .................................................p.5
SETTING-UP ...................................................... p.6
OPERATION ....................................................... p.8
CLEANING AFTER THE SPRAY PAINTING OR IN
CASE OF PRODUCT CHANGE .........................p.9
ROUTINE MAINTENANCE ................................p.10
TROUBLESHHOTING ........................................p.11
L2 PUMP Stainless steel version
...........................
p.12
Aluminium version ..............................................p.14
TANK .................................................................. p.16
BASKET FULL ....................................................p.17
FLOW CONTROLLER ........................................p.18
O
O
P
Q
R
K
M N
A B C D E F G H
I
J
O
U V
W
S
T
X
L
Y
Z
2
LARIUS 2 - painting
English
A
B
WORKING PRINCIPLE
The LARIUS 2 unit is defined as being a “diaphragm pump” that is used for low pressure painting. This type of equipment can be used to paint using a number of spray guns. The feed passes through a low pressure flow regulator, fitted with a pressure gauge.
LARIUS 2
MAX WORKING PRESSURE (product)
MAX (air) SUPPLY PRESSURE
AIR INLET PRESSURE
PUMP AIR CONSUMPTION
WEIGHT
LEVEL OF THE SOUND PRESSURE
LENGTH
WIDTH
HEIGHT
7 bar
7 bar
7 bar
120 L/min
22 Kg
70dB(A)
(A) 500 mm
(B) 600 mm
(C) 1060 mm
The LARIUS 2 can also be used as a transfer pump.
TECHNICAL DATA
RATIO 1:1
C
A
B
3
LARIUS 2 - painting
English
POS.
1
2
3
4
5
POS.
6
7
8
9
10
DESCRIPTION OF THE EQUIPMENT
Trolley
Tank cover
Gravity feed tank with 6 liters capacity
Product filter
Flow regulator
Description
Product outlet
Product recycling tap
Product recycling hose
Pump feeding air inlet
Pump feeding air outlet
Description
C
3
4
5
6
10
9
4
2
1
7
8
4
LARIUS 2 - painting
English
POS.
11
12
13
14
15
POS.
16
17
18
19
Air distribution tap
Atomising air outlet
Atomizing air pressure manometer
Atomizing air pressure setting knob
Product inlet
Description
Product pressure setting knob
Air pressure gauge for pump supply
Pilot valve
Spray gun
Description
19
13
18
12
17
16
11
15
14
5
LARIUS 2 - painting
English
D
E
TRANSPORT AND UNPACKING
The packed parts should be handled as indicated in the symbols and markings on the outside of the packing.
Before installing the equipment, ensure that the area to be used is large enough for such purposes, is properly lit and has a clean, smooth floor surface.
The user is responsible for the operations of unloading and handling and should use the maximum care so as not to damage the individual parts or injure anyone.
To perform the unloading operation, use only qualified
and trained personnel (truck and crane operators, etc.) and also suitable hoisting equipment for the weight of the installation or its parts.
Follow carefully all the safety rules. The personnel must be equipped with the necessary
safety clothing.
The manufacturer will not be responsible for the unloading operations and transport to the workplace of the machi­ne.
Check the packing is undamaged on receipt of the equi­pment. Unpack the machine and verify if there has been any damage due to transportation.
In case of damage, call immediately LARIUS and the
Shipping Agent. All the notices about possible damage or anomalies must arrive timely within 8 days at least from the date of receipt of the plant through Registered Letter to the Shipping Agent and to LARIUS.
The disposal of packaging materials is a customer’s competence and must be performed in accordance with the regulations in force in the country where the plant is installed and used.It is nevertheless sound practice to recycle packaging materials in an environment-friendly manner as much as possible.
SAFETY RULES
THE EMPLOYER SHALL TRAIN ITS EMPLOYEES
ABOUT ALL THOSE RISKS STEMMING FROM ACCI­DENTS, ABOUT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUT THE GENERAL RULES FOR ACCIDENT PREVENTION IN COMPLIAN­CE WITH INTERNATIONAL REGULATIONS AND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED.
THE BEHAVIOUR OF THE EMPLOYEES SHALL STRICTLY
COMPLY WITH THE ACCIDENT PREVENTION AND ALSO ENVIRONMENTAL REGULATIONS IN FORCE IN THE COUNTRY WHERE THE PLANT IS INSTALLED AND USED.
