Lantronix XPress-DR Plus Quick Start Manual

Page 1
2006 Copyright © Lantronix is a trademark of Lantronix. All rights reserved. 900-428 Rev. A 03/06
XPress-DR+ Quick Start Guide
XPress-DR+ Industrial Device Server
Page 2
XPRESS-DR+ QUICK START CONTENTS
What’s In the Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Quick Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
Assigning IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9
DeviceInstaller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-12
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
XPress-DR+ Industrial Device Server
Page 3
Quick Start Guide
XPress-DR+
PINOUTS
The XPress-DR+ supports RS-232 via RJ45 connectors.It also supports RS-422/485 via screw terminals (Serial Port 2 only).
Note: Serial Port 2 supports RS232,RS422,and RS485,but only one mode at a time.
This means you can use either the RJ45 connector or the terminal block,not both.
The serial RJ45 serial connectors support RS232,up to 230,400 bits per second.
The supplied Lantronix P/N:500-103 serial cable can be used to connect port 1 of XPress-DR+ to a PC’s com port for configuration using a terminal emulation application.Refer to the XPress-DR+ Users Guide for information on configuring the XPress-DR+ thought the serial interface.
2
WWW.LANTRONIX.COM
3
WHAT’S IN THE BOX
Verify and inspect the contents of the package using the enclosed packing slip or the list below. I f any item is missing or damaged,contact your place of purchase immediately.
XPress-DR+
CD (with protocols,utilities,and User Guide)
Quick Start Guide
P/N:500-103 RJ45-DB9F serial cable
Accessory Din-rail wall mount bracket
3 terminal screw connector for power input
5 terminal screw connector for serial port
The user must supply a 9-30 VDC or 9-24 VAC power source and a CAT 5 Ethernet cable.
OVERVIEW
The XPress-DR+ industrial automation device server provides a quick and easy method to network-enable multiple industrial automation devices and equipment.The embedded Ethernet switch and multiple serial ports enable real-time access for remote configuring, programming,monitoring, and control of PLCs, motor drives, process controls, p ower monitoring equipment,barcode scanners,or virtually any RS232,RS422,or RS485 factory floor device.
RJ45 Serial Connector Pinouts
Page 4
4
WWW.LANTRONIX.COM
Quick Start Guide
XPress-DR+
5
PINOUTS CONTINUED… PINOUTS CONTINUED
Note:Termination resistors (R = 120 Ohm) are used to match impedance of a node to
the impedance of the transmission (TX) line.Termination resistors should be placed only at the extreme ends of the TX data lines,and no more than two terminations should be placed in any single segment of an RS-485 network.The terminator resistors may not be needed for your application.
9-Pin RS-232 to Serial RJ45
The included Lantronix P/N (500-103) RJ45-DB9F serial cable assumes you are connecting a typical PC Com port to the XPress-DR+ serial port.This cable is pinned to provide full serial line control to an RS232 DTE device. Lantronix offers a comprehensive list of cables and adapters to simplify device connectivity to the XPress-DR+.See the User Guide for a full listing.
Screw Terminal Serial Connectors
Serial Screw Terminal Pinout for RS422 (4-Wire)
Serial Screw Terminal Pinout for RS485 (2-Wire)
Serial Screw Terminal Pinout for RS485 (2-Wire)
9-Pin RS-232 to Serial RJ45 Pinout Table
Page 5
6
WWW.LANTRONIX.COM
Quick Start Guide
XPress-DR+
7
QUICK CONNECT CONTINUED
Typical Installation
QUICK CONNECT
Warning:Connecting a device to an active Ethernet network can disrupt
communications on the network.Make sure the device is configured for your application before connecting it to an active network.
1. Connect a serial device to your XPress-DR+.
2. Connect an Ethernet cable to the Ethernet port.
3. Supply power to your XPress-DR+ using a 9-30 VDC or 9-24 VAC (2.3 W maximum) source.
4. Supply power to the serial device.
5. Verify that the green Link LED is lit.
Page 6
8
Quick Start Guide
XPress-DR+
WWW.LANTRONIX.COM
9
ASSIGNING AN IP ADDRESS CONTINUED
Fixed IP Address
In most installations,a fixed IP address is desirable.The systems administrator generally provides the IP address,subnet mask,and gateway.
The IP address must be within a valid range, unique to your network, and in the same subnet as your PC. You will need the following information before you set up the unit as described in DeviceInstaller,below.
