Lantech IPES-0005B, IES-0005B, IPES-0008B, IES-0008B User Manual

IPES/IES-0005B/0008B Series
5/8 10/100TX (w/8/5 PoE at/af) Industrial Un-Managed Switch
User Manual
Aug. 2016
Recommendation for Shielded network cables
STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable. It is also mandatory to use an STP cable where the power device (like IP camera) is used outdoors or where the network cable is routed outdoors.
Important Notice
Lantech Communications Global, Inc. reserves the right to modify the equipment, its specification or this manual without prior notice, in the interest of improving performance, reliability, or servicing. At the time of publication all data is correct for the operation of the equipment at the voltage and/or temperature referred to. Performance data indicates typical values related to the particular product.
No part of this documentation or information supplied may be divulged to any third party without the express written consent of Lantech Communications Global Inc. Products offered may contain software which is proprietary to Lantech Communications Global Inc. The offer or supply of these products and services does not include or infer any transfer of ownership.
Interference Issues
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a commercial or industrial installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions.
FCC Warning
This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Content
Chapter 1 Introduction ............................................. 5
Specification ............................................................. 5
Chapter 2 Hardware Description ............................ 7
2.1 Physical Dimension ........................................ 7
2.2 Package Content:........................................... 8
2.3 IP Protection ................................................... 9
2.4 LED Indicators.............................................. 12
Chapter 3 Hardware Installation ........................... 13
5
Chapter 1 Introduction
Lantech IPES/IES-0005B/0008B Series is a high performance IP41 industrial switch with 8/5 x10/100TX (w/8/5 PoE at/af injectors - IPES model) by M12 connectors which provides L2 wire speed and advanced security function for connecting PD network.
Specification
For latest product specifications, please refer to Lantech official site.
IES/IPES-0005B series
Hardware Specification
IEEE Standard
IEEE802.3 10BASE-T Ethernet IEEE802.3u 100BASE-T Ethernet IEEE802.3x Flow Control and Back Pressure IEEE802.3at/af Power over Ethernet
Transfer Rate
14,880pps for Ethernet port 148,800pps for Fast Ethernet port
Mac Address
8K MAC address table
Connector
10/100T: 5 x M12, 4-pole D-coded, Female with auto MDI/MDI-X function Power connector: 1 x M12, 5-pole A-coded, Male
Protocol
CSMA/CD
LED
Per unit: Power 1 (Green), Power 2 (Green), Ethernet: Link/Activity (Green)
PoE Pin Assignme nt
RJ-45 port # 1~#5 support IEEE 802.3af/at End-point, Alternative A mode. Per port provides 15.4W/30W ability. Positive (VCC+): RJ-45 pin 1,2. Negative (VCC-): RJ-45 pin 3,6.
Power Supply
Dual input
9.5~56VDC for PoE feeding (12V model)
50.4~90VDC for PoE feeding (72V model)
Power Consumpti on
10W for 12/24/48VDC
13.5W for 72V
Power Budget
80W for 12V input 120W for 24V input
80W for 72V Input
Operating Humidity
5% to 95% (Non-condensing)
Operating Temperatu re
-40°C ~ 75°C (-40°F ~ 167°F)
Storage Temperatu re
-40°C ~ 85°C (-40°F ~ 185°F)
Case Dimension
Aluminum case, IP-41 135mm(W)x165mm(H)x62mm(D)
Weight
700g
Installation
Din Rail**, Wall Mount Design
EMC
FCC Class A, CE EN61000-4-2 (ESD), CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT), CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS), CE EN61000-4-8 (Magnetic Field), CE EN61000-6-2,
6
CE EN61000-6-4
Stability Testing
IEC61373 (Shock), EN61373 (Shock and Vibration)
Certificate s & Report
EN50155/EN50121-3-2/EN50121-4 Certificate EN45545-2 R24 (EN ISO 4589-2, EN ISO 5659-2, NF X70-100-1 & 2) Fire & Smoke Certificate
Warranty
5 years
**Optional
IES/IPES-0008B series
Hardware Specification
IEEE Standard
IEEE802.3 10BASE-T Ethernet IEEE802.3u 100BASE-T Ethernet IEEE802.3x Flow Control and Back Pressure IEEE802.3at/af Power over Ethernet
Transfer Rate
14,880pps for Ethernet port 148,800pps for Fast Ethernet port
Mac Address
8K MAC address table
Connector
10/100T: 8 x M12, 4-pole D-coded, Female with auto MDI/MDI-X function Power connector: 1 x M12, 5-pole A-coded, Male
Protocol
CSMA/CD
LED
Per unit: Power 1 (Green), Power 2 (Green), Ethernet: Link/Activity (Green)
PoE Pin Assignment
RJ-45 port # 1~#8 support IEEE 802.3af/at End-point, Alternative A mode. Per port provides 15.4W/30W ability. Positive (VCC+): RJ-45 pin 1,2. Negative (VCC-): RJ-45 pin 3,6.
Power Supply
Dual input
9.5~56VDC for PoE feeding (12V model)
50.4~90VDC for PoE feeding (72V model)
Power Consumption
10W for 12/24/48VDC
13.5W for 72V
Power Budget
80W for 12V input 120W for 24V input 80W for 72V Input
Operating Humidity
5% to 95% (Non-condensing)
Operating Temperature
-40°C ~ 75°C (-40°F ~ 167°F)
Storage Temperature
-40°C ~ 85°C (-40°F ~ 185°F)
Case Dimension
Aluminum case, IP-41 135mm(W)x165mm(H)x62mm(D)
Weight
700g
Installation
Din Rail**, Wall Mount Design
EMC
FCC Class A, CE EN61000-4-2 (ESD), CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT), CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS), CE EN61000-4-8 (Magnetic Field), CE EN61000-6-2, CE EN61000-6-4
Stability Testing
IEC61373 (Shock), EN61373 (Shock and Vibration)
Certificates & Report
EN50155/EN50121-3-2/EN50121-4 Certificate EN45545-2 R24 (EN ISO 4589-2, EN ISO 5659-2, NF X70-100-1 & 2) Fire & Smoke Certificate
Warranty
5 years
**Optional
7
Chapter 2 Hardware Description
In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation.