Read carefully and entirely the following instructions before using the product. Please save these instructions in a safe place.
The unauthorised tampering/replacement of one or more parts composing the machine, the use of accessories, tools, expendable materials other than those recommended by
the Manufacturer can be a danger of accident. The Manufacturer will be relieved from tort and criminal liability.
KEEP YOUR WORK PLACE CLEAN AND TIDY. DISORDER WHERE YOU ARE WORKING CREATES A POTENTIAL RISK OF ACCIDENTS.
ALWAYS KEEP PROPER BALANCE AVOIDING UNUSUAL STANCE.
BEFORE USING THE TOOL, ENSURE THERE ARE NOT DAMAGED PARTS AND THE MACHINE CAN WORK PRO­PERLY.
ALWAYS FOLLOW THE INSTRUCTIONS ABOUT SAFETY AND THE REGULATIONS IN FORCE.
KEEP THOSE WHO ARE NOT RESPONSIBLE FOR THE EQUIPMENT OUT OF THE WORK AREA.
NEVER EXCEED THE MAXIMUM WORKING PRESSURE INDICATED.
NEVER POINT THE SPRAY GUN AT YOURSELVES OR AT OTHER PEOPLE. THE CONTACT WITH THE CASTING CAN CAUSE SERIOUS INJURIES.
IN CASE OF INJURIES CAUSED BY THE GUN CASTING, SEEK IMMEDIATE MEDICAL ADVICE SPECIFYING THE TYPE OF THE PRODUCT INJECTED. NEVER UNDER­VALUE A WOUND CAUSED BY THE INJECTION OF A FLUID.
ALWAYS DISCONNECT THE SUPPLY AND RELEASE THE PRESSURE IN THE CIRCUIT BEFORE PERFORMING ANY CHECK OR PART REPLACEMENT OF THE EQUIPMENT.
NEVER MODIFY ANY PART IN THE EQUIPMENT. CHECK REGULARLY THE COMPONENTS OF THE SYSTEM.
REPLACE THE PARTS DAMAGED OR WORN.
TIGHTEN AND CHECK ALL THE FITTINGS FOR
6
LARIUS 2 - painting
English
F
SETTING-UP
CONNECTION OF THE FLEXIBLE HOSE TO THE GUN
Connect the dual hose to the pump and the spray gun, making sure that the connections are properly tight (it is best to use two spanners). NEVER use sealants on fittings’ threads.
It is recommended to use the hose provided with the standard kit (rif. 8151).
NEVER use a damaged or a repaired flexible hose.
CONNECTION BETWEEN PUMP, FLEXIBLE HOSE AND
SPRAY GUN BEFORE USING THE EQUIPMENT.
ALWAYS USE THE FLEXIBLE HOSE SUPPLIED WITH STANDARD KIT. THE USE OF ANY ACCESSORIES OR TOOLING OTHER THAN THOSE RECOMMENDED IN THIS MANUAL, MAY CAUSE DAMAGE OR INJURE THE OPERATOR.
THE FLUID CONTAINED IN THE FLEXIBLE HOSE CAN BE VERY DANGEROUS. HANDLE THE FLEXIBLE HOSE CAREFULLY. DO NOT PULL THE FLEXIBLE HOSE TO MOVE THE EQUIPMENT. NEVER USE A DAMAGED OR A REPAIRED FLEXIBLE HOSE.
The high speed of travel of the product in the hose can
create static electricity through discharges
and sparks. It is suggested to ear th the equipment.
The pump is earthed through the earth cable
of the supply. The gun is earthed through the high pressure flexible hose. All the conductors near the work area must be earthed.
NEVER SPRAY OVER FLAMMABLE PRODUCTS OR
SOLVENTS IN CLOSED PLACES.
NEVER USE THE TOOLING IN PRESENCE OF POTEN-
TIALLY EXPLOSIVE GAS.
Always check the product is compatible with the materials
composing the equipment (pump, spray gun, flexible hose and accessories) with which it
can come into contact. Never use paints or
solvents containing Halogen Hydrocarbons
(as the Methylene Chloride). If these products come into contact with aluminium parts can provoke dangerous chemical reactions with risk of corrosion and explosion.
IF THE PRODUCT TO BE USED IS TOXIC, AVOID INHALATION AND CONTACT BY USING PROTECTION GLOVES, GOGGLES AND PROPER FACE SHIELDS.
