Lang Manufacturing 136SB Service Manual

Installation
Operation
136SB, 136SMB, 160SB, 160SMB Salamander
Star Manufacturing International 10 Sunnen Drive St. Louis, MO 63143 Part Number 2M-60807-01 Phone: 314-781-2777 Fax: 314-781-2714 Rev D www.star-mfg.com
May 31, 2007
TABLE OF CONTENTS
INSTALLATION ..........................................................................................................................................1
RECEIVING ELECTRICAL VENTILATION PLACEMENT
THE APPLIANCE ....................................................................................................................1
CONNECTION......................................................................................................................1
AND CLEARANCES..........................................................................................................1
ON RANGE............................................................................................................................2
NON - PREDRILLED RANGES..................................................................................................................2
PREDRILLED RANGES .............................................................................................................................2
OPERATION.................................................................................................................................................3
INITIAL
PREHEAT .......................................................................................................................................3
PARTS LIST..................................................................................................................................................3
WIRING DIAGRAMS..................................................................................................................................4
208/240 440/480
VOLT ................................................................................................................................................4
VOLT ................................................................................................................................................5
INSTALLATION
RECEIVING THE APPLIANCE
Upon receipt of the appliance, check for freight damage both visible and concealed. Visible damage should be noted on the freight bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means loss or damage which does not become apparent until the merchandise has been unpacked. If concealed loss or damage is discovered, make a written request for inspection by the carrier's agent within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged merchandise to Star Manufacturing International. File your claim with the carrier.
Uncrate the appliance as near its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
ELECTRICAL CONNECTION
The electrical connection must be made in accordance with local codes or in the absence of local codes with NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1).
Supply wire size must be large enough to carry the amperage load for the number of appliances being installed. Wire size information can be found on the data plate and on the chart below.
MODEL
NUMBER
36S-SH 6.0 6.0 0.0 6.0 28.8 28.8 0.0 25.0 25.0 0.0 12.5 12.5 0.0 28.8 25.0
TH REE PH A SE LO ADI NG NONINAL AM PS PER LINE
K. W. PER PHA SE
L1 - L2 L2 -L3 L3 - L1 208 VOLT 240 VOLT 480 VOLT 208 V. 240 V.
TOTAL
K.W.
L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2
ELECT RI CA L D A TA
TH REE PHA SE SIN GLE PHA SE
VENTILATION AND CLEARANCES
Standard minimum clearance from combustible construction is as follows:
3 inches from sides 3 inches from back
Keep the appliance area free and clear of combustible material and do not obstruct the flow of combustion or ventilation air.
The installation of any components such as a vent hood, grease extractors, and/or fire extinguisher systems, must conform to the their applicable nationally recognized installation standards.
1