Larco U-WAV User Manual

U-WAV Touchless Sensing Solution
Installation and Mounting Instructions
The U-WAV is a sensor switch designed for touchless activation of automatic doors, lighting controls, or call points. Ideal for sterile environments such as operating rooms or clean rooms, the U-WAV provides a complete hygienic solution for various applications.
Description
Microwave Sensor
Bevel Plate (Optional)
Toggle (T) or Pulse (P)
Sensitivity
Normally Open Normally Closed Relay Common
Power12-24VAC or 12-30VDC
Cover Plate
Sensor Mounting Plate
U-WAV technical Specifications
Technology K-Band Microwave Relay Output Ratings 125VAC, 60VDC @ 1A
Radiated Frequency 24.117GHz Current Consumption < 1.4W
Detection Range 0 - 15.0 in Temperature Range -4 - 140 F
Detection Mode Motion (bi-directional) Relative Humidity up to 90%, Non-condensing
Operation Mode
Toggle Activate On, Activate Off Weight
Pulse Activates for 1.2 Seconds LED Color
< 3 oz
Blue
Supply Voltage 12-24VAC, 12 - 30VDC Available Colors Grey, Black, White
www.larco.com
Installation and Mounting Instructions
1 2
Snap sensor board assembly onto mounting plate with microwave sensor facing mounting plate.
P: Relay
T: Relay
3 4
If using surface mount bevel, run wiring through bevel before making connections to terminal block.
Choose desired mode of operation, toggle (T) or pulse (P) with selector switch.
Detect Detect
1.2 sec
Adjust distance sensitivity before attaching assembly to mounting surface. Turn clockwise for more sensitivity and greater sensing distance.
5 6
Surface mount bevel is optional.
Attach assembly to mounting surface with screws supplied.
FCC ID: USX-IPM165F This devise complies with part 15 of the FCC rules. Operation is subject to the following two conditions. (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to correct the interference by one or more of the following measures. Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Increase the separation between the equipment and receiver. Consult the dealer or experienced radio/ TV technician for help.
The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the users authority to operate this equipment.
ATEK Access Technologies
10025 Valley View Road, Ste. 190 Eden Prairie, MN 55344 U.S.A.
PH: 1.800.523.6996 FAX: 1.800.589.3705 +1.218.829.9797
www.atekaccess.com
Snap cover in position to conceal mounting screws.
Aer initializing power to unit, blue LED lights are ON when idle and OFF during activation.
223-0114-000 Rev. D 2/15