IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment:
Model #: __________________________ Serial #: __________________________ Date Purchased: ___________________
Charbroiler Models Flush Open Burner Models Graduated Hot-Top Models
Uniform Hot-Top Models
Standard Griddle Models
Step-Up Open-Burner Models
Thermostatic Griddle Models
Combination Open-Burner Hot-Top Models
Combination Open-Burner Griddle Models
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.
10 Sunnen Drive, St. Louis, MO 63143 USA • www.langworld.com
M
ANUAL 1192040 REV 1 (01/10)
$30.00
CHEF SERIES SECTIONAL RANGE
MANUAL SECTION SR
SAFETY PRECAUTIONS CHEF SERIES SECTIONAL RANGE
SAFETY PRECAUTIONS
Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, service personnel, or to the equipment.
DANGER
WARNING
CAUTION
NOTICE
This symbol warns of immediate hazards that will result in severe injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury or
death.
This symbol refers to a potential hazard or unsafe practice that could result in injury,
product damage, or property damage.
This symbol refers to information that needs special attention or must be fully understood,
even though not dangerous.
WARNING
FIRE HAZARD
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of cookin g appliances. Keep area around cooking appliances free and clear of combustibles. Purchaser of equipment must post in a prominent location detailed instructions to be followed in the event the
operator smells gas. Obtain the instructions from the local gas supplier.
WARNING
BURN HAZARD
Contact with hot surfaces will cause severe burns. Always use caution when operating cooking appliances.
WARNING
EXPLOSION AND ASPHYXIATION HAZARD
In the event a gas odor is detected, shut down equipment at the main gas shut-off valve and immediately call the emergency phone number of your gas supplier.
Improper ventilation can result in headaches, drowsiness, nausea, and could result in death. Do not obstruct the flow of combustion and ventilation air to and from cooking appliances.
WARNING
ELECTRIC SHOCK HAZARD
For appliances that use electric power, disconnect the power to the appliance before cleaning. Do not remove panels that require tools to remove.
NOTICE
Lang appliances are intended for commercial use only. Not for household u se. Warranty will be void if service work is performed by other than a qualified technician, or if other than genuine
Lang replacement parts are installed. Give this Owner’s Manual and important papers to the proper authority to retain for future reference.
Published in the United States of America.
PAGE 2 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE INTRODUCTION

INTRODUCTION

Congratulations! You have purchased one of the finest pieces of heavy-duty commercial cooking equipment on the market.
You will find that your new equipment, like all Lang equipment, has been designed and manufactured to meet the toughest standards in the industry. Each piece of Lang equipment is carefully engineered and designs are verified through laboratory tests and field installations. With proper care and field maintenance, you will experien ce years of reliable, trouble-free operation. For best results, read this manual carefully.
RETAIN THIS MANUAL FOR FUTURE REFERENCE. This manual is for Lang Chef Series Sectional Ranges. This manual does NOT cover sectional fryers, fryer filter systems, salamander broilers, upright broilers, cheese
melters, or refrigerated bases. Those appliances have their own manuals. The location of the serial plate depends on the type of base (see
serial plate is located on the backside of the kick-plate below the oven door (lift the kick-plate straight up and tilt the top edge out and down.) On models with a cabinet base, the serial plate is located inside the left cabinet door. On modular (countertop) models, the serial plate is located inside the front valve panel.
Read these instructions carefully before attempting installation. Installation and initial startup should be performed by a qualified installer. Unless the installation instructions for this product are followed by a qualified service technician (a person experienced in and knowledgeable with the installation of commercial gas and/or electric cooking equipment) then the terms and conditions on the Manufacturer’s Limited Warranty will be rendered void and no warranty of any kind shall apply.
In the event you have questions concerning the installation, use, care, or service of the product, contact:
Lang Technical Service
10 Sunnen Drive
St. Louis, MO 63143 USA
Phone: (800) 807-9054 Fax: (314) 781-2714
www.langworld.com
Figure 1
Location of Serial Plate
Figure 1 below). On models with oven bases, the
Location of Serial Plate
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 3 OF 76
SPECIFICATIONS CHEF SERIES SECTIONAL RANGE

SPECIFICATIONS

NOTICE
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should comply with all local codes.
Lang reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
Lang appliances are intended for commercial use only, not for household use. The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA- B149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).

CLEARANCES

WARNING
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
There must be adequate clearance between the sectional range and combustible construction. Clearance must also be provided for servicing and for operation.
Open-Top
Standard-Burner
Models
Sides 10" 13" 10" 10" 6"
Back 6" 6" 12" 12" 6"
Floor* 0" 0" 0" 0" 0"
Do NOT install sectional charbroilers next to combustible materials.
* Models with 6" legs or casters are suitable for installation on combustible floors. Adequate clearance must be provided in the aisle in front of the unit to permit operation (including opening of
doors and/or removal of grease drawers, drippings trays, and/or oven racks), as well as for servicing. No ad ditional clearance is required for servicing as the sectional range is serviceable from the front.
Models with a convection-type oven require a minimum clearance of 2" between the motor on the back and non­combustible construction. Care must be taken to provide adequate air circulation to prevent the motor from overheating.
Open-Top
45K-Burner
Models
Griddle Models
Uniform Hot-Top
Models
Graduated
Hot-Top
Models
Minimum clearance from noncombustible construction is zero on the sides and back for all models (except for models with a convection-type oven).
The high-temperature flue products flow out through the top of the flue riser of all models, and from the top of open-top and charbroiler models. Installation under a vented hood is recommended.
Salamander broilers and cheese melters mounted on the flue riser of a sectional range may require additional minimum clearances (see the documentation for those appliances).
PAGE 4 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE SPECIFICATIONS