2.1 Physical Dimension
Aluminum case. IP-41,
8
2.2 Package Content:
Manual CD* Product
*By request
9
2.3 IP Protection
The IP Code, Ingress Protection Rating, sometimes also interpreted as International Protection Rating, classifies and rates the degree of protection provided against the
intrusion (including body parts such as hands and fingers), dust, accidental contact, and water in mechanical casings and with electrical enclosures. It is published by the International Electrotechnical Commission (IEC)
Solid particle protection
The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects.
Level
Object size
protected against
Effective against
0
No protection against contact and ingress of objects
1
>50 mm
Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part
2
>12.5 mm
Fingers or similar objects
3
>2.5 mm
Tools, thick wires, etc.
4
>1 mm
Most wires, screws, etc.
5
Dust protected
Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact
6
Dust tight
No ingress of dust; complete protection against contact
10
Liquid ingress protection
The second digit indicates the level of protection that the enclosure provides against harmful ingress of water.
Level
Protected
against
Testing for
Details
0
Not protected
1
Dripping water
Dripping water (vertically falling drops) shall have no harmful effect.
Test duration: 10 minutes Water equivalent to 1 mm rainfall per minute
2
Dripping water when tilted up to 15°
Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15° from its normal position.
Test duration: 10 minutes Water equivalent to 3 mm rainfall per minute
3
Spraying water
Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect.
Test duration: 5 minutes Water volume: 0.7 litres per minute Pressure: 80–100 kPa
4
Splashing of water
Water splashing against the enclosure from any direction shall have no harmful effect.
Test duration: 5 minutes Water volume: 10 litres per minute Pressure: 80–100 kPa
5
Water jets
Water projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects.
Test duration: at least 15 minutes Water volume: 12.5 litres per minute Pressure: 30 kPa at distance of 3 m
11
6
Powerful water jets
Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects.
Test duration: at least 3 minutes Water volume: 100 litres per minute Pressure: 100 kPa at distance of 3 m
7
Immersion up to 1 m
Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion).
Test duration: 30 minutes Immersion at depth of at least 1 m measured at bottom of device, and at least 15 cm measured at top of device
8
Immersion beyond 1 m
The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects.
Test duration: continuous immersion in water Depth specified by manufacturer
9
Powerful high temperature water jets
Protected against close­range high pressure, high temperature spray downs.
12
2.4 LED Indicators
The diagnostic LEDs that provide real-time information of system and optional status are located on the front panel of the industrial switch. The following table provides the description of the LED status and their meanings for the switch.
LED
Color
Status
Meaning
PWR1
Green On
Power 1 is active
Off
Power 1 is inactive
PWR2
Green On
Power 2 is active
Off
Power 2 is inactive
FAULT
Red On
Power or port failure
Off
No failure
P1 ~ P5/P8
Link/Ack
On
A network device is detected.
Blinking
The port is transmitting or receiving packets from the TX device.
Off
No device attached
PoE(1~5/8)( IPES)
On
The port is operating in PoE mode.(IPES)
Off
The port is not operating in PoE mode.(IPES)
13
Chapter 3 Hardware Installation
3.1Hardware installation
3.1.1Unpack switch and check the accessory with packing content list
3.1.2 Mount the switch on desired position. For the best ventilation, it is suggested to mount the switch on metallic surface.
3.1.3 Connect the M23/M12 connector of power input. The PoE power supply for IPES-0008B series is connected via a 5-pole M23 female connector while IES-0008B is with a 5-pole M12 female connector.
Voltage of Power Input
For IPES-0005B/0008B-12V series, the power input voltage can be from 9.5V to 57VDC to feed power on both the 802.3af and
802.3at standardized devices.
With IPES-0005B/0008B-72V series, the power input voltage can be from 72V to feed power on both 802.3af/at standardized devices. IES-0008B series can accept power input ranging from
50.4V~90V to be powered.
Please make sure that the external power supply unit you use to provide the PoE voltage meet the following criteria:
The output voltage of power supply must exceed 48VDC for 802.3af
and 53VDC for 802.3at operation(with IPES-0005B/0008B-72V, only 72VDC can power both the 802.3af and 802.3at PD.)
The power consumption can satisfy the total power request from all
PD devices required.
14
Pin assignment of Power input
Redundant Power Input
The power input can be supported redundantly. The supply voltage is
electrically isolated from the housing.
Note: With single power supply of the mains voltage, the device will
report a power failure. You can disable this power fail event via web browser.
3.1.4 Fitting the device, grounding
Install the system in a dry and clean area to protect the switch to get exposed with dirt.
Plug the connector to the power supply plug then turn on the power supply.
Ground
The chassis is grounded via a separate ground nut (M3). Use toothed locking washers for a good electrical connection.
15
Ground screw of IPES-0008B switch
3.1.5 Connect the M12 connector with RJ-45 data cable, ports are not used shall be caped that comes with the package to insulate the surrounding.
Pin assignment of M12 10/100Tx network connector
16
3.1.6 Check the status of LED, make sure the switch was in working status.
Note:
The protection class IP41 is only achieved when bolted together.
The other components attaching to the system have to meet with the
IP41 protection class in order to reach the whole system IP 41 protection.
Empty ports must be sealed with the protective caps supplied.
Loading...