Larcan T2500U User Manual

Installation
- 1 -
Installation
1. Installation:
1.1. Unpacking:
1.2. Repacking and Transportation:
If it is necessary the equipment be sent back to the company or any distant place, some
precaution must be considered:
Wrap the equipment with air bubble plastic. Do not let any part of the equipment exposed to
protect it against any damage to the equipment painting;
Wrap the equipment with cardboard and wood pack it to protect against any impact;
Ensure that anything was left loose inside the package. Put the package stood to avoid any
impact.
1.3. Installation Requirement:
Installation Site: The equipment should not be installed in places that exceeds 2000 meters
of altitude; have a proper air conditioning system (if it is necessary), voltage regulator, ventilation air conducting; ensure that sufficient space around the equipment is available to permit easy access, and to enhance future ease of maintenance. It is recommended a minimum 0.5m of clearance both right and left sides, and 1.0m both front and rear of the equipment; the ceiling should have at least 3.0m of height where the blower exhaust will be installed. The place must be free of dirt, humidity and dust.
Installation Surface: For small equipment, it is recommended being installed on a table or
a standard rack 19”, which it should have at least 0.3m of clearance from the wall in order to have a proper ventilation.
Power board: It is necessary a power board to organize, separate, and distribute the power
supply and mainly for equipment protection. The power board is connected to the power line. Thermomagnetic disjunctor must be used in order to feed isolatedly the equipment, illumination, air conditional, blower exhaust, etc.
Voltage Regulator: A voltage regulator is used for protection against any variation and
transient coming from the power line so that it will provide a better performance of your equipment. The regulator should provide at least 30% more power than the equipment consumes. It is recommended using an electronic kind regulator, microprocessed, with a perfect senoidal output, and an isolator transformer for the entrance.
Grounding: All the equipments must be connected to the main station ground system but
isolated from the wall, protecting it against electrostatic discharges, lightning strikes, etc. Grounding should be 5 Ohms maximum to have an adequate protection. Ensure that the following items are connected to the main ground system:
Tower base;
Lightning rod;
Neutral wire;
Power supply ground;
All the equipment grounds such as power board, voltage regulator, etc;
Broadcast Antennas, coaxial cable and transmission line.
If you have any doubts about the station ground system quality, a specialized company should be contacted.
- 2 -