VENTILATION

WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products can cause headaches, drowsiness, nausea, or could result in death.
All gas appliances must be installed in such a manner that the flow of combustion and ventilation air is not obstructed. Provisions for adequate air supply must be provided. Do not obstruct the area under the control panel or below the oven door (on the front), or the area below the flue riser (on the back) as combustion air enters through these areas.
NOTICE
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the warranty.
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s instructions.
Air for combustion enters from the front below the valve panel, as well as from the rear into the burner box. Ranges with solid tops (griddles and hot-tops) vent their flue products up the flue riser. On units with a base oven, combustion air enters from the front below the oven door. Oven flue products are vented up the flue riser.
Lack of sufficient ventilation will cause poor burner and pilot operating characteristics, resulting in inefficient performance. Such conditions also cause high ambient temperatures at the manifold area and create valve and thermostat problems.
If a ventilation canopy is used, it is recommended that the canopy extend 6" past the sectional range and that the bottom edge be located 6'6" from the floor. Filters should be installed at an angle of 45° or more from the horizontal. This position prevents dripping grease, and facilitates collecting the run-off grease in a drip pan under the filter.
A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish pilot flames. Fresh air openings approximately equal to the fan area will relieve such a vacuum. The exhaust fan should be installed at least 2" above the top of the flue riser.
If the sectional range is connected directly to an outside flue, a CSA design certified down draft diverter must be installed.
In case of unsatisfactory performance by any gas appliance, check the appliance with the exhaust fan turned OFF. Do this only long enough to check whether doing so corrects any problems with equipment performance. Then turn the exhaust fan back on and let it run to remove any exhaust that may have accumulated during the test.

GAS SUPPLY

The sectional range is design-certified for operation on natural or propa ne gases. The sectional range is shipped configured and adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1 on page 3). Connect the sectional range ONLY to the type of gas for which it is configured and adjusted.
Each section has a 1-1/4" front gas manifold that can be coupled to adjacent section(s). Sections can be ordered with an optional 1" rear gas connection with a male NPT connector. Minimum supply pressure is 7" W.C. for natural gas, 11" W.C. for propane. An external pressure regulator and shut off valve must be provided. If using a flexible-hose gas connection, the I.D. of the hose must not be smaller than the connector on the unit and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent undue strain on the gas connection.
If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for satisfactory performance. A 1/8" pressure tap is located on the manifold to measure the manifold pressure. The supply line to the sectional range should be no smaller than the inside diameter of the pipe on the se ctional range to which it is connected.
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 5 OF 76
SPECIFICATIONS CHEF SERIES SECTIONAL RANGE
Figure 2
Dimensions
36" Flue Riser
12"
(305)
24"
(610)
9" (229)
33-3/4"
37-3/4"
(959)
(859)
Front Gas
Manifold
15-3/4"
(400)
37-3/4" (959)
34" (864)
4-1/2" (114)
SIDE VIEW
24" (610)
43-3/4" (1111)
40" (1016)
Motor for
Convection
Oven Model
Flue riser for “deep” depth-option extends rearward 6" (cooking suface area is same as for “standard” depth).
8-1/2" (216)
SIDE VIEW of Modular Model
39-3/4"
(1010)
36" (914)
48" (1219)
24" Flue Riser
5" Flue Riser
36"
(914)
Optional
Rear Gas
Connection
6" (152)
41"
(1041)
20"
(508)
60"
(1524)
72"
(1829)
7" (178)
7" (178)
2-1/2" (64)
Electrical
Connection
for Oven
Models
18"
(457)
7" (178)
2-1/2" (64)
PAGE 6 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE SPECIFICATIONS