TAKE PROPER SAFETY MEASURES FOR THE PROTECTION OF HEARING IN CASE OF WORK NEAR THE PLANT.
Electrical safety precautions
Check the "ON/OFF" switch is on the "OFF" position before connecting the cable to the mains.
Never carry a plugged-in equipment.
Disconnect the equipment before storing it and before performing any maintenance operation or replacing of ac­cessories.
Do not carry the equipment neither unplug it by pulling the electric cable.
Protect the cable from heat, oil and sharp edges.
When the tool is used outdoors, use only an extension cable suited for outdoor use and so marked.
Never attempt to tamper with the calibre of instruments.
Take care when the pumping rod is moving.
Stop the machine whenever someone is within its vicinity.
Repairs of the electrical equipment should only be carried out by skilled personnel, otherwise considerabledanger to the user may result.
The conditions of guarantee do not apply in the
following situations:
- improper washing and cleaning of components causing malfunction, wear or damage to the equipment or any of its parts;
- improper use of the equipment;
- use that does not conform with applicable national legislation;
- incorrect or faulty installation;
- modifications, interventions and maintenance that have not been authorised by the manufacturer;
- use of non-original spare parts or parts that do not correspond to the specific model;
- total or partial non-compliance with the instruc­tions provided.
CONDITIONS OF GUARANTEE
7
LARIUS 2 - painting
English
F2
F1
F3
PREPARATION OF THE PAINT
Make sure the product is suitable to be used with a spray gun.
Mix and filter the product before using it.
Make sure the product to be used is compatible with the materials employed for manufacturing
the equipment (stainless steel, aluminium
and
carbon steel
).
Because of that, please contact
the supplier of the product.
Never use products containing halogen hydrocarbons (as methylene chloride). If these products come into contact with
aluminium parts of the equipment, can provoke dangerous chemical reactions with risk of explosion.
Point the gun at a container keeping the trigger pressed (so as to drain the oil inside) till a clean solvent comes out. Now, release the trigger.
Point the gun at the solvent tank and press the trigger so as to recover the residual solvent.
• Close the pressure setting knob (F3).
Do not set the pump to work without product, because this could spoil its gaskets.
Absolutely avoid to spray solvents indoors. In addition, it is recommended to keep away from the pump in order to avoid the contact with the solvent fumes.
Now the machine is ready. Should you use water paints, besides the solvent wash, a wash with soapy and then clean water is suggested.
WASHING OF THE NEW EQUIPMENT
The equipment has already been adjusted at our factory with light mineral oil left inside the pumping group as protection. As soon as the connections have been carried out, before putting the product in the tank, it is necessary to rinse the pump by means of the circulation of solvent (thinner for paints).
Clean hoses (F1) and (F2) by blowing compressed air before connecting them.
Make sure that the atomising air supply is shut off.
Rotate the pressure setting knob (F3) slightly clockwise so that the machine operates at minimum power.
8
LARIUS 2 - painting
English
G8
G2
G4
G1
G2
G3
G5
G9
G7
G10
G6
G
OPERATION
START OF THE PAINTING OPERATIONS
• Use the tooling after performing all the SETTING UP operations above described.
• Fill tank (G1) with pure and perfectly filtered product.
Connect up the product hose (G2) from the spray gun (G3) to the flow regulator (G4).
Connect up the air hose (G5) from the spray gun (G3) to the coupling (G6).
Connect the compressed air plant to the quick connection
(G7); the pressure must be of roughly 6 bar, max. 7,5 bar.
Open the recycling tap (G8).
Start pump by means of the knob (G9); the pump will be set to work. Let the product recycle for a short period (2 minutes) and then close the recycling tap (G8).
Set the atomizing air pressure by means of the knob (G10).
Make a spraying test.
The pump is now ready to work.
9
LARIUS 2 - painting
English
H6
H2
H1
H3
H4
H5
SPRAY ADJUSTMENT
Slowly turn the knob on the flow regulator clockwise, until a pressure is obtained that guarantees good atomisation of the product.
An irregular and marked spray on the sides indicates a low working pressure. On the contrary, a too high pressure causes a high fog (“overspray”) and waste of product.
In order to avoid overthickness of paint, let the gun advance sideways (right-left) when spraying.
H
CLEANING AFTER THE SPRAY PAINTING OR IN CASE OF PRODUCT CHANGE
Reduce product pressure to the minimum (0,5-1 bar) by means of knob (H1).
