Lantech IGS-3208MGSFP, IPGS-3208MGSFP, IGS-3208C, IPGS-3208C, IGS-3204MGSFP User Manual

...
I(P)GS-3208MGSFP
I(P)GS-3208C
I(P)GS-3204MGSFP
I(P)GS-3008
IP30-rated Series
IP30-rated L2+ Industrial Managed Switch w/Enhanced G.8032 Ring
User Manual (Hardware)
Mar. 2017
Recommendation for Shielded network cables
STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable. It is also mandatory to use an STP cable where the power device (like IP camera) is used outdoors or where the network cable is routed outdoors.
Important Notice
Lantech Communications Global, Inc. reserves the right to modify the equipment, its specification or this manual without prior notice, in the interest of improving performance, reliability, or servicing. At the time of publication all data is correct for the operation of the equipment at the voltage and/or temperature referred to. Performance data indicates typical values related to the particular product.
No part of this documentation or information supplied may be divulged to any third party without the express written consent of Lantech Communications Global Inc. Products offered may contain software which is proprietary to Lantech Communications Global Inc. The offer or supply of these products and services does not include or infer any transfer of ownership.
Interference Issues
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a commercial or industrial installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions.
FCC Warning
This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Content
Chapter 1 Model List ................................................ 1
Chapter 2 Hardware Description ............................ 2
2.1 IP Protection ................................................... 2
2.2 LED Indicators................................................ 5
Chapter 3 Hardware Installation ............................. 7
3.1Hardware installation .......................................... 7
3.2 DIN-Rail Mounting .......................................... 8
3.3 Wall Mount Plate Mounting .......................... 10
3.4 Wiring the Power Inputs ............................... 11
3.5 Wiring the Fault Alarm Contact .................... 12
3.6 Cabling ......................................................... 13
Chapter 4 Network Application ............................. 16
ITU G.8032 Scheme .............................................. 16
Ring Coupling ........................................................... 16
Multiple Rings .......................................................... 17
Dual Homing ............................................................ 18
Chain ....................................................................... 18
Chapter 5 Console Management .......................... 20
5.1 Connecting to the Console Port ................... 20
5.2 Login in the Console Interface ..................... 21
1
Chapter 1 Model List
Model Name
10/100/1000T Port
1G/2.5G SFP Port
10/100/1000T/ 100M/1000M SFP Combo Port
USB Port IPGS­3208MGSFP
8 with PoE at/af
2 1
IGS­3208MGSFP
8 2
1
IPGS-3208C
8 with PoE at/af
2 1
IGS-3208C
8 2
1
IPGS­3204MGSFP
4 with PoE at/af
2 1
IGS­3204MGSFP
4 2
1
IPGS-3008
8 with PoE at/af
IGS-3008
8
IP30 rated  L2+ managed  Enhanced G.8032 Ring
*For detail specifications, please refer to product datasheet. **The revise authority rights of product specifications belong to Lantech Communications Global, Inc. Lantech may make changes to specification and product descriptions at anytime, without notice.
2
Chapter 2 Hardware Description
In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling
information, and wiring installation.
2.1 IP Protection
The IP Code, Ingress Protection Rating, sometimes also interpreted as International Protection Rating, classifies and rates the degree of protection provided against the
intrusion (including body parts such as hands and fingers), dust, accidental contact, and water in mechanical casings and with electrical enclosures. It is published by the International Electrotechnical Commission (IEC)
Solid particle protection
The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects.
Level
Object size
protected against
Effective against
0
No protection against contact and ingress of objects
1
>50 mm
Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part
2
>12.5 mm
Fingers or similar objects
3
>2.5 mm
Tools, thick wires, etc.
4
>1 mm
Most wires, screws, etc.
5
Dust protected
Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete
3
protection against contact
6
Dust tight
No ingress of dust; complete protection against contact
Liquid ingress protection
The second digit indicates the level of protection that the enclosure provides against harmful ingress of water.
Level
Protected
against
Testing for
Details
0
Not protected
1
Dripping water
Dripping water (vertically falling drops) shall have no harmful effect.
Test duration: 10 minutes Water equivalent to 1 mm rainfall per minute
2
Dripping water when tilted up to 15°
Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15° from its normal position.
Test duration: 10 minutes Water equivalent to 3 mm rainfall per minute
3
Spraying water
Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect.
Test duration: 5 minutes Water volume: 0.7 litres per minute Pressure: 80–100 kPa
4
Splashing of water
Water splashing against the enclosure from any direction shall have no harmful effect.
Test duration: 5 minutes Water volume: 10 litres per minute Pressure: 80–100 kPa
4
5
Water jets
Water projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects.
Test duration: at least 15 minutes Water volume: 12.5 litres per minute Pressure: 30 kPa at distance of 3 m
6
Powerful water jets
Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects.
Test duration: at least 3 minutes Water volume: 100 litres per minute Pressure: 100 kPa at distance of 3 m
7
Immersion up to 1 m
Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion).
Test duration: 30 minutes Immersion at depth of at least 1 m measured at bottom of device, and at least 15 cm measured at top of device
8
Immersion beyond 1 m
The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that
Test duration: continuous immersion in water Depth specified by manufacturer