UTILITY REQUIREMENTS AND CRATED WEIGHT

Model Width Base Type Top Type
LGR12C-B 12" cabinet flush 35K open-burner 70,000 60,000 - - 225 (102) LGR12C-G 12" cabinet standard griddle 32,000 28,000 - - 225 (102) LGR12C-H 12" cabinet uniform hot top 32,000 28,000 - - 180 (82) LGR12N-B 12" modular flush 35K open-burner 70,000 60,000 - - 175 (79) LGR12N-G 12" modular standard griddle 32,000 28,000 - - 175 (79) LGR12N-H 12" modular uniform hot top 32,000 28,000 - - 130 (59) LGR24C-BB 24" cabinet flush 35K open-burner 140,000 120,000 - - 480 (218) LGR24C-BB-SU 24" cabinet step-up 35K open-burner 140,000 120,000 - - 480 (218) LGR24C-CC 24" cabinet charbroiler 64,000 56,000 - - 360 (163) LGR24C-GG 24" cabinet standard griddle 64,000 56,000 - - 300 (136) LGR24C-HH 24" cabinet uniform hot top 64,000 56,000 - - 280 (127) LGR24C-TT 24" cabinet thermostatic griddle 64,000 56,000 - - 300 (136) LGR24N-BB 24" modular flush 35K open-burner 140,000 120,000 - - 395 (179) LGR24N-BB-SU 24" modular step-up 35K open-burner 140,000 120,000 - - 395 (179) LGR24N-CC 24" modular charbroiler 64,000 56,000 - - 360 (163) LGR24N-GG 24" modular standard griddle 64,000 56,000 - - 300 (136) LGR24N-HH 24" modular uniform hot top 64,000 56,000 - - 205 (93) LGR24N-TT 24" modular thermostatic griddle 64,000 56,000 - - 300 (136) LGR36A-BBB 36" convection oven flush 35K open-burner 255,000 222, 000 3.8 1.6 740 (336) LGR36A-BBB-SU 36" convection oven step-up 35K open-burner 255,000 222,000 3.8 1.6 740 (336) LGR36A-CCC 36" convection oven charbroiler 141,000 126,000 3.8 1.6 775 (352) LGR36A-GGG 36" convection oven standard griddle 141,000 126,000 3.8 1.6 840 (381) LGR36A-GRAD 36" convection oven graduated hot-top 107,000 87,000 3.8 1.6 760 (345) LGR36A-HHH 36" convection oven uniform hot top 141,000 126,000 3.8 1.6 720 (327) LGR36A-TTT 36" convection oven thermostatic griddle 141,000 126,000 3.8 1.6 840 (381) LGR36A-XX 36" convection oven flush 45K open-burner 225,000 222,000 3.8 1.6 740 (336) LGR36C-BBB 36" cabinet flush 35K open-burner 210,000 180,000 - - 490 (222) LGR36C-BBB-SU 36" cabinet step-up 35K open-burner 210,000 180,000 - - 490 (222) LGR36C-CCC 36" cabinet charbroiler 96,000 84,000 - - 620 (281) LGR36C-GGG 36" cabinet standard griddle 96,000 84,000 - - 590 (268) LGR36C-GRAD 36" cabinet graduated hot-top 62,000 45,000 - - 510 (231) LGR36C-HHH 36" cabinet uniform hot top 96,000 84,000 - - 470 (213) LGR36C-TTT 36" cabinet thermostatic griddle 96,000 84,000 - - 590 (268) LGR36C-XX 36" cabinet flush 45K open-burner 180,000 177,000 - - 490 (222) LGR36D-BBB 36" standard oven flush 35K open-burner 255,000 222,000 0* 0* 690 (313) LGR36D-BBB-SU 36" standard oven step-up 35K open-burner 255,000 222,000 0* 0* 690 (313) LGR36D-CCC 36" standard oven charbroiler 141,000 126,000 0* 0* 750 (340) LGR36D-GGG 36" standard oven standard griddle 141,000 126,000 0* 0* 790 (358) LGR36D-GRAD 36" standard oven graduated hot-top 107,000 87,000 0* 0* 710 (322) LGR36D-HHH 36" standard oven uniform hot top 141,000 126,000 0* 0* 670 (304) LGR36D-TTT 36" standard oven thermostatic griddle 141,000 126,000 0* 0* 790 (358) LGR36D-XX 36" standard oven flush 45K open-burner 225,000 222,000 0* 0* 690 (313) LGR36N-BBB 36" modular flush 35K open-burner 210,000 180,000 - - 450 (204) LGR36N-BBB-SU 36" modular step-up 35K open-burner 210,000 180,000 - - 450 (204) LGR36N-CCC 36" modular charbroiler 96,000 84,000 - - 350 (159) LGR36N-GGG 36" modular standard griddle 96,000 84,000 - - 530 (240) LGR36N-GRAD 36" modular graduated hot-top 62,000 45,000 - - 450 (204) LGR36N-HHH 36" modular uniform hot top 96,000 84,000 - - 410 186) LGR36N-TTT 36" modular thermostatic griddle 96,000 84,000 - - 530 (240) LGR36N-XX 36" modular flush 45K open-burner 180,000 177,000 - - 450 (204) LGR48A-CCCC 48" convection oven charbroiler 173,000 154,000 3.8 1.6 621(281) LGR48A-GGGG 48" convection oven standard griddle 173,000 154,000 3.8 1.6 729 (330) LGR48A-TTTT 48" convection oven thermostatic griddle 173,000 154,000 3.8 1.6 729 (330) LGR48C-CCCC 48" cabinet charbroiler 128,000 112,000 - - 462 (209) LGR48C-GGGG 48" cabinet standard griddle 128,000 112,000 - - 480 (217) LGR48C-TTTT 48" cabinet thermostatic griddle 128,000 112,000 - - 480 (217) LGR48D-CCCC 48" standard oven charbroiler 173,000 154,000 0* 0* 568 (257) LGR48D-GGGG 48" standard oven standard griddle 173,000 154,000 0* 0* 676 (306) LGR48D-TTTT 48" standard oven thermostatic griddle 173,000 154,000 0* 0* 676 (306) LGR48N-CCCC 48" modular charbroiler 128,000 112,000 - - 276 (125) LGR48N-GGGG 48" modular standard griddle 128,000 112,000 - - 395 (179) LGR48N-TTTT 48" modular thermostatic griddle 128,000 112,000 - - 395 (179)
Natural Gas
(BTU/hour)
GAS ELECTRICITY
Propane
(BTU/hour)
120V
(amps)
208/240V
(amps)
* Standing Oven Pilot Models
Crated Weight
pounds (kg)
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 7 OF 76
SPECIFICATIONS CHEF SERIES SECTIONAL RANGE