Use knob (H2) to set the air atomisation knob to zero.
Disconnect the return hose (H4) from tank (H3) and introduce it into an empty can for recuperating the product.
Open the recycling tap (H5) and let the pump work until the tank and the pump itself have been emptied.
Close the recycling tap (H5).
Put back the recycling hose (H4) into the tank (H3).
Pour some solvent in the tank (H3).
Open the recycling tap (H5), set the product pressure at the minimum value by means of the knob (H1).
The pump will be set to work. Let the solvent recycle for a short time and then close the recycling tap (H5).
Unscrew the atomizing head (H6) and rinse it with the solvent, put it back and by means of the spray gun discharge in a tank the product left until the solvent comes out.
Always paint with regular parallel bands coats.
Keep a safety and constant distance between the gun and the support to be painted and also keep yourselves perpendicular to it.
NEVER point the spray gun at yourselves or at
other people. The contact with the casting can use serious injuries. In case of injuries caused by the gun casting, seek immediate medical advice specifying the type of the product injected.
10
LARIUS 2 - painting
English
H9
H7
H8
H10
I3
I
ROUTINE MAINTENANCE
Check that all the hose connections are tight.
Clean and, if necessary, replace the worn seals.
Check filters (I1), (I2) and (I3) and replace them when ne­cessary.
Check the nozzle on the spray gun and clean it.
With the spray gun over the thinner tank, press the trigger
in order to let the thinner circulate during at least five minu­tes.
If necessary change the thinner and repeat this operation
more times until all the residues of the product will have been eliminated.
Clean the product hose (H7) by means of a rag and wash
the filters (H8), (H9) and (H10) with the solvent.
After the use of products with a base of polyvinyl alcohol or of water soluble products, first clean the pump with water and then let some alcohol circulate through the plant.
If it is foreseen a long period of standstill for the pump, after the cleaninng let some light mineral oil circulate in order to protect it against corrosion.
I2
I1
11
LARIUS 2 - painting
English
J
TROUBLESHOOTING
Solution
Cause
Problem
The equipment does not suck the
product
The equipment suck but does not
reach the pressure desired
When pressing the trigger, the
pressure lowers considerably
The pressure is normal but the
product is not atomized.
Leakage from the seal-tightening
screw
The atomization is imperfect
Suction filter clogged;
Suction filter too fine;
The equipment sucks air;
Lack of product;
The equipment sucks air;
The circulation tap is open;
Nozzle too big or worn;
The product is too dense;
The nozzle is partially clogged;
There is no atomising air;
The product is too dense;
Gasket worn or needs adjustment;
The nozzle is worn;
Clean or replace it;
Replace it with a larger-mesh filter
(with very dense products, remove
the filter);
Check the suction pipe;
Add the product;
Check the suction pipe;
Close the circulation tap;
Replace it with a smaller one;
Dilute the product, if possible;
Clean or replace it;
Check the flow regulator for the
atomising air;
Dilute the product, if possible;
Replace or adjust the gasket;
Replace it;
12
LARIUS 2 - painting
English
K
STAINLESS STEEL L2 PUMP
13
LARIUS 2 - painting
English
Pos.
Flange
O ring
Lower ball Ø3/4"
Lower ball seat
Upper ball Ø9/16"
Upper ball seat
Lower manifold
Support
Selflocking nut
Membrane pressing
O ring
Fitting
Upper manifold
Pilot valve
Membrane pressing
Screw
PTFE membrane
Rubber membrane
Washer
Elastic ring
8134
8039
91641
8016
8017
8015
8148
8147
8158
8138
301013
8056
8136
8027
8012
8084
8013
8014
8011
8007
1
2
3
4
5
6
7
8
9
10
11
12
16
20
21
22
23
24
25
26
Code Description
2
4
2
2
2
2
1
8
2
2
4
1
1
1
2
2
2
2
2
2
27
28
29
30
31
32
33
34
35
38
39
40
41
53
54
55
56
57
58
Pos.