IP Address: _______ _______ _______ _______
Subnet Mask: _______ _______ _______ _______
Gateway: _______ _______ _______ _______
You have several options for assigning an IP to your XPress-DR+.We recommend that you connect the unit to the network and assign the IP address using DeviceInstaller software,which is on the product CD.For information on other methods,see the XPress-DR+ User Guide.
ASSIGNING AN IP ADDRESS
Your unit must have a unique IP address on your network.Two ways to assign an IP address are described below. Additional methods of assigning an IP Address and configuring the XPress-DR+ are described in the Users Guide.
DHCP
Many networks use an automatic method of assigning an IP address called DHCP. If you are unsure whether your network uses DHCP, check with your systems administrator.
The XPress-DR+ looks for a DHCP server when it first powers up.The unit has acquired an IP address if the red LED stops flashing and the green Status LED is on continuously.You can use the DeviceInstaller software (see below) to search the network for the IP your unit has been assigned by the DHCP server and add the unit to the list of Lantronix devices on the network.
If the unit does not acquire an IP address,or you do not use DHCP,you must assign a fixed IP address.
Note:The unit’s IP address is set to 0.0.0.0 at the factory. The unit is DHCP– enabled as
the default.
Page 7
10
Quick Start Guide
XPress-DR+
WWW.LANTRONIX.COM
11
DEVICEINSTALLER CONTINUED…
5. Enter the IP address.The Subnet mask displays automatically based on the IP address;if desired,you may change it.On a local network,you can leave the Default gateway blank (all zeros). Click Next.
6. Click the Assign button and wait several seconds until a confirmation message displays.Click Finish.
7. Select the device from the main window list and select Ping from the Tools menu. The Ping Device dialog box shows the IP address of the selected unit.
8. Click the Ping button. The results display in the Status window.Click the Clear Status button to clear the window so you can ping the device again.
Note: If you do not receive "Reply" messages, make sure the unit is properly
attached to the network and that the IP address assigned is valid for the particular network segment you are working with.If you are not sure,check with your systems administrator.
9.Click the Close button to close the dialog box and return to the main window.
DEVICEINSTALLER
Step 1:Install DeviceInstaller
To use the DeviceInstaller utility,first install it from the product CD.
1. Insert the product CD into your CD-ROM drive.
2. If the CD does not launch automatically: a.Click the Start button on the Task Bar and select Run. b.Enter your CD drive letter,colon,backslash,Launch.exe (e.g.,D:\Launch.exe).
3. Click the DeviceInstaller button.
4. Respond to the installation wizard prompts.(When prompted to select an
installation type,select Typical.)
Note: For more information about DeviceInstaller,see the DeviceInstaller online Help.
Step 2:Configure Network Settings
To assign an IP address manually:
1. Click Start Programs Lantronix DeviceInstaller DeviceInstaller.
If your PC has more than one network adapter,a message displays. Select an adapter and click OK.
Note: If the unit already has an IP address (e.g.,DHCP has assigned an IP address),
click the Search icon and select the unit from the list of Lantronix device ser vers on the local network.
2. Click the Assign IP icon .
3. If prompted,enter the hardware address (on the product label) and click Next.
4. Select Assign a specific IP address and click Next.
Page 8
12
LEDS
CONTACT
For questions and technical support,please check our online knowledge base at www.lantronix.com/support
Lantronix 15353 Barranca Parkway,Ir vine, CA 92618,USA Phone:(949) 453-3990 or Fax:(949) 453-3995
www.lantronix.com
WWW.LANTRONIX.COM
13
Quick Start Guide
XPress-DR+
DEVICEINSTALLER CONTINUED
Step 3:Add the Unit to the Device List
Now add the unit to the list of similar Lantronix devices on the network so that you can manage and configure it. To perform this step,click the Search icon . DeviceInstaller locates the unit and adds it to the list.
Step 4:Complete the Configuration
Once the unit is in the device list,you can complete the configuration.
To use a web interface (Web Manager), double-click the unit in the list and
click the Web Configurationtab.
To use Setup Mode (a command line interface),double-click the unit in the
list and click the Telnet Configuration tab.
Note: Please see the XPress-DR+ User Guide for detailed instructions
on configuration.
Upgrade the Firmware
To upgrade firmware or install other protocols such as ModBus refer to the XPress-DR+ Users Guide or the DeviceInstaller online help.
Loading...