ELECTRICITY SUPPLY

Units with convection-oven bases with optional electronic ignition require electric po wer (50Hz or 60Hz single-phase AC). 120V models have a 7-foot (2134 mm) power cord with a grounded plug (1.0 amps for “D” Models and 4.8 amps for “A” Models). The 208/240V models have a terminal block for connection to a single-phase 208/24 0V source (1.0 amps for “D” Models and 2.6 amps for the “A” Models).
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. An electrical diagram is located on the rear of the range, near the motor.
PAGE 8 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE OPERATION

OPERATION

DANGER
EXPLOSION HAZARD
In the event a gas odor is detected, shut down equipment at the main shut off valve. Immediately call the emergency phone number of your gas supplier.
CAUTION
If a pilot flame pilot should go out, the flow of gas to the corresponding burner is NOT interrupted. Consequently, it is the responsibility of the operator to check the ignition of each burner immediately EVERY TIME a burner is turned on. Should ignition fail after 10 seconds, turn off the burner, wait 5 minutes, and then try again.

LIGHTING AFTER GAS HAS BEEN SHUT OFF

When turning on the main gas supply to a sectional range, do the following:
1. Make sure that all the control knobs and power switches of all the connected appliances are in the OFF position.
2. Turn on the gas-supply shut-off valve(s).
3. Light the standing pilots of each connected appliance.
4. Light the ovens of the sectional range first, then wait six minutes before turning on the top sections. This enables all air to be purged from the sectional-range gas piping.