Code Description
O ring
Seal ring seat
Seal ring
Pilot pad
Elstic ring
Elastic pin
O ring
Rod
Pump body
Screw
Silencer
Grub screw
Fitting
Filter bell
Fine filter
Coarse filter
Elastic ring
Complete filter
Rigide tube
8005
8004
8006
8021
8009
8010
8043
8008
8001
8047
8054
8026
4006
35005/1
35006
35007
35008
35004
8117
2
2
2
2
2
1
2
1
1
12
2
2
1
1
1
1
1
1
14
LARIUS 2 - painting
English
ALUMINIUM L2 PUMP
17
8
16
15
12
2
5
6
1
9
8
4
3
2
13
14
7
11
10
18
19
20
21
22
20
19
23
24
25
26
27
28
28
29
31
31
30
32
46
42
41
40
39
38
37
43
44
45
27
26
25
24
23
19
20
22
21
20
19
18
3
2
4
1
6
5
2
34
33
35
36
47
48
10
12
10
15
LARIUS 2 - painting
English
Flange
O ring
Lower ball Ø3/4"
Lower ball seat
Upper ball Ø9/16"
Upper ball seat
Lower manifold
Washer
Plug 3/8" GAS
Washer
Plug 1/2" GAS
Fitting 1/2" GAS
Bracket
Screw
Upper manifold
Screw
Plug
Nut
Membrane pressing
O ring
PTFE membrane
Rubber membrane
Washer
Elastic ring
O ring
Seal ring seat
Seal ring
Pilot pad
Elastic ring
Elastic pin
O ring
Rod
Pump body
Screw
Silencer
Grub screw
Fitting
Pressure regulator
"I" fitting
Bayonet fitting
Fitting ¼”-Ø4
Hose
Fitting
Union elbow
Manometer
Fitting
Pilot valve
Screw
Pos.
8002
8039
91641
8016
8017
8015
8040
33010
32108
8071
8108
8058
8022
7043
8003
8037
8020
8158
8012
301013
8013
8014
8011
8007
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Codice Descrizione
2
4
2
2
2
2
1
4
2
3
1
2
2
4
1
4
2
2
4
4
2
2
2
2
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
Pos.
Codice Descrizione
8005
8004
8006
8021
8009
8010
8043
8008
8001
8047
8054
8026
8055
3344
8032
3338
8031
8044/1
3343
3341
8167
8056
8027
8084
2
2
2
2
2
1
2
1
1
12
2
2
1
1
1
1
1
1
1
1
1
1
1
4
16
LARIUS 2 - painting
English
Pos.
Cover
Elastic ring
Fine filter
Coarse filter
Rigid tube
Hose Ø10
Fitting
55000
35008
35006
35007
8085
18170
4123
1
2
3
4
5
6
7
Code Description
L
TANK
Pos.
Bracket
Fitting Ø12
Hose Ø12
Screw
Nut
Hopper
4122
22097
96217
54004
91026
55001
8
9
10
11
12
13
Code Description
17
LARIUS 2 - painting
English
M
COMPLETE TROLLEY
1
2
3
3
4
4
4
4
5
5
Complete trolley
Trolley frame L1-L2
Plug Ø 30
96320/1
21653
91047
1
2
Wheels
Wheel washer
Feet Ø 20
91023
95159
8018
3
4
5
Pos.
Code Description
1
1
Pos.
Code Description
2
4
2
18
LARIUS 2 - painting
English
N
FLOW REGULATOR
19
LARIUS 2 - painting
English
Pos. Pos.
Alluminium fluid regulator with
manometer
Key
Cap of regulator
Screw
Screw
Nut
Nut
Screw
Gasket
Gasket
Washer
Diaphragm (nylon)
Gasket
Diaphragm (teflon)
Retainer
Valve rod
Alluminium body
Seat valve
Ball
Nut
Swivel joint (3/8" GAS)
Screw
Carbon steel fitting (GAS)
Union elbow
Connector
Washer
Fluid pressure gauge
Standard spring (0-4 bar)
Special spring (0-7 bar)
7185
7234
7211
7212
7240
7213
7214
7217
7215
7522
7521
7520
7518
7519
7223
7222
7510
7225
7220
7226
7235
7237
33011
5255
8064
11623
8168
7218
7209
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
27
Code Description Code Description
Pos. Pos.
