Lantronix Xpress-Pro SW 52000 User Manual

XPress-Pro SW 52000
User Guide
Part Number 900-509
Revision A May 2007
© 2005, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix. Printed in the United States of America.
Ethernet is a trademark of XEROX Corporation. UNIX is a registered trademark of The Open Group. Windows 95, Windows 98, Windows 2000, and Windows NT are trademarks of Microsoft Corp. Netscape is a trademark of Netscape Communications Corporation.
Contacts
Lantronix Corporate Headquarters
15353 Barranca Parkway Irvine, CA 92618, USA Phone: 949-453-3990 Fax: 949-453-3995
Technical Support Online: www.lantronix.com/support
Sales Offices For a current list of our domestic and international sales offices, go to the Lantronix web site at www.lantronix.com/about/contact
.
XPress-Pro SW 52000 User Guide 3
Contents
1: Preface 5
Plug-and-Play Solution _______________________________________________ 5
2: Product Overview 6
Hardened Compact Switch ____________________________________________ 6
Package Contents ___________________________________________________ 6
Product Highlights ___________________________________________________ 7
Front Panel Display __________________________________________________ 7
Physical Ports ______________________________________________________ 8
cPower Status (PWR)____________________________________________________ 8
dPort Status LEDs_______________________________________________________ 8
Connectivity ____________________________________________________________ 8
3: Installation 9
Selecting a Site for the Switch __________________________________________ 9
DIN Rail Mounting ___________________________________________________ 9
Connecting to Power ________________________________________________ 10
DC Terminal Block Power Inputs ___________________________________________ 10
Connecting to Your Network __________________________________________ 11
Cable Type & Length ____________________________________________________ 11
Cabling _______________________________________________________________ 11
A: Specifications and Standards 12
B: Connector Pinouts 13
XPress-Pro SW 52000 User Guide 4
1: Preface
A member of the growing family of rugged switches, this switch addresses a need for a smaller switch. This switch provides an affordable solution for rugged and outdoor environment, transportation road-side cabinet, industrial floor shop, multitenant dwellings or Fiber To The Home (FTTH) applications. Capable of operating at
temperature extremes of -10°C to +60°C, this is the switch of choice for harsh environments constrained by space.
Plug-and-Play Solution
The switch is a plug-and-play Fast Ethernet Switch in compact size. It doesn't have any complicated software to set up.
This manual describes how to install and use the hardened compact Ethernet Switch. This switch integrates full wire speed switching technology. This switch brings the answer to complicated hardened networking environments.
To get the most out of this manual, you should have an understanding of Ethernet networking concepts.
In this manual, you will find:
Features on the switch
Illustrative LED functions
Installation instructions
Specifications
XPress-Pro SW 52000 User Guide 5
2: Product Overview
Hardened Compact Switch
Package Contents
When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.
This Switch
User’s Manual
XPress-Pro SW 52000 User Guide 6
Product Highlights
Basic Features
5-port 10/100Base-TX or 4-port 10/100Base-TX plus 1-port 100Base-FX.
Available in media converter format with 1-port 10/100Base-TX and 1-port
100Base-FX.
Support IEEE802.3/802.3u/802.3X.
Auto-negotiation: 10/100Mbps, Full/half-duplex; Auto MDI/MDIX.
Support 2K MAC addresses.
Store-and-forward mechanism.
Full wire-speed forwarding rate and non-blocking mechanism.
Broadcast storm filtering.
Operating voltage and Max. current consumption: 12VDC @ 0.71A, 24VDC @
0.37A, 48VDC @ 0.22A.
2: Product Overview
Power consumption: 10.56W Max.
Power Supply: DC Terminal Block power input, 10-48VDC with polarity
protection.
Plastic compact DIN-Rail Industrial case design.
DIN-Rail mounting ability.
Front Panel Display
XPress-Pro SW 52000 User Guide 7
2: Product Overview
cPower Status (PWR)
This LED comes on when the switch is properly connected to power and turned on.
dPort Status LEDs
The LEDs display status for each respective port.
LED State Indication
10/100TX or 100FX
LNK/ACT
(Green)
100
(Yellow)
Physical Ports
This switch provides:
Five 10/100BaseTX ports
Four 10/100BaseTX ports + one 100BaseFX port
One 10/100BaseTX port + one 100BaseFX port
Connectivity
RJ-45 connectors
SC or ST connecto on 100BaseFX fiber port.
Steady
Flashing
Steady
Off
A valid network connection established. LNK stands for LINK.
Transmitting or receiving data. ACT stands for ACTIVITY.
Light solid yellow for a port transferring at 100Mbps. The port is transferring at 10Mbps If this LED is dark.