SHUTDOWN OF ENTIRE RANGE

To place the range in a standby state (ready for use), Oven bases with the electronic ignition option, turn all burner control knobs to OFF, set all thermostats to their lowest position, and switch all ovens OFF. The pilots will remain lit. On the standing pilot units, same as above except turn thermostat knob to the “OFF” position. The pilots will remain lit.
To completely shut down the range for an extended period (or prior to disconnecting the gas supply), place the range in a standby state (as described in the previous paragraph), then turn OFF the manual shut -off valves of all gas supply connections. This will extinguish the pilots.
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 9 OF 76
OPERATION CHEF SERIES SECTIONAL RANGE
Figure 3
Operation of Open-Burner Sections
Each 12"-wide section has two control knobs. The left knob controls the rear burner, while the right knob controls the front burner. Each knob can be turned to OFF or to any position in the range from LOW to HIGH.
To start cooking, turn the appropriate control knob to HIGH. Visually check that the burner ignites. The gas does NOT automatically shut off if the burner does not ignite! If the burner does not ignite, check and/or light the pilots (see procedure at right). When the burner is hot, the burner flame should appear blue and steady (some slight yellowing of the flame tips may occur when using propane gas).
While cooking, do not allow excessive drippings and/or debris to accumulate on or below the burners. When necessary, pull out and clean the drippings tray.
Burner Grate
(lifts out for cleaning)
When done cooking, turn the appropriate control knob to OFF. (The pilot should remain lit).
Each burner has a pilot located beside the burner. To light a pilot, do the following:
1. Check that the burner control knob is in the OFF position.
2. Check that the pilot is in the correct position beside the burner.
3. Turn on the gas supply to the sectional range (if not already on).
4. Light the pilot with a match or a pilot-lighting device. The pilot flame should be blue and steady.
Rear-Burner
Control Knob
(OFF, HIGH-to-LOW)
Front-Burner
Control Knob
(OFF, HIGH-to-LOW)
Drippings Tray
(slides out for cleaning)
PAGE 10 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE OPERATION
Figure 4
Operation of Uniform Hot-Top Section
Each 12”-wide section has one control knob, which can be turned to OFF or to any position in the range from LOW to HIGH. When the control is set to HIGH, the hot top surface will heat to about 700°F (370°C).
To start cooking, turn the appropriate control knob to HIGH. Visually check that the burner ignites.
automatically shut off if the burner does not ignite!
The gas does NOT
If the burner does not ignite, check and/or light the pilots (see procedure at right). When the burner is hot, the burner flame should appear blue and steady (some slight yellowing of the flame tips may occur when using propane gas).
Do not waste gas and abuse equipment by leaving the burner on HIGH all the time.
certain electronic components may occur, and
YOUR WARRANTY
. During idle periods, turn the control to
Damage to the plates and
MAY VOID
LOW to keep the top warm.
Uniform HotTop Plate
(lifts out for cleaning
and lighting pilot)
When done cooking, turn the appropriate control knob to OFF. (The pilot should remain lit).
Each 12”-wide section has two burners, each of which has a pilot located near the front of the burner. To light the pilots, do the following:
1. Check that the control knob is in the OFF position.
2. Lift up a hot-top section plate in order to expose the two pilots.
3. Check that each pilot is in the correct position.
4. Turn on the gas supply to the sectional range (if not already on).
5. Light the pilots with a match or a pilot-lighting device. The pilot flames should be blue and steady.
Burner Control Knob
(OFF, HIGH-to-LOW)
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 11 OF 76
OPERATION CHEF SERIES SECTIONAL RANGE
Figure 5
Operation of Graduated Hot-Top Section
Each section has one control knob, which can be turned to OFF or to any position in the range from LOW to HIGH. When the control is set to HIGH, the round center section will heat to about 725°F (385°C), the ring-shaped section will heat to about 625°F (330°C), and the outer areas will heat to about 500°F (260°C).
To start cooking, turn the control knob to HIGH. Visually check that the burner ignites.
automatically shut off if the burner does not ignite!
The gas does NOT
If the burner does not ignite, check and/or light the pilots (see procedure at right). When the burner is hot, the burner flame should appear blue and steady (some slight yellowing of the flame tips may occur when using propane gas).
Do not waste gas and abuse equipment by leaving the burner on HIGH all the time.
certain electronic components may occur, and
YOUR WARRANTY
. During idle periods, turn the control to
Damage to the plates and
MAY VOID
LOW to keep the top warm.
When done cooking, turn the control knob to OFF. (The pilot should remain lit).
Each section has one burner. The pilot is located adjacent to the burner. To light the pilot, do the following:
1. Check that the control knob is in the OFF position.
2. Lift out the round center plate in order to expose the pilot.
3. Check that the pilot is in the correct position.
4. Turn on the gas supply to the sectional range (if not already on).
5. Light the pilot with a match or a pilot-lighting device. The pilot flame should be blue and steady.
Medium TemperatureArea (plate lifts out for cleaning)
Lower Temperature Area
(plate lifts out for cleaning)
HighTemperature Area
(plate lifts out for cleaning
and lighting pilot)
Lower TemperatureArea
(plate lifts out for cleaning)
Burner Control Knob
(OFF, HIGH-to-LOW)
PAGE 12 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE OPERATION
Figure 6
Operation of Charbroiler Section
Each 12”-wide section has one control knob, which can be turned to OFF, HIGH, or LOW. Each burner top-grate can be turned over to provide either wide branding marks or narrower branding marks with channels to carry away drippings (and so reduce flare up). The back-to-front slope of each top-grate is adjusted by positioning the back end of the top-grate on either the lower or the higher grate-support rail. The radiants (just above the burners) can be reversed front­and-back to provide higher heat toward the back than the front, or vice versa. “Lava rock” briquettes can be placed on grates located above the radiants.
To start cooking, turn the appropriate control knob to HIGH. Visually check that the burner ignites.
automatically shut off if the burner does not ignite!
The gas does NOT
If the burner does not ignite, check and/or light the pilots (see procedure at right). When the burner is hot, the burner flame should appear blue and steady (some slight yellowing of the flame tips may occur when using propane gas).
Grates
(lift out for cleaning)
When done cooking, turn the appropriate control knob to OFF. (The pilot should remain lit).
Each 12”-wide section has two burners, each of which has a pilot located near the front of the burner. To light the pilots, do the following:
1. Check that the burner control knob is in the OFF position.
2. Lift up a grate in order to expose the two pilots. They are accessible through a slot near the front end of the radiant plate.
3. Check that each pilot is in the correct position.
4. Turn on the gas supply to the sectional range (if not already on).
5. Light the pilots with a match or a pilot-lighting device. The pilot flames should be blue and steady.
Burner Control Knob
(OFF, HIGH, or LOW)
Drippings Tray
(slides out for cleaning)
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 13 OF 76
OPERATION CHEF SERIES SECTIONAL RANGE
Figure 7
Operation of Standard (Non-Thermostatic) Griddle Sections
Each 12”-wide section has one control knob, which can be turned to OFF, HIGH, or LOW.
To start cooking, turn the appropriate control knob to HIGH. Check that the burner ignites.
automatically shut off if the burner does not ignite!
The gas does NOT
If the burner does not ignite, check and/or light the pilots (see procedure at right). When the burner is hot, the burner flame should appear blue and steady (some slight yellowing of the flame tips may occur when using propane gas).
Always remember to heat the griddle slowly because quick heating may cause costly damage. Never place utensils on the griddle.
Do not waste gas and abuse equipment by leaving the griddle on HIGH all the time.
certain electronic components may occur, and
YOUR WARRANTY
. During idle periods, turn the control to
Damage to the griddle and
MAY VOID
LOW to keep the griddle warm. (Do not allow the griddle to
overheat above 550°F (288°C), as this will cause warping or breakage.)
When necessary while cooking, pull out and empty the grease drawer.
When done cooking, turn the appropriate control knob to OFF. (The pilot should remain lit).
Each griddle section has a single pilot that is lit using a long match inserted thorough a hole in the front valve panel. (A 48"-wide griddle has two pilots.) To light the pilot, do the following:
1. Check that all the control knobs are in the OFF position.
2. Turn on the gas supply to the sectional range (if not already on).
3. Light the pilot by inserting a long match (at least 11" long) or pilot-lighting device straight into the hole on the front valve panel of the griddle.
Burner Control Knob
(OFF, HIGH, or LOW)
Grease Drawer
(slides out for cleaning)
Pilot-Lighting
Opening
PAGE 14 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE OPERATION
Figure 8
Operation of Thermostatic Griddle Sections
Each 12”-wide section has one control knob that can be turned to OFF, or to any temperature in the range 150°F to 400°F (66°C to 204°C).
To start cooking, turn on the appropriate control knob. Check that the burner ignites. If the burner does not ignite, check and/or light the pilots (see procedure at right).
Never place utensils on the griddle.
Do not waste gas and abuse equipment by leaving the griddle set at a high temperature all the time.
Damage to the griddle and certain electronic components may occur, and
MAY VOID YOUR WARRANTY. During idle periods,
turn the control to a low temperature to keep the griddle warm. (Do not allow the griddle to overheat above 550°F (288°C), as this will cause warping or breakage.)
When necessary while cooking, pull out and empty the grease drawer.
When done cooking, turn the appropriate control knob to OFF. (The pilot should remain lit).
Each griddle section has a single pilot that is lit using a long match inserted thorough a hole in the front valve panel. (A 48"-wide griddle has two pilots.) To light the pilot, do the following:
1. Check that all control knobs are in the OFF position.
2. Turn on the gas supply to the sectional range (if not already on).
3. Turn on the Griddle Gas Shut-Off Valve (if not already on).
4. Press and hold in the Safety Switch Button.
5. Light the pilot by inserting a long match (at least 11" long) or pilot-lighting device straight into the hole on the front valve panel of the griddle.
6. After about a minute, release the Safety Switch Button. The pilot should remain lit.
Safety Switch Button
Burner Control Knob
(OFF, temperature)
Griddle Gas
Shut-Off Valve
Grease Drawer
(slides out for cleaning)
Pilot-Lighting
Opening
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 15 OF 76
OPERATION CHEF SERIES SECTIONAL RANGE
Figure 9
Operation of Oven
Each oven has a thermostatic control that can be set in the range 175°F to 550°F (66°C to 260°C). Convection ovens have a fan that can be set to HI speed or LO speed.
While cooking, if the door is opened on a convection oven, the fan and heat will temporarily stop until the door is closed.
Do not allow excessive drippings and/or debris to accumulate on the interior of the oven. When necessary, pull out and clean the oven-bottom tray.
To light and start cooking, do the following: FOR UNITS WITH A STANDING PILOT
1. Open kick panel and locate knob on valve assembly.
2. Turn the knob to PILOT and press inward. While holding the knob inward, light the pilot with an appropriate lighter.
3. Hold knob in the inward position for 30 seconds and release. The pilot should remain lit.
4. Turn the knob to ON and close kick panel.
5. Select on the thermostat the cooking temperature appropriate for the food to be cooked.
6. For convection ovens, select the fan speed appropriate for the food to be cooked.
FOR UNITS WITH ELECTRONIC IGNITION
1. Set the Oven Power Switch to ON. The pilot will light automatically. (You will hear a “snapping” sound until the pilot ignites.)
2. Select on the thermostat the cooking temperature appropriate for the food to be cooked.
3. For convection ovens, select the fan speed appropriate for the food to be cooked.
When done cooking, turn the Oven Power Switch to OFF.
Controls for Ovens with Standing Pilot
Oven Power Switch
Fan-Speed Switch
(for Convection Ovens)
Oven Thermostat
Controls for Ovens
with Electronic Ignition
WARNING
PILOT-ON Knob
THE USE OF ALUMINUM FOIL CAN CAUSE HEAT DISTRIBUTION PROBLEMS IN OVENS. EXTREME CARE MUST BE USED WHEN PLACING ALUMINUM FOIL IN THE OVEN TO ENSURE THAT IT DOES NOT BLOCK OR CHANGE THE AIR FLOW. THE USE OF ALUMINUM FOIL MAY VOID THE PRODUCT WARRANTY IF ITS USE IS ASCERTAINED TO BE A PROBLEM.
PAGE 16 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE CLEANING & MAINTENANCE