Stainless steel fluid regulator with
manometer
Key
Cap of regulator
Screw
Screw
Nut
Nut
Screw
Gasket
Gasket
Washer
Diaphragm (nylon)
Gasket
Diaphragm (teflon)
Retainer
Valve rod
Stainless steel body
Seat valve
Ball
Nut
Swivel joint (3/8" GAS)
Screw
Stainless steel fitting (GAS)
Union elbow
Connector
Washer
Fluid pressure gauge
Standard spring (0-4 bar)
Special spring (0-7 bar)
7201
7234
7211
7212
7240
7213
7214
7217
7215
7522
7521
7520
7518
7519
7223
7222
7510
7225
7220
7226
7235/1
7237
6147
5255
8064
11623
8168
7218
7209
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
27
Code Description Code Description
20
LARIUS 2 - painting
English
O
AIR CONTROL GROUP ON TROLLEY
1
2
2
3
3
4
4
5
5
6
7
8
9
10
11
11
12
12
9
13
Complete group
Quick coupling 1/4" tube Ø 8
Manometer
Regulator
Regulators bracket
Adapter 1/4"
Fitting 1/4"
Quick connection 1/4" tube Ø 4
96322
4006
8167
3344
510510
3354
8072
8031
1
2
3
4
5
6
7
Ball valve 1/4"
Elbow 1/4"
Bayonet fitting
Nut M6
Screw UNI 5931 TCE M6x16
Nipple 1/4"
4004
5255
3338
91026
54004
96208
8
9
10
11
12
13
Pos.
Code Description
1
2
2
2
2
1
1
Pos.
Code Description
1
2
1
2
2
1
21
LARIUS 2 - painting
English
P
AIR CONTROL GROUP WITHOUT TROLLEY
INOX VERSION
Pos.
Adjustable brackets
Screw
Manometer
Junction
Reg pressure
Ball valve
Bayonet
Fitting elbow
8170
54004
8167
22027
3344
4004
3338
5255
1
2
3
4
5
6
7
8
Codice Descrizione
1
8
2
1
2
1
1
1
9
10
11
12
13
14
15
Pos.
Codice Descrizione
Junction 1/4"
Block air
Junction
Stopper 1/4"
Swivel Elbow
Screw
Nut
96208
8073
3354
8083
8063
8084
11209
1
1
2
1
1
2
2
2
9
8
12
10
11
3
13
5
1
7
4
14
6
8
15
22
LARIUS 2 - painting
English
ALUMINIUM VERSION
Pos.
Reg pressure
Adjustable brackets
Bayonet
Junction 1/4" - Ø4
Vite
Junction
Fitting elbow
3344
8060
3338
8031
32004
3354
5255
1
2
3
4
5
6
7
Codice Descrizione
2
1
1
1
2
2
1
8
9
10
11
12
13
Pos.
Codice Descrizione
Manometer
Junction 1/4"
Stopper 1/4"
Block air
Swivel Elbow
Ball valve
8167
96208
8083
8073
8063
4004
2
1
1
1
1
1
5
7
6
13
3
1
12
2
1
8
6
11
10
4
9
8
23
LARIUS 2 - painting
English
Q
FILTER WITH CIRCULATION
STAINLESS STEEL MODEL
Pos.
Complete filter
Filter tank
Elastic ring
Filter sieve 100 M
Filter sieve support
O ring
Filter base
Fitting
Ball valve
8096
98384
96202
95220
96207
96203
98380
22027
4004
1
2
3
4
5
6
7
8
9
Code Description
1
1
1
1
1
1
1
1
10
11
12
13
14
15
16
17
Pos.
Code Description
Elbow
Revolving fitting
Plug 3/8"
Plug 1/4" GAS
Washer
Elbow
Fitting
Filter fitting
8123
8156
98385
98386
33010
8074
6149
8057
1
1
1
1
1
1
1
1
24
LARIUS 2 - painting
English
ALUMINIUM MODEL
Pos.
Complete filter
Filter tank
Elastic ring
Filter sieve 100 M
Filter sieve support
O ring
Filter base
Fitting
Ball valve
8049
96201
96202
95220
96207
96203
96204
22027
4004
1
2
3
4
5
6
7
8
9
Code Description
1
1
1
1
1
1
1
1
10
11
12
13
14
15
16
17
Pos.
Code Description
Elbow
Revolving fitting
Plug 3/8"
Plug 1/4" GAS
Washer
Elbow
Fitting
Filter fitting
8123
8069
95214
96205
33010
8087
3561
8057
1
1
1
1
1
1
1
1
25
LARIUS 2 - painting
English
R
SUCTION LINE FILTER
COMPLETE SUCTION FILTER
Pos.