XPress-Pro SW 52000 User Guide 8
3: Installation
This chapter gives step-by-step instructions about how to install the switch:
Selecting a Site for the Switch
As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
The ambient temperature should be between -10 to 60 degrees Celsius.
The relative humidity should be less than 90 percent, non-condensing.
Surrounding electrical devices should not exceed the electromagnetic field
(RFC) standards.
Make sure that the switch receives adequate ventilation. Do not block the
ventilation holes on each side of the switch
The power outlet should be within 1.8 meters of the switch.
DIN Rail Mounting
Installation: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the switch from the DIN rail.
XPress-Pro SW 52000 User Guide 9
3: Installation
Connecting to Power
DC Terminal Block Power Inputs
1. Connect the DC power cord to the plug-able terminal block on the switch, and then plug it into a standard DC outlet.
2. Disconnect the power cord if you want to shut down the switch.
XPress-Pro SW 52000 User Guide 10
The Terminal Block
PWR Power Input GND Power Ground
Earth Ground
Connecting to Your Network
Cable Type & Length
It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.
3: Installation
Speed Connector Port Speed
Half/Full Duplex
10BaseT RJ-45 10/20 Mbps 2-pair UTP/STP Cat. 3, 4, 5 100 m 100BaseTX RJ-45 100/200 Mbps 2-pair UTP/STP Cat. 5 100 m 100BaseFX SC, ST 100/200 Mbps MMF (50 or 62.5µm) 2 km 100BaseFX SC, ST 100/200 Mbps SMF (9 or 10µm) 15, 40, or 75 km
Cable Max.
Distance
Cabling
1. First, ensure the power of the switch and end devices is turned off.
2. Always ensure that the power is off before any installation.
3. Prepare cable with corresponding connectors for each type of port in use.
4. To connect two regular RJ-45 ports between switches or hubs, you need a cross­over cable.
5. Consult the previous section for cabling requirements based on connectors and speed.
6. Connect one end of the cable to the switch and the other end to a desired device.
Once the connections between two end devices are made successfully, turn on the power and the switch is operational.
XPress-Pro SW 52000 User Guide 11
A: Specifications and Standards
Table Specification
Hardened Compact Switch Applicable Standards IEEE 802.3 10BaseT
Switching Method Store-and-Forward Forwarding Rate 10BaseT: 100BaseTX/FX: Performance 148,80pps for 10Mbps
Cable 10BaseT: 100BaseTX:
100BaseFX: LED Indicators Per unit – Power status (PWR)
Dimensions W26mm × D70mm × H110mm Compact Size Net Weight 0.2kg approx. Power Terminal Block: 10-48VDC Operating Voltage & Max. Current Consumption Power Consumption 10.56W max. Operating Temperature -10°C to 60° C Storage Temperature -25°C to 85°C Humidity 10%-90% non-condensing Safety UL/CUL 60950, EN60950, IEC 60950,
Emissions FCC Class A, CE Class A
Standards
ESD Standard (IEC 61000-4-2) Radiated FRI Standards (IEC 61000-4-3) Burst Standards (IEC 61000-4-4) Surge Standards (IEC 61000-4-5) Induced (Conducted) RFE Standards (IEC 61000-4-6) Magnetic Field Standards (IEC 61000-4-8) Voltage Dips Standards (IEC 61000-4-11) Environmental Test Standards: Vibration Resistance (IEC 60068-2-6) Shock (IEC 60068-2-27) Free Fall (IEC 60068-2-32)
10/100BaseT/TX auto-negotiating ports with RJ-45 connectors, 100BaseFX fiber ports
IEEE 802.3u 100BaseTX/FX
10 / 20Mbps half / full-duplex 100 / 200Mbps half / full-duplex
148,800pps for 100Mbps
2-pair UTP/STP Cat. 3, 4, 5 2-pair UTP/STP Cat. 5 Up to 100m (328ft) MMF (50 or 62.5µm), SMF (9 or10µm)
Per port – LNK/ACT – (Green) 10/100TX or 100FX 100 – (Yellow) 10/100TX or 100FX
12VDC @ 0.71A, 24VDC @ 0.37A, 48VDC @ 0.22A
IEC61000-6-2
XPress-Pro SW 52000 User Guide 12
B: Connector Pinouts
Pin Arrangement of RJ45 Connectors:
The following table lists the pinout of 10/100BaseT/TX ports.
Pin Regular Ports Uplink port
1 Input Receive Data + Output Transmit Data + 2 Input Receive Data - Output Transmit Data ­3 Output Transmit Data + Input Receive Data +
4 NC NC 5 NC NC 6 Output Transmit Data - Input Receive Data -
7 NC NC 8 NC NC
XPress-Pro SW 52000 User Guide 13
Loading...