CLEANING & MAINTENANCE

WARNING
Shut off the gas supply to the appliance before cleaning or performing maintenance on any gas appliance. The appliance may be equipped with a restraint device to limit its movement in order to prevent damage to the
gas connection. If disconnection of this restraint is necessary to move the appliance for cleaning or maintenance, reconnect the restraint when the appliance is moved back to its original installed position.
Lang appliances are sturdily constructed of the best materials and are designed to provide du rable service when treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and cleaned daily. Naturally, the periods for this care and cleaning depend on the amount and degree of usag e.
Following daily and periodic maintenance procedures will enhance long life for your equipm ent. Climatic conditions (such as salt air) may require more thorough and frequent cleaning or the life of the equi pment could be adversely affected.
Keep exposed, cleanable areas clean at all times.

DAILY CLEANING AND MAINTENANCE

The daily cleaning procedure is as follows:
1. Shut off the main gas supply and allow the sectional range to cool.
2. Pull out, empty, and clean all drippings trays and grease drawers.
3. Remove and clean all oven racks and oven-bottom trays. Wipe clean the interior of the oven.
4. Visually check for any food and/or debris that may have fallen down into the burner areas.
5. Wipe clean all exterior surfaces.
6. Replace the cleaned and dried drippings trays, grease drawers, and oven components.
7. Check that nothing has been left on or near the sectional range that might block the entry of combustion air or the escape of combustion exhaust.

