These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION,
OPERATION & MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR
WARNING, TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
CONTROL PANEL. NO USER-SERVICABLE PARTS INSIDE.
REPAIRS SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY.
FOR YOUR SAFTEY
THE VICINTIY OF THIS OR ANY OTHER APPLIANCE.
POST IN PROMINENT LOCATION
WARNING
SERVICING THIS EQUIPMENT.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
NOTICE
Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all
liability.
Lang reserves the right to change specications and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations,
the specications contained in this sheet are subject to change without notice. While
Lang exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions reached as a
result of using the specications. By using the information provided, the user assumes all risks
in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local dealer for service or required maintenance. Please record the model number, serial
number, voltage and purchase & Installation Information in the area below and have it ready when you
call to ensure a faster service.
Model No.:
Serial No.:
Voltage:
Purchased From:
Location:
Purchase
Date:
2M-W1823, Envirozone T-Stat Electric Griddle
1-Phase
or 3 Phase:
Installed Date:
2
PROBLEMS, QUESTIONS or CONCERNS
Before you proceed consult you authorized Lang service agent directory
or
Call the Lang Technical Service & Parts Department at 314-678-6315
NOTICE Service on this or any other Lang appliance must be performed by
qualied personnel only. Consult your Lang Authorized Service Agent
Directory. You can call our service number 314-678-6315 or visit our
website www.langworld.com for the service agent nearest you.
3
Width
Depth
Height
EQUIPMENT SPECIFICATIONS
Model
124ZT
124ZTD36.5” (92.7 cm)
136ZT
136ZTD36.5” (92.7 cm)
148ZT
148ZTD36.5” (92.7 cm)
160ZT
160ZTD36.5” (92.7 cm)
172ZT
172ZTD36.5” (92.7 cm)
(91.4 cm)
(121.9 cm)
(152.4 cm)
Dimensions (Not including Legs)
WidthDepthHeightActualShipping
24”
(61 cm)
36”
48”
60”
72”
(183 cm)
30.4” (77.2 cm)
30.4” (77.2 cm)
30.4” (77.2 cm)
30.4” (77.2 cm)
30.4” (77.2 cm)
16.4” (41.6 cm)
Clearance from
combustible surface
Sides: 2”,
Back: 2”
Weight
243 lbs.280 lbs.
110 kg127 kg
368 lbs.410 lbs.
167 kg186 kg
483 lbs.515 lbs.
220 kg234 kg
621 lbs.665 lbs.
282 kg302 kg
724 lbs.800 lbs.
329 kg364 kg
Freight
Class
85
ELECTRICAL SPECIFICATIONS
Kw
ModelVoltsHz. Ph
124ZT208/24060 1/31258450 29 296
136ZT208/24060 1/31887250 50 506
148ZT208/24060 1/324116175 75 503
160ZT208/24060 1/31258450 29 2961887250 50 506
172ZT208/24060 1/31887250 50 5061887250 50 506
TotalA 1PH.Supply L1 L2 L3 Supply
4
Kw
TotalA 1PH.Supply L1 L2 L3 Supply
2M-W1823, Envirozone T-Stat Electric Griddle
EQUIPMENT DESCRIPTION
Griddle Surface
Gutter
Grease Pan
Section
Pilot Light
Section
Temp Dial
Feet
IL2479
Exterior Construction
The griddle dimensions are 17” (43.18cm) High, 30” (76.20cm) Deep, and width is dependent on the
actual model number.
The Sides, Bottom, and Rear wall are constructed of double wall stainless steel, which allows closer
installation to combustible surfaces.
The griddle surface is made of 1” thick, highly polished steel to reduce hot and cold spots, recovery
problems, warping, and ensure even heat to the edges of the griddle.
Controls
Each twelve-inch section has its own temperature dial that snaps into place to lock in any temperature
from 200°F to 550°F (93°C to 287°C) in 25° increments.
Each twelve-inch section of the griddle is controlled by an area sensitive RTD probe, which can sense
and react to a temperature change of +/- 4°F.
Each twelve-inch section has a set of 6 K.W. elements for high efciency, quick recovery and outstanding
performance
Technical
These Enviro-Zone Electric series thermostat griddle operates on either 208, 240V and are shipped three
phase, (unless in specic specications). 208, 240V can be eld converted to single phase.
Minimum clearances: 2” from side and back
NOTICE The data plate is on the right side of the griddle. The griddle voltage,
2M-W1823, Envirozone T-Stat Electric Griddle
wattage, serial number, wire size, and clearance specications are on
the data plate. This information should be carefully read and understood
before proceeding with the installation.
5
CAUTION
UNPACKING
Receiving the Griddle
Upon receipt, check for freight damage, both visible and concealed.
Visible damage should be noted on the freight bill at the time of delivery
and signed by the carrier’s agent. Concealed loss or damage means it
does not become apparent until the merchandise has been unpacked. If
concealed loss or damage is discovered upon unpacking, make a written
request for inspection by the carrier’s agent within 15 days of delivery. All
packing
material should be kept for inspection. Do not return damaged
merchandise to Star Manufacturing Company. File your claim with
the carrier.
Location
Prior to un-crating, move the griddle as near to its intended location as practical. The crating will help
protect the unit from the physical damage normally associated with moving it through hallways and
doorways.
Un-crating
The griddle will arrive completely assembled inside a wood frame and strapped to a skid. Cut the
straps and remove the wood frame.
The griddle can now be removed from the skid.
THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN
HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT
(SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE
SKID AND MOVE IT TO THE PLACE OF
INSTALLATION.
CAUTION
WARNING
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH GRIDDLE WILL BE
LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE GRIDDLE.
SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
2M-W1823, Envirozone T-Stat Electric Griddle
6
Loading...