Complete filter
Filter tank
Filter sieve 60 M
O ring
Filter base
Plug 1/4" GAS
Revolving fitting
Filter sieve support
Fitting
Ball valve
Elbow
Filter fitting
Washer
Elbow
Fitting
8107
8052
16205
96203
96204
96205
8069
16202
22027
4004
8123
8057
33010
8087
3561
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Code Description
1
1
1
1
1
1
1
1
1
1
1
1
1
1
COMPLETE DROP FILTER
Pos.
Complete filter
Filter tank
Filter sieve 60 M
O ring
Filter base
Plug 1/4" GAS
Revolving fitting
Filter sieve support
Fitting
Ball valve
Elbow
Filter fitting
Washer
Elbow
Fitting
8113
8052
16205
96203
96204
96205
8069
16202
22027
4004
5314
8057/1
33010
8087
3561
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Code Description
1
1
1
1
1
1
1
1
1
1
1
1
1
1
26
LARIUS 2 - painting
English
S
SUCTION TANK MODEL
Pos.
Complete cover
30 Liters tank
Product hose
Filter bell
Fine filter
Coarse filter
Elastic ring
Complete suc ti on p ip e with
filter
4109
4064
8046
35005/1
35006
35007
35008
8041
1
2
4
5
6
7
8
9
Code Description
1
1
1
1
1
1
1
1
27
LARIUS 2 - painting
English
T
WALL-MOUNTED MODEL
Pos.
Wall bracket
1/2" elbow
Suction hose
Bell
Fine sieve filter
Coarse sieve filter
Elastic ring
Complete filter bell
4202
8036
8131
35005
35006
35007
35008
35004
1
2
3
4
5
6
7
8
Codice Description
1
1
1
1
1
1
1
1
28
LARIUS 2 - painting
English
U
V
DESCRIPTION
These safety instructions are related to installation, use and service for use of transfer low pressure double diaphragm pumps – series 2 and 4 – in potentially explosion Hazardous environments due to presence of gas or vapour.
These instructions must be followed as
further precautions to those already listed within the use and service instruction
manual.
TECHNICAL FEATURES
Low pressure transfer double diaphragm pumps series 2 and 4.
1:1
1÷7
1/4" GAS
21
120
The double diaphragm pumps series 2 and 4 are group II equipment, suitable to use in areas classified with iresence of gas and vapour (Category 3G, group IIB). The pumps are designed and manufactured to suit the rules ATEX 94/9/CE and the European Rules: EN 1127-1, EN 13463-1ed EN 13463-5.
SERIE 2 LARIUS
PRESSURE RATIO
PUMP FEEDING AIR PRESSURE
[bar]
PUMP FEEDING AIR INLET
MAX. FLUID DELIVERY
[l/min.]
MAX. AIR CONSUMPTION
[l/min.]
LOW PRESSURE TRANSFER DOUBLE
DIAPHRAGM PUMPS
SERIE 4 LARIUS
1:1
2÷8
1/4" GAS
40
190
Environment temperature: -10°C÷+50°C Max. fluid temperature [°C]: 60°C Max. air temperature [°C]: 30°C
W
MARKING
Low pressure double diaphragm transfer pumps series 2 and 4.
3
X
II 2 G c IIB T4 Tamb: -10°C ÷ + 50°C Tmax. fluido: 60°C Tech. File: LARIUS 2-4/ATEX/05
II =
2 =
G =
c =
T4 =
- 10°C ÷ + 50°C
60°C
xxxxx/AA
Group II ( surface)
Category 2 (zone 1)
Explosion hazardous environment with presence of gas, fog and vapour
Manufacturing safety "c"
Class of temperature T5
Environment temperature
Maximum fluid temperature
Serial number xxxxx = PROGRESSIVE/ year = AA
29
LARIUS 2 - painting
English
Relation between hazardous areas, products and categories
CATEGORIES AS PER RULES
94/9/CE
Gas, vapour or fog
Gas, vapour or fog
Gas, vapour or fog
1G
2G or 1G
3G, 2G or 1G
DANGEROUS AREA
Zone 0
Zone 1
Zone 2
X
SAFETY INSTRUCTIOINS FOR ONSTALLATIONS IN HA­ZARDOUS AREAS
Before proceeding with the installation
carefully read the use and service manual. All the service operations must be carried out as stated in the manual.