MONTHLY CLEANING AND MAINTENANCE

The following tasks should be performed monthly:
1. Clean around burner air mixers and orifices if lint has accumulated in these areas.
2. Check for proper pilot operation. Check that the pilot flames are blue (with little or no yellow in the flame tips), stable (not lifting off the pilots), and not producing carbon. If adjustment is necessary, call for service.
3. Check for proper burner operation. The burner flames should be blue and stable. If adjustment is necessary, call for service.

SEMIANNUAL CLEANING AND MAINTENANCE

At least twice a year the venting system should be examined and cleaned.

STAINLESS-STEEL SURFACES

To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature, use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean cloth.
To remove BAKED-ON grease and food splatter, or condensed vapors; apply cleanser to a damp cloth or sponge and rub cleanser on the metal in the direction of the polishing lines on the metal. Rubbing cleanser, as gently as possible, in the direction of the polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR MOTION. Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 17 OF 76
CLEANING & MAINTENANCE CHEF SERIES SECTIONAL RANGE
WOOL as any particles left on the surface will rust and further spoil the appearance of the finish. NEVER USE A WIRE BRUSH, STEEL SCOURING PADS (EXCEPT STAINLESS), SCRAPER, FILE OR OTHER STEEL TOOLS. Surfaces which are marred collect dirt more rapidly and become more difficult to clean. Marring also increases the possibility of corrosive attack. Refinishing may then be required.
“Heat tint” is darkened areas that sometimes appear on stainless steel surfaces where the area has been subjected to excessive heat. These darkened areas are caused by thickening of the protectiv e surfa ce of t he stainless steel and are not harmful. Heat tint can normally be removed by the foregoing, but tint which does not respond to this procedure calls for a vigorous scouring in the direction of the polish lines using SCOTCH-BRITE scouring pads or a STAINLESS scouring pad in combination with a powered cleanser. Heat tint may be lessened by reducing heat to equipment during slack periods.

BAKED-ENAMEL SURFACES

Allow appliance to cool somewhat after use and wash baked-enamel surfaces with a hot, mild detergent or soap solution. In particular, clean off all grease deposits. Dry thoroughly with a dry cloth.

OPEN-BURNERS AND GRATES

The grates can be removed and cleaned with a solution of hot water and strong soap or detergent. The burners themselves require little attention, but if spillage should occur, it may be necessary to clean around pilot areas, air mixer and under burners. Use a wire brush if necessary. Periodically, open-burners sho uld be removed and cleaned. Allow the interior of the burner to drain, and dry thoroughly before replacing.

HOT-TOP SURFACES

Before cleaning hot-top surfaces, allow them to cool. If water is used on hot-tops while they are still hot, they may crack, so avoid this practice. The hot-top plates can be removed and cleaned with hot water and detergent. A wire brush may be used on the underside of the hot top plate. It is recommended not to clean tops while still on the range, even if cooled, as excess water will drip into the burner box and deteriorate the metal.

CARE OF GRIDDLES

A griddle should be carefully cared for in order to avoid possible damage. (The griddle should have been tempered as part of the installation procedure, see page any type of steel wool. Small particles may be left on the surface and get into food products. Do not clean spatula by hitting the edge on the griddle plate. Such action will only cut and pit the griddle plate, leaving it rough and hard to clean.
27). Use a Norton Alundum Griddle Brick to clean the griddle. Do not use

OVEN INTERIOR

WARNING
FOR YOUR SAFETY, DISCONNECT THE POWER SUPPLY TO THE SECTIONAL RANGE BEFORE CLEANING THE OVEN. WHEN CLEANING THE BLOWER WHEEL OF A CONVECTION OVEN, BE SURE TO HAVE THE POWER SWITCH IN THE “OFF” POSITION.
To clean the oven interior, first allow the oven to cool. Remove oven bottom and clean it by rubbing with strong detergent and a Brillo pad or similar scrubber. “Spillovers” should be cleaned from the bottom as soon as possible to prevent carbonizing and a “burnt-on” condition. For stubborn accumulations, commercial oven clea ners are recommended.
The porcelain oven door lining can be cleaned in a similar manner. The side, rear and top lining should be wiped only with a cloth dampened with a mild detergent and water. Avoid using excessive amounts of water, as this may drip into burner compartment and deteriorate the metal in that area. Do not use strong commercial cleaners or abrasive pads on the side, rear or top linings, as they may damage the finish or leave gray residue.
PAGE 18 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE INSTALLATION

INSTALLATION

NOTICE
These installation procedures must be followed by qualified personnel or warranty will be void. Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,
Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should comply with all local codes.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA- B149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).
NOTICE
EXHAUST FANS AND CANOPIES: It is recommended that the range be installed under a ventilation hood.
Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by warranty.
NOTICE
In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation hoods shall comply with 248 CMR interlocking requirements.
This installation procedure does NOT cover sectional fryers, fryer filter systems, salamander b roile rs, upright broilers, cheese melters, or refrigerated bases. Consult the manuals of those appliances when they are being installed as part of a sectional range battery.

STEP 1: UNPACKING

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a claim must be made with the delivering carrier.
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier can supply the necessary forms.
A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all contents plus all packing material.
For each section, do the following:
1. Cut the banding straps and remove the corrugated cardboard surrounding the section. (If legs, casters, a flue riser, and/or shelf components were shipped in the same container, set them aside for installation in later steps of this procedure. Do not remove any tags or labels attached to the range until the range is installed and working properly.
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 19 OF 76
INSTALLATION CHEF SERIES SECTIONAL RANGE
2. Cut the banding strap holding the range to the wooden skid.
3. Unbolt the shipping hold-down brackets from the skid, then remove the brackets from the appliance (see
Figure
10).
4. If the range is to be installed on 6" legs, go to Step 2a. If the range is to be installed on 6" casters, go to Step 2b. If the range is to be installed on a caster-frame, go to Step 2c.
Figure 10
Removal of Shipping Hold-Down Brackets
Shipping Hold-Down Brackets

STEP 2A: ATTACH LEGS TO THE RANGE

A set of four legs is packed with units ordered with legs. (For units ordered with casters, go to Step 2b.) A threaded leg pad is fastened to the base frame at each corner. Each leg has a correspondin g mating thread. The
legs can be adjusted to overcome a slightly uneven floor.
1. Raise the range sufficiently to allow the legs to be attached. For safety, “shore up” and support the range with an adequate blocking arrangement strong enough to support the load.
2. Screw the legs into the holes in the centers of the leg pads (see
3. Lower the range gently onto a level surface. Never drop or allow the range to fall.
4. Go on to Installation Step 4.
Figure 11).
PAGE 20 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE INSTALLATION
Figure 11
Installation of Legs

STEP 2B: ATTACH CASTERS TO THE RANGE

NOTICE
For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate
means must be provided to limit the movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit the appliance movement and (3) the restraining means should be attached to a frame member on the back of the unit.
A set of four casters is packed with units ordered with casters (instead of legs). A threaded leg pad is fastened to the base frame at each corner. Each caster has a corresponding mating thread. The
casters can be adjusted to overcome a slightly uneven floor. Casters are provided with a fitting for proper lubrication when required.
1. Raise unit sufficiently to allow the casters to be attached. For safety, “shore up” and support the range with an adequate blocking arrangement strong enough to support the load.
2. Screw the casters into the holes in the centers of the leg pads (see locking brake under the front of the range.
3. Lower the range gently onto a level surface. Never drop or allow the range to fall.
4. Go to Installation Step 3.
Figure 12). Install the casters that have a
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 21 OF 76
INSTALLATION CHEF SERIES SECTIONAL RANGE
Figure 12
Installation of Casters
1

STEP 2C: MOUNT RANGE ON CASTER FRAME

NOTICE
For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate
means must be provided to limit the movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit the appliance movement and (3) the restraining means should be attached to a frame member on the back of the unit.
The range can be mounted on an optional caster frame. The frame will have a threaded leg pad at each corner. Each caster has a corresponding mating thread. The casters can be adjusted to overcome a slightly uneven floor. Casters are provided with a fitting for proper lubrication when required.
1. Assemble the caster frame components.
2. Screw the casters into the holes in the centers of the leg pads of the caster frame. Install the casters that have a locking brake under the front of the battery.
3. Lower the caster frame gently onto a level surface. Never drop or allow the frame to fall.
4. Block and brace the frame so that it will not move while the battery sections are installed on it.
5. Lift and gently place the range in position on the caster frame. Never drop or allow the range to fall.
6. Bolt the range to the caster frame.
7. Go to Installation Step 3.
PAGE 22 OF 76 OWNERS MANUAL 1192040 REV 1 (01/10)
CHEF SERIES SECTIONAL RANGE INSTALLATION

STEP 3: ATTACH RESTRAINT TO RANGE (OR BATTERY) MOUNTED ON CASTERS

NOTICE
For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate
means must be provided to limit the movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit the appliance movement and (3) the restraining means should be attached to a frame member on the back of the unit.
Install the restraint cable to a range (or battery) mounted on casters using the following procedure:
1. Secure the restraining-device bracket (item “B” in appliance connector inlet and outlet connections. Use four #12 screws (items “C”) and plastic anchors (items “A”) if necessary.
2. Install eye-bolt (item “F”) to a frame member on the rear of the equipment. After checking carefully behind the frame member for adequate clearance, drill a 1/4" hole through the frame member.
3. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through the 1/4" drilled hole and secure with a washer (item “H”) and nylon lock nut (item “I”).
4. Using the spring-loaded snap hooks, attach the restraining device to the bracket and the eye-bolt.
5. Using the cable clamp (item “D”), adjust the restraining device extended length to prevent over-bending or kinking of the appliance connector.
For units not equipped with flame safety devices, be sure all valves are turned off prior to disconnecting. After reconnecting, be sure all control knobs are turned off and all pilots are lit.
Figure 13) to a wall stud located as close as possible to the
NOTICE
Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit the appliance movement.
The restraining means should be attached to a frame member on the back of the unit.
OWNERS MANUAL 1192040 REV 1 (01/10) PAGE 23 OF 76