The low pressure double diaphragm transfer pumps series 2 and 4 must be connected to the ground with a suitable connector anti-release and anti-rotation.
Gas and vapour of flammable liquids must belong to the group IIB and compatible with class temperature T4.
According with the nature of the operations and products, the operator must regularly check the presence of deposit, the cleaning, the wearing and the correct pump’s functioning.
It is advisable that a filter will be placed at the suction of the material to prevent solid parts entering the pump.
The pipes used to connect suction and delivery must be metallic, or plastic with metallic braid or plastic with fabric braid with suitable earthing cable.
According to duties it is recommended the control of dia­phragms and replacement.
The air feeling the pump needs to be filtered and originated by a safe area.
The low pressure double diaphragm
transfer pumps series 2 and 4 must not work empty of material.
All the operations, installation and service,
must be carried out by qualified operators.
Y
EXAMPLE OF INSTALLATION
The picture shows a typical example of installation of a Larius double diaphragm pump.
30
LARIUS 2 - painting
English
DECLARATION OF CONFORMITY
We Larius S.r.l. Via Stoppani, 21 24032 Calolziocorte (LC)
declare under our sole responsibility that the pro­duct
Low pressure transfer double diaphragm pum­ps - series 2 and 4.
to which this declaration relates complies with the following Directives:
- Directive 94/9/EC (ATEX)
3
X
The conformity are under observance of the fol­lowing standards or standards documents:
- EN 1127-1 - EN 13463-5
- EN 13463-1
Marking
II 2 G c IIB T4 Tamb.: - 10°C ÷ 50°C Tmax. fluido: 60°C
Tech. File: LARIUS 2-4/ATEX
Technical file c/o: INERIS (0080)
Calolziocorte- LC Signature
A C C E S S O R
I E S
Code 55007:
6LT DROP TANK
Code 7208: STAINLESS STEEL 0-14 BAR RETURN REGULATOR
Code 14090: SPRAY GUN V71P Code 14132: NOZZLE 0,8 mm Code 14092: NOZZLE 1,0 mm Code 14090: NOZZLE 1,3 mm Code 14096: NOZZLE 1,5 mm Code 14134: NOZZLE 1,8 mm
Code 7185: FLOW REGULATOR
Code 8131: SUCTION RETURN SYSTEM Code 8144: SUCTION RETURN SYSTEM (stainless steel)
SUCTION BELL KIT
Code 35004: FILTER BELL - Code 35006: FILTER 100 MESH Code 35007: FILTER 50 MESH - Code 35007/1: FILTER 30 MESH
Code 8107: SUCTION LINE FILTER Code 8113: DROP LINE FILTER
Code 16205: FILTER SIEVE 60 MESH Code 16204: FILTER SIEVE 100 MESH Code 16203: FILTER SIEVE 200 MESH Code 16205/10: FILTER SIEVE 60 MESH 10 pcs Code 16204/10: FILTER SIEVE 100 MESH 10 pcs Code 16203/10: FILTER SIEVE 200 MESH 10 pcs
LINEA DIRETTA
SERVIZIO TECNICO CLIENTI
Tel. (39) 0341.621256 - Fax (39) 0341.621234
P A I N T S P R A Y I N G E Q U I P M E N T
COSTRUTTORE:
23801 CALOLZIOCORTE - LECCO - ITALY - Via Antonio Stoppani, 21 Tel. (39) 034 1/6 2.11.52 - Fax (39 ) 0341 /62. 12. 43 E-mai l : lariu s @ l ar ius.c o m - I n ternet http : / / www. larius. c o m
33
LARIUS 2 - painting
English
34
LARIUS 2 - painting
English
Due to a constant product improvement programme, the factory reserves the right to modify
technical details mentioned in this manual without prior notice.
23801 CALOLZIOCORTE - LECCO - ITALY - Via Stoppani, 21 Tel . (39) 0341/62.11. 52 - Fax (39) 0341/ 62. 12.43 E-mail: larius@larius.com - Internet http://www.larius.com
NOVA Ref. 95040 OMEGA Ref. 7300
OMEGA ZINC Ref. 7430 GHIBLI ZINC Ref. 96900
VEGA Ref. 91500GHIBLI Ref. 96000
MANUFACTURER:
DIRECT LINE
Tel. (39) 0341/621256 Fax (39) 0341/621234
CUSTOMERS TECHNICAL SERVICE
PNEUMATIC PUMPS
Loading...